Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_lst.aspx E(`.;':, 'k Yt`' .�-,�i b?9 p', .1 P'.��:� �.r+.°��1-134'6 PS�LS��A ti,°.t G� <{ �_.__Y_; , X �..:-s. .--••`"'�'' j•,(.c: (ci BCIS Home t Log In K User Registration { Hot Topics I Submit Surcharge Stats&Facts i Publications { FBC Staff i BCIS Site Map Links Search Business >> 4� 1_" user:PumAPProyal Professibnal Product Approval Menu>Product or Application Search>Application List Search Criteria ✓ �; " r.,may, Refine Search . I Code Version 2014 FL# 1'24'-l:ly Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results FL# IType Manufacturer Validated By Status - - -- --- -- ------- --- --r - ----- - -+ FL13241-R2 Revision_Custom Window Systems Inc. Steven M.Urich,PE Approved History FL#:FL13241.1 1(717)932-8500 Model:SGD-8900 PVC Sliding Glass Door. 1 Description:SGD-8900,Sliding Glass Door,16080,OXXO,Non-Impact. i Category: Exterior Doors j Subcategory:Sliding Exterior Door Assemblies j -— ---- -- -- -..--- ------..._._..... -i 'A roved b DBPR.A - - --_.. _. pp y Approvals by DBPR shall be reviewed and ratified by the POC add/or the Commission if necessary. Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(l),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product F055 Approval Accept ......��r� s: El M sccurlty%i ri gic.ti 1 of 1 02/09/2016 11:47 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=w... yK ,.�'4 E.S fir. i! ^^-_"-'�zrartmprtC eCfS Home Log In 'i User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff eCfS Site Map , Links i Search Business;' @USER: Product Approval Professib�, Public User Product Anproval Menu>Product or Application Search>Application List>Application Detail I' FL 8 FL4091-R7 Application Type Revision Code Version 2014 Application Status Approved Comments Archived V Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala,FL 34474 (352)368-6922 ekoss@cws.cc Authorized Signature Koss Erin ekoss@cws.cc Technical Representative Erin Koss Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352)368-6922 Ext 291 ekoss@cws.cc Quality Assurance Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lucas A.Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M. Urich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL4091 R7 COI EvalReo CWS-154E(SH-8100 NI) Ddf Referenced Standard and Year(of Standard) Standard Year AA MA/W D M A/CSA/101/I.S.2/A440-OS 2005 AAMA/W D MA/CSA/101/I.S.2/A440-08 2008 ASTM E1300-04 2004 PA TAS 202 1994 Equivalence of Product Standards Certified By 1 of 3 02/09/2016 11:50 AM Florida Building Code Online https://www.floridabuilding.org/pr/pi_app_dti.aspx?param=w... Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/09/2015 Date Validated 04/21/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/22/2015 Summary of Products FL# 1 Model,Number or Name Description 1 4091.1 SH-8100 8100 Vinyl Flange/Fin Frame Single Hung Limits of Use Installation Instructions j Approved for use in HVHZ:No 1 FL4091 R7 II CWS-154E(SH-8100, NI).pdf Approved for use outside HVHZ:Yes ; Verified By: Lucas A.Turner 58201 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:+50/-50 Evaluation Reports Other:SH-8100,Max.size 53.125"x 76".Glass complies with ! FL4091 R7 AE EvalRep CWS-154E(SH-8100,NI).pdf ASTM E1300-04. Created by Independent Third Party:Yes t- 4091.2 SH-8100 SH-8100 Vinyl Single Hung,Non-Impact. Limits of Use I Installation Instructions Approved for use in HVHZ:Yes FL4091 R7 II CWS-485B(SH-8100,52x71,NI).pdf j Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:SH-8100 Vinyl Single Hung,OX,Max.size 52"x 71", ( FL4091 R7 AE EvalRep CWS-485B(SH-8100, 52x71,NI).pdf see installation dwgs.for DP.Glass complies with ASTM FL4091 R7 AE Quanex(Mikron)NOA 12-1017 02.pdf j E1300-04. Created by Independent Third Party:Yes 4091.3 SH-8100 Continuous Head&Sill SH-8100 Vinyl Single Hung;Continuous Head&Sill, Non-Impact. Limits of Use Installation Instructions Approved for use in HVHZ:No 1 FL4091 R7 II CWS-4428(SH-8100.74x63 ContHdSl,NI).pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 I Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A 1 Evaluation Reports Other:SH-8100 Cont.Hd.&Sill,Max.size 72 7/8"x 61 3/4", I FL4091 R7 AE EvalRep CWS-4428(SH-8100.74x63. j DP+67.5/-70 psf.Glass complies with ASTM E1300-04. %ContHdSl.NI).odf Created by Independent Third Party:Yes 4091.4 SH-8100 Continuous Head&Sill 1 SH-8100 Vinyl Single Hung,Cont.Head&Sill,Non-Impact. ---- Limits of Use I Installation Instructions Approved for use in HVHZ:No FL4091 R7 II CWS-492B(SH-8100.74x72 ContHdSl,NI).pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:SH-8100 Cont.Hd.&Sill,Max.size 74 1/8"x 72",see , FL4091 R7 AE EvalRep CWS-492B(SH-8100.74x72, chart on installation dwgs.for DR Glass complies with ASTM i ContHdSl,NI).pdf j E1300-04. Created by Independent Third Party:Yes 14091.5 SH-8100 Oriel 8100 Vinyl Single Hung Oriel w/HD Meet. Rail I Limits of Use j Installation Instructions Approved for use in HVHZ:No FL4091 R7 II CWS-293C(SH-8100.52x96, NI).pdf Approved for use outside HVHZ:Yes 1 Verified By: Lucas A.Turner 58201 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+60/-60 Evaluation Reports Other:SH-8100,Max.size 52"x 96",Oriel.Glass complies i FL4091 R7 AE EvalRep CWS-293C(SH-8100 52x96 NI).pdf with ASTM E1300-04. Created by Independent Third Party:Yes Back Next Contact us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send 2 of 3 02/09/2016 11:50 AM Florida Building Code Online https://www.floridabuilding.org/pr/pi_app_dtl.aspx?param=w... electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: El RA Eo M sccurltvm!!'ikws' 3 of 3 02/09/2016 11:50 AM Florida Building Code Online https://www.floridabuildiiig.org/pr/pr_app_lst.aspx 71 �,� �.