HomeMy WebLinkAboutProduct Approval • Zo r .t j. -:: .• ® ,a a ` r. e • �,5 Gulf Co��st SUPPLY & MANUFACTURING 5Vd 26 GA. _ T 5VCRIMP ROOF PANEL OVER • • Product Evaluation Report GULF COAST SUPPLY& MANUFACTURING, LLC 26 Ga. 5V Crimp Roof Panel over 15132"Plywood Florida Product Approval #11651.13 R2 Florida Building Code 2014 Per Rule 61 G20-3 Method: 1 —D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61 G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 •� �N1EL S� �' �,1 G E Ns� •.�, Engineer Evaluator: :*: No, 7551s Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 p•. STATE OF Q Validator: �OFSA,� 0RIDP •�`a��;` Locke Bowden, P.E. #49704 �'/S;ONAL ENG \'", 9450 Alysbury Place o6 l�o�X201 Montgomery, AL 36117 Contents: Evaluation Report Pages 1 — 5 FL#11651.13 R2•JUNE 15,2015 nom: ± Gullf "� ar„ SUPPLY & MANUFACTUftiNG 5Va • GA. 5VCRIMP ROOF PANEL OVER • • z Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Product Description: 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened roof panel with fasteners in the panel flat over minimum 15/32" plywood decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2014 Section 1507.4.3. Paint Finish Optional Yield Strength: 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2014, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 24" Coverage Rib Height: 3/9" Major Rib Panel Fastener: #9-15x1.5" with sealing washing in the flat of the panel or approved equal, '/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4 Substrate Description: Minimum "/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2014. Design Uplift Pressures: Table"A" Maxlnnm Tota!UpIIfDesigr Pres�re° 94`;25 ps ` ' 39 (3 psf , Fastener Pattern 12"-12" 9.5"-2"-9.5" Fa5e112tdtt�rR (}a' It7 xii 16" 0 CE � e � OC C. Design Pressure includes a Safety Factor=2.0. FL#11651.13 R2•JUNE 15,2015 �. G ulf SUPPLY & MANUFACTURING 5V3 26 GA. • • ROOF • . Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06 -Test for Uplift Resistance of Roof Assemblies • UL 1897-04-Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94/ 1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization #TST-5328) Report No. 117-0053T-05 & 117-0331T-08 2. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519)@ Kuhn Engineering, LLC (FBC Organization#ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. FL#11651.13 R2•JUNE 15,2015 xz;. KUHN ENGINEERING, Gulf �",,,, � SUPPLY & MANUFACTURING ` 'Cca� 5V 26 GA. SWRIMP ROOF PANEL OVER 15/32" PLYWOOD* ,.1 Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design.The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL#11651.13 R2•JUNE 15,2015 Gulfco�aft . . SUPPLY & MANUFACTURING 5V 26 ' . SVCRIIMP ROOFOVER • • ENGINEER LOAD TABLE:26 Ga. 5VCrimp Roof Panel over 15/32" Plywood Bu1,ldings having�a Roof Mean Helght s 20 0";:ftoofESlope 2"/1 Z" 1z'/12,20Gable Yor3WIp�Raaf,W nd�Spee�ds 120, 180nph, ExpasuGeC; RiskrCategory ll, EnclosedFBu[Itlirig based on Ffortda BIjding 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN. (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING r �� .. � • � OZONE 1 #9 15x1 5 Plywood 16 TYPE 1 15 TYPE 1; 16 TYPE 1 15 TYPE 1 15"TYPE 1 16"TYPE 1 16,TYPE 7 ZONE 2 #9-15x1.5" Plywood 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 777 ZONE 3 #915x1 S" Plyyilood 16"TYW"1 N 16'TYPE 1 16 TYPE'1 16 TYPE i 164NTYPE 1 16 TYPE 2 16 TYPEL'` 1.)PANEL DESCRIPTION:5V CRIMP, MIN. 26 GA., GRADE 80, 24"COVERAGE. 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER W/MIN. '/4" PENETRATION. 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:-94.25 PSF® 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN,-131.0 PSF @16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.)PLYWOOD DECKING: MIN.15/32" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014. 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2014 ZONE2 HIP ROOF ZONE 3 !?' Note:Dimension(a)is defined as 10%of the minimum width of the building or ,/,,ZONE ` ..........-.,a 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be less than either 4%of the minimum width of the building or 3 feet. <; \� I\ RIDGE TYPE 1 FASTENER PATTERN --- `� (1) #9-15 x 1-1/2" HWH w/Sealing Washer ZONE 1 ; 12" 12" -EAVE At Panel Lap— ZONE 2 GABLE ROOF ka+ - — _............._-..—........-- a R, TYPE 2 FASTENER PATTERN RIDGE (1) #9-15 x 1-1/2 HWH w/Sealing Washer i a 1µ---------------------- .. .... 1 a `L ZONE 1 I :.......................................... ......................_ \\��ZONE 3 HEAVE FL#11651.13 R2•JUNE 15,2015 4 Y'`� KUHN ENGINEERING, LLC 14670 ISLAND LAKES LANE, BOCA RATON,FL 33498-FL COA#3046'4 ='►ori&Building Code Online " rage: 1 or.z ^,,•q;:�j f.1F r i. BC15 atoms Log In User Registration Not 7b!cs Submit Surcharge Stats 8 Fads Pubt,eatians feC Staft' SCIS Site Maa" Links Search - hsines �� Y p C {� ��"�' Product A,pproVal Profen- jai USER:Pvbec User i F'' t Aoprovat MqN>Prodo[t-or."AooiitatwnS Ze..cr-h s AociicaV0M'0sk>�Appticatton Detail' , t FL s' FL5259•1129 }. APP. .. YP itcation Type' Revision y Code Version 2014 " Application Status Approved: *Approvedby DBPR,Appro�ais by.DBPR"shaii be reviewed and ratified• by the Pd and/or'the Commission if necessary:' Comments I` Archived..,'. Product Manufacturer POLYGLASS USA Address/Phone/Emall 150 Lyon Drive Fernleyi.NV 89'408.. (570)'384=1230.'"Ext 2'42 1 )akihs@polyglass.com a , Authorized Signature )ams Akins jakins@Pplyglass.conn i Technical Representative Steve Wadding. i Address/Phone/Emali. 