HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE, INC.
806 Delaware Ave.Ft.Pierce,Florida 34950
Phone: (772)460-7751,Fax: (772)460-4244
R E C E I VE--D F EB 16 2Mai1 Address: cookmenard@yahoo.com
January 29, 2016
St. Lucie County Building Department FILE Copy
Attn: Roof Permit Plan Review
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structures located at
3120 Dupan Terrace: St Lucie County, Florida
Manufacturer: Union Corrugating Company
Profiles: 29 GA. Masterrib Panel, FL#7271.9
Code: FBC 2014;Section R 905.10
Wind Speed: 160 MPH; Ultimate Design Wind Speeds
Exposure: B
Mean Roof Height: 30' Maximum
Pitch: 4"/12"
Required Design Pressure: Zone1: -38.2 Zone 2: -53.9 Zone3:-101.4
Maximum Uplift Pressure: Fastener spacing:Zone 1 &2-71 @ 9 o.c., Zone 3 -114 @ 5.5"-3.5"-5.5" o. c
Fasteners: #9-15 Wood screw with washer @ 9" o.c.,Zone 1 &2, @ Zone 3, 5.5"-3.5" -5.5"
o.c. across panel width. Fastener shall be of sufficient length to penetrate
through the support and deck a minimum of 3/8
Underlayment: Existing one layer of asphalt shingles over one layer of 30#felt. For
reroofing construction only.
Roof Decking: Existing 15/32" plywood sheathing
The above approved,as per Florida Building Code Compliance acceptances, 2010 Florida Building Code, and
the Manufacturer's recommendations.
Respectfully Submitted,
Peter B. Cook
...Cooke&.Menard.Arehitecture, Inc.
` State of Florida Registration No.AA0003494,NCARB Certification No.31789