Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code.Online Page l oft [{////yam} R,. f 0 t ■ Or a Depaifill'Ilt _ d BC15 Home � Lag to [ User,Regts[ration Hot Topics � Submit Surcharge [ Stats&Facts Publications FBC Staff [ SCIS Site Map [ Unks Search t Busines` - Rr6fessi4�'aI 13 USER:Pubic User Approval Regulation Product Approval Menu>Productor Application Search>Aoolication list>.Appncation Detail FL# FL11602=R3 Application Type Revision Code Version 2014 r ApplicationStatus Approved A' v Jy Comments .a tf Archived1 Product Manufacturer InterWrap,Inc. Address/Phone/Email 32923 Mission Way. Mission,NON-US00000 (55.1)574,-29.39 m to p a s@ i me rwra p:'co m Authorized Signature EduardoLozano elozano@interwrapxdm Technical Representative Eduardo Lozano. Address/Phone/Email 32923 Mission Way Mission,NON-US 00000 (778)945-2893 elozano@interwra pcom Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or-a Licensed Florida Professional Engineer W Evaluation Report-Hardcopy Received Florida Engineer or'Architect Name who developed' Robert Nie-minen the Evaluation Report Florida License PE759166 Quality Assurance Entity Intertek Testing Services NA Inc.-ETL/Warnock.Hersey Quality Assurance Contract Expiration Date L1/19/2016 Validated By John W.Knezevich,PE R Validation Checklist-Hardcopy Received Certificate of Independence FL11602 R3 COI 2015 01 COI Nieminen.odf. Referenced Standard and Year(of Standard) Equivalence of Product Standards Certified By Sections from the Code 1507.2.3 1507.2.4 1507:2.8 1507.2.9.2 1507.3.3 1507.4.5.1 http://www.iloridabuilding.org/pr/pr_app_dtl.aspx?param=wG CV XQ wtDgsQFcS K%2fI'r... 1/18/2,01-6 Florida.Building Code Online Page 2 of 2 iso7.a.s.z 1507.5.3 1507.7.3 1507.8.3 ,1507;9.3 1523.6.5.2.1 Product Approval Method Method 2 Option B Date Submitted 05/01/2015 Date Validated 05/01/2015 Date Pending FBC Approval 05/10/2015 Date Approved 66/22/2015 Summary of Products FL# Model,Number or Name Description 11602.1 Titanium Roof'Underlayments Synthetic,_sheet-type roof underlayments Limits of Use InstallationInstructions Approved for use in.HVHZ:No FL11602 R3 11 20T5.O5 FINAL ER INTERWRAP_ FL11602- Approved for use outside HVHZ4 Yes R3.5f Impact Resistant:N/A 'Verified'By Robert N1eminen PE-59166 Design Pressure: +N/A/-45 Created by Independent Third Party:Yes Other:1._)The design pressure noted herein pertains to Evaluation Reports use of a specific underlayment system beneath foam-on the FU1602 R3 AF.2015 05 FINAL ER INTERWR"AP 1`1_11602- sytsems.Refer to.ER,Section 5.6.3 for details.2,j Refer to R3. f' ER.Sections 5 and'6 for other Limits of Use. I Created,by Independent Third Party-Yes Back Next ContacRUs::.1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of.Fiorida is an AA/EEo employer.Copyright 2007-2013 State of Florida.::Privacy-Statement Accessibility Statement::Refund"Statement Under Florida law,email addresses aWpublic records."Ifyou do notwant your e-mail address released in response to a public-records request,do not send. electronic rirall to this'entity:Instead,contact the'officeby phone or by traditional mail.If you,have anyquestions;,,pfease contact 850.487:1395:"*Pursuant,to ,. Section 455.275(1),florida,Statutes;effective October 112011,_,Iiceosees Ilcen'sed under Chaptr 45S,F.S'..must provide,tAe Department with,an email address'- they.have one:The emails,provided may be.used for officlal communication-with the licensee.However email addresses are public record:,If you do not wish to supply a personal.address,please provide the Department with an email address which can be made available-io the public:To determine if you are a licensee under :Chapter 455,F.S.,please click ter&. Product Approval Accepts:. gts ®99 M scCllrityllimul.S littp://www.floridabuilding.org/pr/pr_app_dtl.aspk?param=wGEVXQwtDgsQFc5K%2tTr... 1/18/2016 EXTERIOR RESEARCH'&DESIGN,LLC. Certoc6te of Autiioriza'tion#9503 QITR�I V� 1 1 353 CHRISTIAN STREET,: UNIT#13 ERD OXFORD,CT 06478 P.HONE:.