150 Lyon Drive Fernley,.NV 98408 . (602)'363.7139 steJew@p,0Iyglass'.com Quality Assurance Representative _ lames Akins Address/Phone/Email 555 Qakridge.Road Humb'oidt Industrial'Pkwy Hazleton,PA.Il- (800) 8(800)894-4563 . jakins@polyglass,com. i Category Roofing. SubtategorY Undetlayments. j Compliance Method Evaluation Report from:a r1lorida RegisteredArchitect or a Licensed Florida Professional,Engineer Evaluation,Report-Hardcopy Received i Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report i Florida License PE-59.166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date -07/01/2017. Validated By. John W.Knezevich;PE Validation Checklist- Hardcopy Received Certificate of independence FLL,5259 R24 COi 20IS 01 COI'Nieminen.odf Referenced Standard andlYear(of Standard) standard Year ASTM D1970 2009 ASTM D226 2006 ASTM D6164 2005 ASTM 06222 20013 ASTM G154 2006 hr+..�•//..niriv fln,-irl�hnililinrr nrn/t4t:�Y1P HflT'1 rltl.actix�r,a,•al„-wC'tF:VX(ptivtDavbSaAaZn3C:.. 12/1812.015 r TRINITY ERD 5.6.3 Bond to Mechanically Attached Base Layer:, Polystick (all variations),.Pol,yflex SAP or SAP FR, Mule-Hide,SA-APP Cap, Sheet or,SA-APP Cap Sheet (FR) Dual.Pro or.. Tile Pro self-adhered to: :➢ ,ASTM D226;Type;I or 11 felt, EJastobase; Elastobase P"or Mule-Hide Nail Bise. . Elasto,flek 56 G or 56 G FR in hot asphalE to; r ASTM.D226,Type 1.or II felt; Efastobase>Elastobase P or Mule-Hide Nail Base: Polyflex G or G FR torch-appiied.to: :' 'EJastobase;EJastobase P o,rMule-Hide Nail Base. i For installations under mechanically attached prepared*roof coverings, base layer shall be attached per minimum codified requirements. For installation under foam-on the systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-i2),_Appendix A,Table 1, or as listed in Section 5:6.4 herein, or as tested lin accordance with FBC.Section 1504:3.1: i 5.6,4 Wind Resistance for Uriderlavment.Systems in Foam-On Tile Applications' "FRSA/TRI April 2012 (04-12) does not.. 1 address wind uplift.resistance of all Underlayment syste.ms'beneath foam-.pp the systems, where the underiayment I P " forms art of the load,-pith. The following, ind"u lift limitations'apply Ito ubderla merits stems that are not ig w. . P.� PPYI Y. Y addressed.in F.RSA/TRI April 2012 (04-12) and are used in foam-on tile.applications: Maximum Design Pressure is the s result of.testing"for wind load resistance based on allowable wind"loads, and reflects the ultimate."passing pressure i divided by2 (the 2 to 1 margin•of safety"per.FBC 1504,9 has already been applied).-Refer to FRSA/TRI April 2012(04- . I, 12),Appendix A,Table lA or F;BC 1609 for dzterminetion:of;design wind.loads. 5.6.4.1 Maximum'Design,Pressure -90 psf, " Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)PG100,,or ASTM D41 Base Ply: (Optional)Polystick MTS PLUS;self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick.TU Max,Polyflex SAP,Polyflex SAP,FR;Mule-Hide SA-APP Cap Sheet and Mule-Hide SA=APP.Cap Sheet,(FR),self-adhered. 5.6.4.2 Maximum Design Pressure=.-135 psf: Deck: Min.15/32-inch plywood-to meet project requirements to satisfactiog of AHJ. Primer' (Optional)PG100,or ASTM D41 Joints: Miri.4-inch wide strips of-Elastoflex SA-V overall plywood-joints. Base Ply: (Optional)Polystick'MTS PLUS,self-adhered Underlayment; Polystick TU P, Polysiick"TU Plus,Polystick TU Ma'C,Polyflex SAP,.Polyflex SAP FR,Mule-Hide SA=AP"P Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4:3 Maximum Design Pressure==315 psf, Deck: . Structural concrete to meet project requirements to satisfaction of A IJ: Primer: PG100,or ASTM D41 Base Ply: .(Optional)Polystick MTS PLUS,self-adhered ;. Underlayment: Polystick TU P, Polystick TU Plus, Polystick,TU Max,Tile Pro, PolyflexjSAP, Polyflex SAP FR,Mule-Hide"SA-APP Cap Sheet sand Mule=Hide SA-APP Cap Sheet(FR).self-adhered. ' 5.6.4:4 Maximum Design Pressure=-622.5 psf. 'Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: PG 100 or ASTM D41 Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G;torch-applied._ 5.6:4.5 Maximum Design Pressure -30.0 psf*. j Deck: Min.15%32-inch OSB to meet project requirements to satisfaction of AHJ. Base Sheet:' Elastobas-e or Mule-Hide"Nail Base(poly-film toplsurface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 64hch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2).equaly spaced staggered center rows. Base Ply: (Optional)Polystick MT5 PLUS,self-adhered Underlayment: Polystick TO P,Polystick TU Plus;Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. i i Exterior Research and,DeSign,LLC: Evaluation Report