FL1.1602-R3
Application'Type Revision
Code Version 2014
Application Status Approved
Comments
Archived.
Product Manufacturer InterWrap,Inc.
Address/Phone/Email 32923 Mission Way
Mission,NON-US 00000
(551)574-2939
mtupas@i nterwra p.cpm
Authorized Signature Eduardo Lozano
eloza nb@ interwra p.writ
Technical.Representative Eduardo Lozano.
Address/Phone/Email 32923 Mission Way
Mission,NON-US00000
(778)945-2891
elozano@ interwra p,co.m
Quality Assurance Representative
Address/Ph'one/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from.a Florida:116gistered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or',Architect'Nan e Whd developed Robert Niernirien
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity Intertek Testing.Services NA Inc.-ETL/Warnock Hersey
Quality.Assurance Contract Expiration Date 11/19/2016
Validated By John W. Knezevich,PE
R Validation Checklist-Hardcopy Received
Certificate of Independence FL11602 R3 COI' 201501 COI Nieminen.Ddf'
Referenced Standard and Year(of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
1507.2.3
1507.2.4
1507.2.8
1507.2.9.2
1507.3.3
1507.4.5.1
http://www.tloridabuilding.org/pr/pi_app_dtl.aspx?paranl=wG.EVXQwtDgsQFc5 KD/o2f Fr... 1/18/2016
Florida Building Code Online Page 2 of 2
1507.4:5.2
1507:.5.3
1507.7.3
1507.8.3
1507:9:3
1523.6.5.2.1
Product Approval Method Method 2 Option B
Date Subrnitted 05/01/2015
Date Validated 05/01/2015
Date Pending FBC Approval QS/10%2015
Date Approved 06/22/2015
Summary of Products
FL# Model,Number or Name Description
11602:1 Titanium Rool Underlayments synthetic sheet-type roof ttnderlayments
Limits of Use Insfallation.Instructions
Approved for use in HVHZ:No. FL 1602 R3 If 2015 05 FINAL.ER INTERWRAP F11111602-.
Approved for use outside HVHZ1 Yes' R3.Ddf
Impact Resistant:N/A Verifie'd:Byi Robert NI'eminerl:,PE-59166
Design Pressure:+'N/A/=45' Created by Independent Third Party:Yes
Others 1.)The design pressure noted herein. pertains,to Evaluation Reports
use of a specific underlayment,systern beneath foam-on tile ki'1602 R3 AE 2615 :05_FINAL ER INTERWRAP...FL11602-
sytsems.Refer to.ER,Section:5.6.3 for'details.'.2.)Refer to R3.DdF'
ER'Sections 5 and 6 for other Lirhits of:Use. Created by Independent Third Party:Yes
Back Nezt
ContaEt:Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-.t824
The State.of Florida is an AA/EEO employer.Copvriaht'2007-2013 State of Florida.::Privacy Statement::Accessibility-Statement::Aefund Statement
Under Florida law,email addresses are'public records.If you do not want your e-mail address released In response to a,public-records request,do not send
electronic mail to this entity.Instead;contact the office by Phone or by traditional mail.If you have any'questlons;.please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida;Statutesi:effective"Octotier 1,2012,licensees licensed under Chapter 455;F.S.must provide the Department with an email•address.if
'they'have one:The emaiis;provided maybe`umd:for official communication with thedicensee.However email ada
dressesr'e public retvrdi If you do not wish to
supply a personal address,please provide,theDepartment with an-.email addrem
ss which can be ade available to the public.To determine if you are a'licensee under
.Chapter 455;F,S.,please click_.here
Product Approval Accepts-
sccuntyNF.Tiucv
a
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5 KD/o2t Tr... 1/18/2.016
EXTERIOR RESEARCH;&DESIGN;LLC.