(203)262-9245 FAX:(203)262=9243 EVALUATION REPORT Interwrap,Inc: Evaluation,keporf'111980.11.08-R3 32923 Mission Way FL11602-R3 Mission,BC V2V-6E4 Date of Issuance:11/03/2008 Canada Revision 3:05/.01/2015 SCOPE: This Evaluation Report is issued under. Rule 61G20-3 and. the applicable rules and regulations- governing the .use of ,construction materials in the State of Florida The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under.the Florida Building Code,and Florida Building Code, Residential Volume. The.products-described herein have been evaluated for compliance,with the 5th Edition(2014)Florida Building Code sections noted herein. DESCRIPTION:I TitanIUMM Roof Underlayments LABELING: Labeling,shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This, Evaluation Report;is valid until such time as the named peoduct(s).changes, the referenced Quality Assurance documentation changes,or provisions of the.Code that relate to the product change. Acceptance of`this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality,Assurance,documentation changes. Trinityl ERD requires a complete review of this Evaluation Report relative to updatedCode requirements with each Code Cycle: ADVERTISEMENT: The Evaluation. Report number preceded by the words r'Trinityl.ERD Evaluated" may be displayed in advertising,literature. If'any portion of,the Evaluation Report isdisplayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of Phis entire Evaluation Report shall be provided to the user by the manufacturer or its distributors.and shall be available for inspection at the job site at the request of the Building Official This Evaluation Report consists of pages 1 through 6. Prepared by Payl^ta�rtrnrq��— F s [he facsimile seal appearing was,authorized by Robert Nleminen, Robert J.M.Nieminen;P.C. Sir L4 ` P.E.on050T2015;Thisdoesnotserveasanelectronical signed ou?. i i k g �i�...rr,..t«` Registration NO;59166;Florida DCA ANE1983 document;signed,sealed h touan es have ametransmitted eto the Florida- Product Approval Admintstratopand to the named client CERTIFICATION OFINDEPENDENCE:- 1. Trinity ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity[ERD is not owned,,operated.or controlled,by any company manufacturing or distributing products it•evaluates. 3. Robert'Nieminen,P:E:.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will'acquire,.a financial interest in any other entity involved'in the approval process of the product. 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen;P,E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless,retained specifically'for that purpose, QOTRINIIYIERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category.: Underlayment Compliance Statentent: Titanium'" Roof Underlayments,as produced by Interwrap, Inc., have demonstrated compliance with the intent of the:following:sections of the Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subjectto the Installation Requirements and Limitations/Conditions.of Use set fortfi herein. 2. STANDARDS: Section Property Standard Year 1507x3.3;15073.3,1507.5.3,,1507.7.3; Unrolling;Breaking Strength,Pliability, ASTM 1)226 2006 T1507.8i 15 07.83,1507.9.3 Loss on'Heating 1507.2.4;150 7.2.8,.1507.2.9.2, Thickness,Load-Strain,Adhesion,Thermal ASTM D1970 2009 1507.4.5:1,1507.4.5.2,1507.5:3, Stability,Flexibility;Tear,Permeance 1507.5:3.2,1507.7:3,1507:7.12 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012 1523.6.5.2.1 Physjcal:Properties(2-plysystem) TAS-103 1995 TAS 110 Accelerated Weathering TAS`110. 2000 3. REFERENCES: Kniiti Examination Reference Date ERD'{TST6049) Physical Properties 11501.0.04:09 04/29/2009 ERD,(TST6.049) Physical Properties 115010 .05:10 05/14/3,010 ERD:(TST6049) Physical Properties 135520.06'.11 06%15%2011 ERD(TST6049) wind Uplift 135520.08.114 08/12/2011 ITS(TST1509) PhysicaWroperties 3146738COQ-003A 03/28/2008 ITS;(TST1509) Physical Properties 3146738COQ70038 03128/2008 ITS(TST1509) Physical`,Properties 3126617COQ-005' 10/31/2007 ITS.