HomeMy WebLinkAboutProduct Approval "Florida Building Code Online Page 1 of 2
fit.,
kf
Edda Depaltmentof BCIS Home Log In I User Registration i Hot Topics'j Submit Surcharge ; Stats&Facts Publications { FBC Staff t BCIS Site Map { Dnks ! Search I
Busines ( RUSER:Professi nal ` Product Approval
Public User
Regulation RCS fes:
Product Approval Menu>Product or Application Search>Application Lis >Application Detail
FL# FL17679-RS FEB 2 4 2016
e.ar-
Application Type Revision PE P,fAITfiRC
Code Version 2014 St. Lucie COUrit'/ ,-I
Application Status Approved
Comments
Archived ❑
Product Manufacturer Drexel Metals,Inc.
Address/Phone/Email 204 Railroad Drive
Ivyland,PA 18974
(502)303-1511
js hu mate@ dre xmet.cam
Authorized Signature Jason Shumate
jshumate@drexmet.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
G7 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity Architectural Testing,Inc.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
J Validation Checklist-Hardcopy Received
Certificate of Independence FL17679 R1 COI 2014 FBC Evaluation Report DRX15002.1 HVHZ-
FINAL.pdf
Referenced Standard and Year(of Standard) Standard Year
TAS 100 1995
TAs 110 2000
TAS 125 2003
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvFGYZsj rZFR... 2/10/2016
'Florida Building Code Online Page 2 of 2
e
Product Approval Method Method 1 Option D
Date Submitted 08/13/2015
Date Validated 08/13/2015
Date Pending FBC Approval 08/17/2015
Date Approved 10/16/2015
Summary of Products
FL# Model,Number or Name Description
17679.1 Drexel Metal Roofing Systems DMC 100NS,DMC 150SS,DMC 175S,DMC 200S,DMC SV
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL17679 R1 11 2014 FBC Evaluation Report DRX15002.1
Approved for use outside HVHZ: No HVHZ- FINAL.Ddf
Impact Resistant:N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: +0/-180 Created by Independent Third Party:Yes
Other:See evaluation report for limits of use Evaluation Reports
FL17679 R1 AE 2014 FBC Evaluation Report DRX15002.1
HVHZ- FINAL.pdf
Created by Independent Third Party:Yes
Back Next
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do•not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
�z M eCfz`ch M
Securitym LTIklu
http://www.floridabuilding.org/pr/prapp dtl.aspx?param=wGEVXQwtDgvFGYZsjrZFR... 2/10/2016
Certificate of Authorization No. 29824
C RE` E"K 17520 Edinburgh Dr
Tampa,FL 33647
TECHNICAL, SERVICES, LL (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE ST"EDITION(2014)
Manufacturer. DREXEL METALS, INC. Issued August 12, 2015
1234 Gardiner Lane
Louisville, KY 40213
(502)716-7143
www.drexmet.com
Manufacturing: Drexel Metals Association.of Regional Manufacturers(DM-ARM)
Quality Assurance: Architectural Testing, Inc. (QUA1844)
SCOPE
Category: Roofing
Subcategory: Metal Roofing
Code Sections: 1518.9.1, 1523.1.1, 1523.6.5, 1523.6.5.2.4, 1523.6.5.2.4.1
Properties: Wind Resistance
REFERENCES
Ent! Report No. Standard Year
Architectural Testing(TST1558) 56840.02-122-18 TAS 100 1995
Architectural Testing(TST1558) 56842.02-122-18 TAS 100 1995
Architectural Testing(TST1558) 58461.01-122-44 TAS 125 2003
Architectural Testing(TST1558) 58641.02-122-44 TAS 100 1995
Hurricane Test Laboratory(TST1527) 0287-0209-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0308-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0311-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0312=07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0313-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0512-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0706-07 TAS 125 2003
PRI Construction Materials Technologies(TST5878) AKZC-001-02-01/05 ASTM-13 117 2002
PRI Construction Materials Technologies(TST5878) AKZC-001-02-01/05 TAS 110 2000
PRI Construction Materials Technologies(TST5878) AKZC-003-02-01/02 ASTM B 117 2002
PRI Construction Materials Technologies(TST5878) AKZC-003-02-01/02 TAS 110 2000
PRI Construction Materials Technologies(TST5878) AKZC-003-02-03/04 ASTM G 26 1996
PRI Construction Materials Technologies(TST5878) AKZC-003-02-03/04 TAS 110 2000
PRI Construction Materials Technologies(TST5878) DMC-002-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-004-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-005-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-006-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-007-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-008-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-009-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMG014-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMG016-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-030-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) HTL-013-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) HTL-014-02-01 TAS 100 1995
DRX15002.1 FL17679-R1 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not
specifically addressed herein.