� ��- F� �,� � � � /'YZ�t �•�� �®fiR BCIS Home Log In i User Registration i Hot Topics Submit Surcharge t Stats&Facts I Publications ; FBC Staff i BCIS Site Map ` Links ! Search I; Business; Professions I l; USER:Puublic UserAppral Reknulatior Product Aonrnval Menu>Product or Application Search>Application List I, _tet.. •_�___ Search Criteria Refine Search Code Version 2014 FL# 13241.1 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL S_earc_h__Re_sults_-Applications .FLA ;Type Manufacturer 'Validated By Status FL13241-R2 Revision I Custom Window Systems Inc. Steven M.Urich, PE!Approved. History 'FL#:FL13241.1 (717)932-8500 Model:SGD-8900 PVC Sliding Glass Door. I Description:SGD-8900,Sliding Glass Door,16080,OXXO,Nan-Impact. Category:Exterior Doors j Subcategory.Sliding Exterior Door Assemblies - — —_..... - -_ —............. __ ...............— --- ___... _ ........ .... _...... 'Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ZA� n =d M wcurih'Lirratfs` f 1 of 1 02/09/2016 11:47 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=w... -I, �.° 09 +• ?�+� � i;.__..>..._.. ..._........ ..__._.._e..._._•_.._.,._....�__._..,.=...-i:;�m-._._..�� V&- ti .l4' _01l,°.- SCIS Home Log In User Registration i Hot Topics l SubmitSurcharge Stats&Facts 1 Publications FBC Staff ' BCIS Site Map Links Search Busines$`�?) Professional �- ��I USER:Public Userroduct al Reaua�ior Product.Approval Menu>Product or Aonlicahon Search>Application List>Application Detall FL# FL13241-R2 Application Type Revision Code Version 2014 Application Status Approved Comments 04/15/2015vd Archived I Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352)368-6922 ekoss@cws.cc Authorized Signature Koss Erin ekoss@cws.cc Technical Representative Erin Koss Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352)368-6922 Ext 291 ekoss@cws.cc Quality Assurance Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer A' Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lucas A.Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M.Urich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL13241 R2 COI EvalReo CWS-4968(SGD-8900 NI)pdf Referenced Standard and Year(of Standard) Standard Year AAMA/W D M A/CSA/101/I.S.2/A440-05 2005 ASTM E1300-04 2004 PA TAS 202 1994 Equivalence of Product Standards Certified By 1 of 2 02/09/2016 11:48 AM Florida Building Code Online https://www.floridabuilding.org/pr/pi_app_dtl.aspx?param=w... Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/14/2015 Date Validated 04/21/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/22/2015 Summary of Products FL# _ Model,Number or Name Description 113241.1 _ SGD-8900 PVC Sliding Glass Door. SGD-8900,Sliding Glass Door, 16080,OXXO,Non-Impact. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL13241 R2 II CWS-496B(SGD-8900,NI).pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-N/A I Evaluation Reports Other:See Installation Detail for DP and Max.Sizes,OXXO, I FL13241 R2 AE EvalRep CWS-496B(SGD-8900,NI).pdf OXO,OX,&X0. Glass complies to ASTM E1300-04. FL13241 R2 AE Ouanex(Mikron) NOA 12-1017 02.pdf L_--_- Created by Independent Third Party:Yes Back Next Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your a-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.`Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: 9", W_�Ek -azc sccuritvmm enc 2 of 2 02/09/2016 11:48 AM SINGLE HUNG - NON-IMPACT GENERAL NOTES: SHOWN w/DIFFERENT OPTIONS 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED WINDOW SYSTEMS J TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC).CURRENT 54 3!8" EDITION. 1900 SW 44TH AVE. MAX OVERALL 54 3/8" OCALA,FLORIDA 34474 FLANGE WIDTH MAX OVERALL 2.GLAZING OPTIONS:(SEE SHEET 2) WWW.CWS.CC 53118" FLANGE WIDTH MAX.UNIT WIDTH 3.CONFIGURATIONS:"O/X'. 4815/16" 53 1/8" 8100 PVC MAX.UNIT WIDTH GLASS DLO 4.DESIGN PRESSURE RATING(SEE SHEET 2): A 4815/16" -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND SINGLE HUNG GLASS DLO GLASS TABLES ASTM E-1300-04. NONIMPACT __ _ -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER 77114" �- INFILTRATION TEST PRESSURE AND GLASS TABLES OVERALL I GLASS" 69 1/2" ASTM E-1300-04. FLANGE O I GLASS MAX HEIGHT DLO OVERALL 33 5/16" 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED N N o F ZE MAX. B B HEIGHT FLANGE O GLASS IN THE DESIGN OF THIS PRODUCT.SEE SHEET 6 FOR ANCHOR o 0 o a o 0 DETAILS. WINDLOAD DURATION FACTOR Cd--'1.6 WAS USED FOR WOOD UNIT 681/4" ANCHOR CALCULATIONS. Y w w w w HEIGHT B MAX w ¢ F ¢ ¢ m 6 UNIT 6.NOT APPROVED FOR IMPACT RESISTANCE.IMPACT PROTECTIVE 3611/16" HEIGHT z z MAX. C 333/8" 303/16" SYSTEM IS REQUIRED IN WIND BORNE DEBRIS REGION. o 26 7/8" m F m m Z SASH X I 6 GLASS MAX X u a u. y O HEIGHT I D DLO SASH IZ /� DOSS 7.ALL FRAMES AND VENTS FULLY WELDED.SMALL JOINT SEAM SEALANT c LL a v LD 6 HEIGHT 4? USED AT FIXED MEETING RAIL AND JAMB. N W $ LL z w Ll a A A C 8.SERIES/MODEL DESIGNATION SH-8100. a ¢ a a a w 6 ❑ ❑ U ❑ cc 46 5/16" 9.THE DESIGNATION X AND O STAND FOR THE FOLLOWING: c w < w a 46 5/16" GLASS DLO X=OPERABLE SASH,O=FIXED SASH ❑ o ❑ ❑ ❑ U GLASS DLO a a a ❑ a w 5 HI SASH ORIEL EQUAL