Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 4 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff SCIS Site Map Links Search Businessr � Ot 'll Product ApprovalPC��eSS� �(�� iUSER:Public T Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL17903 FEB ? 5 2Q1Q Application Type New PEFi'!'AT1-iNCz Code Version 2014 St. Lucie County, FL Application Status Approved Comments Archived ice] Product Manufacturer Steve's and Sons,Inc Address/Phone/Email 203 Humble Ave. San Antonio,TX 78225 (210)924-5111 jimp@stevesdoors.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Jim Parker Address/Phone/Email 203 Humble Ave. San Antonio,TX 78225 (210)924-5111 jimp@stevesdoors.com Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 01 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2016 Validated By Ryan]. King,P.E. ,° Validation Checklist-Hardcopy Received Certificate of Independence FL17903 RO COI CERTIFICATE OF INDEPENDENCE.odf Referenced Standard and Year(of Standard) Standard Year ASTM E1886 2002 ASTM E1996 2002 ASTM E330 2002 TAS 202 1994 Equivalence of Product Standards Certified By Sections from the Code http://floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDquTIuhTgK2%2bdy56... 2/25/2016 Florida Building Code Online Page 2 of 4 Product Approval Method Method 1 Option D Date Submitted 07/17/2015 Date Validated 10/27/2015 Date Pending FBC Approval 11/01/2015 Date Approved 12/15/2015 Summary of Products FL# deal,Number or Name Description 17903.1 A.Opaque Steel Door 6'8 Single Opaque"Impact"Steel Door-Outswing (X) Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL17903 RO II INST 17903.1.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 17903.1 for Design Pressure Ratings,any FL17903 RO AE EVAL 17903.1.1)df additional use limitations,installation Instructions and Created by Independent Third Party: Yes product particulars. 17903.2 B.Opaque Steel Door 6'8 Double Opaque"Impact"Steel Door-Outswing (XX) Configuration Limits of Use Installation Instructions Approved for use in HVHZ:No FL17903 RO II INST 17903.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 17903.2 for Design Pressure Ratings,any FL17903 RO AE EVAL 17903.2.pdf additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 17903.3 C.Opaque Steel Door 6'8 Opaque Single Steel Door"Non-Impact"-Inswing(X) Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL17903 RO II Inst 17903.3.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressbre: N/A Evaluation Reports Other:See INST 17903.3 for Design Pressure Ratings,any FL17903 RO AE EVAL 17903.3.pdf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 17903.4 D. Opaque Steel Door 6'8 Opaque Single Steel Door with Sidelite"Non-Impact"- Outswing or Inswing(OX or XO)Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No ELL7.901 RO II Inst 17903.4.