HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 3
`uda Ge'Fdltmentd BCIS Home ! Log In j User Registration i Hot Topics j Submit Surcharge ? Stats&Facts I Publications I FBC Staff j BCIS Site Map Links Search
Busines� s
�r%SSi0f1�� 1 3 a. Product Approval
���JJJ 1 µL`�$ USER:Public User
Regulation
Product Approval Menu>Product or Aoolication Search>Application List>Application Detail
u rm
FL# FL5684-R7
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Clopay Building Products Company
Address/Phone/Email 8585 Duke Blvd.
Mason,OH 45040
(513)770-6062
mwesterPield@clopay.com
Authorized Signature Scott Hamilton
shamilton@clopay.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
W Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Scott Hamitlon
the Evaluation Report
Florida License PE-63286
Quality Assurance Entity Intertek Testing Services NA Inc.-ETL/Warnock Hersey
Quality Assurance Contract Expiration Date 12/31/2038
Validated By Gary Pfuehler
W, Validation Checklist-Hardcopy Received
Certificate of Independence FL5684 R7 COI Certification of Independence of Evaluation Entity-
Gary Pfuehler.pdf
FL5684 R7 COI Statement on Independence of Evaluation Entity-
ScottHamilton.pdf
Referenced Standard and Year(of Standard) Standard Year
ANSI/DASMA 108 2005
ANSI/DASMA 115 2005
ASTM E330 2002
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgt45Hla2AP3I3... 2/15/2016
Florida Building Code Online Page 2 of 3
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 03/19/2015
Date Validated 03/25/2015
Date Pending FBC Approval 03/29/2015
Date Approved 06/23/2015
Summary of Products
Go to Page = a Page 2/2 Va
FL# Model,Number or Name Description
5�68�'4121 -
2148-09 DSIU-IF171: 9200, Double-skin Insulated PUR(exterior skin 27 ga. min.;
9201,9203,HDP20, HDPF20, interior skin 27 ga.min.)Single-Car(up to 9'0"wide)
HDPL20,7200,7201,7203,8200, WINDCODE@ W8 Garage Door
8201,8203
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL5684 R7 II 104185-Rev01-sioned.odf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +48 PSF/-60 PSF Evaluation Reports
Other: Max.Wind Speed (V_ult): 170 MPH.Optional FL5684 R7 AE CBPC 111215-A.odf
Impact Resistant Glazing available. Created by Independent Third Party: No
5684.22 22 W8-16 DSIU-11`171: 9200, Double-skin Insulated PUR(exterior skin 27 ga. min.;
9201,9203,HDP20, HDPF20, interior skin 27 ga. min.)Double-Car(9'2"to 167"wide)
HDPL20,7200,7201,7203,8200, WINDCODE@ W8 Garage Door with Optional Impact-
8201,8203 Resistant Lites
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL5684 R7 II 104280-RevOI-signed.pdf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +46.6 PSF/-52 PSF Evaluation Reports
Other: Max.Wind Speed(V_ult): 170 MPH.Optional FL5684 R7 AE CBPC 111215-A.odf
Impact Resistant Glazing available. Created by Independent Third Party: No
5684.23 23 W8-18 DSIU-1F171: 9200, Double-skin Insulated PUR(exterior skin 27 ga. min.;
9201,9203, HDP20, HDPF20, interior skin 27 ga. min.) 16'4"to 18'2"wide WINDCODE@
HDPL20, 7200,7201,7203,8200, W8 Garage Door
8201,8203
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL5684 R7 II 104281-RevOl-sianed.pdf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +46 PSF/-50 PSF Evaluation Reports
Other: Max.Wind Speed(V_ult): 170 MPH. FL5684 R7 AE CBPC 111215-A.odf
Created by Independent Third Party: No
5684.24 24 W8-09 DSIUO-1K479: Canyon Double Skin Insulated PUR(exterior skin 27 ga. min.;
Ridge/Glenmoor interior skin 27ga. min.)with Overlay Single-Car(up to 9'0"
wide)WINDCODEO W8 Garage Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL5684 R7 II 104277-Rev02-sioned.pdf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +54 PSF/-60 PSF Evaluation Reports
Other: Max.Wind Speed (V_ult): 170 MPH. FL5684 R7 AE CBPC 111215-A.odf
Created by Independent Third Party: No
5684.25 25 W8-16 DSIUO-1K479: Canyon Double Skin Insulated PUR(exterior skin 27 ga. min.;
Ridge/Glenmoor interior skin 27ga. min.)with Overlay Double-Car(9'2"to
16'2"wide)WINDCODE@ W8 Garage Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL5684 R7 II 104278-Rev02-sianed.pdf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +46.6 PSF/-52 PSF Evaluation Reports
Other: Max.Wind Speed(V_ult): 170 MPH. FL5684 R7 AE CBPC 111215-A.odf
Created by Independent Third Party: No
5684.26
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgt45Hla2AP3I3... 2/15/2016
These Tables Are For GARAGE DOORS.IN
One and Two Family Dwellings
Garage Doors Installed In Buildings with a
Mean Roof Height of 30' or Less Located in Exposures B, C or D
Table R301.2(2) of the 5th Edition FBG Residential
COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE [PSF]
❑160 EXPOSURE!B 9'x 7' Door=+24.3 -27.5
❑160 EXPOSURE1B 16'x 7' Door=+23.3 -26.0
0:1160 EXPOSURE-C-9'-x--7-'Door!.=+2�9.5� 33.3 (1 story and max 15'
❑T60 EXPOSURE C 16'X 7' Door=+28.2 -31:5 mean roof height)
❑160 EXPOSURE C 9'x 7' Door=+34.1 -38.5 (2 story and max 30'
r-11 60 EXPOSURE C 16'X 7'Door=+32.7 -36.4 mean roof height)
1-1160 EXPOSURE D 9'x 7' Door=+35.8 -40.5 (1 story and max 15'
❑160 EXPOSURE D 16'x 7' Door=+34.3 -38.3 mean roof height)
❑160 EXPOSURE D 9'x 7' Door=+40.4 -45.7 (2 story and max 30'
171160 EXPOSURE D 16'x 7' Door=+38.7 -43.2 mean roof height)
❑150 EXPOSURE B 9'x 7' Door=+21.3 -24.1
Ell 50 EXPOSURE B 16'x 7' Door=+20.4 22.7
❑150 EXPOSURE C 9'x 7' Door=+25.8 -29.2 (1 story and max 15'
❑150 EXPOSURE C 16'x 7' Door=+24.7 -27.5 mean roof height
❑150 EXPOSURE C 9'x 7' Door=+29.9 -33.8 (2 story and max 30'
❑150 EXPOSURE C 16'x 7' Door=+28.6 .-31.8 mean roof height)
❑150 EXPOSURE D 9'x 7' Door=+31.4 -;35.5 (1 story*and max 15'
❑150 EXPOSURE D 16'x 7' Door=+30.0 -33.4 mean roof height)
❑150 EXPOSURE D 9'x 7' Door=+35.4 -40.1 (2 story and max 30'
17150 EXPOSURE D 16'x 7' Door=+33'.9 -37.7 - mean roof height)
Notes•-
■ Secure existing bucks per the Product Approval or Design Professional
Instructions prior to installing the door. Have product approvals
available at the time of inspection.
Glazing in Garage doors must comply with R301.2.1.2 (Glazing must
be impact resistant or shuttered)
Miami Dade N.O.A or Florida Product Approval# ����