SPLIT 10.SECTION CALLOUTS FROM EQUAL SPLIT ELEVATION APPLY TO ALL " ELEVATIONS IN A SIMILAR LOCATION. w o U m ¢ 0 MAX OVERALL 11.EXTERNAL WEEP SLOT=1/2"x 2-1/2"LOCATED 4"FROM BOTH ENDS. `,�-.0'ORE W�T& FLANGE WIDTH ;�Q•:-v�GElJg .,'P 53 1I8" MAX.UNIT WIDTH ti v t No 53201 1) 481 -+• * '+ GLASS DLO LucasTurner 13 STATE OF :'w 63 5116" O ,� 4u' MAX � F'•.c O R 10 P'•N OVERALL 335/16" 2015-04-03 FLANGE O GLASS 09:55-04:00 .11,/O e,0% HEIGHT DLO � NA;�N�� 62 1/16" Z MAX UNIT 24„ 4/3/2015 HEGHT a /16" MAX XSSLUCAS A.TURNER,P.E. SASH FL PE#58201 HEIGHT 1239 JABARA AVE. NORTH PORT,FL 34288 46 5/16" PH.941-380-1574 GLASS DLO 6 (SHEET DESCRIPTION: 0/40 SPLIT ORIEL j GENERAL NOTES AND ELEVATIONS TABLE OF CONTENTS CONFIG. MAX. UNIT SIZE DESIGN PRESSURE RATING IMPACT RATING ;DRAWN BY: DATE: GENERAL NOTES& 1DP CHARTS&GLAZING DETAIILS.....2 EQUAL. 53-1/8"x 76" NONE BAT 04/29/08 SECTION VIEWS&ALT.FRAME........3 „ SEE COMPARATIVE ANALYSIS (DWG#: REV.: EXTRUSIONS&B.O.M.........................4 5 HI ORIEL 53-1/8" x 68-1/4" CHART, SHEET 2 NONE CWS-154 E ANCHOR SCHEDULE&NOTES.......... 60/40 ORIEL 53-1/8" x 62-1/16" NONE SCALE: SHEET INSTALLATION DETAILS.....................6 1:33.33 1 OF 6 Design Pressures(PSF)with Glass Types A,B,C,or D Unit Sash Unit Widths(in.) Heights(in.) Heights(in.) 23 1/27 27 1/2 29 1/2 31 1/2 35 1/2 39 1/2 41 1/2 43 1/2 47 1/2 51 1/2 53 1/8 WINDOW SYSTEMS J 35 1/2 17 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 1900 SW 44TH AVE. OCALA,FLORIDA 34474 39 1/2 19 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 ww W.CwS.CC 41 1/2 20 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-73.1 43 1/2 21 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-73.4 +50/-70.6 8100 PVC 47 1/2 23 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-68.9 +50/-66.2 SINGLE HUNG 51 1/2 25 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-72.7 +50/-65.2 +50/-62.6 NON-IMPACT 53 1/2 26 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-71 +50/-63.6 +50/-61 55 1/2 27 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-7S +50/-75 +50/-75 +50/-69.5 +50/-62.1 +50/-59.5 �2 N m m 59 1/2 29 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-66.8 +50/-59.5 +50/-57 m N w r N N O H 63 1/2 31 +50/-75 +50/-72.9 +50/-72 +50/-71.6 +50/-71.6 +50/-71.6 +50/-71.6 +50/-71.6 +50/-64.6 +50/-57.3 +50/-54.8 c> o_ o_ a n ¢ 0 0 0 65 1/2 32 1 +50/-73.2 +50/-69.1 +50/-68 +50/-67.4 +50/-67.3 +50/-67.3 +50/-67.3 +50/-67.3 +50/-63.6 +50/-56.4 +50/-53.9 Y w w w w .. 67 1/2 33 +50/-69.8 +50/-65.6 +50/-64.4 +50/-63.7 +50/-63.4 +50/-63.4 +50/-63.4 +50/-63.4 +50/-62.7 +50/-55.5 +50/-53 w ¢ F- ¢ ¢ m 71 1/2 35 +50/-64 +50/-59.7 +50/-58.3 +50/-57.3 +50/-56.5 +50/-56.S +50/-56.5 +50/-56.5 +50/-56.5 +50/-53.9 +50/-51.5 z 74 3/4 36 5/8 +50/-59.9 +50/-55.6 +50/-54.1 +50/-53 +50/-51.8 +50/-51.7 +50/-51.7 +50/-51.7 +50/-51.7 +50/-51.7 +50/-50.4 M ¢ M > 0 76 37 1/4 +50/-58.5 +50/-54.1 +50/-52.6 +50/-51.5 +50/-50.2 +50/-50 +50/-50 +50/-50 +50/-50 +50/-50 +50/-50 N $ zz w z > cc a w, a a O w cr o a w w U w Q 7/8"OVERALL 7/8"OVERALL 7/8"OVERALL 7/8"OVERALL a a a o w > > > a o 1/8"ANNEALED 3/16"ANNEALEDF-1/8"TEMPERED 3/16"TEMPERED w o U m ¢ Z 5/8 "AIRSPACE 1/2"AIRSPACE 5/8"AIRSPACE 1/2"AIRSPACE 0 1/8"ANNEALED 3/16"ANNEALED 1/8"TEMPERED -3116"TEMPERED ,�� P10RE4y�'��i� 41 SIKAFLEX 552 OR Ci v S's . •.' SIKAFLEX 552 OR SIKAFLEX 552 OR SIKAFLEX 552 OR 46 PURFECT GLAZE"H„ 46 PURFECT GLAZE"H" 46 PURFECT GLAZE"H" 46 PURFECT GLAZE"H" No 58201 L-7 ? 1/2"GLASS BITE 1/2"GLASS BITE 1/2"GLASS BITE 112"GLASS BITE :9 STATE OF CC1 ,',',sf ONA1�N•,,` 0 4y201 O O LUCAS A.TURNER P.E. LLq o , FL PE#58201 GLASS TYPE A GLASS TYPE B GLASS TYPE C GLASS TYPED 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: COMPARATIVE ANALYSIS AND GLAZING DETAILS DRAWN BY: DATE: BAT 04/29/08 DWG C: REV.: NOTE: CWS 154 E IF SIZE INTENDED IS NOT SHOWN,USE NEXT LARGER SIZE. SCALE: SHEET 1:1 2OF6 INTERIOR WINDOW SYSTEMS � 1900 SW 44TH AVE. OCALA,FLORIDA 34474 WWW.0 W S.CC 45 32 54 1 38 13 35 32 4 45 8100 PVC 70 � � � -I NSINGLE ON IMPACT 0 45 j 1 �— oo N N oo O F- m o o c1� 2 < 14 39 0 � wwww } 3 15 53 1 65 66 63 19 4 w < F- < < m SECTION B-B 53 NOTE:LEFT SIDE SHOWS FIXED SECTION VIEW, um o LL i O RIGHT SIDE SHOWS SASH SECTION VIEW. N Q N ¢ m Z w WUW a cc W 14 a a o a w a 39 w w o w ¢ 2 28 w ¢ w ¢ 40 a j ❑ 5 34 INTERIOR w ❑ U m < O 9 a8 Pp10 RE W%latIllorlit"t' sz G 8 ;Op.-;�;GENS�...Q 4 v: No 58201 y�� 29 t trz 16 64 '00 FTATE OF 66 10 9110 N A; 6 46 ir 48181s O 4/3/2015 33 LUCAS A.TURNER,P.E. 2 FL PE#58201 1239 JABARA AVE. 30 �o NORTH PORT,FL 34288 as PH.941-380-1574 SECTION C-C SHEET DESCRIPTION: ALTERNATE FIN FRAME SECTION A-A SECTION VIEWS DRAWN BY: DATE: BAT 04/29/08 DWG#: REV.: NOTE: ITEMS NOT SHOWN FOR CLARITY: CWS-154 E 20,23,25-26,31,36,37,44,51-52,55-56,64,67-68 SCALE: SHEET 1:2 3OF6 PARTS LIST FRAME CORNER ITEMI PART# DESCRIPTION VENDOR MATERIAL CONSTRUCTION 1 1 H-6031 IMain Fr.,SH,w/Fig.,PVC,Head Mikron Vinyl I 1 15/16" 23/16" ��f(YfJM1U/CVW/UUIY L�(�(� 2 H-6031 Main Fr.,SH,w/Flg.,PVC,Sill Mikron Vinyl 69 WINDOW SYSTEMS 3 1 H-6031 IMain Fr.,SH,w/FIg.,PVC,L.Jb. Mikron Vinyl 1900 SW 44TH AVE. OCALA4 H-6031 Main Fr.,SH,w/Fig.,PVC,R.Jb. Mikron Vinyl 70 6 WWW. FLORIDA 3¢474 ^ WWW. W S.CC 5 H-1836 Meet.Rail,Fxd. Keymark Alum t 5/e" ^J 1 5/8" 7 1/16" 8 H-6027 Sash Meet.Rail,PVC Mikron Vinyl 39/16" I 1/16.. 