Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 or.2 ulv K �' `�� .� err• F(cnda DeparbTk ntd BCIS Home Log In User Registration Hot Topics SubmitSuicharge I Stats&Facts Publications: FBE Staff BCIS Site Map Links I Search Businest�" „rofessiali = Product royal PP USER:Public User Regulation Product Approval Menu>Product or Aoolication Search>Aoolication List>Application Detail FL# FL11602=113 Application Type Revision Code Version 2014 Application Status Approved Comments t Archived, ❑ l 1, I L Product Manufacturer InterWrap, In Address/Phone/Email 32923 Mission Way Mission';NON-US 00000 (551)574-2939 'm to pa's@ i nterwra p.com Authorized Signature Eduardo Lozano elbzanb@interwrap.com Technical Representative Eduardo Lozano Address/Phone/Email 32923 Mission Way Mission;NON-US 00000 (778)945-2891 el,ozano@interwrap.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer (� Evaluation Report-Hardcopy Received Florida Engineer or'Architect Name who developed. Robert Nieminen the Evaluation-Report Florida License PE=59166 Quality Assurance Entity Intertek Testing Services NA Inc.-ETL/Warnock Hersey Quality Assurance;Contract Expiration Date 11/.19/2016 Validated By John W:Knezevich,PE 0 Validation Checklist-Hardcopy Received .Certificate of Independence FL11602 R3 COI 2015 01 COI Nieminen.Ddf Referenced Standard and'Year(of Standard) Equivalence of prod uct=Standards Certified By Sections from the Code 1507.2.3 1507.2.4 1507.2.8 1507.2.9.2 1507.3.3 1507.4.5.1 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K°/`2fI'r... 1/19/2016 Florida Building Code Online Page 2 of 2 1507.4.5.2 1507:5.3 1507.7:3 1507.8.3 1507.9.3 1523.6.5.2.1 Product Approval Method. Method 2 Option e Date Submitted 05/01/2015 Date Validated 05/01/2015 Date Pending FBC Approval 05/10/2015 Date Approved 06/22/2015 Summary of Products FL# Model,Number or Name Description 11602.1 Titanium RooNrlderlayments Synthetic sheet-type roof underlayments Limits of Use, Installation Instructions Approved for use in HVHZ-.No, FL11602 R3 tI 2015 O5 FINAL ER INTERWRAP_FL11602- Approved for use outside HVHZ:YesR3.ndf, Impact Resistant:N/A VeHfied�%y RobertNieminen:PE-59166 Design Pressure: +'N/A/=45 Created.byIndependent Third Party:Yes Other: 1.)The design pressure noted herein pertains to Evaluation Reports use of a specific underlaymerif system* beneath foam-on the FL11661 R3 AE 2015 05 FINAL ER INTERWRAP FL11602-: sytsems.Refer to.ER Section 5:6.3 for details.2.)Refer to R3.odf ER Sections 5 and 6 for other.Urhits of Use. Created,by Independent Third Party:Yes Back Next Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State'of Florida.::Privacv.Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead contact the office by phone or by traditional mail.If you have any questions;please contact 850.487:1395:`Pursuant to Section 455.275(1),Florida.Statute's,effective October I,2012,licensees.licensed under Chapter 455;F.S.must provide the Department vdth an'email address if. they have bne.The emails provided may be.used for offiicial'communkation with the licensee.'tiowever email addresses are public'record.If you do not wish to supply a personal address,please provide the:Department with an email address which can be made available to the public.To daermine'if you are a licensee under Chapter 455,F.S.,please click.here Product Approval Accepts:. W ®go M securitYM Fmucr http://www.floridabuilding.org/pr/pr_app_dtl,aspx,?param=wGEVXQwtDgsQFc5K`/`2fTr... 1/18/2016 EXTERIOR RESEARCH&:DESIGN,LLC. Certificate of Authorization#9503' QOTPtINITYIERD 353 CHRISTIAN STREET, UNIT 478 OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Inter_wrap,,l'nc: Evaluation Report 111980.11.08-R3 32923 Mission Way FL11602-113 Mission,BC V2V-6E4 Date of Issuance:11/.03/2008 Canada Revision 3:05/01/2015 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida:The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under he Florida Building Code.and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition.(2014)Florida Building Code sections noted herein. DESCRIPTION: Titanium'"Ir Roof U`nderlayments LABELING: Labeling shall be in accordance with the requirements the Accredited'Quality Assurance Agency noted.herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the,named products) changes; the referenced Quality Assurance documentation changes; or provisions of the Code that relate to the product change. Acceptance of'this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality.Assurance�documentation changes. Trinity:lERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:' The :Evaluation. Report number preceded by the words [Triniiyl!ERD: Evaluated" may be displayed in advertising literature. If any'portion of the Evaluation Report is:displayed,then it shall be clone in its entirety. - INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer,or its distributors and shall be available for inspection at the job site at the request.of the Building Official. This Evaluation Report consists of pages 1 through 6: Prepared by: - a- _ y - Robert J.M.Nieminen P.E: %F Thefacsim(lesealappcadngwasaulhori[edbyRbbertNieminen, `['S•''QiJ 7s,�' �, P.E.on 05/01/2015.This does not serve as an electronically signed , l.,r,Js L.`.... .lgrq.qty:1" Florida Registration.No.59166,:Florida DCA ANE1983 document.Signed,sealed hardcdpies have been transmitted to the ProAuct Approval Adminislratocand to the named client CERTIFICATION OFINOEPENDENCE: 1. Trinity IERD.does.not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates: 2. Trinity I ERD is not owned,,operated or controlled.by'any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P:E.,does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen;P.E.,does not have,nor will,acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained Specifically for that purpose. ��TRINIIYIERO' ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Titanium" Roof Underlayments, as produced by Interwrap, Inc:, have demonstrated compliance with the intent of thefollowing:sections of the Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditionsof Use set forth herein. 2. STANDARDS Section Property Standard year 1507,2.3;1507.3.3,1507.5:3;•1507:73; Unrolling;Breaking Strength,Pliability, ASTM D226 2006 T1507.8,1507.8.3,1507.9.3 Loss on Heating 1507.2.4,1507.2.8,1507:2.9.2, Thickness,Load-Strain,Adhesion,Thermal ASTM D1970 2009 1507.4.5.1,1507.4.5.2;.1507:5:3, Stability,Flexibility,Tear;Permeance 1507.5.3.2,1507.7.3,1507.7.3.2 1507.3.3 Installation Practice FRSA/TRI April 2012(04=12). 2012 1523.6.5.2.1 PhysicaLProperties(2-ply system) TAS 103 1995 TAS 110 Accelerated Weathering TAS 110 2000 3. REFERENCES: fafint Examination Reference Date ERD:(TST6049) Physical Properties 115010.04.09 04%29/20.09 ERD.(TS76049) Physical Properties 115010.05':10 05/14/2010 ERD:(TST6049) Physical Properties 135520.06.11 06/15/2011 ERD.(TST6049) Wind Uplift 135520.08.11-1 08/12/2011 ITS(TST1509) Physical Properties 3146738COQ-003A 03/28/2008 ITS(TST1509) Physical Properties 3146738COQ-0038 03/28/2008 ITS(TST1509) Physical Properties 3126617COQ-005 10/31/2007 ITS(QUA1673) Quality Control ITS Listings Current ITS(QUA1673) Quality Control Inspection Report 11/19/2014 4. PRODUCT DESCRIPTION: 4:1 Self-Adherine.Underlavments: 4:1.1 Titanium-- PSU=30 is an unreinforced polymer modified bitumen material adhered. to.the underside of a polymer- coated,synthetic woven sheet. The underside is backed with a release film. Unit weight 24 lbs/square. 4.2 Mechanically.Fastened UnderWnnents: 4.2.1 Titanium" UDL-25-is'a synthetic sheet-type underlayment comprised of a woven core coated on one side with a polymer coating. Unitweight 2.5 lb's/square. 4.2.2 Titanium"UDL=25.PLUS is a synthetic sheet-type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.9 lbs/square. 4.2.3 Titanium!' UD L-30 is a synthetic sheet-type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.0 lbs/square. 4.2.4 Titanium'" UDL-SO is a synthetic sheet-type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.7 Ills/square. 