Certificate of Authork6tion#9503
`'�/ p35-3 CHRISTIAN STREET, UNIT#13
oTaI 1 I ERD OXFORD,& 06478
PHONE:(Z03)262-9245
FAX:(2'03)262-9243
EVALUATION REPORT
interwrap,Inc. Evaluation Report 111980_11.08-R3
32923 Mission Way 171-11602-113
Mission,BC V2V-6E4 Date of Issuance:;11/.03/2008.
Canada Revision 3:05/01/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction,materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under.the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have I'een;evaluated for compliance with the 5t11 Edition(2014)Florida Building Code sections noted herein.
DESCRIPTION:Titanium'"Roof Underlayments
LABELING. La.beling,si all be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the.named products) Changes, the referenced
Quality Assurance documentation changes;or provisions of the•Code that relate to the product change. Acceptance,ofthis
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance.documentation changes. TrinitylERD requires a complete review of this Evaluation Report
relative to updated'Code requirements'with each:Code Cycle.
ADVERTISEMENT: The: ,Evaluation Report number preceded by the words "Trinityl!ERD Evaluated" may, be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be clone in its entirety.
INSPECTION: Upon request, a copy ofthis entire Evaluation Report shall be provided to the user by the.manufacturer or its
distributors and shall be available for inspection at the job site at the request 6 Ahe Building Official.
This Evaluation Report consists of pages 1_through 6:
Prepared by: ,�,itttttrpf, —
- ccs PL'`o-"'`�•'/�%"
'tom 3.z.o 3?a'as" a
F
F q�Cr The,-facsimile sealappear[ng was.author(zed by Robert Nlcminen,
Robert J.M.Nieminen;P.E. 4'S�rO�!>t 4 r P.E on0S/01/200.This does net serve as anelectron(callys(gned
4r.rrnnnts�•s
Florida Registration N0;59166;Florida DCA ANf1983_ d«ument.Signed,sealed haidcopres Have been transmitted to the
Product Approval Administratorand to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinityI ERD does.not.have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityi.ERD is not owned,operated or controlled byany company manufacturing or distributing products it evaluates.
3. Robert.Nieminen,PZ does not have nor will acquire;a financial interest in any,company manufacturing or distributing products for
Which the evaluation reports-are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any;other entity involved in the approval process of the
product.
5. This is a, building code.evaluation. Neither Trinity IERD nor Robert Nieminen, P.E:.are,:in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used.for permitting or design guidance unless,retained
specificallyfor that purpose,
J ,
�TkINITY(E R D
ROOFING COMPONENT"EVALUATION:
1. SCOPE'
Product Category: Roofing
Sub-Category: Undeilayment
Compliance Statement: TitaniumT' Roof Underlayments, as produced by Interwrap, Inc:, have demonstrated compliance with
the 'intent of the:following sections of'the Florida Building Code through testing.in accordance with applicable, sections the
following Standards: Compliance is subjectto"the Installation Requirements and Limitations/Con'ditions.of Use"set'forth.herein.
2. STANDARDS:
Section Proper tir Standard Year
1507.2:3,1507:33,15075.3;,1507:7:3, Unrolling;Breaking Strength,Pliability, ASTM D226 2006
T1507.8;1507:8.3,1507.9.3 Loss od eating
15073.4,1507.2.8,1507.2.9.2; Thickness,Load-Strain,Adhesion,Thermal ASTM D1970 2009
1507.4.5.1,15,07.4.51,1507.5.3, Stability,Flexibility,Tear„Permeance
1507.5.3.2,1507.7.3,1507.7.3:2
1507.3.3 Installation Practice; FRSA/TRI April 2012(04-12) 20112
1523.6.5.2.1 Physkal.Propert es(2-plysystem) TAS 103, 1995
TAS 110 Accelerate&Weathering -TAS 116 2.000
3. REFERENCES:
taii!Y Examination Reference- Date
ERD'(TST6049) Physical Properties .115010;04-.09 04/29/2009
ERD(TST6049) Physical Properties 115010.05:10 05/14/2010
ERD.(TST6049) Physical,Properties 135520:06:11 06/15/2011
ERD(TST6049) Wind Uplift 135526.08'.11-1 08/12/2011
ITS(TST1509) Physical Properties 3146738COQ-003A 03/28/2008
ITS`(TST1509) Physical Properties 3146738COQ-0038 03128/2008
ITS(TST.1509) Physical'Properties 3126617COQ-005 16/31/2007
ITS(QUA1673) Quality Control 1TS Listings Current.
