Loading...
HomeMy WebLinkAboutProduct Approval i 'l•' ii �P�,�� ill`''�`. - �y/'�j� kj,-�y.° •y _ •t. ~loiidd l£ommefli;+ BCIS Home Lop In : User Registration Hot Topics Submit Surcharge Stats&Facts Publications MC Staff BCIS Site Map Unlls Search Busines Professional P P.aPub icUser al Regulation, Product Approval Menu>Product or Applicaion Search>Application List>Appllcouon Detail • x" FL# FL12793-R3 Application Type Revision Code Version 2014 Application Status Validated Comments Archived Product Manufacturer Therma-Tru Corporation Address/Phone/Email 118 Industrial Drive Edgerton,01-143517 (419)298-1740 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Address/Phone/Emall Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer / Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developeJ Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J. King,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL12793 R3 COI CERTIFICATE.OF INDEPENDENCE.odf Referenced Standard and Year(of Standard) Standard Year AAMA/NWWDA 101/I.S.2/A440 2005 ASTM E330 2002 Equivalence of Product Standards Certified By Sections from the Code hq://www.floridabuilding.org/pr/pr app_dti.aspx,?param=wGEVXQwtDgsmFBcODh9XI... 7/1/2015 Product Approval Method Method 1 Option D Date Submitted 05/30/2015 Date Validated 06/28/2015 Surnmary of Products FL# Model,Number or Name Description 12793.1 a."Craftsman"by Therma-Tru 6'8 Glazed Fiberglass Single Door utilizing the Flush Fit II (Fiberglass Entry Door) Glazing Frame-(X)Inswing or Outswing Configuration I r Limits of Use Installation Instructions `r Approved for use in HVHZ:No FL12793 R3 II Inst 12793.1.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 12793.1 for Design Pressure Ratings,any FL12793 R3 AE Eval 12793.1.pdf additional use limitations,Installation instructions and Created by Independent Third Party:Yes product particulars.(This product approval requires the use of"J"part number doors,which have been stained or painted within 6 months of Installation.) 12793.2 b."Craftsman"by Therma-Tru 6'8 Glazed Fiberglass Single Door with Sldelite utilizing the (Fiberglass Entry Door) Flush Fit Glazing Frame-(OX or XO)Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use In HVHZ:No FL12793 R3 II Inst 12793.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 12793.2 for Design Pressure Ratings,any FL12793 R3 AE Eval 12793.2.0df additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars.(This product approval requires the use of"?part number doors and sldelltes,which have been stained or painted within 6 months of installation.) 12793.3 c. "Craftsman"by Therma-Tru 6'8 Glazed Fiberglass Single Door with Sidelites utilizing the (Fiberglass Entry Door) Flush Fit Glazing Frame-(OXO)Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ:No FL12793 R3 II Inst 12793.3.