1116" kk 9 H-1497 Reinf.Sash Meet.Rail Keymark Alum L 8100 PVC 10 H-6028 Sash Bottom Rail,PVC Mikron Vinyl CORNER WELD 12 H-6004 Sash Side/Top/Bot.Rail Mikron Vinyl PVC SASH BTM.RAIL PVC SASH MTG.RAIL (ALL SB ES) SINGLE HUNG 13 S-1498 Reinf.S.B.R./S.S.R Keymark Alum �1" H-6028 H-6027 NON-IMPACT 14 S-6064 Glz.Bd.,7/8",Fxd.,Horiz. Mikron Vinyl 15 S-6064 Glz.Bd.,7/8",Fxd.,Vert. Mikron Vinyl PVC FRAME FIN a 16 S-6064 IGIz.Bd.,7/8",Sash,Horiz. Mikron Vinyl H-6026 � o 0 17 S-6064 Glz.Bd.,7/8",Sash,Vert. Mikron Vinyl N 21 CO o r 3 0 0 o c1 0 0 18 S-6013 Scrn.Adapt.,w/Nib,PVC,Horiz. Mikron Vinyl 1 1/2" 19 S-6014 Scrn.Adapt.,PVC,Vert. Mikron Vinyl 3118" -I 1 3/16" t w w w w 20 S-6029 Sash Stop/Filler,PVC,Vert. Mikron Vinyl 1 5 w ¢ H ¢ ¢ m 24 P-2190 Balance BSI 2 1 FIXED MEETING RAIL Z (A 25 P-3059 Sash Cam,PVC BSI Plastic 3 2118" 1116 SCREWED TOGETHER WITH U� o m N Z 1L OUTERFRAME w ¢ w W O 26 P-3046 Take Out Clip BSI SS 4 211/16" a ¢ U 27 P-3783 Lock,Impact,PVC Interlock fns" � 1/16" $ ¢ R LL Z > w 28 P-4069 Keeper,Impact,PVC Interlock Zamac o w w a w 0 30 P-4479 Weep Cover w/Flap Gaer PlasticL 1/8" o w a 0 o a 32 P-3429 Wstp.,0.270 x.187 back FinSeal,Gray Ultrafab PVC SASH SIDE RAIL FIXED MTG.RAIL w w w o w cc 33 P-3429 Wstp.,0.270 x.187 back FinSeal,Gray Ultrafab H-6004 H-1836 a Q a w a 34 P-3429 Wstp.,0.270 x.187 back FinSeal,Gray Ultrafab PVC FRAME FLANGE a a a o a w H-6031 a O 35 P-3429 Wstp.,0.270 x.187 back FinSeal,Gray Ultrafab 36 P-3429 Wstp.,0.270 x.187 back FinSeal,Gray Ultrafab w o U m ¢ z 37 P-4638 #8 x 2-1/2 PH Mod.Truss Type A,Tek 2 Ajax Steel t t/e" 1 1/8" 1 3 8" %W111111" 38 P-3768 #8 x 0.625 Ph PH SMS Hub City Steel 5/t s" 1/2" ``��� P<tORE4y T�i4i 39 P-4051 W #8 x 1.250 Ph FH TEK,Wht. Hub City Steel 20 : `'•'• L ' 19 1g 13!16.. ,C�P�.�vGENSF•.�q�•: 40 P-4264 #8 x 3/4 FH PH w/#6 Head,TEK,Wht Hub City Steel 1/16' 44 1 P-3342 ISeam Sealer,SM-5504 Schnee 1/16" 1/16" No 58201 45 1 P-3752 jCap Plug,1/2"Hale M&M Nylon PVC SCREEN SUPPORT PVC SCREEN CATCH PVC SASH STOP 46 P-3438 Sikaflex 552 or Purfect Glaze"H" Sika/Henkel S-6014 S-6013 S-6029 �' a E 48 P-3352 ISet.Blk.,85 Dur.,1/8"x 5/8"x 2"Lg. F.Lowe Rubber STATE OF 51 P-3881 Temporary Lbl.(NFRC/DP) 'q�(v` ct O R 1�A:N_�� 52 P-3613 CWS Lbl.(logo) Pro Label 3/a" TJ SS/ONA� 53 Glass,Fixed(See Sheet 3) 54 Glass,Sash(See Sheet 3) 3/t6 1/a" �- 55 P-3281 Spacer(see sheet 3) Duraseal 1" 9 73 to Z� 56 P-3281 Spacer(see sheet 3) Duraseal � 1/16" T 7/6 15 4/3/2015 t/16" } 16 62 P-3218 Screen Frame,Horiz. Allmetal Alum REINF.SBR/SSR t LUCAS A.TURNER,P.E. 63 P-3218 Screen Frame,Vert, Allmetal Alum REINF.SASH MTG.RAIL FL PE#58201 64 P-3321 Screen Frame Comer Key Allmetal Plastic H-1497 S-1498 PVC GLAZING BEAD 1239 JABARA AVE. 65 P-3581 Screen Cloth,18 x 16 Fiberglass Bettervue Fiberglass S-6064 NORTH PORT,FL 34288 66 P-3228 Screen Spline,.155 Dia.,Blk. Dapa Vinyl PH.941-380-1574 67 P-3029 Screen Pull Tab Summit Alum 1/2" 9/16" SHEET DESCRIPTION: 68 P-3033 Screen Spring,SS A.Screen SS 3/16 � 3.. � 71116" 69 H-6026 Main Fr.,SH,w/Fin.,PVC Mikron VinylBOM AND EXTRUSIONS 70 P-3113 Screw Support for PVC T.Plastics Nylon � 0 1 5/16"71 S-6063 Fixed Rail Cover Mikron Vinyl I 'DRAWNBY: DATE: SCREW SUPPORT L BAT 04/29/08 P-3113 DWG#: REV.: PVC FIXED RAIL COVER CWS 154 E LINE ITEMS NOT USED: NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. S-6063 SCALE: 6-7,11,21-23,29,31,41-43,47,49-50,57-61 SHEET 1:8 40F6 cstuWINDOW SYSTEPIS 1900 SW 44TH AVE. 0 J MAX.O.C.(TYP.) 4"MAX.(TYP) 8"MAX.O.C.(TYP.) OCALA,FLORIDA 34474 6"MAX.(TYP.) 4"MAX.(TYP.)� SEE NOTE 2 WWW.CWS.CC 6"MAX.(TYP.) SEE NOTE 2 FT 8100 PVC 6., SINGLE HUNG MAX O.C. NON-IMPACT O (TYP.) O MAX.O.C. o 0 (TYP.) INSTALLATION N N o F- THRU FRAME ANCHOR ANCHORS TYP. 0 0 o a o 0 MEETING RAIL AT FIXED MEETING RAIL CENTERLINE (TYP.) L w w w w 4"(TYP) � ❑ W ❑ ❑ } II I w QF 0 0 m 4"(TYP) V V x m F m n x Z LL 6 LL } a o Q V (q INSTALLATION LL ANCHORS TYP. ^ N N a LL Z w 4 u w w ¢ a w 0_ a ¢ a a~ o a_ w O w U w (r Q ¢ w ¢ U a ANCHOR LAYOUT-(FLANGE) ANCHOR LAYOUT-(FIN) �a i a o a W w ❑ () 0 0"NORE 4j I`TG No 58201 NOTES: 0. /STATE OP •:�� 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.SILL ANCHOR SPACING SAME AS HEAD. 2.SHIM AS REO AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. Y�Z_' 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 6. 4//3-/2015 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E. FILPE 01 BE PROTECTED TO PREVENT REACTION. # A 123399 JABARAVE.A 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 6. PH.941-380-1574 SHEET DESCRIPTION: 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE-1X BUCKS ARE ANCHOR SCHEDULE AND OPTIONAL. NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. DRAWN BY: DATE: 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. BAT 04/29/08 SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. DWG x: REV.: 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: CWS-154 E FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS),FMA/AAMA/WDMA 300(EXTERIOR DOORS) SCALE: SHEET 1.25 5 OF 6 MIN.EMBEDMENT /( rJ/7(�9 //l�T�f1()• TYPICAL HEAD ANCHORAGE SEE TABLE 1I SUBSTRATE lllU41NJ(Yl4/�UU(1•L�//�` L BY OTHERS WINDOW SYSTEMS MIN.EDGE DIST. 1/4"MAX.SHIM SEE TABLE 1 MIN.EDGE DIST. SUBSTRATE SEE TABLE 1 SEE TABLE 1 BY OTHERS 1900 SW 44TH AVE. SUBSTRATE BY OTHERS 1/4"MAX.SHIM _ SEE TABLE 1 www.OCALAFLORIDA 34474 WWW.CWS.CC SEE TABLE 1 MIN.EDGE DIST. MIN.EMBEDMENT SEE TABLE 1 PERIMETER SEALANT SEE TABLE 1 BY INSTALLER INSTALLATION ANCHOR 8100 PVC INS DE AND OUT SEE TABLE 1 SINGLE HUNG SEALANT BEHIND C� SEE TABLEDMENT NON-IMPACT FLANGE BY INSTALLER 1/4"MAX.SHIM 1 000 PERIMETER SEALANT a n W PERIMETER SEALANT BY INSTALLER o 6 25 cls o BY INSTALLER INSIDE AND OUT INSIDE AND OUT INSTALLATION ANCHOR Y w LL w w INSTALLATION ANCHOR SEALANT BEHIND SEE TABLE 1 W o w ❑ < } w ¢ r ¢ ¢ m FLANGE BY INSTALLER SEALANT BEHIND SEE TABLE 1 � FIN BY INSTALLER v o v N Z / n 1 HORIZONTAL SECTION / l HORIZONTAL SECTION m a u°7 > O 6 TYPICAL JAMB ANCHORAGE 6 TYPICAL FIN ANCHORAGE ^v 2 c a o Ln HEAD AND SILL SIMILAR FOR FIN INSTALLATION . $ Z¢ m Z > W a w a a O W o a w w w V w cc U 1/4"MAX.SHIM o 0 0 0 o U SEALANT BEHIND > > > a FLANGE BY INSTALLER 0 W a c m Q 0 PERIMETER REEALANT EMBEDMENTt1IBYINSTALSE TABLEI {1DREI/ INSIDE AND OUT " T•L P:-BOENS .