HomeMy WebLinkAboutProduct Approval From: EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 QTRINITYIERD 353 CHRISTIAN STREET,UNIT#13 OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R6 One Owens Corning Parkway FL10674-R11 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 6: 10/15/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: ,.,,��tttt,►;,,.,, y 'tiLy+•• i+• 'p�UJ- �i�E+'••.- �5•*: The facsimile seal appearing was authorized by Robert Nleminen, Robertl.M.Nieminen,P.E. ,s :;,. SIQ,Vitaa�aa P.E.on]0/15/1075.This does not serve as an electronically signed Florida Registration No.59166,Florida DC4 ANE1983 ;,"• document.Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4• Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. From �'�PiRRiNury- I-EK ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Proper Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R90S.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL.LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) F8C HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshireo are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire`'are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration', TruDefinition' Durationm, Duration® Premium Cool, TruDefinitiong Duration® Designer Color Collection,TruDefinitions0akridge',Oakridge and WeatherGuardo HP are fiberglass reinforced,laminated asphalt roof shingles. 4.2 Berkshires Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard' HP Hip & Ridge Shingles,ProEdge Hip&Ridge Shingles and DuraRidgel Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. . Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6 Certgltate o/Authar&ation#9303 FL10674-R11 Revision 6:10/15/2015 Page 2 of 7 From., Uz/�4r�u�o va:ca fscoo r.vv�.v r�. I _ 1 m` I til I YD EKD 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for. us in all wind zones up to Va:d=150 mph(V,,lt=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph(V„It=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 611320-3,per FBC Sections 1507.2.3,1507.2.4 or 11905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire*shingles require minimum five(5)nails per shingle. ➢ WeatherGuard HP shingles require minimum six(6)nails per shingle. Y Devonshire'shingles require minimum six(6)nails per shingle. Y Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope'exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Fell undedayment Deck Feltundabyment •r. Deck Sell-edherad •-� vVeatherLodrY !. SeH•adhered undedaymerd WeadierLocke r underlayment I Drip— Nip edge Drip— edge w Drip edge Ddp— �. edge —Nal located Na7c treated from eave 2`.a'from cave Install first Self-sealing adhesive Sellbea6ngadhasive Starter Str' positioned along cave histet rirststarter SMpPtus positioned along eve shingle Wrtit with6'removed g 6"removed • � �" Starter Strip shingle overhangs eaves and rakes!4 4V Starter Ship Plus overhangs eaves and rakes 1/4--3/4' Exterior Research and Design,LL[. Evaluation Report 037940.02.12-R6 Certificate of Authorlratlon#9503 FL10674-R21 Revision 6:10/15/2015 Page 3 of 7 �,om: ~~'----- ---- '--- ' -- - - ' , x —'_ 6�.6 Minimum Nailing—cbxsicm&Supreme: NOMMI Mansard or Area pare Nonnml Mansard or Aron paw VWnd Areas High Wind deavan"y V61indArans ------ Mlfln*�_ —Wentostbortao-- Areas ----Area plow-viverom normajas--Areas zVOSICIdn 5�7 Minimum Nailing—Berkshirev LOW do$01adw qP a`w"_ - I.ayf --- 6�.8 Minimum Nailing—Dexon»hire~: Nails Nails Ten I'Spots of Asphaft Roof Gemerd ( ' Exterior Research and Design,uc Evaluation Report ourywzuzu2.no ^9503 Fu0674-nll Revision 6:10/lS/2015 Page*m7 — ---' — From., VG/G4/ZV"o vu:ca ncuv �•� ,,J 1 K1N1 t y ER- 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition' Duration'Designer Color Collection: 4Nall Pattem 6Nab .�++�.. htsama�Strepsb. Esquema do 4 clavos Pattern ma�di�aooio °� SutsNaiPfaswingamwidth Esqueos Area doUarosSumMils de 6 • • • iea3meNad>rtpu!^ tzvs�iarMraaTe. �. Suttxaim ���"�?:•��- \ StarNalP �• 4slldflraIDq alta � ..• 7rtawi0a _ fY _y R— Tr Amds rMW \ 7T SerN�t(a 6%'ExposureNails S te Expasu 94puy.doexposiWit fbm 54pufg.deexpaslafdn W Uposure News 536 Exposure S$hPufg.de t3tposfcion Cam Sh pule.de exposfd& 6.2.10 Minimum Nailing—TruDefinition'Oakridge°,OakridgeO: 4 Nall Pattern 6 Nail Pattern Esquema con4 claves Esgnema con 0clavos 14 4 5 5!8"Expawre Nalls 56 Exposute Nabs &pvdd6nda56/9put9. clavas Expos(ct a&ss/Bpulg. 55WExposute Clam 55m,Exposute 8rpasleF6n de fi b/B pule. fxpasfci6n deb 3/BpW¢ 6.2.11 Minimum Nailing—WeatherGuard®HP: t• .�f. �� t single Nrte ,••� :s':=�p� ': � lidww?latirltMltiYFlir awe w I11i1•il�tdfil 6.3 Nip&Ridge Shingles: 6.3.1 Installation of Berkshire*Hip and Ridge Shingles,High Ridge,Hip&Ridge with Sealant,WeatherGuard'HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four(4) nails per shingle. Installation of DuraRidge'", Hip & Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations,including the use of hand-sealing for wind warranties. Exterior Research and Design,U.C. Evaluation Report 037940.02.12•R6 Certificate ofAuthorhatlon#9503 FL10674-R11 Revision 6:10/15/2015 Page 5 of 7 From: 02/24/2016 03:26 ii .uuoiu-lu 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. ` 6.3.3 Minimum Nailing—Berkshire°Hip&Ridge and High Ridge: Fig.I ? Fig.2 f— PlOfdUWV ,d 1,01 DVeWon \,A\ Top%im sideView F' N.11% Nabs !I 4.. Topl.