4.2.5 Titanium" UDL-TT is a synthetic sheet-type underlayment comprised of a woven core coated on one side with a polymer coating. Unit,weight 2:9 lbs/square 4.2.6 Titanium'" UDL-TF is a synthetic sheet-type underlayment comprised of.a woven core.coated on both sides with a polymer coating. Unit weight 2.9 lbs/square. 4.2.7 UDL-TTMC300 is a synthetic sheet-type underlayment comprised of a woven core coated on both sides with a polymer coating.. Unit weight 3.2 lbs/square. Exterior Research and Design,LLC. Evaluation Report 111980.11.08-R3 Certificate ofIAuthorizotion#9503 F1.11602-113 Revision Revision 3:05/01/2015. Page 2 of 6 TRINITY I ERD 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E: are, in any Way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof; is/was used for permitting or design guidance unless retained specifically for that-purpose. 5.2 This Evaluation Report is not for usein the HVHZ. 5.3 Fire Classification is not part of thisi report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Titanium"`Roof Underlayments may be used with any prepared roof cover where the product is:specifically referenced within FBC approval documents.. If not listed,a request may be made to.the AHI for approval based on this evaluation combined with supporting data for the prepared.-roof covering. 5.5 Allowable Roof Covers: Table : Roof Cover Options Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes& Slate Shingles Shingles PSU-30 Yes, Yes Yes Yes Yes Yes (See.5.5.11 UDL-25 Yes No No Yes Yes Yes Yes Yes UDL=25 PLUS. Yes (base layer in 2- (base layer in 2- Yes Yes Yes ply system) ply system) Yes Yes UDL-30. Yes (baselayerin 2- (base layer in 2- Yes Yes Yes ply system) ply system) UDL-50 Yes No No Yes Yes Yes UDL-TT Yes No No Yes Yes Yes UDL-TF Yes. No No' Yes Yes Yes `UDL-TTMC300 Yes No No Yes Yes Yes Private Labeled 5.5.1 "Foam-On Tile"is limited to use of 3M'"2-Component Foam Roof Tile Adhesive AH-160(F.L6332)or Dow TILE BOND"Roof Tile Adhesive(FLM) applications unless tensile adhesion/ long term aging.data from an accredited testing laboratory is provided. 5.6 Allowable Substrates;Titanium PSU-30: 5.6.1 Direct-Bond to Deck: ➢ New:untreated plywood;- ➢ Existinguntreated plywood,primed as needed with D41 primer to achieve bond. 5.6.2 Bond.to Mechanically Attached Base.Sheet: Y ASTM D226,Type I or II felt. Titanium UDL-25 PLUS,UDL-30'(primed with D41 primer)or U,DL-30(inverted). 5.6.3 Wind Resistance for Underlayment Systems in Foam-bn Tile.Applications: FRSA/TRI April 2012(04-12),does.not address wind uplift resistance of all underlayment systems beneath foam-on file systems,where the underlayment forms part of the load-path. The following,wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04'=12)and are used in foam,on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9:has already been applied).Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or FBC 1609 fc,r determination'of design wind loads. 5.6.3.1 Maximum Design Pressure=-45 psf. Deck: Min.15/32-inch plywood to meet project requirements,to satisfaction of AHJ. Primer: (Optional)ASTM D41 Underlayment: Titanium PSU-30,self-adhered Exterior Research and Design,LLC: Evaluation Report 111980.11.08-R3 Certificate o(Authodiation#9503 FL11602-R3 Revision 3:05/01/2015 Page 3 of 6 TRINIT Y I ERD 5.6.3.2 Maximum Design Pressure=-30 psf*. Deck: Min.15/32=inch plywood to.meet project requirements to satisfaction of AHJ. Base Sheet: Titanium UDL-25 PLUS or UDL-30(inverted) Fasteners: .Mechanically attached with 12 ga.annular ring shank nails having not.less than 20 rings per inch, heads not less than 3/8 inch diameter and length-sufficient to penetrate through the thickness of deck not less than 3/16-inch with min.32 ga.,1-5/8"diameter tin caps Spacing:. 6-inch o.c:at 4-inch wide,;side laps and 12-inch o.c.at three(3),"equallyspaced centerrovvs. Primer: ASTM D41 primer required'at all-tin-caps. Underlayment; Titanium PSU 30,self-adhered 5.6.3.3 Maximum Design Pressure=-30 psf*. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Titanium UDL-30(printed side,up) Fasteners: Mechanically attached with 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch:diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min:32 ga., 1-5/8"diameter tin caps. Spacing: 6-inch o.c.at 4-inch wide side:japs and 124nch o.c.at three(3),equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: Titanium PSU 30,self-adhered 5.6.3.4 Maximum Design Pressure=-45 psf*. Deck: Min.15/32;inch plywood to,meet project requirements to satisfaction of AHJ. Base Sheet: Titanium,UDL-25 PLUS or UDL730(inverted) Fasteners: Mechanically attached with 12 ga,annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient topenetrate through the-thickness,of deck not less than 3/16-inch with min.32 ga.,175/8"diameter tin caps Spacing: fi-inch o.c.at 4-inch wide side laps and 8-inch o.c.at three(3),equally spaced center rows. Primer: ASTM D41 primer required at all tin-caps. Underlayment: Titanium PSU 30,self-adhered 5.6.3.5 Maximum Design Pressure=-45 psf*. Deck: Min.15/32-inch plywood:to meet project requirements to satisfaction of AHI. Base Sheet: Titanium UDL-30(printed side up) Fasteners: Mechanically attached with 12 ga.annular ring shank nails having,not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min.32 ga.,1-5/8"diameter tin caps. Spacing: 6-inch o.c.at 4-inch wide side laps and 8-inch o.c.at three(3),equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: Titanium PSU 30,self=adhered 5.6.3.6 For mechanically attached base sheet in a 2-ply system,the maximum design pressure for the selected assembly shall' meet or exceed the Zone 1 design pressure determined in accordance with FRSA/TRI April 2012(04-12),Appendix A, Table IA or.FBC 1609. Zones 2 and 3 shall employ an attachment density designed'by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD1. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.1.5.1(a)of FM LPDS 1-29 for Zone 2/3 enhancements 5.7 Exposure Limitations: Titanium UDL=25,UDL-25 PLUS,UDL-30,UDL-50,UDL-TT or UDL-TF shall not be left exposed for longer than 30-days. Titanium PSU-30 shall not be left exposed for longer than 90-days. UDL-TTMC300 not be left exposed for longer than 180-days. Exterior Research and Design,-LLC. Evaluation Report 111980.11.08-R3 Certificate of Authorizotion#9503 K11602-R3 Revision 3:.05/01/2015 Page 4 of 6 TRINIIY�ERD 6. INSTALLATION: 6;1 Titanium. Roof Underlayments shall be installed'in accordance with,Ir terweap published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6:2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and de.brispriorto application,and prime the substrate(if applicable). 6.3 _. . _-.Titanium-UDL-25 UDL-25 PLUS t1DL-30 UDL-50,UDL-TT,UDL-TF and(Private Labeled)UDL-TTMC300: 6.3:1 Install fn compliance with manufacturers published installation instructions and the requirements for ASTM D226,Type Iand.11 underlayments in FBC Sections 1507 for the type of prepared roof covering:to be installed.. 6.3.2 --.Fasteners: Mechanical attachment of Titanium UDL-25, UDL-25 PLUS and UDL-30 is limited to ring shank roofing nails with, minimum 1-inch diameter plastic caps. Mechanical attachment of UDL-50,UDL-TT,UDL-TF and(Private Labeled)UDL-TTMC300 is limited to ring shank roofing nails with minimum 3/8-inch diameter heads; ring shank roofing,nails with minimum 1-inch diameter plastic caps;, screws and plates;or plastic cap staples. 6.3.3 Slopes of 4:12 or greater:. End(vertical)laps shall be minimum 6-inches and side(horizontal)laps shall be minimum 4-inches. Minimum attachment shall be 12-inches o.c. vertically and 24-inches o.c. horizontally in accordance with the surface markings on the exposed face of the underlayment. When batten systems are.to be installed atop the underlayment, the underlayment need only be preliminarily attached,pending-attachment of the battens. 6.3.4 Slopes of 2:12 to less than 4:12: Double layer application;begin by fastening a 25-inch wide-strip;along the eaves. Place a full-width:sheet over the starter,completely overlapping the starter course. Continue as noted in 6.3.3,but maintaining minimum 25-inch side (horizontal)laps,resulting in-a double-layer application. 6.4 Titanium"PSU-30: 6.4:1 Install in compliance with manufacturer's published installation instructions and the.requirements for ASTM D1970 underlayments in FBC Sections1507 for the type ofprepared'roof covering to be installed. 6.4.2 Direct-to-Deck With MechanicallyFastened Roof Cover: Cut manageable sections and re-roll With the release film side out. Membrane Application: 'D Peel back release film approximately 1 to 2 feet and align.with the lower edge of the roof and set in place,printed side up. D Apply the balance of the membrane to the substrate by removing the film and'firmly pressing the membrane into place. Apply subsequent.courses.parallel to the eave in a shingle-type,water-shedding manner. ➢ End(vertical)laps shall-be minimum 12-inches and side,(horizontal)laps shall be minimum 3-inches. Ifthe membrane becomes misaligned,cut the roll and re-start. ➢ Upon completion,inspect the membrane and repair any defects-or fish-mouths. The use of sealant or mastic at the fastener penetrations is required for all tile roofing'installations. Contact Interwrap for approved sealant or mastic types. 6.4.3 Direct-to-Deck with Adhesive-Set Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Manual and'Table 1 and;Section 5.6.2 herein, using the instructions noted above as a guideline. Wait a minimum of 24 hours prior to loading roof tiles.Tiles shall be staged so as to avoid slippage and/or damage to the.roof underlayment. The.use of sealant or mastic at tile fastener penetrations is required for all tile roofing installations. Contact Interwrap for approved sealant or mastic types. Exterior Research and Design,LLC. Evaluation Report 111980:11.08-R3 Certificate of Authorization 09S03 FL11602-113 Revision 3:05/01/2015 Page 5 of 6 ��TRINITYIERD 6:5 Titanium 2-Ply System: 6.5.1 The Titanium System consists of a base layer of Titanium UDL-PLUS or UDL-30 (top-surface primed or inverted) mechanicallyattached to the wood roof deck followed by Titanium PSU-30,self-adhered. 6.5.2 Non-Tile Applications: Install Titanium UDL-25 PLUS or UDL-30'(top surface primed or inverted) in accordance with Sections 6.3.1 through 6.3.3 followed by'Titanium PSU=30 in accordance with Section 6.4. 6.5.3 Tile Aoplications: Reference is,:made to FRSA/TRI April 2012(04-12)Installation Manual-and Table 1 herein;using the instructions noted above as a guideline. For mechanically fastened the roofing,refer to Interwrap published'installation instructions,but not less than FRSA/TRI Apri12012(0412);Table 1. For adhesive-set tile roofing,refer to Section 5:6:3 herein. Wait a minimum of 24 hours priorto Ioading'roof tiles. Tiles shall be staged so.as to avoid slippage and/or damage to the roof underlayment. The use of sealant.or mastic at tile fastener penetrations is required for all tile roofing installations. Contact Interwrap for approved sealantor mastic types. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority,Having Jurisdiction in order to properly evaluate the installation of Phis product. 8. MANUFACTURING PLANTS: Contact the:named.QA agency for information.on production.locations covered by:F.A.C.Rule 61620-3 QA requirements. 9. QUALITY ASSURANCE''ENTITY: Intertek Testing Services NA Inc.-ETL/Warnock.Hersey—QUA1673;(604)520-3321 -END.OF EVALUATION REPORT_ Exterior Research and Design,U.C. Evaluation Report-111980.11.08-113 Certificate oJAathorization#9S03 FL11602-R3 Revision 3:05/01/2015 Page 6 of 6 $t ngerworld The leader in cap systems:technology Page 1 of'3 �d 1 (STINGER NEWS> } :,�I'HE�SYS'I'EM, I• • • • 1111 11 HAMMER TACKERS>CAP HAMMERS>CAP STAPLERS'>CAP NAILERS'>CAP FASTENERS>ROOFING NAILS a r , Cap fasteners are a recommended BEST PRACTICE installation by housewrap and roofing underlayment manufacturers like DuPont, Typar, Grace, and Titanium. Why?Because caps help seal out moisture^that can penetrate sidewatl and roofing fabrics. Caps provide better holding power than a nail or staple alone and that means reduced blow-offs and lateral slippage! It also means fewer fasteners are needed to get the job done. ............................................................................................................_........