ITS(QUA1673) Quality Control Inspection Report' 11/10/2014
4. PRODUCT DESCRIPTION:
4.1 Self-Adherine.Underlayments:
4.1.1 Titanium`" PSU-30 is.an unreinforced polymer modified bitumen material adhered to_the underside of a polymer-
coated,syntheticwoven sheet. The underside:is backed with a release film. Unit Weight 24 lbs/square..
4.2 Mechanically.Fastened Underlayments:,
4.2.1 . Titanium`" UDL'25.is-'a synthetic sheet-type underl'ayment comprised of a woven core coated on one side with a
polymer coating. Unit weight 2.5.Ibs/squa"re:
4.2.2 Titanium'"UDL-25 PLUS is a synthetic sheet-type underlayment comprised of amoven core coated on one side with a
polymer coating. Unit=weight2.91bs/square.
4.2.3 Titanium'" UDL-30 is a.synthetic sheet-.type underlayment comprised of a woven core coated on both sides with a
polymer coating. Unit weight4.01bs/square:
4.2.4 Titanium"" UDL-50 is a synthetic sheet=type underlayment comprised of a woven core coated on both sides with a
polymer coating. Unit weight:4.716s/square.
4.2.5 Titanium`" UDL-TT is a synthetic.sheet=type underlayment comprised of a woven core coated on one side with a
polymercoating. Unit weight'2.91bs/square
4.2.6 Titanium'" UDL-TF is a.synthetic sheet=type'underlayment comprised of a woven core:coated on both sides with a
polymer coating. Unit Weight 2.9 lbs/squaPe.
4.2.7 UDL-TTMC300 is a synthetic sheet-type undeflayment.comprised of a woven.core coated on both sides with a:polymee
coating. Unit.weight 3.2 lbs/square.
Exterior Research and Design,I.I.C. Evaluation Report 111980.11.08-R3
Certificate of Authorization p9503 F1.11602-113
Revision3:05/01/2015
Page 2 of 6
QOTRINIIY, IERD
5. LIMITATIONS:
5.1 This is a building code evaluation.. Neither Trinity[ERD nor Robert Nieminen, P.E.are, in:any way, the Designer of
Record for any project on which'this Evaluation Report, or previous versions thereof, is/was used for:permitting:or
design guidance unless retained specifically for that purpose.
5:2 This Evaluation Report is not for use.in the HVHZ.
5.3 Fire Classification is not part of this;report;refer to current Approved Roofing Materials Directory" for fire rati ngs of this
product.
5.4 Titanium'"Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approvaldocuments. If not listed,a:request may be made-to the AHJ for approval based ori this evaluation
combined with supporting data for the prepared roof covering.
5.5 Al Iowa ble.Roof Covers:
Table 1: Roof Cover Optioits
Asphalt, Wood Shakes&
Underlayment Shingles Nail=On Tile Foam-OnTile� Metal. Shingles Slate-
FSU-30 Yes, Yes Yes Yes Yes Yes
(See 5.5.1)
UDL-25 Yes No No Yes Yes Yes
Yes Yes
UDL=25 PLUS. Yes (base layer in 2- (baselayefin2- Yes Yes Yes
ply system) ply system)
Yes Yes
UDL-30 Yes (base layer in 2- .(base layer in 2- Yes Yes Yes
ply system) ply system)
UDL-50 Yes No No Yes Yes Yes
UDL-TT Yes No No, Yes Yes Yes
UDL-TF Yes: No No-- Yes Yes Yes
tUDL-TTMC300 Yes No No Yes Yes Yes.