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 12793.3 for Design Pressure Ratings,any FL12793 R3 AE Eval 12793.3.1)df additional use limitations,Installation Instructions and Created by Independent Third Party:Yes product particulars. (This.product approval regtalres the use of"J"part number doors and sldelites,which have been stained or painted within 6 months of installation.) 12793.4 d."Craftsman"by Therrna-Tru 6'8 Glazed Fiberglass Double Door utilizing the Flush Fit (Fiberglass Entry Door) Glazing Frame-(XX)Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use In HVHZ:No FL12793 R3 II Inst 12793.4.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 12793.4 for Design Pressure Ratings,any FL12793 R3 AE Eval 12793.4.pdf additional use limitations,Installation Instructions and Created by Independent Third Party:Yes product particulars. (This product approval requires the use of"J"part number doors,which have been stained or painted within 6 months of Installation.) 12793.5 e."Craftsman"by Therma-Tru 6'8 Glazed Fiberglass Double Door with Sidelites utilizing the (Fiberglass Entry Door) Flush Fit Glazing Frame-(OXXO)Inswing or OutsWing Configuration Limits of Use Installation Instructions Approved for use In HVHZ:No FL12793 R3 II Inst 12793.5 pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 12793.5 for Design Pressure Ratings,any FL12793 R3 AE Eval 12793.5.pdf additional use limitations,Installation Instructions and Created by Independent Third Party:Yes product particulars.(This product approval requires the use of"J"part number doors and sldeiltes,which have been stained or painted within 6 months of installation.) http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgSMFBcODh9X1... 7/1/2015 .............. E RMA TRU® ;��: �. THERMA TRU DOORS ------ 74.75'0.A.FRAME WIDTH I 18 INDUSTRIAL DR., 4K >n 36,0(r DOOR WIDTH a EDGERTO N, OH 4351 7 0 z :2 0 z* E0 3 M 1=1 Cc 6 CRAFTSMAN FIBERGLASS DOOR Ca a: wl FLUSH FIT GLAZING FRAME x INSWING IOUTSWING "NON-IMPACT" 3: Y GENERAL NOTES j 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Floddo Building 0 0 5W a as Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone'(HVHZ). a N JW 2. Product anchors sholl.be-as listed and spaced as shown an details;-Anchor embedment tobaseC, material shall be beyond wag dressing or stucco. 3. When used in areas requiring wind borne debris protection this product is required to be w protected With on impact resistant covering that complies with Section 1609.1.2 of the FBC. 4. For 2x stud framing construction.anchoring of these units shall be the some as that shown for 2( buck masonry construction. 