(QUA1673) Quality Control ITS Listings Current ITS(QUA1673) Quality Control Inspection Report; 11/19/2014 4. PRODUCT DESCRIPTION: 4.1 Self-Adherine.Underlayments: 4.1.1 Titanium'" PSU-30 is an unreinforced polymer modified bitumen material adhered to the underside of a polymer coated,synthetic woven sheet. The underside is backed witha release'film. Unit weight 24 lbs/square. 4:2 fMechanically.Fastened Underlayme its: 4.2.1_ Titanium'" UDL-25 is'a synthetic sheet-type underlayment comprised of a woven core.coated on one side with a polymer coating. Unit weight 2.5 lbs/square. 4.2.2 Titanium`"UDL-25 PLUS is a synthetic.sheet-type underlayment.comprised of a-woven core coated on one side with a polymer coating. Unit weight 2,9 lbs/square. 4.2.3 Titanium'" UDL-30 is a synthetic sheet=.type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.0 lbs/square: 4.2.4 Titanium'" UDL-SO is a synthetic.sheet-type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.7165/square: 4.2.5 Titanium!" UDL-TT is a synthetic sheet-type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.9'lbs/square 4.2.6 Titanium"" UDL=TF is a synthetic'sheet=type underlayment comprised of a Woven core coated on both sides with a polymer coating. Unit weight 2.9 Ilis/square. 4.2:.7 UDL-TTMC300 is a synthetic sheet-type underlayment comprised of a woven;core coated on both sides with a polymer coating., Unit weight 3.2 lbs/square. Exterior Research and Design,LLC. Evaluation Report 111980.11.08-R3 Certificate of uthorieation A9S03 FL11602-R3 Revision 3:05/01/2015 Page 2 of 6 TRINIW, IERD 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinityl ERD nor Robert•Nieminen, P.E;are, inany way, the Designer of Record for any project on which this Evaluation Report; or previous versions thereof; is/was used for permitting or design-guidance"unless retained specifically for that purpose. 5.2 This Evaluation Report is not formse:in the HVHZ. 5.3 Fire Classification not part of this report;refee,to current Approved Roofing Matefials.Directory for fire ratings of this product. 5.4 Titanium`"Roof Underlayments may be.used with any prepared roof cover where the product is specifically.referenced within FBC approval documents. If not listed,'aaequest may be made.to-the AH1 IFor:approGal based on:this evaluation combined with supporting data for the prepared,roof covering. 5.5 Allowable Roof Covers: Table 1: Roof Cover Options Asphalt` Wood Shakes.& Underlayment Shingles Nail-On Tile Foam-On Tile Metal. Shingles Slate PSU-30 Yes Yes Yes Yes Yes Yes UDL-25 Yes No No Yes, Yes Yes Yes Yes UDL-25.PLUS Yes (base layer in 2- (base layering- Yes Yes Yes ply system). plvsystem) Yes Yes UDL-30: Yes (base layer in 2- (base layer in 2_ Yes Yes Yes ply system) ply system) UDL-50 Yes No No Yes Yes Yes UDL-TT Yes No No Yes Yes Yes UDL-TF Yes No No Yes Yes Yes 'UDL-TTMC300 Yes' No No Yes Yes Yes Private labeled 5.5.1 "Foam-On Tile"is 1im ted to use of 3101"2-Component Foam Roof Tile Adhesive AH-160_(171_6332);or Dow TILE BOND'"Roof Tile Adhesive(FL747j applications unless tensile adhesion] long term aging data from an accredited testing laboratory is provided. 5.6 AlIowa bleSubstrates:Titanium PSU-30: 5.6.1 Direct-Bond to Deck: ➢ New:untreated plywood;. ➢ Existing-untreated plywood,primed as needed with D41 primer to achieve bond. 5.6.2 Bond to Mechanically Attached Base.Sheet: Y ASTM 0226,Type I or II felt. Titanium UDL725_PLUS,UDL-30(primed with D41 primer)or UDL-30(inverted). 5.6.3 Wind Resi"stanceJor Underlayment.SVstems'in Foam-On Tile Applications: FRSA/TRI April 2012(04-12)does not address Wind uplift-resistance.of all underlayment systems beneath foam-on the systems,where the underlayment forms part of the load-path. The following wind uplift:limitations apply to underlayment systems that.are not addressed,in FRSA/TRI April.2012(04=12)andare.used in foam-on tile applications. Maximum Design_Pressure is the result oftesting for wind-1 oa dresistance.based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2.to I margin of safety;•per FBC 1504.9.has already been applied).Refer to FRSA/TRI April 2012(04-12),Appendix A,Table.1A or FBC 1609,for determination of design wind loads. 