P12060.02.09-R20 Certlficote ofAuthorkation#9503 FL5259=R24 Revision 20:07/22/2015 Page 6 of 12 '. Florida Building Code Online rage 1 v3 }�1t'i1 Yrr;_�TC� BCl5 Home Log In User Registration Hot Topics Submit Surcharge Stats 6 Facts Publications FSC Stan SCIS Site Map Jnks 'Searcn, Du$lr��sm� S icUser Professig61w PductAproval I i Regulation m'm 13`7•Ja?FJ4197� ProtZuct Approval MQU>Product or.Application Search>Application list>Application petal! FL# FL5259 R24 I ME Application Type Revision Code Version 2014 Application Status Approved 'Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer POLYGLASS USA Address/,Rhone/Email 150 Lyon Drive Fernley, NV 89408 (570)384-1230 Ext 242 ' jakins@polyglass.com I !!l Authorized Signature 7arne5 Akins I jakins@polyglass.com Technical Representative Steve Wadding Address/Phone/Email 150 Lyon Drive Fernley,NV 98408 (602) 363-7139 stevew@polyglass.com i Quality Assurance Representative James Akins Add ress/Phone/Erriai1 555 Oakridge Road Humboldt Industrial Pkwy Hazleton,PA 18201 (800)894.4563 jakins@polyglass.com Category Roofing Subcategory Underlayments I l Compliance Method Evaluation Report from a Florida Registered Architect or Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received ' Fiorida�Engineer or Architect Name who developed Robert Nieminen the Evaluation Report I Florida,License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/01/2017 Validated By John W. Knezevich, PE Validation Checklist- Hardcopy Received Certificate of Independence FL5259 R24 COI 2015 Qi COI Nieminen pdf i Referenced Standard andiYear(of Standard) Standard Fear ASTM D1970 2009 ASTM D226 2006 ASTM D6164 2005 ASTM D6222 2008 ASTM G154 2006 ' I l,r+„n•/l,tn,ntii fl ,,•;r)ai1,E,;1rI;,�rr nrn/tir/rnr nnn rirl A1I)Y9naram—wCTFVX0wfiDovbSaAaZr33C... 12/18/21015 i Plorida Building Code Online rage % of;L i ASTM G155 71005 FM 4474 2004 FRSA/TRI April 2012 2012 TAS 103 1995 Equivalence of Product Standards Certified By I Sections from the Code i i Product Approval Method Method 1 Option D Date Submitted 07/22/2015 Date Validated 08/07/2015 Date Pending FBC Approval 08/15/2015 Date Approved 10/16/2015 Summary of Products FL# Model, Number of Description Name 5259.1 Polyglass!Roof Roofing underlayments Underlayfnents Limits!of Use Installation Instructions Approved for use in li No FL5259 R24 Il 2015 07 FINALER POLYGLASS UNDERLAYME TS FL5259- Approved for use outside HVH2::Yes 1124,odf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.)The design pressure in this Evaluation Reports application relates to onelparticular FL5259 R24-_AE 2015 07 FINAL IE_R_POLYGLASS UNDERLAYM NTS FL5259-. underlayment system (over concrete R24.pd( deck) for use under foamon the systems Created by Independent Third Party: Yes (where]the underlayment forms part of the load-path). Refer to ER Section 5.6.4 for other systems,other deck types and associated maximum design pressures. 2.) Refer to ER Section 5for other limits of use. I I flack Nezt n a I Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850.487.1824 The state of Florida is an AA/EEO employer.S:ooyrioht 2007.2013 State of Florida ::Privacy Statement::Accessibility Statement:: f Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records requ st,do not send electronic mail to this entity.Instead,contact the orrice by phone or by traditional mail.If you have any questions,please contact 850.487.1 95.'Pursuant to section;455.275(l),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,iF.S.must provide the Department with n email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If You donot wish to supply a personal address,pleasejprovide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Fu 09 yr [sucuritvmi fm,, I I i i httDs://www.floridabuildiiiL.orq/n'r/ni- ann dtl.asnx?nnrnm=wCTF.VXI x;Vtl /nvh.gnAA7.nlC' I R/')nt s ak EXTERIOR RESEARCH 8t DESIGN, LLC. Certificate of Autho,izotion#9503 ,... iTRINIWERD 353 CHRISTIAN STREET, UNIT 913 .. OXFOF D, CT 06018 PHONE: (2 3) 262-92415 FAX: (2 3) 262-9243 EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P120 0.02.09-112 150 Lyon Drive i FL5259-R2; Fernley, NV 98408 Date of Issuance 02/24/200� Revision 20 07/22/2015 SCOPE: This Evaluation Report is issued under Rlule 61G20-3 and the applicable rules and regulations governin the use of construction materials in the State of Florida, The documentation submitted has been reviewed by Robert N eminen P.E. for use of the product under the Florida Building Code and Florida Building Code,'Residential Volume, he products described herein have been evaluated for compliance with the 5" Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein, i CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named 1product(s) changes, th referenced Quality Assurance documentation changes,,or provisions of the Code that relate to thelproduct change. Acce- ante of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product ch%nges or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evalu tion Repo