FL# FL10124-1117
Application Type Revision
Code Version 2014
Application Status Approved /l
FPr. f
St I��%
Comments
Archived ❑ tl '
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,NJ 07054
(973)872-4421
lindareith@trinityerd.com
Authorized Signature Beth McSorley
lindareith@trinityerd.com
Technical Representative Beth McSorley(current)
Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(973)872-4421
bmcsorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/14/2016
Validated By John W. Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10124 R17 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
TAS 107 1995
Equivalence of Product Standards
Certified By
Sections from the Code
https://floridabuildin2.or2/pr/pr app dtl.asDx?param=wGEVXOwtDauracBeVCbdMONZ... 2/22/2016
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 12/16/2015
Date Validated 12/16/2015
Date Pending FBC Approval 12/19/2015
Date Approved 02/10/2016
Summary of Products
FL# Model,Number or Name Description.
10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,laminated,5-tab and hip/ridge
asphalt shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10124 R17 II 2015 12 FINAL ER GAF Asphalt
Approved for use outside HVHZ:Yes Shingles F1_10124-R17.odf -
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other: Refer to ER,Section 5. Evaluation Reports
FL10124 R17 AE 2015 12 FINAL ER GAF Asphalt
Shingles FL10124-R17.pdf
Created by Independent Third Party:Yes
Back Next
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
® R
secnri ntt:Tnres'
a
https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDq uracB eV CbdMQNZ... 2/22/2016
EXTERIOR RESEARCH&DESIGN,.LLC.
Certificate of Authorization#9503
TRI` .I� 353 CHRISTIAN STREET,UNIT#13
N ERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
GAF Evaluation Report 01506.01.08-1119
1 Campus Drive FL10124-1117
Parsippany, NJ 07054 Date of Issuance:01/03/2008
Revision 19:12/15/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida:The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use, of the product under the Florida Building Code and Florida Building Code,'Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by: tt�\ettr,l„�--
fPy�ry`•�!�
RobertJ.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert Nieminen,
'.. ,�� rtau P.E.on 12/15/2015.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 z document.Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor-does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued..
4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used,for permitting or design guidance unless retained
specifically for that purpose.
ROOFING SYSTEMS EVALUATION:
-1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
following sections of the Florida Building Code and Florida Building Code, Residential Volume. through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/
Conditions of'Use set forth herein.
2'. STANDARDS:
Section Property Standard Year
1507.2:4,R905.2.3 Physical Properties ASTM D1970 2009
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7:1,111905:2.6.1 Wind Resistance ASTM D7158 2068
1507.2.7.1,11905.2.6.1 Wind Resistance TAS 107 1995.
3. REFERENCES:
Kngtt Examination Reference Date
GAF(PDM-1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012
PRI(TST5878) Physical Properties GAF-025-02-01 03/27/2002
PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011
PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 01/12/2000
UL(TST 1740) TAS 107 94NK9632 03/29/2000
UL(TST'1740) ASTM D3462 01NK06632 02/02/2001
UL_(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001
UL(TST 1740) ASTM D3161 01NK37122 12/18/2001
UL(TST 1740) ASTM D3462 01NK37122 12/19/2001
UL(TST'1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161 03CA5367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST.1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
UL(TST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006
UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41095. 12/27/2006
UL(TST'1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL(TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007
UL(TST'1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008
UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008
Exterior,Research and Design,I.I.C. Evaluation Report 01506.01.08-1119
Certificate ofAuthorization#9503 FL10124-1117
Revision 19:12/15/2015
Page 2 of 6
"�TWITY I ERS- --- -
Entitv Examination Reference Date
UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009
UL(TST 1740) ASTM D9161,.D7158,D3462 .091\11<06647 08/01/2009
UL(TST 1740) ASTM D3161,D7158,03462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA35554 03/05/2010
UL(TST.1740) ASTM D3161,D7158,03462 lOCA13686 05/15/2010
UL(TST 1740) ASTM D3462, 10CA07264 05/27/2010
UL(TST 1740) ASTM D3462 10CA11953 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IONK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10NK12070. 11/04/2010
UL(TST 1740) ASTM D3161,D7158,03462 08CA06160 01/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10CAS3934 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA479.19 12/03/2011
UL(TST 1740) ASTM 03161,D7158,D3462 11CA48409 12/08/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011
UL,LLC.(TST 9628) ASTM D3462. 12CA34891 i.0/12/2012
UL,LLC(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013
UL,LLC.(TST 9628) ASTM 03161 13CA37934 08/02/2013
UL,'LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 06/19/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 07/21/2015
UL,LLC:(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 06/26/2015'
UL,LLC.(QUA 9625) Quality Control. Inspection Report,R21,Michigan Cty,IN 05/14/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Shafter,CA 07/16/2015
UL LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 06/24/2015
UL,LLC,(QUA 9625) Quality Control Inspection Report,R21,Minneapolis,MN 07/14/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,W.Vernon,IN 07/10/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 01/21/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,.FL 06/26/2015
UL LLC.(QUA 9625) Quality Control Inspection Report,921,Dallas,TX 07/15/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 07/09%2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 07/16/2015
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1,1 Marquis® WeatherMax®, Royal Sovereign' and, Sentinel® are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot®,Camelot®II,Country Mansion® ll,Glenwood'",Grand Canyon®,Grand Sequoia®,Grand Sequoia®
IR, Monaco®, Sienna®, Timberline American Harvest°, Timberline® ArmorShieldTM' II,Timberline® Natural
Shadow®, Timberline HD®, Timberline® Cool Series, Timberline Ultra HD® and Woodland°,are fiberglass
reinforced,laminated asphalt roof shingles.