5.6.3.1 Maximum Design=Pressure=-45 psf. Deck: Min.15/32-inch plywood'to meet project requirements to satisfaction of AHJ. Primer: (Optional)ASTM D41 Underlayment: Titanium PSU-30,self-adhered Exterior Research and Design,I.I.C. Evaluation Report 111980.11.08-R3• Certificate of Authorization/19503 FL11602-113' Revision 3:05/01/2015. Page 3 of 6 VTRINIW�ERD 5.6.3.2 Maximum Design Pressure=-30 psf*. Deck: Min.15/32-inch plywood to,meet project requirements to satisfaction of AHJ. Base Sheet: Titanium UDL-25 PLUS or UDL-30(inverted) Fasteners: Mechanically attached with 12 ga.annular ringshank nails having not less than 20 rings per inch,. heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with'min.32 ga.;1-5/8"diameter tin caps Spacing: 6-inch o.c.at 4-inch wide;side laps and 12-inch ox.,at.three(3),equally spaced;center rows. Primer: ASTM D41 primer required at all tin-caps. Underlayment: Titanium PSU 30,self-adhered 5.6.3.3 Maximum DesignTressure=-30 psf*. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Titanium.UDL-30(printed side°up) .Fasteners: Mechanically attached with 12 ga. annular ring shank nails having,not less than 20 rings per inch, heads not less than 3/8 inchr diameter and length sufficlent,to.penetrate through the thickness of deck not-less than`.3/16-inch with min:32 ga., 1.518"diameter tin caps. Spacing: 6-inch o.c.at 4-inch wide sid-e-laps and 12-inch o:c.,atthree(3),equally spaced center rows. Primer: ASTM D41 pr'mer requited.over printed side of UDL-30. Underlayment: T,itanium.PSU 30,self-adhered 5:6.3:4 Maximum Design Pressure=-45 psf*. Deck: Min.15/32-inch plywood torn eet project requirements to satisfaction of AHJ. Base Sheet: Tiitanium,UDL-25 PLUS;or UDL-30(inverted) Fasteners: Mechanically attached with 12 ga.annular ring shank.nails having not lessthan 20 rings per inch, heads not less,than 3/8:inch diameter.and length sufficient to:penetrate through the thickness of deck not less than 3/16-inch with,min.32 ga.,.1-5/8"diameter tin caps Spacing: 6-inch o.c.at 4-inch wide side laps and 8=ihch.o.c.at three(3),equally spaced center rows. Primer: ASTM D41.prinier requiredat all tin'-caps. Underlayment: Titanium'PSU 30,self-adhered 5.6.3.5 Maximum Design Pressure=-45 psf!. Deck: Min..15/32-inch plywoodto�meet project requirements to satisfaction of AHJ. Base Sheet: Tifanium!U.DL730(printed sideup) Fasteners: Mechanically attached with 12 ga.annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch.diameter and.length,sufficient to penetrate through the thickness of deck not less than 3/16-inch with min.32 ga.,1-5/8"diameter tin caps.. Spacing: 6-inch o.c.at 4-inch wide side laps and 8-inch a.c.at three_(3),equally spaced center rows. Primer: ASTM b41.primer required over printed side of UDL-30. Underlayment; Titanium.PSU.30,self-adhered 5.6.3.6 For mechanically attached base:sheetin a 2-ply system,the maximum design pressure for the selected assembly shall, meet or exceed the Zohe 1 design pressure determined in accordance with FRSA/TRI April 2012(04712),Appendix A, Table 1A or FBC 1609: Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 11-7, FM LPDS 1-29 and ANSI/SPRI WDl. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.1.5.1(a)of FNI LPDS 1-29 for Zone 2/3 enhancements 5.7 Exposure Limitations: Titanium UDL-25,UDL-25 PLUS,UDL-30,UDL-50,UDL-TT or UDL-TF shall not be left exposed for longer than 30-days. Titanium PSU-30 shall not be left exposed for longer than 90-days. UDL-TTMC300 not be left exposed for longer than 180-days. Exterior Research and Design,I.I.C. Evaluation Report 111980.11.08-R3 Certificate of Authorization#9503 FL11602-R3 Revision 3:05/01/2015 Page 4 of'6 I�RINI:TY IERD 6. INSTALLATION: 6.1 Titanium Roof.Underlayments shall be installed in accordance with Interwrap published installation requirements subject to the Limitations setforth in Section 5 herein and the specifics noted below. 