ri relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERiD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this erlitire Evaluation Report Shall be provided to�lthe user by the mcanufi cturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists!of pages I through 12. Prepared by: The facsimile seal appearing was authorized by R rt Nieminen, "t serve",an be rt V P.E.on 07/22/2015.'This does nal onically Robert J.M. Nieminen, P.E. signed document. Signed,sealed hardcopies ha been transmitted to the Product Approval Administrat)r and to the i Florida Registration No. 59166, Florida DCA ANE1983 named client CERTIFICATION OF INDEPENDENCE: 1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial int rest in any company marufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or coWolled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor wi,l] acquire, a financial interest in any company manufacturing or distributinf products fog which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor Will acquire, a financial interest in any other entity,involved in the approval r rocess of the product, 5. This is a building code evaluation. Neither;Trinity I ERD nor Robert Nieminen, P.E. are, in a!ny way, the Designer of Rxord for ani project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. j `4 A .t ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: .Roof Underlayments, as produced by Polyglass USA, Inc., hlave demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with tihe following Standards. Compliance is subject to the Installation.Requirement's and Limitations/Conditions of Use set forth herein. i 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 j 2004 II 1504.6 Accelerated Weathering ASTM G154 j 2006 1504.6 Accelerated Weathering ASTM G155 2005 1507.2.3,1507.3.3,1507.5.3,1507.7.3, Physical Properties ASTM D226 2006 1507.8.3,1507.9.3 1507.24,1507,2.9.2,1507.5.3,1507.7.3 Physical Properties ASTIv1 D1970 2009 1507.11.2 Physical Properties ASTIV D6164 2005 1507,11.2 Physical Properties ASTIVi D6222 2008 1507.3.3 Installation Practice FRSA/TRI April 2012 2012 1523.6.5.2.1 Physical Properties TAS 103 1995 I 3. REFERENCES: Entity Examination Reference Date FM Approvals(TST 1867) Wind Uplift 3004091 01/12 2000 PRI(TST 5878) Physical Properties PRIO1111 04J08 2002 ' PRI(TST 5878) Physical Properties PUSA-005-02-01 01/31 2002 PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23 2002 PRI(TST 5878) Physical Properties PUSA-013-02-02 12/23 2002 PRI(TST 5878) Physical Properties PUSA-013-02-03 12/23 2002 PRI(TST 5878) Physical Properties PUSA-018-02-01 07/14 2003 1 PRI(TST 5878) Physical Properties PUSA-028-02-01 07/132005 PRI(TST 5878) Physical Properties PUSA-033-02-01 01/12)2006 PRI(TST 5878) Physical Properties PUSA-035-02-01 09/29 2006 PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10 2007 PRI(TST 5878) Physical Properties PUSA-061-02-02 01/28 2008 PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22 2008 PRI(TST 5878) Physical Properties PUSA-083-02-01 04/14 2008 PRI(TST 5878) Physical Properties PUSA-088-02-01 07/29 2009 MTI(TST 2508) Physical Properties JX20H7A 04/01 2008 MTI(TST 25.08) Physical Properties RX14E8A 01/29 2009 ERD(TST 6049) Physical Properties 11752.09.99-1 i 02/08 2000 ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13 2001 i ERD(TST 6049) Wind Uplift 11776.06.02 I 01/16 2003 ERD(TST 6049) Physical Properties 02200.07.03 07/14 2003 ERD(TST 6049) Wind Uplift P1740,01.07 01/04 2007 ERD(TST 6049) Physical Properties P5110,04.07-1 04/11 2007 ERD(TST 6049) Wind Uplift P9260.03.0,8 03/21 2008 ERD(TST 6049) Physical Properties P13450A8.09 08/13 2009 ERD(TST 6049) Wind Uplift P30540.11.09-Rh 11/30 2009 ERD(TST 6049) Physical Properties P11030.11.09-11 11/30 2009 ERD(TST 6049) Wind Uplift P11030.11.09-21 11/30 009 ERD(TST 6049) Physical Properties P11030.11.09-31 11/30 2009 ERD(TST 6049) Physical Properties P33360.0610 06/25 2010 ERD(TST 6049) Physical Properties P33370.03.11 03/02 2011 Exterior Research and Design,LLC. Evaluation Report 12060.02.09-R20 Certificate of Authorization#9503 FL5259-R24 Revision 20:07/22/2blS Page 2 of 12 i I I TRIM TY ERD Entity Examination Reference Date ERD(TST 6049) Physical Properties P33370.04.11 04/26/ 011 ERD(TST 6049) Physical Properties P37300.10.11 10/19/ 011 ERD(TST 6049) Physical Properties P40390.08.12-1. 