HomeMy WebLinkAboutProduct Approval 'i t � SEB 16°�p16 RE�E1� EVALUATION REPORT OF UNION CORRUGATING COMPANY `29 GA.MASTERRIB PANEL' OVER WOOD SUPPORT AND DECK FLORIDA PRODUCT APPROVAL FL 7271.9-R2 ROOFING C METAL ROOFING Prepared For: Union Corrugating Company P. O. Box 229 Fayetteville,NC 28302 Telephone: (910)483-0479 Fax: (910)483-8897 Prepared By: Bala Sockalingam,Ph.D.,P.E. Florida Professional Engineer#62240 1216 N Lansing Ave.,Suite C Tulsa, OK 74106 Telephone: (918)492-5992 FAX: (866)366-1543 This report consists of Evaluation Report(3 Pages including cover) Installation Details (1 Page) ��}►� 5®CKAL�N®®�®o .•.•.......a ENS No 82240 • *. w G :gyp; :jr Report No. C1805-15 STATE OF e•ww Date: 12.7.11 �e�'O,t` •:�.�O R`�''•�®��'� FL 7271.9-R2 C1805-17 12.7.11 Page 2 of 3 Manufacturer: Union Corrugating Company Product Name: MasterRib Panel Panel Description: 36"wide coverage with 3/4"high ribs at 9" o.c. Materials: Minimum 29 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Support Description: Nom. 1" x 4" (min) lumber(Must be designed by others) Support Attachment: (1)#9 x 3" long wood screw into rafters spaced at max 24" o.c. New Underlayment: Minimum underlayment as per FBC 2010 Section 1507.4.5. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of#30 felt.For reroofing (Optional) construction only. Deck Description: Min 15/32" thick plywood or 7/16" thick OSB deck for new and existing constructions. Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c. at plywood field and edges Slope: 1/2:12 or greater in accordance with FBC 2010 Section 1507.4.2 Design Uplift Pressure: 71 psf for Fastener Pattern 1 (Factor of Safety=2) 114 psf for Fastener Pattern 2 Panel Attachment: #9-15 wood screw with washer. Fastener shall be of sufficient length to penetrate through the support and deck a minimum of 3/8". Pattern 1 @ 9" o.c. across panel width Pattern 2 @ 5.5"-3.5"-5.5" o.c. across panel width Sidelap Attachment: '/a"-14 x 7/8" long SDS @ 24" o.c. Recommended for roof slope less (Optional) than 3:12. Test Standards: Panel assembly tested in accordance with ASTM E1592-01 `Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference' and FM 4470 Section 5.5 `Resistance to Foot Traffic'. Code Compliance: The product described herein has demonstrated compliance with FBC 2010 Section 1507.4 FL 7271.9-R2 C1805-17 12.7.11 Page 3 of 3 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2010 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This product is not approved for use in the High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2010 Section 1505 and current approved roofmg materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: ASTM E1592 Test Report ENCON Technology Inc. C1811-1,Reporting Date 11/30/11 FM 4470 Test Report ENCON Technology Inc C1583-2,Reporting Date 7/24/08 SIDELAP FASTENER PANEL FASTENER EXISTING SHINGLES NOM. 1" X 4" FOR ROOF SLOPE #9-15 @ 9" O.C. (OPTIONAL) LUMBER LESS THAN 3:12 — — -- — — — — --- EXISTING UNDERLAYMENT OSB 7/16" THICK (MIN.) OR (OPTIONAL) PLYWOOD 15/32" THICK (MIN.) #9 X 3" LONG WOOD SCREW FASTENER PATTERN 1 MIN. 2X— WOOD RAFTER/JOIST/ TRUSS AT MAX. 24" O.C. SIDELAP FASTENER PANEL FASTENER EXISTING SHINGLES NOM. 1" X 4" FOR ROOF SLOPE #9-15 0 3.5"-5.5" O.C. (OPTIONAL) LUMBER LESS THAN 3:12 e" o --- ----- -------- ----- --------- ----- --- -----=11----- -- ------ ----- -- A EXISTING UNDERLAYMENTOSB 7/16" THICK (MIN.) OR (OPTIONAL) 7 PLYWOOD 15/32" THICK (MIN.) #9 X 3" LONG m WOOD SCREW o� FASTENER PATTERN Z MIN. 2X— WOOD RAFTER/JOIST/ TRUSS AT MAX. 24" O.C. GENERAL NOTES, 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC), ALLOWABLE UPLIFT PRESSURE 2. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 3 3. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS FASTENER PRESSURE PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS PATTERN (PSF) ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 4. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA 1 71.0 BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM c� $ REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 2 114,0 5. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS � —�ll REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS, x C�I 5 F J, �0_ 3/4" f� 36" WE: 11-30-2011 MASTERRIB PANEL PROFILE y of y 29 Gauge, Minimum Yield = 80 KSI