DREXEL METALS„INC.
CREEKMetal Roofing(HVHZ)
-TECHNICAL SERVICES,LLC
PRODUCT DESCRIPTION
DMC 100NS Profile; 1 1 in.snap lock seam;Ma_x.16 in.coverage
Description: I Non-structural,snap lock standing seam roof panel with integral perorated nail
i strip
Material: ' Min.24 ga.TRINAR@ or CERAM-A-STARO coated ASTM A792 AZ50,or
ASTM A653 G90;FY min-50 ksi; Shall conform with FBC Section 1507.4.3
I
t
t
i
DMC 15OSS Profile; 1.5 in.mechanical seam;Max. 16 in.coverage
Description: Non-structural,mechanical lock standing seam roof panel
Material:ial f Min.0.032 in.TRINAR®or CERAM-A-STAR@ coated ASTM 8209 aluminum; FY=
i rein. 16 ksi; Shall conform with FBC Section 1507.4.3_ _
Min,24 ga.TRINAR@ or-CERAM-A-STAR@ coated ASTM A792 AZ50,or
ASTM A653 G90;FX=min.50 ksi; Shall conform with FBC Section 1507:4.3
i 1u 3n
'! 2 6
8
_L
1 ' 19'
1 �_T
16" —,
i
DMC 175S I Profile: _ 1.75 in.snap lock seam; Max. 18 in.coverage.
Description: Non-structural,snap lock standing seam roof panel
Material: i Min.0.040-inch TRINARO or CERAM-A-STARO coated ASTM B209 aluminum(Fy
=_min.20.ksi); Shall conform with FBC Section 1507.4.3_
Min.24 ga.TRINAR®or CERAM-A-STARO coated ASTM A792 AZ50,or
ASTM A653 G90ASTM A792 or ASTM A653;FY-=min.50 ksi; Shall'conform with
FBC Section 1507.4.3
1 li3n
! i
1 S"
DRX15002.1 FL17679-R1 Page 2 of 4
This evaluation report is.provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not
specifically addressed herein.
MCREEKDREXEL METALS,INC.
Metal Roofing(HVHZ)
0 REGI=LAICAL SERVIC;Es,LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 5'"Edition(2014)as evidenced in the referenced documents submitted by the named manufacturer.
`,,��t�i►t a►►t►°°i
�\GENSR'•p'�'�°'- 2015.08.12
Q-..• *•. cS� �.
'1i. .. >,
10
17:29:46
No 740.21
-04'00'
'. STATE OF 4U
O;J% p R`p P- � Zachary R. Priest, P.E.
�NA�� ��`, Organization NoFlorida !ANEon g6 4021
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest,P.E. does not have,,nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
APPENDICES
1) APPENDIX A—Installation(8 pages)
2) APPENDIX B—Approved Roof Systems(5 pages)
3) APPENDIX C—Design Wind Loads(3 pages)
DRX15002.1 FL17679-R1 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61-G20-3. The manufacturer shall notify CREEK
Technical.Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
DREXEL METALS,INC.
CREEKMetal Roofing(HVHZ)
TECHNICAL SERVICES, LLC
Component Product; Installation Detail
22 ga.SS in-seam clip
28�
DMC 200S Clip 1„ T1 Q
0
o
0
/ 3'
Y
18 ga.base;22 ga.butterfly in-seam clip;4.5 in.length
DMC 200S Butterfly Clip
e�2
18 ga.base;22 ga.butterfly in-seam clip;120 in.length;top slider 12 in.o.c.