�i �g No 58201 P SUBSTRATE BY OTHERS t * :i- SEE TABLE 1 MIN.EDGE DIST. = SEE TABLE 1 gib: :ate �A1 VERTICAL SECTIONr90 NATE OF :4u 6 TYPICAL SILL ANCHORAGE �y�F••. p R 1 P•�_�` 0,S"? TABLE 1:APPROVED INSTALLATION FASTENERS 42015 FRAME TYPE SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. LUCAS A.TURNER,P.E. FLANGE CONCRETE(2.0 KSI MIN.) 3/16"ITW TAPCON 1" 1-1/8" FL PE#58201 PERIMETER SEALANT 1239 JABARA AVE. FLANGE HOLLOW OR GROUT-FILLED CMU(117 PCF MIN.) 3/16"ITW TAPCON 1" 2" BY INSTALLER NORTH PORT,FL 34288 FLANGE CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" 1" INSIDE AND OUT PH.941-380-1574 D HORIZONTAL SECTION FLANGE GROUT-FILLED CMU(ASTM C-90) 3/16"ELCO ULTRACON 1-1/4" 2-1/2" 6 BOX FRAME INSTALLATION SHEET DESCRIPTION: FLANGE 2X MIN.SOUTHERN PINE(G=0.55) 3/16"ITW TAPCON 1-3/8" 7/8" SIMILAR FOR SILL AND JAMBS FOR BOX INSTALLATION OR ELCO ULTRACON I INSTALLATION DETAILS FLANGE 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8" FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, DRAWN BY: DATE: 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HILTI KWIK-FLEXOR ITW FULL THREAD UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: FLANGE 7/16" BAT 04/29/08 (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED DWG#: REV.: 1/8"ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. FLANGE 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" 7/16 PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS CWS-154 E FIN 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-1/2" 1/2" SHOWN FOR FLANGE WINDOWS. SCALE' SHEET 1.2 60F6 MIAMNQADE MIAMI-DADE COUNTY i PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidad&gov/economy Quanex Building Products,Inc. 1034 Sixth Avenue North Kent,WA 98032 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ (in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION:The approved White Rigid PVC Exterior Extrusions for Windows and Doors are to be produced by Extruders Licensees in"AAMA Certification Programs for rigid PVC Extrusions".The extrusions shall meet ASTM D 4726,classification(ASTM D 4216) 1-10154-33-0000, 1-20131-13-0000 or 1-40131-13 and the following properties. Description Test Properties Rate of Burning ASTM D-635 Class C 1 Self Ignition temperature ASTM D-1929 925°F>650 Average Smoke Density Rating ASTM D-2843 43%<75 Flame Spread Index , ASTM E-84 26.2<75 Tensile Strength(Difference: *Exposed&Unexposed) ASTM D-638 4.98%< 10 *Exposed per Section 2605.2 of The Florida Building Code. MISSILE IMPACT RATING:None This NOA revises NOA#11-0830.09 and consists of pages 1 and 2,as well as evidence page E-1. The submitted documentation was reviewed by Carlos M.Utrera,P.E. 13NOA No: 12-1017.02 MIAMFWID �0) Expiration Date:December 26,2016 ADE COUNTY ���_111 Approval Date:February 7,2013 Page 1 M® MIAMI-DADE COUNTY • PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Quanex Building Products,Inc. 1034 Sixth Avenue North Kent,WA 98032 LIMITATION: This approval does not include an evaluation of structural performance of this component. Test reports and other required documents shall be submitted to Dade County Product Control; showing that the systems using this PVC Extrusion will resist the loads according to Chapter 16 of the F.B.C., in.order to issue a specific product approval for the system. LABELING: Each carton containing certified extrusions shall be labeled with the AAMA PVC Extrusion Certification Label with the extruder name, city,state and"MDCA". In addition,(a)each Certified Extrusion shall be labeled every 4 ft or less on the underside with the Extruder Code and"MDCA"or(b) each finished product assembly shall be labeled with a permanent label and/or stamp with the Extruder Code and"MDCA". RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. O!f X13 NOA No: 12-1017.02 MIAMWIADECOUNTY Expiration Date:December 26,2016 JAPPR041)= Approval Date:February 7,2013 Page 2 Ouanex Building Products,Inc. NOTICE OF ACCEPTANCE: EVIDENCE PAGE A. DRAWINGS 1. None. B. TESTS "Submitted under AAMA Master File#98-0036" 1. Test report on Rate of Burning, Ignition Temperature, Density of Smoke, Surface Burning Characteristics,Accelerated Weathering and Tensile Properties Test of"PVC Extrusions from 5 different manufacturer" selected by AAMA",prepared by ETC Laboratories,report#ETC 97-264-40910,dated 04/21/1998, signed and sealed by J. L. Doldan,P.E. C. CALCULATION 1. None D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATION "Submitted under AAMA Master File#12-1037" 1. Procedural Guide for the AAMA Fenestration Exterior Thermoplastic Profile Certification Program(AAMA 109-11). 2. Voluntary Specification for Rigid Polyvinyl Chloride (PVC)Exterior Profiles (AAMA 303-08). 