HomeMy WebLinkAboutEngineering Florida Building Code Online Page 1 of 2
Ronda DepaMentuf SCIS Home Log In User Registration ! Hot Topics Submit Surcharge f Stats&Facts Publications j FBC Staff f BCIS Site Map I Links Search
Busines
Drofessi (PUSER:Publics Upseroval,��al
Regulation
n Product Approval Menu>Product or Application Search>Aoplication List>Application Detail VLam.�s
• FL* FL10674-RII FEB ' 4 2016
Application Type Revision &.
Code Version 2014 PERMIT 1KIG
Application Status Approved 5t. Lucie County, FL
Comments
Archived ❑
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscomig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
LI Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017
Validated By John W. Knezevich,PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL10674 R11 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwLDgtBNbEY5 V%2... 2/23/2016
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 10/15/2015
Date Validated 10/19/2015
Date Pending FBC Approval 10/20/2015
Date Approved 12/15/2015
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Coming Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10674 R11 II 2015 10 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-Rll.odf
Impact Resistant:N/A Verified By: Robert J. M. Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section 5. Evaluation Reports
FL10674 R11 AE 2015 10 FINAL ER OC ASPHALT
SHINGLES FL10674-Rll.odf
Created by Independent Third Party:Yes
Back Next
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
Em® e0t_c
SCCUlIty{t is{T[I C:r
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2... 2/23/2016
EXTERIOR RESEARCH& DESIGN,.LLC.
r.)(D. Certificate of Authorization#9503
T 1N' ER® 353 CHRISTIAN
OXFORD,�CT 06478
PHONE:(203)262.9245
FAX:(203)262-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R6
One Owens Corning Parkway FL10674-R11
Toledo,OH-43659 Date of Issuance:02/06/2012
Revision 6: 10/15/2015
SCOPE:
This Evaluation Report is issued under Rule. 61G20-3 and the applicable rules and. regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt.Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that.relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to.notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation. Report number preceded by the words "TrinityJERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at thejob site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by: ,�t,t,r,r"I —
y .k
w'
Robert J.M.Nieminen,P.E. Eeon10/15/2015.Thfacsimile seal is does not servring was e asaneectronized by Robert calyssigned
Florida Registration No.59166,Florida DCA ANE1983 `j-Jlri"jj°" document.Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named crient
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing-products it evaluates.
2. TrinityJERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity_IERD nor Robert Nieminen,P.E.are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
Q0TRINITY'ItRD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category; Asphalt Shingles
Compliance Statement: Owens Corning Asphalt.Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code,Residential Volume
through testing in accordance with the following.Standards. Compliance is subject to theInstallation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM.D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
gniitt Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
ULLLC.(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire®are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshirelm are fiberglass reinforced,5-tab asphalt roof shingles.
4:1.4 Duration, TruDefinition Duration, Duration Premium. Cool, Tru Definition Duration® Designer Color
Collection,TruDefinition®Oakridge,Oakridge®and WeatherGuard HP are fiberglass reinforced,laminated
asphalt roof shingles.
4.2 Berkshire' Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard* HP Hip & Ridge
Shingles,ProEdge Hip&Ridge Shingles and DuraRidgeTm Hip&Ridge Shingles are fiberglass reinforced,hip
and ridge asphaltroof shingles.
4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll-are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, of previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6
Certificate of Authorization#9503 FL10674-Rll
Revision 6:10/15/2015
Page 2 of 7
T+ IteII1V ESD
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for
us in all wind zones up to Vasd=150 mph(V„h= 194 mph.). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and, Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for us in all wind zones up to Va,d= 150 mph (Vuit= 194 mph). Refer to Section 6
for installation requirements to meetthis wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for.conditions outside these limitations.
Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation Limitations.
5.5 All products.in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,.1507.2.4 or 11905.2.3.
6.2 Asphalt.Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four(4) nails per shingle in accordance with FBC Sections 1507.2 or 11905.2, with the following
exceptions:
➢ Berkshiree shingles require minimum five(5)nails per shingle.
WeatherGuard®HP shingles require minimum six(6)nails per shingle.
➢ Devonshire'"shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip.Plus:
Felt underlayment Deck Fek undeillayment Deck Self-adhered
_ WeatherLockV
L Self-adhered underloyment
%NeatherLocke
uhdedayment
Drip DripDrip edge
edge edge ed 9e
Nails located NaAs located
2'-4'from eave
2"-3"from eave
Install first Self-sealing adhesive Self-sealing adhesive
StarterSt�rip positioieWeingeave Imta�grstStaRerStripPlus positioned along eave
shingle wdh \ vaith 6'removed
6"removed
Starter Strip shingle overhangs eaves and rakes IWY/47 6tartar Strip Plus overhangs eaves and rakes 1/4'-3/4°
Exterior Research and Design,U.C. Evaluation Report 037940.02:12-R6
Certificate of Authorization/19503 FL10674-R11
Revision 6:10/15/2015
Page 3 of 7
TIRIN1Y JtRD
6.2.6 Minimum Nailing—Classic®&Supreme:
Normal' Mansard or Area para Normal Mansard or Area para•
Wind Areas High Nllnd desvanesy -Wind Areas High Wind desvenes y
Area pare'vlentos norntaies Areas' viontoa Mertes. Area para.vientos normales Areas vientos pertes
"° tAl:. »°tn `t. 2�. IB 2° r tti 12 t �� l61 rx.,
. . . ...