Private labeled
5.5.1 "Foam-On Tile"is,limited to use of 3M'"2-Component Foam-Roof Tile Adhesive AH460-(FL6332);or Dow TILE BOND'"Roof Tile
Adhesive(FL717) applications unless tensile adhesion / long term aging data from.an accredited testing laboratory,is,
provided.
5.6 Allowable Substrates:Titanium PSU-30
5.6.1 Direct-Bond to Deck:
➢ New.untreated plywood;
D Existing:untreated plywood;primed as needed with D41 primer to achieve bond.
5.6.2 Bond to Mechanically Attached Base Sheet:
y ASTM D226,Type I or II felt:
D Titanium UDL-25 PLUS,UDL730(primed with D41 primer.)or UDL-30(inverted).
5.6.3 Wind Resistance for Underlayment:Sysiems in Foam-On Tile Applications: FRSA/TRI April 2012(04-12)does not address
wind uplift resistance of all underlayment systems beneath foam on tile systems,where the underlayment forms part,
of the load-path. The following;wind uplift limitations apply to underlayment systems that are not addressed in
FRSA/TRI April 2012(04'=12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing
for wind load-resistance.based on allowable wind loads,and reflects the ultimate passing pressure divided'by 2(the 2 to
I margin of safety,per FBC 1504.9 has already been applied).Refer to FRSA/TRI April 2012(04-12);Appendix A,Table-1A,
or FBC 1609 for determination ofdesign wind loads.
5.6.3.1 Maximum DesiemPressure=-45 psf.
Deck: Min.15/3Z-inch plywood to meet project requirements to satisfaction of AHJ..
Primer: (Optional)ASTM D41
Underlayment: Titanium PSU-30,self-adhered
Exterior Research and DesignJI.C. Evaluation Report 111980.11.08-R3;
Certificate o[Authodiation 119503 F1.11602-113'
Revision 3:05/01/2015
Page 3 of 6
rTRINITY'IERD
5.6:3.2 Maximum Design Pressure=-30 psf*.
Deck: Min.15/32-inch plywood to meet project requirements:to satisfaction of AHJ.
Base Sheet: Titanium UDL-25 PLUS:or UDL730(inverted)
Fasteners: Mechanically attached with 12 ga.annular ring;shank nails having not less.than 20 rings per inch,.
Heads notless:than 3/8 inch diameter and length sufficient to pen_"etrate through the thickness of
deck not aess1han'3/16-inch with min.32 ga.;1-5/8"diameter tin caps
Spacing: '6-inch o.c.at 4-inch wide side laps and 12-inch ox.at three(3),equally spaced center rows.
Primer: ASTM D41primer required'atall tin=caps.
Underlayment: Titanium P$U 30,self-adhered
5.6.3.3 Maximum Design Pressure=-30 psf*.
Deck: Min.15/32-inch plywoodto meet project requirements to satisfaction of AHJ.
Base Sheet: Titanium,UDG30(printed side up)
Fasteners: Mechanically,attached with 12 ga. annular ring,shank nails having:not less-than 20,rings per inch,
heads not less"than 3/8 inch diameter and length sufficient,to penetrate through the thickness of
deck not less than,3/16-inch with min.32 ga.,, 1.5/8"diameter tin caps.
Spacing: 6-inch-o.c.at 4-inch:wide side laps and 12-inch o:c.at three(3),equally spaced center rows.
Primer: ASTM D41.irlmer required overprinted side of UDL-30.
Underlayment: Titanium,PSU 30,self-adhered
5.6.3.4 Maximum Design Pressure=-45 psf*:
Deck: Min:15/32,-inch plywood to,meet project requirements to satisfaction of AHJ.