3. Current list of AAMA Fenestration Exterior PVC Profile Certified Licensees. F. STATEMENTS "Submitted under AAMA Master File#12-1037" 1. Statement letter of code conformance to 2010 FBC issued by Turner Engineering& Consulting, Inc., dated 04/25/2012, signed and signed by Lucas A. Turner, P.E. 2. Standards' equivalency report issued by Turner Engineering&Consulting, Inc., dated 04/25/2012, signed and signed by Lucas A. Turner,P.E. 3. No financial interest issued by Turner Engineering & Consulting, Inc., dated 04/25/2012, signed and signed by Lucas A. Turner, P.E. G. OTHERS 1. Letter stating that Mikron Industries,Inc. is a wholly owned subsidiary of Quanex Building Products, Inc., dated 10/10/2012 and signed by David C. Gadd. "Submitted under NOA #06-1220.01" 2. Member acknowledgement letter issued by Mikron Industries, Inc. - Spectus Systems, on 08/03/2001 and signed by Douglas W. Allen. 3. Component Release Letter issued by American Architectural Manufachirers Association on 09/07/2001 and signed by Dean Lewis. OZ G!f 2Gl3 Carlos M.Utrera,P.E. Product Control Examiner NOA No 12-1017.02 Expiration Date:December 26,2016 Approval Date:February 7,2013 E-1 SLIDING GLASS DOOR - NON-IMPACT GENERAL NOTES:1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED VVINOOW SYSTEMS TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC).CURRENT EDITION AND IS RATED FOR USE IN THE HIGH VELOCITY HURRICANE 1900 SW 44TH AVE. ZONE(HVHZ). OCALA.FLORIDA 34474 www.cws.cc 2.GLAZING OPTIONS:(SEE SHEET 2) 3.APPROVED CONFIGURATIONS INCLUDE BUT ARE NOT LIMITED TO: 8900 PVC SLIDING 190.125 MAX.OVERALL WIDTH "XO","OX"."OXO"."OXXO-. GLASS DOOR 485/8"MAX. 41112" 4.DESIGN PRESSURE RATING(SEE SHEET 2): NON-IMPACT PANEL WIDTH A GLASS DLO -NEGATIVE DESIGN LOADS BASED ON.TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04. -- - -- - POSITIVE DESIGN LOADS BASED ON.TESTED PRESSURE.WATER n �; I INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E-1300.04. 95 112" o o MAX. 5.ANCHORAGE:THE 33 V3%STRESS INCREASE HAS NOT BEEN USED Y OVERALL IN THE DESIGN OF THIS PRODUCT.SEE SHEET 7 FOR ANCHOR w! } B DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD HEIGHT B w H m O X X O 85 ANCHOR CALCULATIONS. 1n y B GLASS m ml Z 7 DLO 6.NOT APPROVED FOR IMPACT RESISTANCE.IMPACT PROTECTIVE LL LL I PANEL L I SYSTEM IS REQUIRED IN WIND BORNE DEBRIS REGION. o 0 9 HEIGHT 7 I 7.ALL FRAMES ARE PROCESSED AND SCREWED TOGETHER. VENTS w w i O cc I ARE FULLY WELDED. a Q. iL B.SERIES/MODEL DESIGNATION SGD-8900. < a 1III ui 0 A ALU 7 9.THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING: > > o X=OPERABLE SASH.O=FIXED SASH m ¢ O 10.SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS IN A SIMILAR i+ z 145 1/8„ MAX.OVERALL WIDTH 95 1/2" MAX.OVERALL WIDTH LOCATION. `�Hp10REW,T��,G 48_518"MAX. 411/2" 48 5/8„ MAX. 41 1/2" 11.WEEP SLOTS-114"x 1-1/4"LOCATED 3"FROM BOTH ENDS. ;+`GP�'•��G PANEL WIDTH GLASS DLO PANEL WIDTH GLASS DLO ;F�: �v. No 58201 .P: Lucas A.Turner 13 •a' 9`.,?_112_ - :9 STATE OF L, MAX. � 2015-04-03 O.o••,F ?. �' OVERALL OVERALL I '�i,FpS�.. R �G,�•� 15:32-04:00 C O X O C I HEIGHT D D ""ONAi++ MAX. O X Y PANEL HEIGHT 85 7/8" 8.". 4/3/2015 GLASS MAX. GLASS LUCAS A.TURNER,P.E. DLO PANEL DLO FL PE#58201 HEIGHT 1239 JABARA AVE. NORTH PORT,FL 34288 L- PH.941-380-1574 - SHEET DESCRIPTION: GENERAL NOTES AND TABLE OF CONTENTS ELEVATIONS GENERAL NOTES&ELEVATIONS.....1 MAX. PANEL SIZE DESIGN PRESSURE RATING IMPACT RATING DRAWN BY: DATE: GLAZING DETAILS&DP CHART........2 SEE COMPARATIVE ANALYSIS ADE 10/30/09 SECTION VIEWS..............................3-4 48-5/8" x 93" NONE DWO#: REV.: BOM&EXTRUSIONS...........................5 CHARTSHEET 2 CWS-496 B , ANCHOR SCHEDULE&NOTES..........6 GALE: INSTALLATION DETAILS.....................? MAX.OF FOUR(4)PANELS IS ALLOWED AS LONG AS INDIVIDUAL PANELS DO NOT EXCEED PANEL SIZE AS SHOWN. SHEET 1:40 1 OF7 Width 59.5 71.5 84 95.5 91 1 109 1 126 145 118 142 168 190 ( C4(!U • Panel Size 30.625 36.625 42.875 1 48.625 30.625 36.625 1 42.25 48.625 30.625 36.625 42.625 48.6251900 SW 44TH AVE. �"1iNDOW SYST'tt?5 Unit Configuration OX,XO OXXO OXXO OXXO OXO OXO OXO OXO OXXO OXXO OXXO OXXO OCALA,FLORIDA 34474 Height Glass Type www.cws.cc 80 A -90/+60 -90/+60 -82.2/+60 -72/+60 -90/+60 -90/+60 -82.2/+60 -72/+60 -90/+60 -90/+60 -82.2/+60 -72/+60 84 A -90/+60 -87.3/+60 -78.4/+60 -68.5/+60 -90/+60 -87.3/+60 -78.4/+60 -68.5/+60 -90/+60 -87.3/+60 -78.4/+60 -68.5/+60 8900 PVC SLIDING 90 A -90/+60 -80/+60 -71.6/+60 -64/+60 -90/+60 -80/+60 -71.6/+60 -64/+60 -90/+60 -80/+60 -71.6/+60 -64/+60 GLASS DOOR 96 A -85.3/+60 -73.8/+60 -65.8/+60 +60/-60 -85.3/+60 -73.8/+60 -65.8/+60 +60/-60 -85.3/+60 -73.8/+60 -65.8/+60 +60/-60 NON-IMPACT � : izz "a� w Ma,Ia n o LL w 'Im UU Z 1" OVERALL w m O a o (A 3/16"TEMPEREDN N Z cc ¢IO w II cc 5/8" AIRSPACE Wa i l a 3/16"TEMPERED a ¢ U ILU > > o SIKAFLEX 552 OR 13 PURFECT GLAZE"H" m ¢ z %0 PNyORE W "flip,��, 30 D 13/16" GLASS BITE v�P, No 56201 -P =•O: ;ate �IDSTATE OF �z .0- OR l0�'��2• 23 `� / 4/3/2015 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: MAX. COMPARATIVE ANALYSIS Dr SILL RISER POSITIVE DP AND GLAZING DETAIL NONE 60 DRAWN BY: DATE: GLASS TYPE A 1737 60 ADE 10/30/09 INSTALLATION WITH NO SILL RISER DWG 0: REV.: ALLOWED ONLY WHERE WATER CWS-496 B NOTE: IF SIZE INTENDED IS NOT SHOWN,USE NEXT LARGER SIZE. INFILTRATION RESISTANCE IS NOT SCALE: SHEET REQUIRED. 