HomeMy WebLinkAboutWind Load Calculation PARADISE EXTERIORS
"Building Our Quality Reputation
One Customer At A Time
SCC131150472
Pro erty Information IF Building Information
Owner: Glenn&Margaret Szczesniak Wind Zone: 170 MPH.
Address: 5410 Palm Dr Exposure Category: C
Fort Pierce,FL 34982 Minimum Building Dimension: 25 ft.
Mean Roof Height: 12 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive--]F Max Negative
Number Zone Width(in) IF Height(in) JElevation(ft) Pressure(psf) Pressure(psf)
1 Int 35 49 7 37.4 -40.6
2 Int 35 49 7 37.4 -40.6
................ ..................... --- ......_._.... .— — — --
3 Int 35 49 7 37.4 -40.6
4 Int 36 61 7 36.8 -40.0
5 Int 36 61 7 36.8 -40.0
6 Int 36 61 7 36.8 -40.0
7 Int 35 49 7 37.4 -40.6
......... .... .- __._ _. - -.. ------ ........ . _..._.__ --— --
8 Int 36 80 7 36.1 39.3
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code.