Loading...
HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE, INC. 806 Delaware Ave.Ft. Pierce,Florida 34950 Phone: (772)460-7751,Fax: (772)460-4244 R E C E I'.`-D FEB 16 2016 Email Address: cookmenard@yahoo.com January 29, 2016 St. Lucie County Building Department Attn: Roof Permit Plan Review ��� 2300 Virginia Avenue E COPV Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structures located at 3104 Dupan Terrace, :St Lucie County, Florida Manufacturer: Union Corrugating Company Profiles: 29 GA. Masterrib Panel, FL#7271.9 Code: FBC 2014; Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 30' Maximum Pitch:. 4"/12" Required Design Pressure: Zone1:-38.2 Zone 2: -53.9 Zone3:-101.4 Maximum Uplift Pressure: Fastener spacing:Zone 1 &2-71 @ 9 o.c., Zone 3 -114 @ 5.5"-3.5"-5.5" o. c Fasteners: #9-15 Wood screw with washer @ 9" o.c.,Zone 1 & 2, @ Zone 3,5.5"-3.5" -5.5" o.c. across panel width. Fastener shall be of sufficient length to penetrate through the support and deck a minimum of 3/8 . Underlayment: Existing one layer of asphalt shingles over one layer of 30#felt. For reroofing construction only. Roof Decking: Existing 15/32" plywood sheathing The above approved, as per Florida Building Code Compliance acceptances, 2010 Florida Building Code, and the Manufacturer's recommendations. Respectfully Submitted,.:-- y .5 1 1 FI 1 - Pe6rB Cook Cook'&-Wna'rd,Aecture, Inc. State of Florida Registration No.AA0003494,NCARB Certification No.31789