&-alai 2� 1 �Fxpcsisa � 0- g 1 Pima \ 6.3.4 Minimum Nailing—Hip&Ridge with Sealant: ent Fig.2-High Wind Fwmbg Pattorn (4 Nails) rine Shingle+LS:" and Discard 2„ Excess Seaila nt --Strip 72" Fassteening 6F�us�e+� Distance 6.3.5 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig.A Pnrvas9 g WB d — 9 Y TopVbw t—Dlladbo � A Halls Nails Nails ' Expoaul� \ BEcpowna I I Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6 Certifkate of AuthoNratlon#9503 FL10674-R31 Revision 6:10/15/20is Page 6 of 7 From: ,;d,e°,if".n °�.�" ' ' � —' — I T | 63.6 Minimum Nailing'PmEdgaHip QRidge Shingle : Prevailing Standard Pattern 12- Sealant Fasten 7V 6"Ex4mure osed with Reof Cement 63.7 MinimumNoiling—ouraRldge"Rip&Ridge Shingles: Note The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. va�jlng=ffirocdon Top View Dimedibn del iiwbp prodoff�mma Wit..1 1. 1'4+ 00 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1SU7'2J.1/R9U6.2.6iz. 8. BUILDING PsnxxrrRsQu|ncMemro: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9' MANUFACTURING PLANTS: Contact the named QAentity for information on which plants produce products covered by Florida Rule 9N'3 QA requirements, ' 10. QUALITY ASSURANCE ENTITY: UiLLC—QUA96%S;(4l4)248'64O9/ - END OFEVALUATION REPORT' Exterior Research and Design,uc Evaluation Report msn94o.0z.12-R6 u"tifuat"wwuth*mzamanxsm pL10674-nzl Revision o.10/Is/20z Page 7 o 7 ' , From: 02/24/2016 03:26 0253 P.00u/ono Certificate cfAuthorization No.28834 K1�2 E6�bu�hDr -- '- __-__ ___ '-----, ------ --'------' -'--- - ''—' --' ' TECHNICAL SERVICES,SERVKCES, LLC (813)480-3421 EVALUATION REPORT 2014 FLORIDA BUILDING CODE Manufacturer: OVVENGCORNING ROOFING AND ASPHALT LLC Issued February 23,20/5 1Owens Corning Parkway Toledo,OH43857 (8U0)438-7485 Manufacturing Plants: Atlanta,GA Compton,CA Denver,CO Irving, TX Kearny,NJ Medina,OH Memphis,TN Portland,OR Summit,IL Quality Assurance: uLLLC(QUA9O25) SCOPE ' Roofing Subcategory: Asphalt Shingles Code Sections: 1507.2.5.1507.2.7.1 Properties: Physical properties,Wind Resistance RspsnsmCso gn!yY Report No. Standard Year UL Luc oco) x0e962 ASTMlD 3^s2 ' 2009uL LLC mux 13wx05962 ASTM Do1o1 ' 000y UL LLC sou 13mx05$62 :..,.ASTM D 715 /! onnuu UL LLC 62813mw05962 � � ' 1995 UL LLc(TnTn62m) 13mK05862 .:ASTM G1o5. 2005o p UL LunSro�m) mNxbmoou �[w�K`'�� 2011 PRODUCT DESCRIPTION AND Ap9uoATIom SWPREMB@& ASTM D 3161. Class F &ASTN D 7158, Class Hfiborglaao reinforced, 3-tau asphalt CLASS/C@ roof shingle. Unless otherwise noted, the following application details shall 6ofollowed for New and Existing construction. Basic Wind Speed: Max.184mph Dauk(Non'HVMZ): |naccordance with FBCrequirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7nGin.OSB existing construction. Undndoyment |naccordance with FBCand manufacturer's requirements. Min.slope: 2:12 and in oncondonoo with F8C requirements. Contact the OVVEN8 CORNING when installing at slope greater than 21:12. Installation: Installed with 5 in. exposure in auonndmnca with FBC requirements and manufacturer's published installation instructions. Nailing requirements are detailed below in Figures 1 &2. ncxI From: 02/24/2016 03:zti 4FG5:s r.u�ai��u CREEKOWENS CORNING ROOFING AND ASPHALT LLC Asphalt Shingles TECHNICAL SERVICES, LLC 3G Min.12 ga.corrosion resistertt roofing nail wfth min.3B"diameter head 11" Contimtous,factory-applied tab sealant 0 0 o iT 5 618' S' Figure 1. SUPREME®and CLASSIC® 4 Nail Patter 36" 10 Mn 12 ga corrosion resistant roofing nail with min.3/8"diameter head 1- Continuous.factory-applied tab sealant 0 0 Of o O Figure 2. SUPREME®and CLASSIC® 6 Nail Pattern LIMITATIONS 1) Fire Classification is not within the scope of this evaluation, 2) This evaluation report is not for use in the HVHZ. 3) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 5) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 6) Installation of the evaluated products shall comply with this report, the FBC, and-the manufacturers published application instructions. Where discrepancies exist between these sources,the more restrictive detail shall prevail. 7) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. OCR23001.1 Fl.16638-R1 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. From: 02/24/zo1(i UL5:2/ CREEKOWENS CORNING ROOFING AND ASPHALT LLC Asphalt Shingles TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. � �pgY R. pR7�,. 2015.02.2 %% G ``, P•'�'\G E SF'���'' �� 3 14:42:17 • No 74021 = �" -05'00' *: :* STATE OF :14 Zachary R.Priest, P.E. i0.(N'••& �•' Florida Registration No.74021 O R t a.'�jN%.`� Organization No,ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR13001.1 Fl-16638-RI Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify.CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein.