HomeMy WebLinkAboutEngineering PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772)785 -9888 Email pwelchinc@aol.com February 11,2016 Re: Jones Re-Roof 10725 S. Ocean Drive Unit 136 Jensen Beach, FL 34957 SCOPE OF WORK: Remove existing roofing and install new 5-V Crimp Metal Roof(Gulf Coast Supply& Manufacturing FL# 11651.13)at above referenced residence address over new underlayment and existing plywood sheathing. DESIGN CRITERIA: FBC 2014 ASCE7-10 PROJECT DATA: BUILDING HIEGHT= 9'-0" A=3' MEAN ROOF HIEGHT=<15' ROOF ANGLE=2:12 SHAPE=PITCHED GABLE 1MPROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 165 MPH WIND VELOCITY V asd= 124 MPH EXPOSURE=D ENCLOSURE CLASS=ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (usf): ZONE 1 (Field)=-44.7 ZONE 2(Perimeter/Ridge)_-75.5 ZONE 3 (Corners)_=-110.8 f ` y' f'Paul Welch Inc. Weleh�.. Reg.No.29945 ' e �j 127 2016 ttM1 a r y. 10725 S.Ocean Drive Unit 136 Jensen Beach,FL 34957 �', ��'/,` � 1 of 3 ATTACHMENT REOUIREMENTS: Metal roofing to be attached with#9- 15 x 1 Y2"long(minimum V4"penetration through plywood sheathing)Woodgrip screws with weather sealing washers spacing as follows: ALL FASTENERS IN THE FLAT OF THE PANEL ZONE I (Field): Fasteners adjacent to ribs one side(Type 1 per product approval) at 16" O.C. ZONE 2(Perimeter/Ridge): Fasteners adjacent to ribs one side(Type 1 per product approval) at 16" O.C. ZONE 3(Corners): Fasteners adjacent to ribs both side(Type 2 per product approval) at 16" O.C. Zones 1 &2 Design uplift Pressure: -94.25 psf Zone 3 Design uplift Pressure: - 131.0 psf Zones 1 &2: 94.25 >75.5>44.7 ' Therefore O.K. Zone 3: 131.0> 110.8 Therefore O.K. NOTE: CONTINUOUS APPROVED LAP SEALANT MUST BE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:12. UNDERLAYMENT (oution#1): Underlayment shall be Polyglass USA, Inc. FL#5259.1 "Polystick TU Plus". Polystick TU Plus shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Section 1507. All seal-lap seams must be firmly rolled with a minimum 281b.hand roller to ensure full contact and adhesion. DECK INSTALLATION: Re-nail all plywood sheathing(15/32"thick minimum)with 8D ring-shank nails at 4"O.C. perimeter and 6"O.C. field for all zones. All work to be in compliance with product approval (FL# 11651.13), (FL#5259.1), manufacturer's specifications, and the Florida Building Code 2014. G� rV�`� �w'f�P,aul Welch Inc. t�"Paul Welch'P E ;Reg.No.29945 .L February 12,2016 10725 S.Ocean Drive Unit 136 Jensen Beach,FL 34957 2 of r `-, { ' OA ROOF ZONE PLAN A=3' Q(1), =ZONE DESIGNATION(TYPICAL) NOTE: CONTINUOUS APPROVED LAP SEALANTMUST BE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:-12:4;`' ;,;;•,`r`� '',.' r � i Yd U r� Paul Welch Inc. P,aiilsWelch P.E.Reg.No. 29945 February 12,2016 10725 S.Ocean Drive Unit 136 Jensen Beach,FL 34957 ' , : 3 of 3 MOT 17 � f 'S M ulfCoa�ft sr: ,�^�'�'"'"rv''"' P i Y & t 9 A fd U F A C T U R!IV G 5VCRIMP '26 GA. 5VCRI;MP ROOF PANEL OVER 15/32" PLYWOOD* FLORIDA PRODUCT APPROVAL NO. 11651.13 r TYPE 1 FASTENER PATTERN (1) #9-15 x 1 -1 /2" HWH w/Sealing Washer 12" -12" 1► At Panel Lap TYPE 2 FASTENER PATTERN (1) #9-15 x 1 -1/2" HWH w/Sealing Washer Vill2119.511 -- l' 9.511 2" 1 '�titit1,,,ltrrrr r a, r No. 75519 STATE OF SS's • 0R1D/OAIP .. '�� ,,• 0.63 LIS FL#11651.13 R2•JUNE 15,2015 .s."',.i.�. KUHN ENGINEERING s!