1:1 2 OF 7 26 ��� 24 18 255 21 22 20 16 WINDOW SYSTEMS _j 1900 SW 44TH AVE. TT OCALA.FLORIDA 34474 ❑ _j 8900 PVC SLIDING ❑ a 8 o a ❑ GLASS DOOR NON-IMPACT ❑ o _ _. _ o0 0 __ _- e ❑ � B!t� c0 F co 0.< 1 5 30 33 6 19 2 20 9 19 1 ... p ca SECTION VIEW B-B co LL; 0 I U) N Qc; cc z W cc O Lu W:. (L (L 2 a Oil OC iu) :w r 1I 4 cc ILS � 23 t's stalmill" f4l Ottp1ORBV A 12 E Ns Zj 13 No 58201 'P. 33 ZI),. STATE OF 13 4/3/2015 LJ 12 LUCAS A.TURNER,P.E. A, 4 FL PE#58201 1239 JABARA AVE. 15 NORTH PORT,FL 34288 3 PH.941-380-1574 (2), 14MAX. SHEET DESCRIPTION: 31 9 SILL RISER POSITIVE DP SECTION VIEWS 14 NONE 60 Oxxo 1 7 1737 60 DRAWN BY: DATE: ADE 10/30/09 3 INSTALLATION WITH NO SILL RISER ow G-#. TE7.: SECTION VIEW A-A ALLOWED ONLY WHERE WATER CWS-496 B INFILTRATION RESISTANCE IS NOT REOUIRED. SCALE: SHEET 1:2.67 3 OF 7 WINDOW SYSTE?S 1900 SW 44TH AVE. OCALA.FLORIDA 34474 www.CwS.CC 1 12 13 5 16 14 0 2 21 23 4 8900 PVC SLIDING -D GLASS DOOR NON-IMPACT ❑ _ _ O w H CO U U Z O Q a o D N NIZ 26 16 5 30 2 8 9 19 w w ¢ SECTION VIEW C-C o o 9: 2 Q'U W � j O m <10 ��%��NORE 26 18 25 24 23 7 `�� o No 58201 ❑ %1D STATE OF •� ❑ � c 4(/ p a O 8 +i+COS........Cp LA oPRaJ 4/3/2015 �Z LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. 1 �5 30 33 6 19 NORTH PORT,FL 34288 PH.941-380-1574 SECTION VIEW D-D SHEET DESCRIPTION: SECTION VIEWS OXO&OX DRAWN BY: DATE: ADE 10/30/09 DWG#: REV.: CWS-496 B NOTE:VERTICAL SECTION SIMILAR FOR ALL CONFIGURATIONS,SEE SHEET 3 SCALE: SHEET 1:2.63 4 OF 7 PARTS LIST ---- --------------------- --------------- FRAME CONSTRUCTION --------------- 5 15/16" �y ITEM PART N:9:1-CRIPTION VENDOR MATERIAL �'I " 2^� 1 H-6042 FRAME.MAIN,SGD MIKRON PVC I 3/4"- 2 S6040 THRESHOLD/FILLER, SGD MIKRON PVC 1 32 WINDOW SYSTEMS 3 1 S6038 ISUPPORT BLOCK,FIXED,SGD MIKRON PVC 1900 SW 44TH AVE. 4 H6032 I PANEL TOP/BOTTOM RAIL, SGD MIKRON PVC 17/8" r} O 1314" OCALA.FLORIDA 34474 5 H-6032 PANEL SIDE RAIL,SGD MIKRON PVC I LLII ❑rtO� 1!8„ I055 WWW.CWS.CC 6 H6033 PANEL,INTERLOCK.FO . LD MIKRON PVC L u u u L —— — 7 1 H6034 JPANEL.INTERLOCK,OPERABLE MIKRON PVC 8 H-6035 TER INTERLOCK,SNAP-ON. MIKRON PVC TER S- S PVC OUFRAME PVC WELD SUPPORT 8900 PVC SLIDING 9 H-6043 ASTRAGAL,SGD, MIKRON PVC H-604GLASS DOOR 10 P-3142 ROLLER,TANDEM(SGD,PLATED STEEL) STEEL 46 FRAME CORNERS 11 P-3342 SEAM SEALER,SM-5504 17/8"-'{ 17/8"� 17/8"-�I SCREWED TOGETHER NON-IMPACT 1'10 12 P-3352 SETTING BLOCK,85 DUR.1/8"X7/8"X2" RUBBER I 13 P-3438 SIKAFLEX552 OR PURFECTGLAZE"H" ISIKAIHENKEL D 7 D 6 4 ^ 'I 14 P-3492 WSTP.,0.270 X.187,BACK FINSEAL,GRAY 5 VENT CONSTRUCTION ^ o w N f�7 F 15 P-3539 #8 X3/4"QUAD PHILIPS.TEK ZINC I o o 16 1 P-3557 1#10 x 2,HEXHEAD,TEK ZINC 3 9/16" 3 9/16" 3 9/16" g w } 17 P-3752 CAP PLUG,1/2"HOLE NYLON L22 P•3767 #10 X 1'HEX WASHER HEAD,TE ZINC 1/8" w LU m P-3789 LOCK&HANDLE KIT,PVC,SGD STEEL 1/8" v v Z P-3792 3/4"KEEPER STEEL 1/8" [� \ LL LL O P-3793 MORTISE LOCK STEEL y a o (A LJ P-4136 #10 x 2,PAN HEAD PHIL,SMS N N Z LuPVC PANEL INTERLOCK PVC PANEL INTERLOCK PVC PANEL LOCKSTILE s ¢ Lu S•1590 REINFORCEMENT,PVC SGD,PANEL KEYMARK ALUM VENTS FULLY WELDED w w H-6034 H-6033 H-6032 a a S-1591 REINFORCEMENT,ALUMINUM,SGD,PAN KEYMARK ALUM 1:10 S-1618 FIXED PANEL COVER KEYMARK ALUM w w Q ! U 26 S-1597 COVER,FIXED PANEL CLIP KEYMARK ALUM 1 5/8"-1 ao o w 27 S-1655 PANEL TRACK,ALUMINUM,SGD,SILL KEYMARK ALUME 2 1/8"-� Z) � p 23 r 1 518" 7!16" 28 S-1726 REINFORCEMENT,ASTRAGAL,SGD KEYMARK ALUM 050 30 29 S-1737 HIGHRISE SILL,ALUMINUM KEYMARK ALUM �- 24 m ¢ z 115!16" 15/16" 13/16" 27 1118" 30 56037 GLAZING BEAD 1.00",SGD MIKRON PVC 1/16" t 31 S-6041 CK,SCREEN.SGD MIKRON PVC 32 S-6046 SUPPORT WELD,SGD MIKRON PVC 1/8 REINFORCEMENT ROLLER TRACK PV ZING BEAD �`�,p°',P......... DE NS'TGQ�'� 33 GLASS SEE SHEET 2 S-1591 S-1655 S-6037 -V F ?�% REINFORCEMENT S-1590 v. No 58201 •11 5 1/16" 2"_ 1/2 =v' " O STATE OF .:4L, /U= 21/16" �� 11/16" 9 28 5 26 8 29ii���s•C081CP��2�� % (� 3 3/8" D I I 4 318" 3 1/16" 2 5/8" 3 3116„ � 2 13/16” O O Q 1!16" 4/3/2015 O O 1/16" LUCAS A.TURNER,P.E. 1/16" FL PE#58201 J 1239 JABARA AVE. HIGHRISE NORTH PORT,FL 34288 ASTRAGAL FIXED PNL CLIP FIXED PNL COVER PVC INTERLOCK SNAP S 1737 PH.941-380-1574 REINFORCEMENT H-6043 S•1618 S-1597 H-6035 SHEET DESCRIPTION: S-1726 5/8" 2 118" 2 3/16. BOM AND EXTRUSIONS —� 9/16" 11/16" 2 DRAWN BY: DATE: LJ ADE 10/30/09 31 1 1/4" 1/16" 1/16„ I DWG k: REV.: — TiCWS-496 B PVC SCREEN TRACK PVC FIXED PANEL LIFT PVC TRACK FILLER SCALE: SHEET NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. S•6041 S-6038 S•6040 1:2 5 OF 7 – --- --- 18" MAX.O.C.(TYP.)------ --- — -- -- ------------------------ VWJM1�])C4lU/L1U(l•� WINDOW SYSTEMS MAX. TYP.) ( 3" (TYP.) 1900 SW 44TH AVE. 6" MAX.(TYP.) -�3" (TYP.) SEE NOTE 2 OCALA,FLORIDA 34474 W W W.0 W S.CC T - - 8900 PVC SLIDING GLASS DOOR L INSTALLATION NON-IMPACT ANCHOR(TYP.) 18' -- tO MAX.O.C. n o w (TYP.) `N Q;a O � D O X X w!, W D7 I U U Z LL car 0 Q O (n N w Z W a a w w a U 0. 0w > > o m ¢ z ANCHOR LAYOUT-(FLANGE) P•�•••NOREIv T. r�r �v� No 58201 ••'gyp Z13 STATE OF 1411 NOTES: :rOo�,°� �.4v� i 1.INSTALL TWO ANCHORS AT EACH INSTALLATION LOCATION.SILL ANCHOR SPACING SAME AS HEAD. 4p�ONA�„ti•�•• 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 114”. USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 7. 4/3/2015 LUCAS A.TURNER,P.E. 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST FL PE#58201 BE PROTECTED TO PREVENT REACTION. 