HomeMy WebLinkAboutProduct Approval RECEIVED FEB 16 2016 MIMI®1DiADE s PEP:dIITTIWG MIAMI-DADS COUNTY St. Lucie County, FL PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) xmvw.miamldade.Prov/buiIdIne Sun-Dome by Daylighting Technologies,Inc. 3612 Reese Avenue West Palm Beach,FL 33404 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements ofthe applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Sun-Dome Skylight APPROVAL DOCUMENT: Drawing No. 1,titled"Sun-Dome/Tubular Skylight",prepared by Daylighting Technologies Inc,dated 11/07/01,with last revision dated 12/05/11,sheet 1 of 1,signed and sealed by Terrence Earl Lunn,P.E.,on 12/05/11 bearing the Miami-Dade County Product Control revision stamp with the Notice of Acceptance number and the expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and the following statement: "Miami-Dade County Product Control Approved or MDCPCA",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#11-0817.13,and consists of this page 1,evidence submitted pages E-1 &E-2,as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A.Makar,P.E.,M.S. MIAMFDADE NOA No. 11-1212.04 • ��' Expiration Date: 12/15/2016 o �14/Zo!Z Approval Date: 01/19/2012 Page 1 San-Dome by DDgAightins Technologies,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#07-0917.03 A. DRAWINGS 1. Drawings prepared by Daylighting Technologies, Inc., titled "Sun-Domeffubular ,Skylight", Drawing No.], Sheet 1 of 1, dated 11/07/01, with last revision dated 10122107, signed and sealed by Terrence E. Lunn, P.E. B. TESTS 1. Test reports on 1)Air Infiltration Test,per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test,per FBC, TAS 202-94 4)Large Missile Impact Test per FBC, TAS 201-94 5)Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of tubular dome,prepared by Hurricane Test Laboratory, LLC, Test Report No. 0454-0903-06, dated 01/16107, signed and sealed by Viny J. Abraham, P.E. C. CALCULATIONS 1. Anchor calculations letter issued T.E. Lunn, RE.,LLC, dated 10130107, signed and sealed by Terrence E. Lunn, P.E. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Offlce(BCCO). E. MATERIAL CERTIFICATION 1. None. F. STATEMENTS 1. Test Compliance letter issued by.Hurricane Test Laboratory, LLC, issued on 01116107, signed and sealed by Vinu J. Abraham, P E. 2. Code compliance letter issued by T.E. Lunn, P.E., LLC, dated 10130107, signed and sealed by Terrence E. Lunn, P.E. 3. No financial interest letter issued by T.E. Lunn, P.E., LLC, dated 10122107, signed and sealed by Terrence E. Lunn, P.E. 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#11-0817.13 A. DRAWINGS 1. None. elmy A.Makar,P.E.,M.S. PERA,Product Control Unit Supervisor NOA No.11-1212.04 Expiration Date: 12/15/2016 Approval Date:01/19/2012 E-1 Sun-Dome by Daylighting Technologies,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE I. Miami-Dade County Building and Neighborhood Compliance Department(BNC). E. MATERIAL CERTIFICATION 1. None. F. STATEMENTS L Code compliance letter issued by T.E. Lunn, P.E., LLC, dated 07/29/11, signed and sealed by Terrence E. Lunn, P.E. 2. Letter issued by TE. Lunn, P.E., LLC, dated 07/29/11, signed and sealed by Terrence E. Lunn, P.E., certify that he is still in the engineering business. 3. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 1, titled "Sun-Dome/Tubular Skylight", prepared by Daylighting Technologies Inc, dated 11/07/01, with last revision dated 12/05/11, sheet 1 of 1, signed and sealed by Terrence Earl Lunn, P.E.,on 12/05/11. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami Dade County Department of Permitting, Environment, and Regulatory Affairs (PERA). E. MATERIAL CERTIFICATION 1. Addendum letter prepared by HTL, dated 12/05/11, signed and sealed by Finu J. Abraham, AE., stating the correct weather seal. e my A.IYlakar,P.E:,M.S. PERA,Product Control Unit Supervisor NOA No.11-1212.04 Expiration Date: 12115/2016 Approval Date:01/19/2012 E-2 PILE WEATHER SEAL POLYCARBONATE DOME (l/8" NOMINAL THK (SCHLFI EL WEATHER 5EAL VAC. FORMED) GE LEXAN XL-1 O DADE CO. APPROVED RUBBER/5.5. WASHER LZL DARK FOAM TUBE SEAL 4 - RUBBER O-RINGS DOME FASTENER-#8 x I"STAINLESS STEEL SCREW AT 9"O.C. ROOFING DETAILS SHALL COMPLYWITH CHAPTER15 OF THE FLORIDA BUILDING t ADJUSTABLE TOP TUBE CODE. 4�� MIN. CLEARANCE FROM DOME LIP TO ROOF SURFACE FOR SHINGLE 'BUR W/O INSULATION. FOR INSULATION AND TILE ROOF: ADD THE TILE HEIGHT AND THE MIN. 4" 0.040 ALUMINUM ROOF FLASHING INSULATION THICKNE55 TO 4". (ASHLEY 3105 A5TM 8209) ROOFING SYSTEM ROOF SHEATHING RING SHANK FLASHING NAIL 7/1 G"O HD x 1-1/2" LG. DESIGN PRESSURE RATING: +/- 100 PSF SUN-DOME CONNECTION DETAILS APPROVED FOR USE IN PRODUCTREVIS13D AND OUT5IDE HVHZ. as complying with the Florida Building Code Acceptance Nott—Z12.o¢ ° ° o ° o Expiration nate �p 16 Mi D ct ontrol A ° B RING SHANK NAIL I I GA. x 7/'1 G" HD x 1-1/2" L ° ° ° ° • ° 1-1/2"TYP. B ROOF FLASHING DIMENSIONS SUN-DOME DIMENSIONS ROOF FLANGE DIMENSIONS DOME FOR BCCO U5E MODEL Y DIA. X RISE A B C FASTENERS 21" 22" 9.5 2 I.5" 29.0" 5 5PACE5 +/-G" 8 13" 14" G.75" 13.5" 23.5" 4 SPACE5 +/-5" 5 I O° I I` G.0" 10.5 20.0" I 3 SPACE5 +/-5` 4 ENGINEERING ,�t,1 �� REV15ION: 10.22.07 ADDED REG NO.AND NAILING 2213 22nd LANE �`���e1G•.E iii 12-5-1 1 TO SCHLEGEL 5EWAL PALM BEACH GARDENS. ,�� Q ty E •.�GI FWRIDA 32418 ���wQ:• F ••2 PRODUCT 561 62564M • .' SUN-DOME / TUBULAR SKYLIGHT H IILRe .#26119 ; 1�9 SCALE: 12"= I'-0" IJUMINUM CURB/PC DOME DATE: 10/22/07 CAD DWG FILE: ��� 2$ U'Iltt OF ZDAYLIGHTING TECHNOLOGIES DRAWING DRAWN BY: TEL :;A%%� P.� RIVIERA BEACH, FL 33404 I OF I CHECKED BY: TEL �i t� O R 1 p.• 0 N F+ -