08/06/ 012 ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/ 012 ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/ 012 ERD(TST 6049) Wind Uplift P39680.03.13 03/04/ 013 j ERD(TST 6049) Physical Properties P45370.04.13 04/26/ 013 ERD(TST 6049) Wind Uplift P1738.02.07-R21 04/29/ 013 ERD(TST 6049) Wind Uplift 11757.04.01-1-f{1 04/30/ 013 j ERD(TST 6049) Wind Uplift P41630.08.13 08/06/ 013 ERD(TST 60 49) Wind Uplift P11751.05.03-R1 11/26/ 013 ERD(TST 6049) Wind Uplift P11781.11.03-131 11/26/2013 ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014 ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-2 09/08/2014 ERD(TST 6049) Physical Properties 6020,09.14-3 09/08J2014 ERD(TST 6049) Physical Properties 6020.09.14-4 09/08 2014 ERD(TST 6049) Physical Properties 6020.09.14-5 09/0812014 I ERD(TST 6049) Physical Properties 6020.09.14.6 09/08j 2014 ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD(TST 6049) Physical Properties P44360.10.14 10/07j 2014 ERD(TST 6049) Physical Properties P43290.10.14 10/17,2014 ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24,201S ERD(TST 6049) Physical Properties P40390.04.15 04/03,201S ERD(TST 6049) Wind Uplift PLYG-SC8905.15 07/22,2015 ICC ES(EVL 2396) IBC Compliance ESR-1697 11/01,2014 Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/22 2015 Polyglass USA Manufacturing Affidavit Products Current 02/18 f2009 Polyglass USA P/L Affidavit Mule-Hide Crolis Ltg 03/01f2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18 f2011 UL,LLC.(QUA9625) Quality Control Service Confirmation,R14571 Exp.03/08/2015 UL,LLC.(QUA9625) Quality Control Service Confirmation,MTS PLUS Exp.07/01/2017 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlavments: 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. I 4.1.2 Elastobase P is a polyester-reirrforced,SBS modified bitumen base sheet. 4.2 Self-Adhering Underlavments:. 4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfacled with polyolefinic film surface; meets ASTM D1970 and TAS 103, 4.2.2 Polystick MTS PLUS is ,a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with poly-film surface; meets TAS 103. i 4.2.3 Polystick IR-Xe his a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, withian aggregate surface; meets ASTM D1970. I 4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing!membrane, glass fiber re nforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4,2.5 Polystick TU P is a nominal 130.-mil thick rubberized asphalt waterproofing membrane,glass-fiber/poly ster reinforced, with a granularsurface; meets,ASTM D1970 and TAS 103. 4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface; meets ASTM D1970 and TAS 103. j Exterior Research and Design,LLC. Evaluation Repor P12060.02.09-R20 Certificate of Authorization#9503 FL5259-R24 Revis on 20:07/22/2015 Page 31of 12 I i i i TRN TY ERD 5.5.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ✓ 3M` 2-Component Roof Tile Adhesive AH-160 (FL6332): Polystick TU F, Polystick TU Plus, Poly tick TU Max, Elastoflex S6 G, Polyflex G„ Polyflex SAP, Polyflex SA Cap FR, Mule-Hide S!A-APP Cap Sheet or Mule Hide SA-APP Cap Sheet(FR)or Tile Pro. ✓ 3M'" Foam Roof Tile Adhesive RTA-1 (FL6276): Polystick TU P, Polystick T U Plus, Polystick TU Max, Elastoflex 56 G, Polyflex G, Polyflex SAP; Polyflex SA,Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet (FR) or Tile Pro ✓ Dow TileBond(FL717): Polystick TU P, Polystick TU Plus, Polyflex SAP or Tille Pro ✓ Convenience Products' Touch 'n Seal StormBond Roof Tile Adhesive (FL�1.4506): Polystick TU Plus Polystick TU Max 5.6 Allowable Substrates: I 5.6.1 Direct-Bond to Deck: Polystick(all variations), Dual Pro,Tile Pro, Polyflex SAP or SAP FR, Mule-HidelSA-APP Cap Sheet or SA-APP Cap Sheet (FR)self-adhered to: New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existin plywood; New or existing; unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; AST D41 primed I Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIPS stem" Panells (designed and installed to meet wind loads for project). Note: Polygloss-does not require priming of new or existing plywood or OSB sheathing. New or existif g plywood qr OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex S6 G or S6 G FR in hot asphalt to: > ASTM D41 primed structural concrete. Polyflex G or G FR torch-applied to: > ASTM D41 primed structural concrete, 5.6.2 Bond-to-Insulation: Polystick (all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self-adhered to: `r ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Dedk DuraGuard; Dens Deck Prime; or SECUROCK Gypsum-Fiber Roof Board. i Elastoflex S6 G or S6 G FR in hot asphalt to: > Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. Polyflex G or G FR torch-applied to: > ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. For installation• under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval, For installations under foam-on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. I j i i Exterior Research and Design,LLC. Evaluation Report 1120150.02.0911120 Certificate o/Authorization#9503 FL5259IR24 Revisi n 20:07/22/2015 Page 5 df 12 I .'J TIMI iTY ER, 5.6.4.6 Maximum Design Pressure=:-37.5 psf*. Deck: Min. 15/32-inch,plywood to meet project requirements to satisfactioh of AHJ. Base Sheet! Elastobase or Mule-Nide Nail Base(poly-film top surface) ' Fasteners: 11 ga.x 1.25-in6h long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c,at the 3-inch wide side laps and 6-inch o.c.at two(2)equ Ily spaced staggered center rws. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP, Po flex SAP FR, Mule Hide SA-A P Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. I I 5.6.4.7 Maximum Design Pressure=-37.5 psf*. Deck: Min.19/32-inch;piywood to meet project requirements to satisfaction of AHJ. Base Sheet: One(1)or two(2)layers ASTM 0226,Type II felt Fasteners: 11 ga,x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. i 5.6.4.8 Maximum Design Pressure=-45 psf*, Deck: Min. 19/32-inch;plywood to meet project requirements to satisfactiop of AHJ. Base Sheet: One(1)layer ASTM D226,Type ll felt Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diamete tin caps Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c,at two(2)equalily spaced staggered center r ws. Base Ply: (Optional;for use with self-adhering underiayment only)Polystick M7S PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-A P Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex S6 G,applied in full mopping of hot a phalt. 5.6.4.9 Maximum Design Pressure=-45 psf*. Deck: Min. 19/32-inch'plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Two(2)layers ASTM D226,Type it felt Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps] Spacing: 9-inch o.c.at the.,2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center r,ws. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick M'S PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP,Pol�flex SAP FR,Mule-Hide SA-A'P Cap Sheet and Mule-Hide SA-APP Cap Sheet iFR),self-adhered or Elastoflex S6 G,apQlied in full mopping of hot a phalt. 5.6.4.10 Maximum Design Pressure=-45 psf, Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch- pplied cap) Fasteners: Simplex MAXX Cop Fasteners Spacing: 9-inch o.c.at the2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center lows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch -applied. 5.6.4.11 Maximum Design Pressure=,52.5 gsf. Deck: Min.15/32-inch plywood to meet project requirements to satisfactio?of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch- pplied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at thei2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center ows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. j 5.6.4.12 Maximum Design Pressure==52.5 psf. E Deck: Min. 15/32-inch plywood to meet project requirements to satisfactia I of AHJ. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) [ Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the'3-inch wide side laps and 6-inch o.c.at four(4)equallly spaced staggered center r ws. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR,Mule-Hide SA-A P Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. i 4 Exterior Research and Design,LLC. Evaluation Report P12060.02.09iR20 Certificate of Authorization 119503 FL5259L,R24 Revisisn 20:07/22/2015 Page 7 of 12 I t c - 1 1 1 TRI IITY ERD i 5.6,4.13 Maximum Design Pressure==52.5 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap!r poly-film surface for torch applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the'3-inch wide side laps and 6-inch o.c.at four(4)egjally spaced staggered center rows, Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.14 Maximum Design Pressure=,60 psf. Deck; Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch1applied ca pJ Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank(oofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the14-inch wide side laps and 8-inch o.c.at three(3)eglualiy spaced staggered cente rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,Torch-applied. 5.6.4.15 Maximum Design Pressure=;60 psf. Deck; Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ. I Base Sheet: Elastobase(sanded top surface=_for hot-asphalt or torch-applied cap or poly-film surface for torch lapplied cap) Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates i Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)eually spaced staggered cent r rows. i Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.16 Maximum Design Pressure=-90 psf. i I Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap pr poly-film surface for torch pplied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c,at the•2-inch wide side laps and 6-inch o.c.a;two(2)equally spaced staggered center Tows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,t!orch-applied. I 5.6.4.17 Maximum Design Pressure= 490 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ, Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-'pplied cap) Fasteners: OMG 912 Standard Roo€grip or OMG 914 Heavy Duty with OMG 3"Round Metal Plates or OMG I lat Bottom Meta( Plates Spacing: 6-inch o.c.at the14-inch wide side laps and 6-inch o,c.at three(3)eq ally spaced staggered centei rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.18 Maximum Design Pressure=490 psf, Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast 912 DP or Trufast 914 HC)with Trufast 3"Metal Insulation Plaites 4 Spacing: 6-inch o.c.at the -inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered centei rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.19 Maximum Design Pressure=;97,5 Psf. Deck: 'Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) I Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofinlg nails at 1-S/8-inch diametr tin caps Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered centerrlows. Base Ply: (Optional)Polystick MTS PLUS,self-adhered i Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-AI P Cap Sheet and Mule-Hide SA-ARP Cap Sheet(FR),self-adhered. 