_..................................................................................... •........_. ..........,....._. 318"StaplePac for use with STINGER CH38 and CH38A CapMammers only =WER Each 2016.count STINGER 3/8"Staplepacindudes 12`-168 count reels of full I"plastic x collated caps and 24-84 count strips of All 3/8"staples s[tn �I Each,StaplePac will cover approximately 25 square •fid• 518"Pneumatic StaplePac for use wilh.STINGER CS58 Cap Stapler ably • Each 2000 count STINGER 518"StaplePac includes 10-200 count plastic collated caps and 20 100 count strips of 5/8"staples • Each StaplePac will cover approximately 25 square ' 7/8",1 114 8:1.112"Pneumatic StaplePac for use with STINGER CS150 Cap Stapler&Cro'ssfire Cap Stapler only - SRiRGeR formerly Crossfire StaplePac _yjITSTtRspi11 �•?� • Available'in 718",1-1/4-and t-t/2" ZTt ►:"4� ' 9nnae • Each 2600 count STINGER StaplePac includes 1.0-200-count reels of-full t'`plastic collated.caps and 20-100 count strips stepies • Each StaplePac will cover approximately 25 square .:STINGER NA.IIIPAC......................................................,..........,.....,..........................................,............,..•...............,....,........,.�,,,....... 1"Pneumatic NailPac for use with STINGER CN100 only, }•. � .h • Each 2000.count STINGER 1"NailPac includes_10_200-count reels of full I"plastic Z -x coliated'cap;and 10-200 count coils of wire collated,I"_electro-galvabaed ring shank 4 STl11B@p nails �<t'IV iN3nl'gc ';/ i. • Each.NailPac will cover approximately 25 square oes Here Plasti-Top®,and Round-Tope ProPacs for use with Hitachi NV50AP3 and Plasti- TackerPlus®'Cap Nailers only(Plasti-Tacker Pro'" for use with Plastic NallPac and ProPac only) _. • Available;In 7/8",1.1/4"and-2"lengths Qii Each 2800 count NailPac or PmPac includes 8-350-count reels of collated caps and 8- 350 count coils of wire collated,electrogalvanized ring shank nails Each NailPac or PraPac will cover approzknately 35';quare 1-114"NailPac or RolPac for use with STINGER RT2 or RT3 Cap Nailers only • Each 3000 count NailPac includes 2-1500 count reels of I collated steel dips and 2-1500 count coils of wire collated,eectro-galvaniied ring shank nails http://www.stingerworld.com/fasteners.asp 1/18/2016 �, COP-4 MIAMI-DARE COUNTY MIAP11 DARE " PRDUCT CONTROL SECTION n tirE � 11305 SW 26 Street, Roam 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) tvtian,i,Florida 33'175'-24'7,1 BOARD,AND CODE ADMINISTRATION DIVISION T(786)315-2590F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) GAF 1 Campus I)Hvc Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations -governing the use of cpnstruction materials.-File documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami, Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance put-poses. If this product or material fails to perform in the accepted manner, the tnaiutfacturer will incur the expense of such testing and the AIIJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the Fligh Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline.11W',Timberline Natural Shadow',and Timberline American Harvest Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA sliall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA. failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISE AUNT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and, shall be available for inspection at the job site at the request of the Building Official, This NOA revises NOA 13-0419.04 and consists of pages 1 through 6. The submitted documentation was reviewed by Juan E. Collao, R.A. NOA No.: 14-1022.20 MIAMI•DADECOUNTY Expiration Date: 02/21/17 Approval Date: 02/05/15 Page I orb ROOFING AsSENIBLY APPROVAL Category: Roofing Sul)-Catef!ol-y: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This approves GAF Timberline HW',Timberline Natural,ShadowO,and Timberline Aincrican Harvest'"' Shingles as manufactured by GAF as described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline HD's 13 x 39-/8" TAS 110 Fiberglass reinforced heavy weight asphalt "alrujitclia-ing roorshingle,with a laminate profile Locations#1,2,3,4,5,6,7 