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 17903.4 for Design Pressure Ratings,any FL17903 RO AE EVALIZ903.4.13dF additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 17903.5 E.Opaque Steel Door 6'8 Opaque Single Steel Door with Sidelites"Non-Impact"- Outswing or Inswing(OXO)Configuration Limits of Use Installation Instructions Approved for use in HVHZ:No FL17903 RO II Inst 17903.5.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17903.5 for Design Pressure Ratings,any FL17903 RO AE EVAL 17903.5.odf additional use limitations,Installation instructions and Created by Independent Third Party: Yes product particulars. 17903.6 F.Glazed Steel Door 6'8 Glazed Single Steel Door"Non-Impact"-Outswing or Inswing(X)Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL17903 RO II INST 17903.6.0 Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 17903.6 for Design Pressure Ratings,any http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquTIuhTgK2%2bdy56... 2/25/2016 STEVES AND SONS o°' � // 203 Humble Ave. �� N San Antonio,TX 78225 =s' -1=d M =Z r! Z6. 37A3"MAX.O A. %��'•. ....-• ' 4C z y FRAME WIDTH O S z On m o MO OPAQUE STEEL DOOR R��1tTr► � a 9 X W e E m o pp � LO Pu COUnt1l N aye 'maa2 OUTSWING st• °'e E ;Z "IMPACT' oa Z y iii 2 C3 O fn Z z o� 133 X ® o oz LL GENERAL NOTES $aW. J ¢� K ® 1. This product anchoring drawing has been evaluated and is in compliance with v, the 5th Edition(2014)Florida Bulding Code(FBC)excluding the"High Velocity V d Hurricane Zone"(HVHZ). o ° �w a 2. Product anchors shall be as listed and spaced as shown on details.Anchor ¢ a m a a embedment to base material shall be beyond wall dressing or stucco. m 3. When used in areas requiring wind bome debris protection,this product complies with Section 1609.1.2 of the FBC and does not require an impact 3 resistant covering.This product meets missile level"D"and includes Wind Zone 4 L as defined in ASTM El 996 and FBC Section 1609.1.22. " 4. For 2x stud framing construction,anchoring of these units shall be the some as o that shown for 2x buck masonry construction. D 5. Site conditions that deviate from the details of this drawing require further a engineering analysis by a licensed engineer or registered architect. � o 8 MAX. DESIGN PRESSURE(PSI) m TABLEOFCONNNIS SWING FRAME W i W SHEET# DESCRIPTION DIMENSION POSITIVE NEGATIVE o 1 Typical elevations,design ressures&general notes ° z d 2 Door panel construction details z 3 Horizontal cross sections OUTSWING 37.43"x 81.09" +4],Q -47.0 DATE, 7118115 g 4 lVertical cross sectioru 3 srntE: N.T.S. 5 Buckand:frameanchoring-2Xbuckmasonryconstrurtion 6 Frame anchoring-1 X owc:BY.. JK buck masonry constriction 'm cH c ar; LFS 7 Bill of materials&components 3 DRAwox FL-17903.1 0 SHEET t OF 7 N V :\Oienls\Steves and Sons-Permanent\A•Florida Product Approvals\FL-17903\C-Drewings\FL-17903(2014)\FL-17903.1-2dwg.21 79.50°MAX.PANEL HEIGHT 4 ON o �Zh 9 IJN �S O M it o N � a W - d T � _ a O Z o = C1 � o n W N m 'n° OCID c � � o 1J tJ b rti P 22 O N to m 0 ````LNtlntp7jT L .