6.2 Re-fasten anyloose decking panels, and check,for protruding nail heads. Sweep the substratethoroughly to remove any dust and debris,prio'r'to application;and prime the substrate(if applicable). .6.3 .Titanium'"UDL-25 UDL-25 PLUS UDC-30-UDL-50.UDL-TT,UDL-TF and(Private"Labeled)UDL-TTMC300: 6:3.1 Install'i compliance with mannf"aeturer`s published installation instructions and the requirements for ASTM D226,Type I and:ll underlayments in FBC Sections 1507 for the type of prepared roof covering-to be installed. 16.3.2____ Fasteners: _--_. - - - - - . . Mechanical:attachment of Titanium,UDL 25,'UDL 25 PLUS and UDL-30 is limited to ring shank'`roofing nails with} minimum 1-inch diameter plastic caps._ 1 Mechanical attachment of UDL-5Q UDL,=TT,UDL-TF and(Private Labeled)UDL-TTMC300.is limited to ring shank roofing nails with minimum 3/8-inch diameter heads; ring shank roofing nails with minimum 1-inch"diameter plastic caps; screws and plates;or plastic cap staples. 6.3.3 Slopes of 4:12 or greater: End(vertical)Laps shall be minimum.64nches and side(horizontal)laps shall be minimum 4-inches. Minimum attachment shall be 12-inches o.c:vertically and 24-inches,o.c. horizontally in accordance with the surface markings on the-exposed face of the underlayment. When batten systems are•.to be.installed atop the.underlayment; the underlayment need only be preliminarily attached pending attachment of the battens. 6.3.4 Slopes of 2:12..to less than 4:12: Double layer application; begin by fastening a 25-inch wide strip;along the eavess. Place a full=width sheet,over the, stafter,,completely overlapping the"starter course.. Continue as noted-in 6.3.3,but.maintaining.minimurn 25-inch-side (horizontal)laps.,resulting in-a double-layer application. 6.4 TitaniumT"PSU.-30: 6.4.1 Install in.compliance with manufacturer s published installation instructions and-the.requirements for ASTM D'1970 underlayments'in FBC Sections 1507 for the'"type of prepared roof covering to bedinstalled. 6.4.2 Direct=to=Deck with M'echanicallytastened Roof Cover: Cut manageable sections and re-roll with the release film side out. Membrane Application: ➢ Peel;back release film approximately 1;to 2 feet and align with the lower edge of the roof-and-set in place,printed side up. D Apply the,balance of the membrane to the substrate by removing the.film.and;firmly pressing the membrane into place. D Apply subsequen,t.courses parallel to the eave in a shingle-type,water-shedding.manner. Endr(vertical),laps shall:be minimum 12-inches and side(horizontal)laps shall be minimum,2I-inches. D Ifthe membrane'becomes misaligned,cut the roll and re-start. 'Upon-completion,inspect the rnembrane=and repair any defects or fish-mouths: The use:of sealant or mastic attlefastener penetrations is required for all tile roofing installations. Contact Ihterwrap for approved sealant or mastic types. 6.4.3 Direct-to=Deck with Adhesive-Set Tile Applications: Reference is madq to fRSA/TRI April 2012;'(04-12)Installation Manual and'Table,1 and'Section 5.62'herein, using the instructions noted above as a guideline. Wait a minimum of 24 hours prior to loading roof tiles.Tiles shall be staged so as to avoid slippage and/or damage to the.roof'underlayment. The use of sealant or mastic at the fastener penetrations is required for.ah tile roofing installations. Contact Interwrap for approved sealant or mastic types: Exterior Research and"Design,LLC. Evaluation Report 111980:11.08-113 Certificate of Authorization,#9503 FL11602-R3 Revision 3:05/01/2015 Page 5 of 6 ��TRINPYIERD 6.5 Titanium:2-Ply System: 6:5.1 The,Titaniuni System consists of a base layer of Titanium UDL-PLUS or UDL-30, (top-surface primed or inverted) mechanically attached to the wood roof deck followed by Titanium PSU-30;self-adhered. 6.5.2 Non-Tile Applications: Install Titanium U,DL--25 PLUS or UDL-30.(top surface primed,or inverted) in'accordance,with Sections 6.3-1 through 6.3.3 followed by Titanium PSU-30 in accordarice,with Section 6.4. 6.5.3 Tile Applications: Reference is made to FRSA/TRI April 2012(04=12)Installation Manual and Table 1 herein; using the instruction's noted above as a guideline. For mechanically fastened tile,roofing,refer to Interwrap published installation.instructions,but not less than FRSA/TRI April 2012(0.4-12);Table 1. For adhesive-set tile roofing,refer to Section 5.6:3 herein. Wait a minimum of 24 hours prior to loading roof tiles. Tiles shall be staged so as to avoid slippage and/or damage to the roof underlayment. The use of sealant or mastic at the fastener penetrations is required for all tile roofing installations. Contact Interwrap for approved sealantor mastic types. 7. BUILDING PERMIT REQUIREMENTS: AsTequired by the Building Official or.Authority Having Jurisdiction in orderto.properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the.named CIA agency for information on productionlocations covered by F.A.C.Rule 61G20-3 OA requirements. 9. QUALITY ASSURANCE ENTITY: Intertek Testing Services NA inc.-ETL/Warnock.Hersey—QUA1673;,(604)520-3321 -END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 111980.11.08-R3 Certificate of Authorization 0503 FL11602-R3 Revision 3:05/01/2015' Page 6 of 6 Sdrngerworld The leader in cap-systenis technology Page 1 of 3. -1 1 (.STINGER NEWS> .Tc eai SrNdER NW..C anti klpdat.. �.•- A� r'P1'I It • • • 1 � 71 HAMMER"TACKERS>CAP HAMMERS>CAP STAPLERS->CAP'NAILERS`>CAP FASTENERS;>ROOFING NAILS' r i , Cap fasteners are a recommended BEST PRACTICE installation by housewrap and roofing; undedayment manufacturers tike DuPont, Typar, Grace, and Titanium. Why?Because caps help seal out moisture1hat;can penetrate.sidewa11 �\ and.roofing fabrics. Caps provide better holding power than a nail or staple alone and that means reduced blow-offs and lateral slippage! It also, means fewer fasteners are needed to get the job done. ...................................._...............,.................................................,.,...............,...........................,-....-.. .................. _....._........-_..................._........ • 318"StaplePac for use with STINGER CH38 and"CH38A Cap Hammers only P data, trtlnHea:. • Each 2016 count STINGER 3/6"StaplePacindudes 12-168 count reels ofcfull L"plastic - collated.caps and 24•84 count strips of-AI'1.3/8"staptes •ctrl }(� J • Eads StaplePac will cover approximately 25,square 5/8"Pneumatic StaplePac for use with STINGER CS58'Cap;Stapler only • Each 2000 count STINGER 5/8'StaplePac includes 10•200 count plastic collated caps and 20.-100 count strips of 5/8"stables • Each StaplePac will cover apptoxiniately25.square 718",1414'!&1.1/2"Pneumatic StaplePac for use with STINGER CS150 Cap ° Stapler&Crossfire Cap Stapler only -•l >�itR6HR. °% = P. formerly Crossfire StaplePac �w` �pggp • Available in 7/8",1-1/4'and 1-112" Each 2000 count STINGER StaplePac'indudes 10.-200 count reels of full.V plastic collated caps and 20-100 count strips staples • Each StaptePac will cover approximately 25 square e•.....q,....w..n•.•.•.•:+.•::.•,..r.....•.•..:r.•...•.•.r.....•.•...•s......ea••..i::;r..,.,•...e•...ir.e•,•...•..n..,+.•.•.•.•.......•a.•e.......v..•.•.•....:e.r.•.�.r....•...::..:w.•...•.tie..,6.n.r:•.r�a:..._•.v..:.e....aa..:.........: STINGER NAILPAC 1"Pneumatic,NailP_ac for_use_with-STINGER CN100.only..