5.6.4.20 Maximum Design Pressure==105 psf. Deck; Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap qr poly-film surface for torch- pplied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the:2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. Exterior Research and Design,LLC. Evaluation Report P12060.02.09LR20 Certificate of Authorization#9503 FL5259}R24 Revisi�n 20:07/22/2015 Page 8 of 12 TRI 1TY 'ER� i 5.6.4.21 Maximum Design Pressure=-112.5 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AH1. I Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inchx 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameteritin caps Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equal y spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin-caps I j Base Ply: Polystick MTS PLUS,self-adhered I Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.22 Maximum Design Pressure=-120 psf. Deck; Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. � Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG 012 Standard Roofgrip or OMG 014 Heavy Duty with CMG 3" Rqund Metal Plates or OMG FI It Bottom Meal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(S)equally spaced staggered center ro s. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,tofch-applied. 5.6.4.23 Maximum Design Pressure=-120 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHL Base Sheet: Elastobase(sanded top surface!) Fasteners: Trufast 012 DP or'Trufast 014 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the",4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. i 5.6.4.24 All other direct-deck, adhered Polyglass Underlayment systems beneath Foam-on tile systems car dly a Maximum Design Pressure of-45 psf. 5.6.4.25 For mechanically attached base sheet in a 2-ply system, the maximum desigrj pressure for the selectedjassembly shall meet or exceed the Zone 1 design pressure determined in accordance with FRSA/TRI April 2012 (04-12),Appendix!A, Table 1A or FBC 1609. Zones,2 and 3 shall employ an attachment density d isigned by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS�117, FM LPDS 1 29 and ANSI/SPRI WD1. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDA 1-29 for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobase or Elastobase P shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe shall not be left exposed for longer than 90-days after installation. Polystick MTS, MTS PLUS, TUiP, TU Plus, TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 1�0- days after installation. Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive set tile, in which case the maximum jexposure is 30 days. Elastoflex S6 G or S6 G FR or Polyflex G or G FR does not have an exposure limitation, unless thel prepared roof covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. i i I i i i I i I Exterior Research and Design,LLC. Evaluation ReportIP12060.02.09111120 Certificate of Authorization N9503 FL5259-R24 Revision 20:07/22/2015 Page 9of12 i TRINITY ER, D 6. INSTALLATION: j 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polylass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics note below. ` 6.2 Re-fasten any loose deck'ingi=panels, and check for protruding nail heads. S eep the substrate thoroughly to remove any dust and debris prior to application; and prime the substrate(if applicable). 6`3 Elastobase Elastobase P or Mule-Hide Nail Base: 6.3.1 Shall be installed in compliance with the codified requirements for ASTM D 26,Type 11 underlayment in FBC Sectio ns 1507 for the type of prepared roof covering to be installed, I 6.3.2 Non-Tile Applications: j Reference is made to the current edition of the NRCA Steep-slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a Iyer of Polystick, Polyflex',SAP or SAP FR, Mule-Hide SA-APP Cap Sheet;or SA-APP Cap Sheet(FR), Dual Pro or Tile Pro,;Self-adhered, Elastoflex S6 G or S6 G FR in hot asphalt or Polyflex G or G FR,torch applied. 6.3.3 Tile Applications: Reference is made to FRSA/TRI April 2012(04-12) Installation Manual and TJible 1 herein,using the instructions nolled above as a guideline. 