��y� � ;• No_43409 PRODUCT: DoeumerMo Pmpared Sr. VLyndon F. Schmidt �i• � 0 P.E: No. 43409 ..........•••••••.. IN J SIEVES AND SONS '111111111W, $ P y' -PART OR.ASSEMBLY: JZ,,BUILDING CONSULTANTS. INC. SI , 'rt DOOR.PANEL CONSTRUCTION in. P.O. 8ox 230, VolNeo, FL 33595 I NO DATE BY DETAILS Phone No.: 813.859.9797 REVISIONS F'BPE C.A. No. 9813 -0 201 5 R.W.BUILDING C13ABULTANTS INC. 1Oients\Steves and Sons-Permanenl\A-Florida Product Approvals\FL-17903\C-Drawings\FL-17903(2014)\FL-179D3.1-.2,dwg 31 A � �Z m 4 y 'v c< Pa W O p ha A a Cd !7 N z W Wiz` d V ® ® ® i►N •d ww wro ww N rn N � c:pa N lV rn w z Pe;. V 4'. A Q° °, . tTr cn c4 d 4 sr,0, W 4 ` --{M r" to 4' z tl° m 4 �4. O p z No.4309 g PRODUCT: Documents Prepored By: .+w„A�•,, ,,, Lyndon F. SoAmidt �ii�Citi• Q� ���� W STEVES AND SONS P.E. No. 43449ED r" \ PART OR ASSEMBLY: @rr r BUILDING CONSULTANTS, INC. �� to HORIZONTAL CROSS SECTIONS J�''I t� P.O. Box 230. Valrieo, FL 33595 NO DATE REVISIONS BY F'BPE C.A. No. 9813 Y Phone No,: 813.859.9197 X1.2015 R.W.BUILDING CONSULTANTS tNC. ;\Clients\Steves.and Sons-Permanent\A-Flodda Product Approvals\FL-179D3\C-Drawings\FL-179()3(2014)\FL-17903.1-2dwg,4.1 M A A r A V to SO •I °d a n ° Q 0 e . N N n° Z i N °a 0.15' > M C'SINK (TYP.) A V A I- MIN EMB.(iYP.) A W ° a n a N y C) Z P . T N It D ti 1-1/44'MIN. o m EMB,'(TYP.) n en a a. x� Q Z a o 1-1/4"MIN. EMB.(TYP.) `ol'F kCk4�/ No.49409 � PRODUCT: Documento Prepared By. Lyndon F. Schmidt �i� '. OR10.`.•'d\,�� STEVES AND SONS P.E. No..43409 ''_'��illl,,slONA4t0`� $ " 1— y PART OR ASSEMBLY: / BUILDING CONSULTANTS, INC. w r in ��/I�P.O. Box 230.Volrteo, FL 33595 I� to NO DATE �13Y VERTICAL CROSS SECTIONS VV phone No: 813.859.9197 REVISIONS FBPE C.A. No. 9813 0.2015 R.W.BUIL INC CONBULTANTB INC. ;:\Clients\Steves and Sons-Permanent\A-Florida product Approvals\F4-17903\C-Drawings\FL-17903(2014)\FL-17903.1-.2.dwg,5.1 03: N Z O z C nO "� a z� 191MAX 4' 0 •d. .l z �p m O.C.(Typ.) )TYP.) m 31"MAX. O.C.TYP. 7C A x 2 M `n m m c z z m n z 1 1 1 i 1 0 o� n z n� Fo r r O �is 14"MAX. a O.C.tiYP.) )Ti(P.)'��"� o a w w m a 3 °c 5.5" �a`F Sctf «`�`��V,.ti16EN9F•��`,ter+ N0:43409 Fy PRODUCT: oocumento Pmpomd By: .'� r f STEVES AND P.F.No F.4- s t� �i�, AXomOt.:0�°��• �u o VSONS �OIdAL�� z �qutsttlt��` IV W 0D PART OR ASSEMBLY: �A!BUILDINO CONSULTANTS, INC. O NO DATE B (� UCK AND FRAME ANCHORING 4Y P.O. Box 230, YotMco, F1 33595 8Y 2XBUCK MASONRY CONSTRUCTION Phone No.: 813.859.9197 REVISIONS FBPE CA No. 9813 0 2015 R.W.BUILOIND CONBULTANTB IND. -AClients\Steves and Sons-Peimanent\A-Flodda ProductApprov&\FL-17903\C-Dravdn9s\FL-17903(2014)\FL-179031-.2dwg.6.1 31"MAX. O.C.TYP..� x m OD P l ' • o� 0 0 �z b .' A = A y• 'a im o 41 j' •, T .