1239 JABARA AVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT, 34288 PH.941-380-1-1574 SPECIFIED IN TABLE 1,SHEET 7. SHEET DESCRIPTION: 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE-IX BUCKS ARE ANCHOR SCHEDULE AND OPTIONAL. NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:2-7116"FOR MASONRY,2-FOR FIXED PANEL CLIPS(ALL SUBSTRATES).1"FOR WOOD AND METAL. DRAWN BY: DATE: 8.WOOD OR MASONRY OPENINGS.BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. ADE 10/30/09 SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 7. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. DWO n: REV.: 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: CWS-496 B FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMANVDMA 250(BOX WINDOWS),FMA/AAMA/WDMA 300(EXTERIOR DOORS) SCALE: SHEET 1:25 60F7 TYPICAL HEAD ANCHORAGE MIN.EMBEDMENT Ml SEE TABLE 12 7/16" MIN.EDGE DIST. 1/4" MAX.SHIM WINDOW SYSTEMS SEE TABLE 1 INTERIOR � 1900 SW 44TH AVE. OCALA,FLORIDA 34474 SUBSTRATE BY OTHERS —f] MIN.EDGE DIST. WWW.CWS.CC SEE TABLE 1 MIN.EMBEDMENTSEE SEE TABLE I 8900 PVC SLIDING GLASS DOOR PERIMETER SEALANT 1/4" MAX.SHIM INSTALLATION ANCHOR �❑ 2 7/16" NON-IMPACT BY INSTALLER SEE TABLE 1 a INSIDE AND OUT u n Q mlF- INSTALLATION ANCHOR INTERIOR �I ) o o p SEE TABLE 1 Y LL w F- 00 co U 0 Z PERIMETER SEALANT BY INSTALLER i m o INSIDE AND OUT SUBSTRATE BY OTHERS ¢ ¢ Q W PERIMETER SEALANT SEE TABLE 1 B HORIZONTAL SECTION a a I F= BY INSICL TALLER a ® 7 TYPICAL JAMB ANCHORAGE w w INSIDE AND OUT DO NOT COVER a a I W WEEP HOLES MIN.EMBEDMENT �'� SEE TABLE 1 SUBSTRATE BY OTHERS m a z SEE TABLE 1 INSTALLAT 'unueee SEETABLEION ANCHOR ``�%0"VAOREby►T���++ SEALANT UNDER SCREW 2 7/18 MIN.EDGE DIST. TWO ANCHORS PER 1/4" .�p`':'�G E Ng'. Q + HEAD BY INSTALLER FIXED CLIP THROUGH SEE TABLE 1 J• to PRE-DRILLED HOLES 19/16" 1—: No 58201 •� Ci) VERTICAL SECTION 7 TYPICAL SILL ANCHORAGE lK(TYP.) '9 STATE OF :�CuZ TABLE 1:APPROVED INSTALLATION FASTENERS LJ 0/ 0 2111 6" ++y�^��`S'-.0 R 10 P�j���� SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. �ONA„Ey��� V CONCRETE(2.0 KSI MIN.) 3/16"[TW TAPCON 1" 3" CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1-3/4" 1" MAX.O.C. ❑ 4/3/2015 HOLLOW OR GROUT-FILLED CMU(ASTM C-90) 3/16"ELCO ULTRACON 1-114" 1" LUCAS 3/16"ITW TAPCON OR FIXED PANEL CLIP FL PE#58201 P.E. 1-318" 2XMIN.SPRUCE-PINE-FIR(G=0.42) 7/8" ELCO ULTRACON NOTE:CLIP ANCHORS 1239 JABARA AVE. 2X MIN.SPRUCE-PINE-FIR(G=0.42) #10 WOOD SCREW 1-3/8" 7/8" MUST BE LOCATED NORTH PORT,FL 34288 16 GAUGE(0.060")MIN. #10-16 HILTI KWIK-FLEXOR rTW FULL THREAD A MINIMUM DISTANCE 1 �a PH.941-380-1574 OF 3"FROM ANY 1/2" STEEL STUD(33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" MAIN FRAME ANCHOR. SHEET DESCRIPTION: 1/8'ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" 1/2 INSTALLATION DETAILS FIXED PANEL CLIP ANCHORS INTO SUBSTRATE BY OTHERS DRAWN BY: DATE: CONCRETE(2.0 KSI MIN.)OR HOLLOW OR 3116"ITW TAPCON 1" 3" FIXED PANEL CLIP DETAIL SEE TABLE 1 ADE 10/30/09 GROUT-FILLED CMU(117 PCF MIN.) DWG a: REV.: FIXED PANEL CLIP ANCHORS INTO C HORIZONTAL SECTION CONCRETE(2.85 KSI MIN.)OR HOLLOW OR 3/16"ELCO ULTRACON 1-1/4" 2-1/2" 7 FIXED PANEL ANCHORAGE CWS-496 B GROUT-FILLED CMU(ASTM C-90) I I SCALE: SHEET NOTE:FIXED PANEL CLIP ANCHORS INTO WOOD OR METAL SHALL FOLLOW THE ANCHOR TYPE,MIN.EMBEDMENT AND MIN.EDGE DISTANCE LISTED IN TABLE 1. 1:2.5 7 OF 7 URNER 1239 Jabara Ave. North Port, FL 34288 ENGINEERING & Ph. 941-380-1574 TCONSULTING, INC. FBPE C.O.A. #29779 Evaluation Report 496B April 18, 2015 Product Description: Series 8900 PVC Sliding Glass Door,Non-Impact, 4'x8' nominal panel size, 3/16 Tempered—Air—3/16 Tempered glass Manufacturer: Custom Window Systems, Inc. 1900 SW 44h Ave, Ocala,FL 34474 Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC Product Approval Rule Chapter 61G20-3.005 (4). This product complies with the requirements of the 5t'Edition(2014)Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report,prepared by Lucas A. Turner,P.E., at 1239 Jabara Ave.,North Port, FL 2) Approval drawing CWS-49613, signed and sealed by Lucas A. Turner,P.E. 3) Test Report NCTL-210-3614-3 and-3A,National Certified Testing Laboratories, Orlando, FL, with test completion date 06/15/2009 a. Testing Performed: TAS 202 1994 (Full 202 performed on 3 identical specimens of 190_1/8"x 95_1/2"size OXXO with Design Pressure +/-60 psf) b. Testing Performed: AAMA/WDMA/CSA 101/I.S.2/A440-05 4) Supplemental Calcs. to support CWS-496B, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-496B. Limitations of Use: This product: • May be used with door heights up to 95_1/2",with 45 5/8"max. panel widths and 41 1/2" x 85 7/8"max. glass DLO sizes • Achieves the design pressures shown in CWS-496B • Is non-impact resistant and requires the use of shutters in windborne debris regions • May be used in the High Velocity Hurricane Zone • Requires 3/16 Tempered—Air—3/16 Tempered glass minimum • Requires Quanex (Mikron)white rigid PVC framing per Miami-Dade NOA 12-1017.02. I have evaluated the framing material in this NOA and find that it complies with the requirements of the 5h Ed. (2014)Florida Building Code for use in this product. Certification of Independence: I do not have,nor do I intend to acquire,nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire,nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. 0'ki,& If Elf" ``Z'Cjcrus 4/18`/2015 u : No 58201 :73 Lucas A. Turner, P.E. FL PE#58201 :SS STATE OF '411 Lucas A. Turner O R t •••GN ` 2015-04-18 '•4 �dNA` ;;•`� 22:16-04:00