Base Sheet: Titanium:UDL-25 PLUSor.UDL730(inverted)
Fasteners: Mechanically attached with 12 ga. annular ring shank.nails having riot less,than 20 rings per inch,
heads not less than 3/8 inch diameter and length sufficientAo.penetrate through the thickness of
deck not less than.3/16-inch with min.32 ga_1-5/8"diameter tin caps
Spacing: 6-inch o.c.at 4-'inch wide side laps and 8-inch o.c.at three(3),equally spaced center rows.
Primer: ASTM D41.primer requiredafall tin-caps.
Underlayment: Titanium.PSU 30,self-adhered'
5.6.3.5 Maximum Design Pressure=-4,5 psf'.
Deck: Min.15/32=inch,plywood"to.meet project requirements to satisfaction of AHJ.
Base:Sheet: Titanium'UDL=30(printed side up)
Fasteners: Mechanicallyattached with 12 ga, annular ring shank.nails having not less than 20,rings per inch,
heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of
deck not less than 8/16-inch with min.32 ga.,1-5/8"diameter tin caps.
Spacing: 6-inchro.c.at 4-inch wide side laps and 8-inch o.c.at three.(3),equally spaced center rows.
Primer: ASTM D41,primer required over printed side of UDL-30:
Underlayment: Titanium PSU.30,self-adhered
5.6.3.6, For mechanically attached base sheet'in a 2-plysystem;the maximum design pressure for the selected assembly shall,
meet or exceed the Zone 1 design pressure determined in accordance with FRSA/TRI April 2012(04-12),Appendix A,
Table IA or FBC 1609: Zones 2.and`3 shall employ an attachment density designed by a qualified design professional to
resist the elevated pressure criteria. Commonly used methods are RAS 117, FM L.PDS 1-29 and ANSI/SPRI WD1.
Assemblies marked with'an asterisk*`carry the limitations set forth in'Section 2.2.1:5:1(a)of FM LPDS 1-29 for.Zone 2/3
enhancements
5.7 Exposure Limitations:
Titanium UDL-25,UDL-25 PLUS,UDL-30,UDL-50,UDL-TT or UDLeTF'shall not be left exposed for longer'than 30-days.
Titanium PSU-30.shall not be left-exposed for longer than 90-days.
UDL-TTMC300 not be left exposed for longer than 180-days.
Exterior Research and Design,LLC. Evaluation Report i11980.11.08-R3
Certificate of Authorization#9503 FL11602-113
Revision 3:05/01/2015
Page 4 of 6
rTR1N1TY,[ER0
6. INSTALLATION:
6.1 Titanium: Roof Unclerlayments" shall be installed in accordance with'Interwrap published installation requirements
subject to the Limitations set-forth in Section 5.herein and the specifics noted below.
6.1 Re-fasten any loose decking panels, and check;for protruding nail heads. Sweep Wei s ubstrate,thoroughly to,remove
any dust and debris priorato application;and prime the substrate(if-applicable).
6.3 -,- _Titanium-UDL=25'UDL=25 PLUS UDL-30 UDL=50 UDL-TT,UDL-TF and(P.rivate1abeled)UDL=TTMC300:
6311 Install m compliance with manufacturer's..published installation instructions and the requirements for ASTM 15226,Type
I and II underlayments-in FBC Sections 1507 for the type of prepared roof covering"to be installed.
6:3.2 •— Fasteners:-
Mechanical..-attachment.of Titanium UDL-25, UDL-25 PLUS and UDL-30'is limited to ring.shank roofing nails with,
minimum 17inch diameter plastic caps
Mechanical,attachment of UDL=50,UDL=TT;UDL-TF and(Private Labeled)UDL-TTMC300.is limited to ring shank roofing
nails with minimum 3/8-inch diameter heads; ring shank roofing nails with minimum 1-inch diameter plastic caps;
screws and,plates;or plastic cap staples.
6:_3:3 Slopes of 4:12 or greater:,
End(vertical):Iapsshall be minimum.6-inches and side(horizontal)laps:shali.be minimum 44nches.