�; Each:2000 count STINGER 1"NailPac includes,10-200 count,r&Js-or full V;plastic s - -a f coilated'caps and 10-'200 count coils of wire collated,V electro•galvamzed ring shank_ Si114 nails _. - "� ' • Each.NailPac will cover approximately 25 square r oes Here Plash-TopO.and Round-Top®ProPacs for use with Hitachi NV50AP3 and Plasti- Tacker Plus®Cap'Nailers only'(Plasti-Tacker Prom for use with Plastic NaitPad and ProPac only) • Available in 7/8",1-1/4"and.2"lengths j1{ • • Each 2800 count NailPac or ProPac includes 8­350,count reels of collated caps and 8- ,, 350 count coils of wire''collated,electrogalvanized ring shank nails 1� M Each NailPac or ProPac will cover approxiinately35 square 1-1/4"NailPac or RoWac for use with STINGER RT2 or RT3 Cap Nailers only • Each 3000 count NailPac includes 2-1500 count reels of I"collated steel caps and 2-1500 count coils of wire collated;electro-galvanised ring shank nails http://www.stingerw.orld.com/fasteners.asp 1/18/2016 c F�, MIAi1�i�l-DADSCOUNTY MIAM`�I DARETCNTROLSECTION 0 yEd FILE , Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315=2599 NOTICE OF ACCEPTANCE (NOA) www.Inixmidadc.cov/econonn' GAF 1 Campus Drive Pai•sippaiy,NJ 07054 SCOPE': This NOA"is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (Li Miami Dade County) and/or the AHJ (in areas "other than Miami Dade County) reserve the.right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in theaccepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, rood_ify, or suspend the:use of such product or material within their jurisdiction. RER reserves the right to revoke this"acceptance, if it is determined by Miami=Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product,is approved as described herein,and has been designed to comply with the Florida Building Code -including tlie.High Velocity Hurricane Zone of the Florida Building Code. I).ESCRIPTION: GAF TiniberlineHD"�,.Tiinberline Natural Sliadoww,and Tiniberline Ainerican Hat-vese° S111111glies LABELING: Each unit sliall'belr a permanent label with the manufacturer's name or logo;city,state and following statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shalt be considered after a renewal application has been filed and there has been no change in.the applicable building code negatively affecting the-performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials', use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,advertising orally other purposes shall automatically terminate.this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal.of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in.its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request:of the Building Official. This NOA revises NOA 13-0419;04 and consists of pages, I through 6. The submitted documentation was reviewed by Juan E. Collao, R.A. �Llt NOA No.: 14-1022.20 MIAMIDADECOUNTY Expiration Date: 02/21/17 i Approval Date: 02/05/15 1 Page I of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This,approves GAF Timberline HDA,Timberline Natural Shadowo,and Timberline American Harvese' Shingles as nianufactured by GAF as described in Section 2 of this Notice of Acceptance. PRODUCT DEsCRIPTION, Product Diffiensiblis Test Product.Description Specifications GAF Timberline HW 13 '11"x 39'/ ' TAS 110 Fiberglass reinforced heavy weight asphalt Manufticti(Nng roof shingle,wit.h a laminate profile Locations#1,2,3,4,,5,6,7 GAF Timberline Natural 13 '/4"x 39 318** TAS 110 Fiberglass reinforced heavy weight asphalt shadow'it, roof shingle,with a laminate profile A,faqufacturing Locations-#1,2,3$4,5, 6,7 GAF Timberline,American 13 V4"x 39'/8"'/8" TAS 110 Fiberglass reinforced)heavy weight asphalt Harv'egt roof shingle, with a laminate profile IVIC1171fact io-ing Locations#2,4,5,6 MANUFACTURING LOCATION 1. Tampa, FL, 2. Michigan City, IN 3. Baltimore, MD 4. Myerstown, PA 5. Ennis,TX 6. Tuscaloosa,AL 7. Dallas,TX NOA No.: 14-1022.20 M(MIAMI.DADE COUNTY Expiration Date: 02/21/17 Approval Date:02/05/15 Page 2 of 6 EVIDENCE SUBMirrE D Test Agency Test Identifier Test Name/Rem,t Date Underwriters Laboratories-,, Inc. . ASTM D3462 I I CA48q24 10/24/11 Underwriters