Loading...
HomeMy WebLinkAboutWind Load Calculation PARADISE EXTERIORS "Building Our Quality Reputation One Customer At A Time SCC131150472 Pro erty Information IF Building Information Owner: Glenn&Margaret Szczesniak Wind Zone: 170 MPH. Address: 5410 Palm Dr Exposure Category: C Fort Pierce,FL 34982 Minimum Building Dimension: 25 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive--]F Max Negative Number Zone Width(in) IF Height(in) JElevation(ft) Pressure(psf) Pressure(psf) 1 Int 35 49 7 37.4 -40.6 2 Int 35 49 7 37.4 -40.6 ................ ..................... --- ......_._.... .— — — -- 3 Int 35 49 7 37.4 -40.6 4 Int 36 61 7 36.8 -40.0 5 Int 36 61 7 36.8 -40.0 6 Int 36 61 7 36.8 -40.0 7 Int 35 49 7 37.4 -40.6 ......... .... .- __._ _. - -.. ------ ........ . _..._.__ --— -- 8 Int 36 80 7 36.1 39.3 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code. Page 1 of 1