W.'Exposure 551V'Exposure
Exposicion Exposiei6n'
6.2.7 Minimum:Nailing—Berkshire°:
SealariCstrip Sealant strip.
is!"de sdi dpf La Ura de seiladoi
B Vf' 9
I
9 Yi" D
"R.YC gyp S Vi' B Vf t
L
] V
r
r
2" Asphatt'rooriinocement
Cemento da tzcbodeasfatfo
6.2.8 Minimum Nailingl—DevonshireTM':
Nails
r Tc x e• r r i' r a r II
Nails Ten 1".Spots of Asphalt Roof Cement
Exterior Research and Design,LLC. Evaluation Report 037440:02:12-R6
Certiflcate of Authorization#9503 F L10674-R11
Revision 6:10/1512015
page 4 of 7
"\J�
TRINITY I ERD
e.
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition
Duration®Designer Color Collection:
rdrtJ4 Nail Pattern 6 Nail �"Ienbstmmsureoop PL�q�
Esquema de 4 clavos Pattern area andtw of eat 01L
Esquema; dl mmb oxzbrefes,
Su_reNaiW:6sten'eig aria vikitti de 6 elavoS- apedasri-rids cme d
At"dedamssureNalle • • • 3reaSuenaa�rbLCate
SunffuY° \ SwtNa1P
- �• -�• tasleriff1I99 � fastenmg
area lYidttl'. `, arealvi¢h
_ ..t2° :'12, 11. _ AnaBe
Sntiala- E— tz' `x. 17,` swt I�
WallEmmuteNails 635"rxposure
51/putg:deexposid6n efavos. SaSputg.degxp'oshidti.
5V Exposure: Balls 599'Exposure
5'hpedg.doerposicidn Clavus FApufg.deuposteldn
a
6.2.10 Minimum Nailing—TruDefinition Oakridge®,Oakridge®:
4 Nail Pattern 6 Nall Pattern:
Eequgma con 4 clavas Esquema coil'6-clavas
r �•
t• t
I<---
12-
515A r'Expmre
2•5618"Exposure Nails 55f8'Exposu2 Naffs:
Expcsfefdade66/8pufg. Glivas Exposkldnde6618pufg.. 5518"Exposure Gtavos 55/8 Exposu2
&poslefdu de 5618 pulg. Exposic 6n de 66/8 prilg
6.2.11 Minimum.Nailing-WeatherGuard®HP:
1'
1-4 Bingle.61de Vlow
Fj�c�- AMn..ft-.*Milli like
� +f�.e1t�
31,
6.3 Hip&Ridge Shingles:
6.3.1 Installation of`Berkshire Hip and Ridge Shingles, High Ridge, Hip&Ridge with Sealant,WeatherGuard HP
Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current
published instructions, using four (4) nails per shingle. Installation of DuraRidgell Hip &Ridge Shingles
shall comply with the manufacturer's current published instructions,using two(2) nails per shingle. Refer
to Owens Corning published information on wind resistance and installation limitations,including the use
of hand-sealing for wind warranties.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RG
Certificate of Authorization#9503 FL10674-R11
Revision 6:10/15/2015
Page 5 of 7
-,PTRINIWIERD
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.1 4' Fig.2
Pieva ling Vltla
-0eeGlon 'A T6mc" SIdeXAM
Nails-- ] A NailsNails
4• 77
�- z• I Tot!_lanan'aled .T �..
4- Piece
9 p �
r
1 I
I 1
fit-8' g- ml
u I'
I
I
I
I
I
I
6.3.4 Minimum Nailing—Hip&Ridge with Sealant:
em Fig--2 AighWndfastenng-Rattelm
14 Nails)
rim Shingle
nd DMisr.,ard �► ,�.
Elf: l6 �r
Sealant --I.
Strip-
Fai'ten t ng,5 5/4o 15"
Exposure
F�cposure
12
6.3.5 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
Fig.0Hip&Ridge Fastening,Shin
Fig:A - 4 4, T4VkW
PDlrectbnranag�tg wino
A
A I Nalls Nails
A- A I I •-
A
I 1
EXP_
ulo
s' E=Pesure
Exterior Research and Design,I.I.C. Evaluation Report 037940:02:12-116
Certificate of Authorization 119503 FL10674-Rll
Revision 6:10/15/2015
Page 6 of 7
TRII ITY�ERD
6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard --11.