5 5. Site conditions that deviate from the details of this drawing require further engineering analysis z 0 by a licensed engineer or registered architect. TABLE OF CONTENTS 22 SHEEN DESCRIPTION a I Typical elevation,design pressures&general notes DESIGN-YRdiURE fp-sip) 6 OVERAU V -2 Or I SWING STRAGAL 0 POSRIVE MYE: NIE&ATiVE 3 Horizontal cross sections DIMENSION 4 Vertical cross sections INSWING 74.75"x 82.00r STANDARD +45.0 -55.0 -5 Horizontal and vertical cross sections 6 Buck and frame anchoring 2X buck masonry construction 74 - OUTSWING 74.7S"x 81.1r STANDARD +45.0 -55.10 DATE: 6130109 7 frame anchoring I X buck masonry construction Frame anchoring direct to masonry SCALE; N.T.S. 8 COASTAL 70.0 9 Components INSWING 74.75'x 82.0or +65.0 DWG.BY: JK 2 10 Astragal details04K.W; LFS i� OUTSWING 74.76'x 81.17" COASTAL +65.0 -70.0 a II Bill of;matedals FL 1279j. a R:\Clients\Tnerma Tru PERMANENT\Florida Product Approvals1FL.t2793\Drawings%Cunem\Ft-12743.1-S.dwg,2.4 z O m , O O 79.25'DOOR HEIGHT-- O O <!�.{ O A Ob n 0OO N N O Oy O H �Z 1 bu T z m O 0 ' o 35.25' �-# �5.5" N Z -0 �m al i p'm Y DIm Z in NI>r�0 C A.2 �^3 ol( cT _ .u. e ZI 0 N rn 2 N N Gk ig nIO � � ' s m m. rs� O n M �rnM0A O N p N N Q N 0 z 30 n i► W UT' --1 OSA— �1.53, w \ 'z i W N C IA N �+ � I O LA r d y \\yyytll tit/J//// m ° p z No.43409 z.2 - c i PRODUCT: Doaumanta prepared By: -� 6TATE Of y ! F TNERMA–TRU Lyndon F. Schmidt 'ir '•.;2bR..... Iti j i FIBERGLASS GLAZED DOOR P.E. No. 43409 Na 'zy O 2 J02 UPDATE TO 5TH ED. 2014 FOC LF5 PA T OR ASSEMOLY: ✓V BUILDING CONSU`oNO 09 UPDATE TO 2010 FOC 0Y DOOR PANEL DETAILS & pY phone No,:x813.859 9197 0, VoIrloo, Fl. 33595 REV SIO S GLAZING DETAIL FB C.A. No. 9813 Q 2009 R.W.6Un-orNn 00...'--TO two. i 0.1CIi-t3\Th.ma T.PERMANENI!Vlodda Produa Apploaal$VL-1279316,—ings\C."tVL-12793.1-S.dv,.14 -0 0 -6 IM 0 c?) Z�R) a�oeaac > 05 > 0moray > Z 14 c* 00 ac,1 :Em M +rn 0 0 z Z O n' 0 0 .n. ga go -4 %4 co 0 z 00 X M m v 0 0 m .4 co rn X rtl 1\i m PO 0 No.43409 A To x oPRODUCT 0--t.P-po-d Sr. StVKOF p A THERMA TRU Lyndon F. Schmidt ...... ZED DOOR P.E. No. 43409 FIBERGLASS GLA "'1" 014 1111)! L5555\ UPDATE TO 5TH ED. (2014) FSC CFS PART OR ASSEMBLY: ' -n ILDING CONSULTANTS, I in By W� pPhouno No.: 813.85.. Box 230, Valrica, FL 33595 UPDATE TO 2010 FBC JK HORIZONTAL 9.9197 DATE CROSS SECTIONS FBPE C.A. No. 981 REVISIONS 3 RAClientsXlherma Tru PEBMANEN71FIadda Product Approvals\FL-127931Drawings\CurrentVL-12793.1.5.dwg.4A 1.114"MIN. EMB.(TYP.) M co w ° e , C'SINK ° (TYP.) 2-04 n •� • m m 'X M O � O 5'y Ja m v n ° C05 0G;0 a O •° ?m Q 3= o 1-114"MIN. o EMB.(TYP.) 0 4 1.114"MIN. EMS.(TYP.)MIN. EMB (TTP.) EMB. � X _ M ¢ �m M vP ♦ �+ A O ♦ a �O /v y 09 A A A N � `J o♦ e to v CC j. to C fT °P °n n 70 70 m o (0 x i ♦°o 2 ° Z D o Im m r� No.43409 �c Z•4.is-- '{�' Q PRODUCT: 0acumanta Prep—d By. r, •., BTASHOF 2 7 r THERMA-TRU Lyndon F. Schmid! r'"i� ;.0FdO. FIBERGLASS GLAZED ODOR P.E. No. 43409 `;` o !1! ll o to y O to 2 2 02 15 UPRATE 7O 5TH E0. 