• 0so 0 14"MAX. �� 6" o; O.C.(p'P.) (TYP.) I'll 0 a w N w --•I I--5.5^ . fit S...•A N6�4�i �. V•�vc�riaF••.T .� � a3ao9 ' m v a g PRODUCT: Dooumante Prepared Lyndon F. Schmidt �ii�••• .Z....... •(!��� n V STEVES AND SONS P.E. No. 43409 'ass/ j�pL \���` "'fill 1111\ $ to r y tb PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. IV - x u NO DATE BY FRAME ANCHORING Rw P.O. Box 2301 .659.9 7 33695 1X BUCK MASONRY CONSTRUCTION Phona A. o. 9859.8197 REVISIONS FBF'E CA. No. 9813 IP 2015 R.W.BUIL-0 CGN.ULTANT.INC. BILL OF MATERIALS .............. m ITEM DESCRIPTION MATERIAL o n A 1X BUCK SG i=0.55 WOOD B 2X BUCK SG>=0.55 WOOD =N T o* ' - . ' D 1/4"X 2-3/4"ELCO OR ITW PFH CONCRETE SCREW STEEL z �`iv,- y.. 0' MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI l 4.56" —{ ��►' °°�A n E CONCRETE L I '•.-....-• :��!/��` —o m a`o 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 $TEFL ��11 n pp���` o m - F 1/4"X 3-3/4"TTW PFH CONCRETE.SCREW G MAX.1/4"SHIM SPACE o a H 1/4"X 3-1/4"ITW PFH CONCRETE SCREW STEEL h om a4 Z J #10 X 2-1/2'PFH WS 1.15'MIN.EMBEDMENT) STEEL E'N0 9O=a K #9 X 2"PFH WS STEEL 4 3 2 SIDE 6 HEAD JAMBS a"� m d a L #8 X 2-1/2"PFH WS STEEL .0 M 3116'X 3-1/4"ITW PFH CONCRETE SCREW STEEL E z P 1/4"X 2-1/4"ITW PFH CONCRETE SCREW STEEL a 2 STRIKE JAMB-FINGER-JOINT PINE-SG>=0.42 WOOD 3 HINGE JAMB-FINGER-JOINT PINE-SG>=0.42 WOOD 4 HEAD-FINGER-JOINT PINE-SG>=0.42 WOOD z .7 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 12 WEATHERSTRIP QEBD650 Q LON 4.63 3.9i� <CL o 18 83"X 4.0"HINGE MIN 0.098"THICK STEEL ¢ m C 21 PASSAGE LOCK-KWIKSET SERIES W C," 22 DEADBOLT-KWIKSETSERIES 660 23 STRIKE PLATE STEEL o m 23A DEADBOLT STRIKE STEEL 24 49 X 5/8"PFH WS STEEL f a a 25 OUTSWING THRESHOLD ALUMINUM W/COMPOSITE SUBSTRATE ALUM./COMP. OUTSWING THRESHOLD } 26 #9 X 1"PFH WS STEEL m 30 LATCH&HINGE STILE&TOP RAIL-SG>=0.42 POPLAR 31 LVL LOCK BLOCK POPLAR e 34 BOTTOM RAIL-POPLAR LVL POPLAR 39 STEEL SKIN 0.030"MIN.THICKNESS STEEL 46 DOOR PANEL FOAMED CORE . z POLYURETHANE o _ o CONCRETE ANCHOR NOTES: n 1.Concrete anchor locations at the comers may beadprstedtomaintain the min.edgedIstanceto a modarlolnts. 2.Concrete anchor locations noted.os"MAX.ON CENTER mustbe adjusted to mahtotn.the mh. d v' edge distance to mortarjoinis.addtioncl concrete anchors maybe requited to erme the"MAX. z d ON CENTER"dmehsion are not exceeded. m v 3.Concrete anchor table: F a fi :MIN CLEARANCE MIN'CLFARANCE: p 5 s ANCHOR ANCHORMIN a TOMASONRY TA AplACFJdT m g TYPE SIZE EMBEQMENT ;ANCHOR, O z ....:: ... ..... ...:.EQGE i - .. 17W 1/4" Z a E TAPCON® 7/18/15 z ELCOScUL N.T.S. a IILTRACON 1/4" IAN 1" 4" awc en JK m n ® 3/16" 1-1/4" 3" 1.1/2" CHK.9Y: LFS '3 v TAPCON A WOOD SCREW INSTALLA77ON NOTES: DRAWING No.: rc 1.Maintoln a min1mum 5/Bredga distance,fend dutance,a l"o.c.spacingof wood FL-17903.1m screws to prevent the"sp6ffing of wood. a sHm 7 oF7. N G