Wind DirectionFastening
Sealant Strip Pattern
4—� 6'Exposure
92° i Sealant
Fasten 71h' 7 1h' 6°Exposure
Cover Exposed I I 1
Fasteners with
Roof Cement I�12•
6.3.7 Minimum Nailing—DuraRidgelm Hip&Ridge Shingles:
Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens
Corning published installation instructions for their minimum requirements.
Pracaifng Wird Dirmdm Top View
Diroaion&-Tii=cadn tVue IJ- Visnae plan
1•I�
Diracdtn dal vicnto Arai rnimntn
�- _
__ __ clams.
Naih b 3c • 6rrcrtr Coaiiia�Suml•Jair'., • CA"
s/ar i i I
IVa
�Ia�
IRMA u iH
I
12-
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table:1507.2.7.1/,11905,2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on.which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625 (414)248-6409; karen.buchmann@ul.com
- END OF EVALUATIONREPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.112:12-R6
Certificate of Authorization#9503 F L10674-R11
Revision 6:10/15/2015
Page 7 of 7
Florida Building Code Online Page 1 of 2
z
i
_ 1
Hof&Deparnentof SCIS Home I Log In j User Registration Hot Topics i Submit Surcharge Stats&Facts i Publications I FBC Staff i BCIS Site Map l Unks Search 1
Busines (� �-
Professi nal )Product Approval M
,USER:Public User
Regulation
Product Approval Menu>Product or Application Search>Application Lis[>Application Detail
FEB &. 4 201
FL# FL16906-R1
Application Type Revision PER:4IIT7ITICa
Code Version 2014 St.Lucie County, FL
Application Status Approved
Comments
Archived ❑
Product Manufacturer TRI-BUILT Roofing Products
Address/Phone/Email 9050 Louisiana Street
Merrillville,IN 46410
(201)842-2449
david.ruiz@tribuiltmaterlaisgroup.com
Authorized Signature David Ruiz
david.ruiz@tribuiltmateriaisgroup.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
f r', Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
W Validation Checklist- Hardcopy Received
Certificate of Independence FL16906 R1 COI TBH 14001.1 2014 FPA TRI-BUILT Self Adhering HT
Underlayment-FINAL.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D 1970 2009
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
http://www.floridabuilding.orCE/Dr/pil app dti.aspx?param=wGEVXQwtDgvBwYu9TrZN... 2/23/2016
Florida Building Code Online Page 2 of 2
Date Submitted 04/19/2015
Date Validated 04/20/2015
Date Pending FBC Approval 04/22/2015
Date Approved 06/22/2015
Summary of Products
FL# Model,Number or Name Description
16906.1 TRI-BUILT Self Adhering HT ASTM D 1970 underlayment
Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16906 111 II TBM14001.1 2014 FPA TRI-BUILT Self
Approved for use outside HVHZ:Yes Adhering HT Underlayment-FINAL.pdf
Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL16906 R1 AE TBM14001.1 2014 FPA TRI-BUILT Self
Adhering HT Underlayment-FINAL.pdf
Created by Independent Third Party:Yes
Back Next
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
El R�x EH im
securityM rviuc s
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvBwYu9TrZN... 2/23/2016
Certificate of Authorization No. 29824
CREEK
17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT 2014 FLORIDA BUILDING CODE
Manufacturer: TRI-BUILT Materials Group Issued April 15, 2015
9050 Louisiana Street
Merrillville, IN 46410
(800)516-1485
www.tribuiltmateriaisgroup.com
Manufacturing Location: Petrolia, Ontario, Canada
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5.1, 1507.4.5.2, 1507.5.3, 1507.5.3.2,
1507.7.3, 1507.7.3.2, 1507.8.8, 1507.9.9
Properties: Physical properties
REFERENCES
EniL Report No. Standard Year
PRI Construction Materials Technologies(TST6049) HGC-140-02-01 ASTM D 1970 2009
PRODUCT DESCRIPTION AND APPLICATION
TRI-BUILT Self TRI-BUILT Self Adhering HT Underlayment is a self-adhered,ASTM D 1970
Adhering HT underlayment reinforced with a polyethylene film surface for use on steep slope roofs.
Underlayment
Roof Deck: The roof deck shall be constructed of closely fitted
plywood sheathing for new or existing construction.
Plywood deck shall be installed in accordance with
FBC requirements. Roof decks shall have no more
than 1/8"gap at abutting joints.
Min.slope: In accordance with FBC requirements
Attachment method: The underlayment shall be attached by adhering
directly to the roof deck with minimum 2.75" side
laps and minimum 2.75" end laps. All side laps
seams shall be installed to shed water from the
deck. Priming of the roof deck shall be optional.
Min. application temperature: 40°F. Contact the manufacturer when installing at
temperatures below 40°F.
Allowable roof coverings: Roof coverings shall be mechanically fastened
through to the roof deck. Attachment of asphalt
shingles, wood shakes and shingles, slate
shingles, metal roof panels and shingles shall be
permitted.
TBM14001.1 FL16906-R1 Page 1 of 2
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.