Minimum attachment shall.be 12-inches o.c:vertically and 24-incheso..c. horizontally in accordance with the surface
markings on the exposed face of.the underlayment. When.batten:systerns are:tobe installed atop the underlayment;
the underlayment need only be preliminarily,attached.pending•attachment of the battens.
6:314 Slopes of 2:12 to less than 4:12:
Double layer application; begin by fastening a 25-inch wide strip along the eaves:Place a full-width:sheet over the
starter,.completely Overlapping:the starter course. Continue as noted.in'6.3.3,but,maintaining,minim'um.25-inch side
(horizontal)laps,resulting in-a double-layer application.
6.4 Titanium'"PSU:-30:
6:4.1 Install in compliance"with manufacturer's published installation instructions and the requirements.for ASTM U1970
underlayments in FBC Sections 1507 for the.type of prepared'roof covering to be installed.
6.4.2• Di"sect=to=Deck with Mechanically Fastened Roof Cover:
Cut manageable sections and re-roll with the.release film side.out.
Membrane Application:
y Peel back release film approximately 1 to 2 feet and align with the lower edge of the rooUand set in place,printed
side up.
D Apply the,balance of the membrane to the substrate by removing the,film and firmly pressing the membrane into
place.
➢ Apply subsequent courses parallel to the eave in a shingle-type,water-shedding manner.
➢ End(vertical)laps shall-be minimum 12-inches and side"(horizontal)laps shall'be minimum 3-inches.
➢ If the membrane becomes misaligned,cut the roll and re-start.
➢ Upon completion,iii"spect1he merhbeane antl;repairany defects'orfisFi- ouths.
The use:of sealant or mastic at the fastener"penetrations is required for all tile roofing.installations. Contact Interwrap
for approved sealant or-mastic types._
6.4.3 Direct-to-Deck with Adhesive-Set Tile Applications:
Reference is:made to FRSA/TRI April 2012(0442)Installation Manual and Table 1 and'Section 5.6.2 herein, using the
instructions noted above as a guideline.
Wait a minimum of 24 hours prior to loading_ roof tiles.Tiles shall be staged so as to avoid slippage and/or damage to
the roof underlayment.
The use of sealant or mastic at tile,fastener penetrations is required for all.tile roofing installations. Contact Interwrap
for approved sealant or mastictypes.
Exterior Research.and Design,LLC. Evaluation Report 111980:11.08-R3
Certificate of Authorization#9503 FL11602-113
Revis ion;3:05/01/2015
Page 5 of 6
TRINITY I ERD
6:5. Titanium 2-PIy System:
6.5.1 The.Titaniurim System consists of'a base layer"of Titanium:UDL-PLUS or UDL-30: (top-surface;primed'dr inverted)
mechanically attached to the wood roof deck followed by Titanium,PSU-30,self-adhered.
6.5.2 Non-Tile Applications:
Install Titanium UDL-25 PLUS or UDL-30 (top surface primed;or inverted).in accordance with Sections 6.3.1 through
6.3.3-followed by`Titanium PSU=30 in accordance,with.Section 6.4.
6.5.3 Tile Applications:
"Reference is made to.FRSA/TRI April 2012(04-1$)"Instaliation Manual and Table 1 herein;using the instructions noted
above as a guideline.
For mechanically fastened tile roofing;,refer to Interwrap published installation instructions;but not less than FRSA/TRI
April 2012(04-12) "fable 1.
F.or adhesive-set the roofing,"refer to Section,5.6:3 herein.
Wait a minimum of 24.hours'priorto,loading roof tiles. Tiles shall be staged so as to avoid slippage and/or damage.to
the-roof underlayment.
The use of sealant or mastic at the fastener penetrations is required for all tile roofing installations. Contact Interwrap
for approved sealant or mastic types.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in orderto-properly evaluate the installatfonofthis-product.
S: MANUFACTURING PLANTS:
Contact the:named QA agency for information on production locations covered by F.A.C.Rule 61620-3 QA requirements.
9. QUALITYASSURANCE ENTITY:
IntertekTesting Services NA Inc.-ETL/Wamock Hersey—QUA1673;(604)520-3321
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC: Evaluation Report 111980.11.06-R3
Certificate of Authorization#9503 FL11602-113
Revision 3:05/01/2015
Page 6 of 6
Stingerworld The leader in cap systems technology Page 1 of 3
x {STINGER NEWS Yr
C.or 5CLtiGE.4:iavz and Vpd+tos
i THESYS'I'EM� a • o• • • � r >ta r
HAMMER TACKERS>CAP HAMMERS>CAP STAPLERS'>CAP MAILERS>CAP FASTENERS:>ROOFING NAILS
Cap fasteners are a recommended.BEST PRACTICE installation by housewrap
kF; and roofing undedayment manufacturers like DuPont, Typar, Grace,- and'
Titanium. Why?Because.caps help-seal out moisture'that can penetrate sidewall
and`,roofing fabrics. Caps provide;better holding power than a nail`'or staple
alone and that means reduced;blow-offs and lateral slippage! It also,means
fewer fasteners are needed to get the job done.
......................................_..........._......,....-......................................................._............,-.........................,..,....., ....,...............,......................-.................................... ....
SmT me
3/8"StaplePac for use with STINGER�CH38 and CH38A Cap Hamrners.only
Each 2016 count STINGER 3/8°StaplePaeinctudes 12-168 count reels of full L"plastic
7�2
collated caps and 24-84 count strips of ALL3/B"staples
Each StaplePac will cover approximately 2S square
. gym K3yj 5/8"Pneumatic StaplePac for use With'STINGER CS58 Cap Stapleronly
• Each 2000 count STINGER 5/8 StaplePac includes 10-200 count plastic collated caps
and 20-100 count strips of 5/8"`"staples
• Each StaplePac will cover approximately 25 square
7/8",11-1/4''8 1.112"Pneumatic StaplePac for use with-STINGER CS150 Cap
Stapler&Crossfire Cap Stapler only
1•�{ 9i14GB'R
lot -s"°"., formerly Crossfire StaplePac
l�
.{�8711162t1., • Available in 7/8",1-1/4'and I-1/2"
s Each 2000 count STINGER StaplePac indudes 10-200 count reels of full P'plastic
collated.caps and 20-100 count strips staples
• Each StaplePac will cover approximately 25 square
i...r..........:..r.r.:.i..•.i.,.e.........:�............................,............:.......................:e,.,..•....�...........,:...............ci,:,.:.•w...n..,..:..,...,:•F...,......•wd...e.........,:n:,e".,.,.a.aw.,;...,A.,.,..a.a.,
S'T'INGER NAILPAC'
_..I'-Pnoumatic_NailP_ac-fgr-use-with-SSlIIGER CN:100onli—/ .
Ic ,� w • Each.2000 count STINGER.VAzilIPac includes 10.r.200 counl.reels of full 11 plastic
collated`caps and 10-200 count-coils of wire collated;'1"electro-galvanaed"ring T hank
�`eS77n�r nails
• Each NailPac will cover approximately 25 square
f y
oes Here
Plash-Top@ and Round-Tope ProP8C5 for use with Hitachi NV50AP3 and Plasti-
Tacker•Plus@ Cap Nailers only(Pfasti-Tacker Pro' for use with Plastic,NailPad
and ProPac only)
• Available in7/8",l-1/4"and.2"lengths,
(� • Each 2800 count NailPac or ProPac includes 8-350 count reels of collated caps and.8-
350 count Coils of wire collated,electro-galvanized ring shank nails
•''"�' •. Each NailPac.or ProPac will cover approximately 35 square
1-1/4"NailPac or RolPac`for use with STINGER RT2 or.RT3 Cap Nailers only
• Each 3000 count NailPac includes 2-1500 count reels of 1"collated steel caps and
2-1500 count coils of whe collated,electrogalvanized ring shank nails
http://www.stingerworld.com/fasteners.asp 1/18/2016