6.4 Polystick MTS MTS PLUS IR Xe,TU P,TU Pius.TU Max Polyfie>c SAP or SAP FR Mule-Hide SA-APP Cap Sheet or SA- APP Cap Sheet(FR),Dual Pro or Tile Pro: I 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBG Sections 15107 for the type of,prepared rooficovering to be installed. I 6.4.2 Direct-to-Deck with Mechanicaily Fasten !d Roof Covers: All self-adhering materials,with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule-H'sde SA-APP Gap Sheet or SA-APP Cap Sheet (FR) should be back-nailed in selvage edge seam�in accordance with Polyglass/ Mule-Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter metal disk or Simplex-type metal cap nail. at a minimum rate of 12" o.c. Polystick TU Plus should be back-nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back-nailed All seal-lap seams (selvage laps) must. be firmly rolled with a minimum 28 lb, hand a k; C roller to ensure full contact and adhesion, For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern c - (the sheet will overlap the fabric). k View of Ovelap Scam of Dual Pro end Tile Pro All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between tie application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed vaile',ys, or exposed roof to wall details Exterior Research and Design,LLC. i Evaluation Report IP12060.02.09''R20 Certificate of Authorizotion#9503 IFL5259'�R24 Revisibn 20:02/22/015 Page 10 of 12 I z I .,h �~ TiI�IIT'� EWD Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement to the area in need of repair, followed(by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repa r area, Patch laps, if needed, shall lie installed in a water shedding manner, All Polystick membranes shall be installed to ensure full contact with ap roved substrates. Polyglass requires is minimum of 40-Ib weighted-(,oiler or, on steep slopes, use of a stiff broom ith approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches,las(min. 28 Ib roller)or small areas of tl e roof that are not accessible to a large roller or broom. 6.4.3 Tile Applications(not ollowed�for Polystick fR-Xe Reference is made to FRSA/TRI April 2012(04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. l For mechanically fastened tile roofing over 2-ply system, consisting of base s eet and self-adhering top sheet(s), balie sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Tal 1, For adhesive-set tile applications, refer to Section 5.6.4 herein. j For nail-on tile systems over Polystick MTS, battens are required for loading/istaging of the tile. For nail-on tile systems over Polystick MTS PLUS: > Battens are required for loading/staging of lugged the regardless of slope,i > Battens are required for loading/staging of flat tile at slopes in excess of 51:12. 6.4.4 Two(2)Ply Underlayment Systems: Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, T'IIePro or 8olyflex SAP is allowable for use under mechanically attached prepared roof systems. Limns of use are those associated with thle top-layer material. This is not:a requirement,but is allowable if a 2-ply underlayment system is desired. Polystick MTS PLUS followed�by Polystick.TU P, TU Plus, TU Max, TilePro or Polyflex SAP is allowable for use under foam-on tile systems. Limits of use are those associated with the top-layer material, This is not a requirement, but is allowable if a 2-ply underlayment system is desired. 665 Elastoflex S6 G or S6 G FR: 6.5.1 Elastoflex S6 G or S6 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications, reference is made to FRSA/TRI April 2012(04-12) In,stallation Manual and Table 1 herein. 6.5.2 Elastoflex S6 G or S6 G FR shall be fully asphalt-applied to the substrates noted in Section 5.6. SideL laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. 'Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. i 6_6 Polyflex G or G FR: I 6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications, reference is made FRSs/TRI April 2012 (04-12) Installation anual and Table 1 herein. 6.6.2 Polyflex G or G FR shall be fully torch-applied to the substrates noted in Section 5.6. Side laps shall be minimum 3,L inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end;laps shall b� fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 667 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Polyglass published requirements for tile staging, 1 6.7.2 Battens and/or Counter-battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail- boards,to prevent the sliding and/or damage to the underlayment during the I@ding process. 6.7.3 For nail-on the systems over Pblystick MTS., battens are required for loading/staging of the tile. I I Exterior Research and Design,LLC. Evaluation Report P];2060.02.09-1120 certificate of Authorization#9503 FL5259-R24 Revision.20:07/22/2015 Page 11 of 12 e ! i e ` -,i TRIN11Y ESD 6,7.4 For nail-on the systems over Polystick MTS PLUS: > Battens are required for loading/staging of lugged the regardless of slope. > Battens are required for loading/sta.ging of flat tile at slopes in excess o 5:12. 6.7.5 The minimum cure time after installation of self-adhering membranes and iefore loading of roofing tiles is forty-eight (48)hours. i 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: !' Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements, j 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625;(314)578-3406; k.chancellor@us.uLcom ! END OF EVALUATION REPORT- I 1 i I! i i i i 1 I I i i i I ' 1 I 1 i I I i 1 ' i i Exterior Research and Design,LLC Evaluation Report P112060.02.D9-R20 Certificate of Authorization#9503 FL5259-R 1 Revision,20:07/22/2015 Page 12 of 12 i