Loading...
HomeMy WebLinkAboutProduct Approval (2) L � 7/4/2015 Florida Building Code Online -., 777777 7777777",777, 7,7 [y .iJ( d*animent BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications 1 FBC Staff ! BCIS Site Map Links I Search E Busines J Professignal �sER PcblAppfoval { q� Reguiaiion Product Approval Menu>Product or Application Search>Application Lis[>Application Detail 1 , FL# FL15781-R5 Application Type Revision ly Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Soft Lite LLC Address/Phone/Email 10250 Philipp Parkway Streetsboro, OH 44241 (330) 528-3400 Ext 1109 jti nker@soft-lite.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity Farabaugh Engineering and Testing, Inc Quality Assurance Contract Expiration Date 12/31/2016 Validated By Ryan J. King, P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL15781 R5 COI CERTIFICATE of INDEPENDENCE.Ddf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2011 AAMA/W DMA/CSA101/I.S.2/A440 2008 ASTM E1300 2004 ASTM E1886 2005 ASTM E1996 2006 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Sections from the Code httpsJ/floridabuilding.org/pr/pr_appdtl.aspx?param=wGEVXQwtDgt3e1SAInEOW9Taf7MFDxJOVotb9tNgzgrfLEou%2fbEojg%3d%3d 1/3 c 7/4/2015 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 04/29/2015 Date Validated 04/29/2015 Date Pending FBC Approval 05/06/2015 Date Approved 06/22/2015 Summary of Products __. _..- .....-------._....._._.._........................----_........................-- --....-...................... -—__._.............................._.._..._..__......................... --__—_....................... FL# Model,Number or Name Description 15781.1 l a. "Imperial LS DSL12"Double Extruded PVC Double Horizontal Sliding Window-(XX Slider Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15781 R5 II Inst 15781.1.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15781.1 for Design Pressure Ratings, any FL15781 R5 AE Eval 15781.1.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15781.2 b. "Imperial LS TSL12"Triple Slider Extruded PVC Triple Horizontal Sliding Window-(XOX Window Configuration) .......... __ — Limits of Use Installation Instructions Approved for use in HVHZ: No FL15781 R5 II Inst 15781.2.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15781.2 for Design Pressure Ratings, any FL15781 R5 AE Eval 15781.2.0 additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15781.3 c. "5300 DSL53(G5352)"Double Extruded PVC Double Horizontal Sliding Window- (XX Slider Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15781 R5 II Inst 15781.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15781.3 for Design Pressure Ratings, any FL15781 R5 AE Eval 15781.3.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15781.4 d. "5300 DSL53(G5352)" Double Extruded PVC Double Horizontal Sliding Window-(XX Slider Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15781 RS II Inst 15781.4.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15781.4 for Design Pressure Ratings, any FL15781 R5 AE Eval 15781.4.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15781.5 e. "5400 SSL54(G5402)"Single Extruded PVC Single Horizontal Sliding Window-(OX or XO Slider Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15781 R5 II Inst 15781.5.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15781.5 for Design Pressure Ratings, any FL15781 R5 AE Eval 15781.5.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15781.6 f. "5400 SSL54(G5402)"Single Extruded PVC Single Horizontal Sliding Window-(OX or XO Slider Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15781 R5 II Inst 15781.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 https://floridabuilding.org/pr/pr_app_dtl.aspx?param=w q 1 nEOW9Taf7MFDx o gzgrfLEou%2fbEojg%3d°° 213 7/4/2015 i Building Code O 1 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See IN 15781.6 for Design Pressure Ratings, any FL15781 R5 AE Eval 15781.6.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15781.7 g. "5400 TSLF54"Triple Slider Extruded PVC Triple Horizontal Sliding Window-(XOX Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15781 R5 II Inst 15781.7.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15781.7 for Design Pressure Ratings, any FL15781 R5 AE Eval 15781.7.1)df additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15781.8 h. "5400 TSLF54"Triple Slider Extruded PVC Triple Horizontal Sliding Window-(XOX Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15781 R5 II Inst 15781.8.