4.1.3. Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip&Ridge Shingles:
4.2:1 Seal-A-Ridge® Ridge Cap Shingles, Seal A-Ridge° IR Impact-Resistant Ridge Cap Shingles and Timbertex®
Premium Ridge Cap Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Starter Strips:
4.3.1 Pro-Startl-Starter Strip Shingles.and WeatherBlocker'"" Premium. Eave/Rake Starter Strip are starter strips
for asphalt roof shingles.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1119
Certificate of Authorization 119503 FL10124-R17
Revision 19:.12/15/2015
Page 3 of 6
` TKINITY ERS --
4.3.2 QuickStart®°Peel &Stick Starter Roll is a is.a mineral-surfaced,fiberglass-reinforced,,self-adhering-SBS modified.
bitumen starter strip,nominal 9=inch x 33 ft roll,for use with asphalt shingles with exposure of 6-7inch or less.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.4 Wind Classification:
5,4:1. The GAF.asphalt shingles.noted,in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM 03161, Class F and/or ASTM D.7158,Class H, indicating ther shingles are.acceptable for
use in all wind zones up-to V,,d=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements
to.meet:this wind rating.
5.4.2. The GAF hip &ridge shingles noted in Section 4.2,are Classified in accordance with FBC Tables 1507.2.7.1.
and R905.2.6.1 to ASTM D3161,Class F,indicating-.the shingles are acceptable for use in all wind zones up to
Vwd=150 mph(V.it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM.D7158 applies to exposure category B or C and a building height of 60 feet or less,
Calculations by a qualified design professional are required for conditions outside these limitations.
Contact the shingle manufacturer for data specific to each shingle.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C.'Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or 11905.2.3.
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation .of Pro-Start Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip and
QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current,published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
y Camelot,Camelot II,Grand Canyon,Grand Sequoia,Grand Sequoia IR, and Woodland require minimum
five(5)nails per shingle.
➢ Slateline requires minimum six(6)nails per shingle.
6.3.2, Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the shingle manufacturer for details.
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1119
Certifu:ate of Authorization#9503 FLiD124-1117'
Revision 19:12/15/2015
Page 4 of 6
QOTRINITYIERD
6.4 Hip,&Ridge Shingles:
6.4.1. Installation of'.Seal-A-..Ridge Ridge Cap Shingles and Seal-A-.Ridge IR Impact-Resistant Ridge,.Cap.Shingles shall
comply with'the;manufacturer's currenrpubltshed instructions with a minimum two(2)nark, minimum 3/8-
inch head diameter; per'shingle,and nominal 0:25=inch diameter beads of Henkel ".Loctite PL S30 'Koof &
Hashing Sealant". -
" Sealant
(292 M`0
(25 mm) , tn'd to
Enduit d'etancheite
Nail (305 mm)
Cavo
6518"-75/8" Clover.
;(168 194 mm)
i.
6:4.2. Installation of Timbertex'`Premium Ridge Cap Shingles shall 'comply:'with the manufacturer's current.
published.instructions with,a minimum two .(2) nails, minimum 3/.8-inch: head diameter, per shingle and.
beads of Sonneborn NPI Gun'Grade Polyurethane.Sealant.or Henkel PL Roofing and Flashing"Sealant.
6eWnrrt
6.4.3' Fasteners shall be in accordance-with the manufacturer's published requirements, but:not less than fBC.
1507 2 6 or 11905,2.5. Staples;are not permitted:
.Exterior.Research and Design,LLC Evaluation Rep or['015 16.01._8-1119-
Certificate.ofAuthorization#9503 FL10124-1117
Revision,19:.12 j15/2015
Page 5 of 6
l PON, 11Y ERL7
7., LABELING:
7.1 Labeling shall b.e in,accordance with the requirements the Accredited, ;Quality Assurance Agency noted
herein.,
7..2 Asphalt shingle wrappers shall indicate compliance with:one:of the,required'classifications;detailed in,FBG
Table 1507 2;7,1/,R905.2.6:1. .
8.. BUILDING PERMIT REQUIREMENTS:
As required by the,B,uMin g-Official or Authority Having Jurisdiction`in order to properly evaluate:the installation;of
this product:
9- MANUFACTURING PLANTS:
Contact the named QA entity for information.on which plants produce products:covered by Florida Rule 61G20-1 QA
requirements.
10. QUALITY.ASSURANCE ENTITY:
UL LLC—O A9625{.(847)_664-3281
- END.OF EVEILUATION'REPO-,RT
Exterior,Research and D.esig'n,LIC. Evaluation-Report 01506.0108-A19_
Ce_rtifr`cafe of Authorization#9503 FL10124=1117
Revision.19::12%15/2015.