DMC 200S Continuous
Butterfly Clip i
Sealants Bostik 70-05A Shall be applied in continuous beads along the seam
Sostik Chem-Calk 915
Fastenin 'Details
Nomenclature Attachment
DMC 100NS Standard
DRX15002.1 FL17679-R1 Page 3 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not
specifically addressed herein.
DREXEL,METALS,INC.
CREEKMetal Roofing(HVHZ)
TECHNICAL SERVICES,LLC
Fastenin Details
Nomendature Attachment'
BOSTIK..7sgQ.-gg(05 (2 - 3h 6" BEADS)
13 -
DMC 100NS Enhanced
DMC 150SS PANEL--------\
DMC 1508S CONTINUOUS BUTTERFLY CLIP--------\�`
(2)#10-13 PHW-
UNDERLAYMENT
DMC 15OSS Continuous SUBSTRATE
Butterfly
Y
DMC 15OSS PANEL
DMC 150SS BUTTERFLY CLIP
(2)#10-13 PHW
UNDERLAYMENT
DMC 15OSS Butterfly SUBSTRATE
_r—
DMC 15OSS PANEL
24 GA DMC 15OSS FIXED CLIP
(2).#10-13 PHW
UNDERLAYMENT
DMC 15OSS Fixed-90 SUBSTRATErr
}
r
DRX15002.1 FL17679-R1 Page 4 of 8
This evaluation report is_provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that a re not
specifically addressed herein.
DREXEL METALS,INC.
CREEKMetal Rooting(HVHZ)
TrCHNICAL SERv10F_S, LLC
Appendix B
APPROVED ROOF SYSTEMS
The following notes shall be observed when using the assembly tables below.
1. Maximum Design.Pressures(MDP)were calculated using a 2:1 margin of safety per FBC Section 1523.4.
2. Refer to LIMITATIONS and sections of this evaluation when using the fable(s)below.
3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly.
4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated system.
5. Undedayment shall be installed in accordance with FBC:requirements. The minimum underlayment shall be ASTM D 226,Type II installed as described
in RAS 115 Section 4:
6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga(Fy=min.33 ksi)Wide Rib Deck(Type WR)
conforming to ANSUSDI-RD1.0&FBC. In no caseshall the panels be installed on less than two continuous.spans,which are spaced a maximum 5-ft o.c.
At minimum,the deck shall'be attached with one(1)#12 x 1.5-inch HWH self-drilling screws at the bottom of each flute(maximum.6-inch o.c.along the
support). At minimum,the deck side laps shall be fastened a maximum 6-inch o.c:with#12 x 1.5-inch HWH self-drilling screws.
7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum. 1.9132-inch thick APA Span-Rated plywood
Sheathing or wood plank at maximum 24-inch span for new construction. Existing construction shall be the minimum plywood sheathing or wood plank
thickness at maximum 24-inch span as stated in the approval tables on following pages. In no case shall the attachment'be less than 8d ring shank nails
spaced 6-inch o.c.
Roof,S stem Mum6ers anc!Qeflnitions:
100NS-W4 DMC 100NS over Wood Deck New or Existing)
15QS&W# DMC 150SS over Wood Deck New on Existing)
175S-S# DMC 175S over Steel Deck New or Existing)
175S-W#- DMC 175S over Wood Deck new or Existing)
ZQQ-S--S# DMC 200S over Steel Deck(New or Existing)
2005-W# DMC 200S over Wood Deck New or Existing)
5N---W-# I DMC 5V over Wood Deck New or Existing)
DRX15002.1 FL17679-R1 Page 1 of 5
This evaluation report is provided for State of Florida product approval under Rule 61620-3. The manufacturer shall notify CREEK Technical Services;LLC of any product changes or
quality assurance changes throughout the duration.for whichthis report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other
product attributes that are not specifically addressed herein.
DREXEL METALS,INC.