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15781.8 for Design Pressure Ratings, any FL15781 R5 AE Eval 15781.8.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 0 0 Contact Us:: 1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product PIS Accepts: IMED Y-.� eChec SCC U rlty'll:'I MM Xe httpsJ/floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgt3elSA]nEOW9Taf7MFDxJQVotbgtNgzgrfLEou°/*2fbEojg`/o3d`/o3d 3/3 r � R R W Building Consultants, Inc. VY Consulting and Engineering Services for the Building Industry B P.O,Box 230 Valrico,rL 33595 141anc813.659 0197 CFlonda Board of Professional Enginccn Ccrti6ene of,Wtharixntion No.9813 EvaluationFroduct T ' 1.6Date: April r ,2015 Product Sub Category Manufacturer Product Name Category Sort-Lite LLC "5400 SSL54(GS402)" Windows Horizontal Slider 10250 Philipp Parkway Single Slider Window Strootsboro,OH44241 "impact" (330)528-3400 Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc,and Lyndon F.Schmidt,P.E.(System ID#1998) for Soft-Lite LLC based on Rule Chapter No.61G20-3,Method 10 of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F,Schmidt,P,E,do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved In the approval process of the product named herein. (.imitations: 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building DY tructural requirements Including the"High Velocity Hurricane Zone". 2. Product anchors shag be as listed and spaced as shown on details,Anchor embedment to base materiale beyond wall dressing or stucco. 3. When used in the'HVHZ'this product complies with Section 1626 of the Florida Building Code anquire an impact resistant covering. 4. When used in areas outside of the'HVHZ'requiring wind tome debris"protection this product comction 1609,1.2 of theFBC anddoes not requirean impact resistant covering.This product nieets missile level"D"and inZone 4 as defined.in ASTM E1996 and Section 1609.1.2.2 of the FBC. 5. For 2x stud framing construction,anchor ng of t ese units shall be the same as that shown for 2x buck masonry'construction. 6. Site conditions that deviate from the details of drawing FL 15781,6 require further engineering analysis by a licensed engineer or ' t 7. This product meets th�water filtration requirements for"�elrern�ants u to m n tst er .s e of FBC Section 2003. 9. See drawing FL-15781.6 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed b TEL 03001201 TAS 201,202&203-94 Testing Evaluation Lab. William Shelton,P.E 2. Miami Dade NOA Materials Testing 13-0129.27 DuPont Uutaeite'PVB Interlayer 14-0820.11 PVC Extrusions(Vision Extrusions Ltd.) 3. Drawing No. Prepared by Signed&Sealed by No.FL-15781.6 RW Building Consultants,Inc.(CA#9813) r Lyndon F.Schmidt,P.E. 4. Calculations Prep gd by a '%fared&Sealed by Anchoring RW Building Consultants,Inc(CA#9813) 'u Lyndon F.Schmidt,P.E. ASTM E1300 Glass Lead Lyndon F.Schmidt,P.E. 5. Quality Assurance Certificate of Participation issued by Farabaugh Engineering and Testing,Inc,certifying that Soft-Lite LLC is manufacturing products ti-w'ugx within a quality assurance program that complies with ISO/IEC ;- 17020 and Guide 53• Lyndon F.Schmidt.P.E. FL PE No.43409 4/2912015 Sheet 1 of 1 fit L te �Wll1CiOWS 'moi�• •'•.. .... \\ o m m Bringing quality to light, p � JN 10250 Philipp Parkway r r rrL� 0 a m z Streetsboro,Ohio 44241 — SEE CHART FOR FRAME SIZES 0� o v_ z o z v�a " oa 2m `Dci a _ a v'a m dtarm.. "5400 SSL54 (G5402)" 0z Single Slider Window IM IM "IMPACr' w �Z a o LL GENERAL NOTES 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida �,k3 Building Code(FBC)structural requirements including the"High Velocity Hurricane Zone" _ v —[3 (HVHZ). U rc 2. Product anchors shall be as fisted and spaced as shown on details.Anchor embedment to o a base material shall be beyond wall dressing or stucco. a a 3. When used in the"HVHT'this product complies with Section 1626 of the Florida Building Code � / m and does not require an impact resistant covering. � / U 4. When used in areas outside of the"HVHT'requiring wind borne debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering. v This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM El 996 and $ci rn Section 1609.1 M of the FBC. z o z N 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. o 