HomeMy WebLinkAboutDrawing �ECEI''�D �E� 2 3 X5116
FILE COPY
1
51" X 80"
REPLACE DOOR&SIDELIGHT IN 1 OPENING ONLY.
LESS THAN 25%OF TOTAL GLAZED AREA TO BE REPLACED
UNDER THIS PERMIT.SHUTTERS NOT REQUIRED PER FBC,5TH
EDITION(2014), EXISTING BUILDINGS,706.4,EXCEPTION#2.
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 51 80 28.33 4 35.5 -38.7 FL13541.6 50.0 1 -55.0 FRONT ENTRY
U-FACTOR S.H.G.0
DOOR 0.24 0.15
SIDELIGHT 0.24 0.13
REPLACE EXISTING DOOR&SIDELIGHT AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOOR&SIDELIGHT.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR&SIDELIGHT FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 12 FT 2 IN
LUSTER RESIDENCE
4705 PALMETTO DRIVE DOOR REPLACEMENT PLAN
FORT PIERCE, FLORIDA