GAF Timberline Natural 13 x 39'/.8** TAS I 10 Fiberglass reinforced heavy weight asphalt Shadow`" roofshing1c, with a laminate profile Manufactui-ing Localiomv#1,2,3,4,5,6,7 GAF Timberline.American 13 '/,j-x 39"/8- TAS 110 Fiberglass reinforced heavy weight asphalt Harvest" roof shingle,with a laininate profile 1[anufactill-ing Locations#2,4,5,6 MANUFACTURING LOCATION 1. Tampa, FL 2. Michigan City, IN 3. Baltimore, MD 4. Myerstown, PA 5. Ennis,TX 6. Tuscaloosa, AL 7. Dallas,TX NOA No.: 14-1022.20 WM I-AM I-IDA D E COUNTY N�Ynjymp,mw Expiration Datc: 02/21/17 Approval Datc: 02/05/15 Page 2 of 6 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories, [tic. ASTM D3462 I I CA48924 10/24/1,1 Underwriters Laboratories, file ASTM 1)'3462 1 OCA21994 04/22/11 Underwriters Laboratories, Inc ASTM D3462 I OCA28717 07/26/11 Underwriters Laboratories, Inc. ASTM D3462 05CA47541 11/10/06 Underwriters Laboratories, Inc. ASTM D3462 06CA3 1580 11/30/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories, Inc. ASTM D3462 06NK05159 08/09106 PRI Asphalt Technologies, Inc. ASTM D3462 GAF-098-02-02 11/08/05 Underwriters Laboratories, Inc. ASTM D3462 02NK41809 08/11/02 Underwriters Laboratories, file. ASTM D3462 03)NK26444 10/17/03 Center for Applied Engineering ASTM D3462 257089 05/13/97 Underwriters Laboratories, Inc. TAS I47 OINK45803 04/13/94 U nderwi-iters Laboratories, Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories, Inc. TAS 107 04NK04273 02J20/04 Underwriters Laboratories, Inc. TAS 107 05CA42840 11111105 Underwriters Laboratories, Inc. TAS 107 02NK41 811 11/11/02 Underwriters Laboratories, Inc. TAS 107 03CA35209 10/17103 Underwriters Laboratories, Inc. TAS 107 04CA,QS50 08/30/04 Center,for Applied Engineering TAS 100257989 04/01/97 PRI AsplialtTeclino1bgies, Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies, Inc. 'CAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Teclinolo ies, Inc. TAS 1'00 GAF-101-02-01 1-02-01 9, 11/09/05 PRI Asphalt Tecllnologies, Inc. TAS 100 GAF-116-02-02 03/23/06 PRI Asphalt Technologies, Inc. TAS-100 ELK-083-02-01 10/16/02 ELK-08442-01 10/15/02 ELKI-085-02-01 10/14/02 ELK-086-02-01 10/24/02 EL,K-087-02-01 10/21/02 F LK-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 1'0/09/03 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratingsW this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. OF III I OW IPDA No.: 14-1022.20 MIAMI-DADECOUNTYM UJILOMe MEW Expiration Date: 02/271/17 Approval Date:02/05115 Page 3 o1.6 INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard.RAS 115, 2. Flashing shall be in accordance with Roofing.Application Standard RAS l l5 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout,shall be in.compliance with Detail W, attached. 5. Nailing shall be in compliance with Detail '13%attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of inanufacturing facility;and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMMADE COUNTY BUILDING PERMIT REQUIREMENTS 1. Application floe building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.12 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 14-1(122.20 MIAM4DADECOUNTY Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 4 of 6 DETAIL A COURSE LAYOUT DECK FULL 5th 17"OFF 4th 11" OFF 3rd 6"OFF 2nd FULL 1st MIAMI-DADE CO UNI Y NOA No.: 14-1022.20 � , •. , Expiration Date: 02/21/17 Approval Date:02/05/15 Page 5 of DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN 39-3/811 -a 14-1/2"-17-1/2" W, 14-112"-1.7-1/2"m) (306-445mm) 8-44 6-1/2" 9-1/2" .1 uide line (166-241—) a`14"�6-1/4" 13-1 -3 (337nini) Z 112" (146mm-159mm) tr 3 from bottom of shingle 7 elf seal adhesive on back ENHANCED NAILING PATTERN six nails per shingle* required by some local codes and required for enhanced Mad coverage on certain products. See limited warranty for details, Theseshingles MUST be nailed-a nominal 6"(152mm)frombottom of of shingle, above the cut outs, as shown. Nails must not be exposed. END OF THIS ACCEPTANCE MIAMI-DADECOUNTYIN NOA No.: 14-1022.20 saw Expiration Date: 01/21/17 Approval Date: 02/05/15 Page 6 of 6