0 6. Site conditions that deviate from the details of this drawing require further engineering analysis o by a licensed engineer or registered architect. `T N 7. This product meets water infiltration requirements for"HVHT'. a w 8. Aluminum components,including fasteners,shall meet the requirements of FBC Section 2003. a N m ESSURE(PSI)_GLASSTYPE;:TABLE OF CONTENTS i POSRIVE NEGAITVE'i DAUB6 19 13SHEEN DESCRIPTION qiii 2" G7 +$Q,Q Sp,p sr•Lr• N.T.S. 1 Typical elevations,design pressures and general notes DWG.BY. Ou m 2 Horizontal and vertical cross sections CHK.BY: 3 3 Buck and frame anchoring rc NOTE:In the"HVHP',this product s not to be installed over 30 h,height above d. DaAFL NO.: 4 Bill of materials,components and gl®ng details _ FL-157a SKEET 1 O4; N R:\Clients\Soft-Lite Pennanen[\florida Product Approvals\FL-15781 Horizontal 9iden\C-Drawings\fL Current Drawings(2014)\FL•15781.5.6.dwg,2.6 , O N r 2:10 0 M 3z n o N ..� m (D N to �� as a 0 T � 21 0 O v' W a n'O A U A N W N N N U N O. m A 0 N W N N 0 T o p E n x ❑ J a 0 ❑ ❑ O O tA �� Z O Z M m W Q � N n X v X!~ O �n O Z O T � T 1-1/4"MIN. �O O 1-1/4"MIN. EMB.(TYP.) A EMB.(TYP.) ttI I111TT� scHM�o v,.•�ucBxaF••.1•'. No.43409 •*� PRODUCT: Do.—t.P-p—d 9y:i�% •• � P SOFT—LITE WINDOWS Lyndon F. Schmidt s •�IORIDR••'yG\���` INI rn P.E. No. 43409 V//Vjs�Q(V14�.•G-\��` ��l/lllllttl\` 'o' r y 2 4721715 UPDATE TO 5TH ED. (2014T FBC JK PART OR ASSEMBLY: ��/BUILDING CONSULTANTS, INC. 00 1 12/75/14 REVISED DRAWING NO. JK HORIZONTAL AND VERTICAL �41� P'0. Box 230• ValNco, FL 33595 NO m DATE BY Phone No.: 813.659.9197 REVISIONS CROSS SECTIONS FBPE C.A. No. 9813 ®2013 R.W.5UILDING CU-8 INC. Z�•yf � ��J-Z M ? z 2'• 14"MAX. ............'�/�`� o m m �(TYP.) O.C.(TYP.) `` z N i (TYP.) . v o x Z d \ LO a CW do E oz I I TYP. III F 2X BUCK 2X III G 1X BUCK 2X I I BUCK III DIRECTTO BUCK I FRAME III MASONRY _ _ MASONRY I I MASONRY III nP• o z OPENING I I OPENINGIII sc n z_ III �� 3 J `+' `Oo 5 III I o I I ao III o III �co o Y o a ¢ m h 3 L BUCK ANCHORING FRAME ANCHORING 4 Nin Z Z Z � W Z n = CONCRETE ANCHOR NOTES., w�� o_ 1.Concrete onchorlocations at the comers may be adjusted to maintain the min. 0 0 edge distance to mortar joints. 1 w 2-Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to o maintain the min.edge distance to mortarjoints,additional concrete anchors a may be required to ensure the'MAX.ON CENTER"dimension are not exceeded. X ttP. HEAD AND SILL v z 3.Concrete anchor table - t % ANCHOR ANCHOR MIN MIN-CLEARANCE 'MIN CLEARANCE- w o TYPE. SIZE EMBEDMENT.: TO MASONRY TO ADJACENT v° 'm EDGE ANCHOR' - v w Z 4 RL- 9 13 =ELCO .T.S.ULTRACONe 1/4" 1-1/4" 14" 3 € DWG.sr: JK m WOOD SCREW INSTALLATION NOTES: DHN.Er,: LFS ; 1.Maintain a minimum 5/8"edge distance,I"end distance,&I"o.c.spacing of DRAWING NO.: wood screws to prevent the splitting of wood. FL-15781.6 n � o SHELr_�L OF 4 N BILL OF MATERIALS ���`���``"* "Y4r��,, TLEM 0 DESCRIPTION MATERIAL 3.72" `O.� A 1X BUCK SG>=0.55 WOOD B 2XBUCKSG>=0.55 WOOD C 1/4"MAX.SHIM SPACE 'N'.� z F•'0 a� D 14'X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL MASONRY •. E 301 OR HOLLOWOPSI MIN.BLOCK COONCRETE NFORMINGOTO ASTM IC OMING TO ACI CONCRETE ����/i1111 PIP „�` ``\ z o m o F #10 X 2-1/2"PPH SMS STEEL u N o Z G 1/4"X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL \1 tiro E m z m°o J X #8 X 3"PPH SMS W/RUBBER WASHER STEEL cmi ❑ V moa ='m o`o a 1 MAIN FRAME" PVC a s d a 2 LOCK STILE` PVC �Z 3 PULL STILE' PVC �w 4 MEETING STILE' PVC :0-06- A 3a 5 GLAZING BEAD` PVC �Q 7 REINFORCEMENT(6063-T5 ALUM.) ALUM T z 9 RAIL` PVC 20 PUSH BUTTON SWEEPLOCK I 325" 21 PUSH BUTTON SWEEPLOCK KEEPER MAIN FRAME z o 23 #7X 3/S"PFH MS STEEL I— 2.31" 26 #6 X 1"PFH TEK SCREW STEEL I w w THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY O ❑ o EXTRUDERS LICENSEES IN"HAMA CERTIFICATIONS PROGRAMS FOR RIGID PVC EXTRUSIONS". ti o 0� 1.3T O.OT' a Of < d D] GO n o NEXT GENERATION(DOW)OR O 0.065' =H INSTANT GLAZE III(DOW) j0.08 I"GLASS BITE 1.35' 7/8"THICK , REINFORCEMENT , GLAZING BEAD 2 LOCKSTIIE N ci In z o 0 1.51" 2.31 E " z N 1(8'ANNEALED 0.090'DuPONT Butacite® L�O 2.59' PVB INTERLAYER 7 o 1/8"ANNEALED �' Com❑ D O _ m L0.07"'— ❑ _ F w z 1/8"ANNEALED _ 0.07' n o h N m 0.065 ❑ DATE- 6119113 i h sOnM- N.T.S. o STEEL SPACER I I Dwc BY: JK a h^— m G� GLALNG DETAIL DRC NLFS 3 3 PULL ST]LE ORnwwG NO.: m 9 RAIL 4 MEEDNG5711E FL-15781.6 0 sir_�L OF 4 n