MCREEKMetal Roofing(HVHZ)
TI=CHNICAL SERVICES, LLC
Appendix C
"'. Gable/Hi "Roofs'in•Exposu'ke C in Miami=Dade&Broward County Roof.slo es Between 2:12_and 6.9;92 `: . .
Basic Wind S eed m h
Buildin T e Zone Mean Roof; Risk Cat l Risk Cat I 'Risk Cat II : -:Risk Cat ttc Risk Cat III,IV„ Risk Cat 111,IV,
9 yP Height{ft)w
;165. 170 175
20 -30.9 =34.6 -36.7 -38.9 -41.1 -43.9
25 -32.3 -36.1 -38.3 -46.6 -42.9 -45.9
1 30 -33.6 -37.6 -39.9 -42.3 44.8 -47.8
40 -35.7 -39.9 -42.4 -44.9 -47.5 -50.7
50 -37.4 -41.8 -44.4 -47.1 -49.8 -53.2
60 -38.8 -43.4 -46.1 -48.8 -51.6 -55.1
20 -53.8 -60.1 -63.8 -67.7 -71.6 -76.4
25 -56.2 -62.8 -66.7 -70.7 -74.8 -79.8
Enclosed 2 30 -58.5 -65.5 -69.5 -73.7 -77.9 -83.2
40 -62.1 -69.5 -73.8 -78.2 -82.7 -88.3
50 -65.1 -72.8 -77.3 -81.9 -86.7 -92.6
60 -67.5 -75.5 -80.2 -84.9 -89.9 -96.0
20 -79.5 -88.9 -94.4 -100.0 -105.8 -113.0
25 -83.0 -92.9 -98.6 -104.5 -110.5 -118.0
3 30 -86.6 -96.8 -102.8 -108.9 -115.3 -123.1
40 -91.9 -102.8 -109.1 -115.6 -122.3 -130.6
50 -96.3 -107.7 -114.3 -121.2 -128.2 -136.9
60 -99.8 -111.7 -118.5 -125.6 -132.9 -141.9
20 -41.6 -46.4 -49.2 -52.2 -55.2 -58.9
25 -43.3 -48.5 -51.4 -54.5 -57.7 -61.6
1 30 -45.2 -50.5 -53.6 -56.8 -60.1 -64.2
40 -47.9 -53.6 -56.9 -60.3 -63.8 -68.1
50 -56.2 -56.2 -59.6 -632 -66.9 -71.4
60 -52.1 -58.2 -61.8 -65.5 -69.3 -74.0
20 -64.3 -72.0 -76.4 -81.0 -85.7 -91.5
25 -67.2 -75.2 -79.8 -84.6 -89.5 -95.5
Partially 30 -70.1 -78.4 -83.2 -88.2 -93.3 -99.6
Enclosed 2 40 -74.4 -83.2 -88.3 -93.6 -99.0 -105.7
50 -77.9 -87.2 -92.5 -98.1 -103.8 -110.8
60 -80.8 -90.4 -95.9 -101.7 -107.6 -114.8
20 -90.1 -100.8 -107.0 -113.4 -119.9 -128.1
25 -94.1 -105.3 -111.7 -118.4 -125.3 -133.8
3 30 -98.1 -109.7 -116.5 -123.4 -130.6 -139.4
40 -1.04,1 -116.5 -123.6 -131.0 -138.6 -148.0
50 -109.1 -122.1 -129.6 -137.3 -145.2 -155.1
60 -113,1 -126.5 -134.3 -142.3 -150.6 -160.8
DRX15002.1 FL17679-R1 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other
product attributes that are not specifically addressed herein.
DREXEL METALSJNC,
OCREEKMetal Roofing(HVHZ)
TECHNICAL SERVICES, LLC
Appendix C
Gable/Hi Roofs in Ex osure D in Miami-Dade 8 Bioward Coun Roof'slo es between 2:12:and 6:1:12 -
Mean Roof Basic Wind SPeed m h
Bwlding Type ,; Zone Risk Cat I Risk.Cat I Risk Cat II ;; Risk Cat LI ;Risk Cat III IU Risk Cat tlI IU
Height(ft)
156 -165 170 175 R' ;180 186
20 -37.1 -41:5 -44.0 -46.6 -49.3 -52.7
25 -38.4 -43.0 -45.6 -48.4 -51.2 -54.6
1 30 -39.8 -44.5 47.3 -50.1 -53.0 -56.6
40 -41.9 -46.8 -49.7 -52.7 -55.7 -59.5
50 -43.6 -48.8 -51.8 -54.8 -58.0 -62.0
60 45.0 -50.3 -53.4 -56.6 -59.9 -63.9
20 -64.5 -72.2 -76.6 -B1.:2 -85.9 -91.7
25 -66.9 -74.8 -79.5 -84:2 -89.1 -95.1
Enclosed 2 30 -69.3 -77.5 -82.3 -87.2 -92.3 -98.5
40 -72.9 -81.5 -86.5 -91.7 -97.0 -103.6
50 -75.9 -84.9 -90.1 -95.5 -101.0 -107.8
60 -78.3 -87.5 -92.9 -98.5 -104.2 -111.2
20 -95.4 -106.7 -113.3 -120:1 -127.0 -135.6
25 -98.9 -110.7 -117.5 -124.5 -131.7 -140.6
3 30 -102,5 -114.6 -121.7 -128.9 -136.4 -145.7
40 -107.8 -120.6 -128.0 -135.6 -143.5 -153.2
50 -112.2 -125.5 -133.2 -141:2 -149.4 -159.5
60 -115.7 -129:5 -137.4 -145.6 -154.1 -164:5
20 -49.8 -55.7 -59.1 -62.6 -66.3 -70.7
25 -51.6 -57.7 -61.3 -64.9 -68.7 -73.4
1 30 -53.4 -59.8 -63.5 -67.3 -71.2 -76.0
40 -56.2 -62.9 -66.8 -70.7 -74.8 -79.9
50 -58.5 -65.5 -69:5 -73.6 -77.9 -83.2
60 -60.4 -67.5 -71.7 -76.0 -80.4 -85.8
20 47.2 -86.4 -91.7 -97:2 -102.8 =109.8
25 -80.1 -89.6 -95.1 -100.8 -106.6 -113.8
Partially 30 -82.9 -92.8 -98.5 -104.4 -110.4 -117.9
Enclosed 2 40 -87.2 -97.6 -103.6 -109.8 -116.1 -124.0
50 -90.8 -101.6 -107.8 -114.3 -120.9 -129.1
60 -93.7 -104.8 -111.2 -117:9 -124.7 -133.1
20 -108.1 -120.9 -128.4 -136.0 -143.9 -153.7
25 -112.1 -125.4 -133.1 -141.1 -149.2 -159.4
3 30 -116.1 -129.9 -137.9 -146.1 -154.6 -165.1
40 -122.1 -136.6 -145.0 -153.7 -162.6 -173.6
50 -127,1 -142.2 -151.0 -160.0 -169.2 -180.7
60 -131.1 -146.7 -155.7 -165.0 -174.6 -186.4
DRX15002.1 FL17679-R1 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this.report is valid, This evaluation report does not express nor imply warranty, installation,recommended use,or other
product attributes that are not specifically addressed herein.
Florida Building Code Online Page 1 of 2
FlWa DeparnEntof BCIS Home i Log In 1 User Registration u Hot Topics q Submit Surcharge Stats&Facts i Publications { FBC Staff 1 BCI5 Site Map j Links Search i
l t9 i"
Busines l/ -� � l•�. ��
Professi i nal 3- USER:Publics User
Product roval
Regulation FEB ? 4 2016
Product Approval Menu>Product or Application Search>Application Lis[>Application Detail
PER MF T1ING
FL# FL16906-R1 St. Lucie County, FL
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived Ej
Product Manufacturer TRI-BUILT Roofing Products
Address/Phone/Email 9050 Louisiana Street
Merrillville,IN 46410
(201)842-2449
david.ruiz@tribuiltmater'iaisgroup.com
Authorized Signature David Ruiz
david.ruiz@tribuiltmaterlaisgroup.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
W Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
W Validation Checklist-Hardcopy Received
Certificate of Independence FL16906 R1 COI TBIJ 14001.1 2014 FPA TRI-BUILT Self Adhering HT
Underlavment- FINAL.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D 1970 2009
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
http://www.floridabuilding.oriz/nr/pr� app dti.aspx?param=wGEVXQwtDgvBwYu9TrZN... 2/23/2016
ti Florida Building Code Online Page 2 of 2
Date Submitted 04/19/2015
Date Validated 04/20/2015
Date Pending FBC Approval 04/22/2015
Date Approved 06/22/2015
Summary of Products
FL# Model,Number or Name Description
16906.1 TRI-BUILT Self Adhering HT ASTM D 1970 underlayment
Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16906 RI II TBM14001.1 2014 FPA TRI-BUILT Self
Approved for use outside HVHZ:Yes Adhering HT Underlayment-FINAL.pdf
Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL16906 R1 AE TBM14001.1 2014 FPA TRI-BUILT Self
Adhering HT Underlayment-FINAL.pdF
Created by Independent Third Party:Yes
Back Next
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Conyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
E0 ® ECt.eck M
SCCIITICV:•i i(3'{ilt.Y
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvBwYu9TrZN... 2/23/2016
4
Certificate of Authorization No. 29824
17520 Edinburgh DriveCREEK
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT 2014 FLORIDA BUILDING CODE
Manufacturer: TRI-BUILT Materials Group Issued Apri115, 2015
9050 Louisiana Street
Merrillville, IN 46410
(800)516-1485
www.tri bui ltmaterialsciroup.com
Manufacturing Location: Petrolia, Ontario, Canada
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5.1, 1507.4.5.2, 1507.5.3, 1507.5.3.2,
1507.7.3, 1507.7.3.2, 1507.8.8, 1507.9.9
Properties: Physical properties
REFERENCES
Enti Report No. Standard Year
PRI Construction Materials Technologies(TST6049) HGC-140-02-01 ASTM D 1970 2009
PRODUCT DESCRIPTION AND APPLICATION
TRI-BUILT Self TRI-BUILT Self Adhering HT Underlayment is a self-adhered, ASTM D 1970
Adhering HT underlayment reinforced with a polyethylene film surface for use on steep slope roofs.
Underlayment
Roof Deck: The roof deck shall be constructed of closely fitted
plywood sheathing for new or existing construction.
Plywood deck shall be installed in accordance with
FBC requirements. Roof decks shall have no more
than 1/8"gap at abutting joints.
Min.slope: In accordance with FBC requirements
Attachment method: The underlayment shall be attached by adhering
directly to the roof deck with minimum 2.75" side
laps and minimum 2.75" end laps. All side laps
seams shall be installed to shed water from the
deck Priming of the roof deck shall be optional.
Min.application temperature: 40°F. Contact the manufacturer when installing at
temperatures below 40°F.
Allowable roof coverings: Roof coverings shall be mechanically fastened
through to the roof deck. Attachment of asphalt
shingles, wood shakes and shingles, slate
shingles, metal roof panels and shingles shall be
permitted.
TBM14001.1 FL16906-R1 Page 1 of 2
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
v
CREEK TRI-BUILT MATERIALS GROUP
TRI-BUILT Self Adhering HT Underlayment
TECHNICAL SERVICES, LLC
LIMITATIONS
1) This evaluation report is not for use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) The underlayment may be used as described in other current FBC product approval documents.
7) Roof coverings shall not be adhered directly to the underlayment.
8) The underlayment shall not be installed over existing roof coverings.
9) The underlayment shall be exposed on the roof deck for a maximum duration of 30 days.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida
Building Code as evidenced in the referenced documents submitted by the named manufacturer.
,N.�GxPaY R. '0�,� 2015.04.1
...
. G E NSF.
No 74021 - 5 09.46.12
* = -04'00'
-P% STATE OF .'41J
:�0 ,c N,4/� Zachary R. Priest, P.E.
O R O P , Florida Registration No.74021
#11,;ONA Organization No.ANE9641
4111
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBM14001.1 FL16906-R1 Page 2 of 2
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.