Laboratories, [tic ASTM D3462 I OCA21994 04/22/11 Underwriters Laboratories, Inc ASTM D3462 I OCA28717 07/26/11 Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10/06 Underwriters Laboratories, Inc. ASTM D3462 06CA3 1580 11/30/06 PRI Asphalt Technologies, [tic, ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories, Inc. ASTM D3462 06NK051.59 08/09/06 8/09/06 PRI Asphalt Technologies, Inc. ASTM D3462GAF-098-02-02 11/08/05 Underwriters Laboratories, file. ASTM D3462 02NK41809 08/11/02 Underwriters Laboratories,Inc. ASTM D3462 03NK26444 10/17/03 Center for Applied Engineering ASTM D3462 257999 05/13/97 Underwriters Laboratories, [tic. TAS 1,07 OINK45803 04/13/94 Underwriters Laboratories, file. TAS 107 06NK05159 08/09/06 Underwriters Laboratories, Inc. TAS 107 04NK04273 02/20/04 Underwriter.,; Laboratories, Inc. TAS 107 05CA42840 11/11/05 UtWerweitcrs Laboratories, Inc. TAS 107 02NK41,811 1 1/1 1/02 Underwriters Laboratories, Inc. TAS 107 03CA35209 10/17/03 Underwriters Laboratories, [tic. TAS 107 04CA13850 08/30/04 Center for Applied Engineering TAS 100 257989 04/01/97 PRI Asphalt Technologies, Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies, lnc; TAS LOO GAF-098-02-01 I 1/08/05 PRI Asphalt Teclino.logies, [tic. TAS 100 GAF-101-02-61 11/09/05 PRI Asphalt Technologies,Inc. TAS [00 GAF-116-02-02 03/23/06 PR.I Asphalt Tcclinologies, Inc. TAS-100 ELK-083-02-01 10/16/02 ELK-094-02-01 10/15/02 ELK7085-02-01 10/14/02 ELK-086-02-01 10/24/02 ELK-087-02-01 10/21/02 ELK-088=02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 1 0/09/03 UmITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials,Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance With the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. IUMIAMI-DADECOUNTY-M NOA No.: 14-1022.20 329.• 4119OW Expiration Date: 02/21117 Approval Date: 02105115 Page 3 of 6 INSTALLATION 1. Shingles shall be installed in compIiance.with Roofing Application Standard RAS 115-. 2. Flashing shall be in accordance with Roofing Application Standard RAS L 15 3. The manufacturer shall provide clearly written application instructions. 4. Exposure'and course layout-shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Detail '13',attached. LABELLING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement:identifiable, County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. i MIAMI•DADE COUNTY: BU, LDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of:the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 14-1022.20 MIAMI•DADECOUNTY Expiration Dale: 02/21/17 f' ' iii' Approval Date: 02/05/15 Page 4 of 6 DETAIL A COURSE LAYOUT DECK FULL 5th 17"OFF 4th 11" OFF 3rd 6"OFF 2nd .FULL. 1 st MMIAMMIM=NTYNOA No.: Id-1022.20 Expiration Date:02/21/17 Approval Date:02/05/15 Page 5 of 6 DETAIL B Ow,RALL DIME,NSIONS AND NAILING PATTERN 393/811 j. (1 rn) 14-1/2"-17-1/2" 7-0— 14-1/2"-17-1/2" (306-445inm) (368-445mm) ail guide line, 3rl 6-1/2"-9-"1/2"" 5-34'-6-1/4"(3-j 1)4 (146m'm-1.59mm) from bottom of shingle /---Self seal If adhesive on back ENHANCED NAILING PATTERN - six nails per shingle* required by some local,codes and required for enhance&w1nd coverage on certain products. See limited warranty friedetails, These shingle's MUST be nailed a nominal 6" (1.52mm)from bottom of of shingle, above the cut outs, as shown. Nails must not be exposed, END OF THIS ACCEPTANCE M n1A M W�DA MDE CMO!UN nW NOA No.: 14-1022.20 Expiration Date: 02/21/17 Approval Date:02/05/15 Page 6 of 6 All Area Roofing & Construction, Inc. PURCHASE 3921 South US Highway 1 Fort Pierce, FL 34982 ORDER Purchase Order No.: 7802 Date Issued: 2/16/16 Delivery Date: Voice: 772-464-6800 Fax: 772-464-6600 ............. THE HOME DEPOT All Area Roofing &Construction, Inc. 3921 South US Highway 1 Fort Pierce, FL 34982 ; ` Account Number; Authorized _U SHOP 6035 3225 4167 1073 00018 Qty Y Item rioti6 it cost Amount j `' 4Job ID; GRINDER BLADE SHOP -'TOTAL 0.00