20l-0 F$C LFS PART OR A55EMBLY: GI}�//�//BUILDING CONSULTANTS,I til (y a fi N NO 2DATE 12 UPDATE 70 2010 FBC 8Y VERTICAL G/�+'u phona Na230, Vairlac,813.859 g\gry 33595 REVISIONS CROSS SECTIONS FBPn C.A. No. 9813 (1)2009 R.W.SUILDIND CONBULTANTa INC. WvClientskTha Tru PERMANENI\Florida Product App,—IskFL-12793\DtaMngs\C.,,ent\FL-12793.1-5,dwg,5.4 m X m m m 05 O;n 7b io :30 33 CoZ-O C) 3 3:Z z N. MIN. 4-— I.YMAX. n z 4 0 im 2� imm 10 m m CA m R m 1 24 0 0 IM zI/,rl MIN. " B-(TYP.) 77 X im X m n m X 91 d'6 UR C) 0 z im 0 22 z 0 4 11J4'MIN. NNN EMB.(TYP.) \\% c .F............. No.4 S.z-'s PRODUCT: 0—m-la Pmponsd By. 3 9 THEWF. A TRU Lyndon F Schmidt . M Idt ..... Atom FIBERGLASS GLAZED DOOR P.E. No. 4340 —2 2102115 2014) FBC LFS PART OR ASSEMBLY: BUILDING CONSULTANTS, I HORIZONTAL AND P 0. Box 230 Valrico, FL 33595 to 74 UPDATE TO 2010 FBC 'Ph.ma No.: 8;3.659,9197 [ED DATE -REVISIONS by I --- VERTICAL CROSS SECTIONS FBPE C.A. No, 9813 20139 R.W.SUMOING CONaUL—TO INC- a a -'---I I d o g T• 6"� � z * lel.-as—a m II rlllllltl Z d;;O II ., II SEE � � o n z TYP.HEADI I DETAIL 1 Q &JAMBS i ASTRAGAL ` (( — P E m MASONRY (� SHOWN FOR MASONRY TYP-HEAD N n o c w OPENING REFERENCE OPENING &JAMBS (( n m n o co m a n (( ASTRAGAL ,�o: S 4 a it SHOWN FOR — �' V cZ (( FRAME I I REFERENCE Q L) c l i 2X BUCK - II n25li — 28 no a v ry=x 2X BUCK I r o z I I O Q TYP.B (; SEE I I SILL — IJ �DETAlL2 — 77 c zQ -V) N rp LATCH b DEADBOLT DETAIL F w k sh Standard V! atm FRAME ANCHORING ASTRAGAL STRIKE JAMB Q. BUCK ANCHORING HINGE JAMB o! Masonry 2X buck construction n a mm K -\ K 4 A Q 27 ,? 1/7'0 78 0 N rn W O 6 CONCRETE ANCHOR NOTES: � � I. Concrete anchor locations of the corners may be adjusted to maintain the min. LATCH b DEcuifty DE7Aft o edge distance to mortar joints. Secunfy "'N g o o ce 2. Concrete onchorlocotions noted as'%v1AX-ON CENTER must be adjusted to maintain the min.edge distance to morforjoints,additional concrete anchors I 9 ° may be required to ensure the"MAX-ON CENTER"dimension are not exceeded. DETAIL DETAIL 1 4 $ 3. Concrete anchor table: Oufswing K o z h N MIN.CLEARANCE MIN.CLEARANCE L w z o ANCHOR ANCHOR MIN. TO MASONRY TO ADJACENT _ iQ n TYPE SIZE EMBEDMENT EDGE ANCNt3R =-- — 1Q10 ITW TAPCON® 1J4 ]-tJq" 7' 4" a ELCO L 1 Q J r DISE. 6/30/09 n as 1/4" 1-114" 1" 4" 0 10 10 SCAU: N.T.S. 5 ULTRACON 10 _ owc.er: ,1K m r iTW 3/16., 1.1/4" 3" 1-1/T -- --_-- TAPCON 78 — c .ar: Lf 5 3 ORAWPIG'0" E WOOD SCREW INSTALLATION NOTES DETAIL 2 HINGE DETAIL HINGE DETAIL u G ;L-12793.4 a 1.Maintain a minimum 5/8"edge distance.t"end distance,S.I"o.C-spacing of Inswing g P g Inswing Outswing °n .c wood screws to prevent the splitting of wood. s«eel 6 or 1 1 5 .......... Z< Ss f2 dZ; ............ V) Z 0 0 0 SEE oro DETAIL I a z MASONRY TYP.HEAD& 11 � OPENING JAMBS 5 ci 0 ZL C w w. FRAME ASTRAGAL 2 SHOWN FOR in z Z I I REFERENCE C-1 T fE IX BUCK 0 Go TY SILL li SEE DETAIL 2 it 1 5 az 6- HINGE JAMB FRAME ANCHORING ASTRAGAL STRIKE JAMB M o o 0 Masonry IX buck construction lax. ASTRAGAL BOLT HOLE A 1/7-0 f� Jar 10 10ti ZZ L C) z 100 DETAIL 2 7 8 �2 CONCRETE ANCHOR NOTES: (��, 21 �IEIALL 2 1.Concrete anchor locations of the corners may be adjusted to maintain the min. OutswingCa HINGE DETAIL a o � edge distance to mortar joints. Inswing Outswijng 2.Concrete onchorlocotions noted as"MAX.ON CENTER"must be adjusted to o maintain the min.edge distance to mortar joints,additional concrete anchors 25 < may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. z 3.Concrete anchor table. z MIN,CLEARANCE MIN.CLEARANCE -3 ANCHOR ANCHOR MIN. To MASONRY TO ADJACENT 10 EDGE ANCHOR .9 TYPE SIZE EMBEDMENT z L G ITWL DATE: 6130109 z 1/4- 4" - - TAPCONO SCALE: TS 10 N.7.5. ITW10 Z TAPCONG 3/16- 1-1/c 1-1/2- O.G.BY. JK 71; C"..By! LFS WOOD SCREW INSTA"TION NOTES: 1-1-0 DRAWING NO, rz 1.Maintain a minimum 518"edge distance.I"end distance,&I o.c.spacing of HINGE DETAIL wood screws to prevent the splitting of wood. UG DETAIL I InswInswingFL-12743.4 sNcEr—7or 11 .1111.1 INI, 06 z < 3" 20 F7 0 71 f2 6; SEE z 0 0 M 0 DETAIL I L, a x ZO 0 l II MASONRY TYP.@ HEAD 0 Z th V 0 a. OPENING 9 OV) z 2 DIRECT TO MASONRY TYP @JAMBS j FRAME M 6-91'16'JAMB L E 7— ASTRAGAL !--0 V SHOWN FOR SO 0 cryo — 4-9/16'IAMB H in N REFERENCE 9;z — I I DIRECT TO 5! MASONRY t Tm @ SEE 0 SILL Ii DETAIL 2 10 HINGE DETAIL A- Oulswing 252 w wti HINGE JAMB FRAMEANCHORING ASWAGAI STRIKE JAMB 1z Direct to masonry o 78 �xr 10 CONCRETE ANCHOR NOTES: 1,Concrete anchor tocotions(31 the comers may be adjusted to maintain the min. ti oLn D edge distance to mortarjoints. DETAIL I tn N ?, 2.Concrete anchor locotions noted os"MAX.ON CENTER"must be adjusted to 22 g moinfoin the min.edge distance to morlarjoints,additional concrete anchors may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. 3.Concrete anchor table: ASTRAGAL BOLT HOLE 0 1/2,0 MIN.CLEARANCE MIN.CLEARANCE ANCHOR ANCHOR MIN. I, TO MA TO ADJACENT zz z TYPE SIZE EMBEDMENT MASONRY EDGE ANCHOR ITW TAPCON6 o 1/4" 1-1/4" 2" 4- a a E ELCO DATE: 6130109 21 z 1/4" 1-1/4" 1. 47 -- ULTRACONl_ I SCALE: N.FS DIRECT TO MASONRY INSTALLATION TW 3/16- 1-1/4' 3" 1-1/2" DETAIL 2 Mo.BY., JK m Outswing c—w: LFS TAIICON- JOUTSWINQ ONLY) WOOD SCREW INSTALLATION NOTES: MAX.DESIGN PRESSURE Da NG NO.: T.Maintain a minimum 518"edge distance,I"end distance.&I"o.c.spacing of +55D PSF/-55.0 PSF wood screws to prevent the splitting of wood. FL—12 793,4 0 SHEET OF 11 2 0.1ClientATherm3 TM PERMANENT\FloHda product Approval,\FL-12793\Drawings\Curtent\FL-12793.1-S.dwg,9A -0 rh G7 0 0 IA9" 1.49- Ll 0 OL c�41 oaf 90 oma or 0.75, M. 0 3 a rbn P. 1.25" 0 5,0 0 CLO 0 SCHA/' _J , No,43409 fX PRODUCT: 0--t.P-pard Or. v SIMOF THERMA TRU Lyndon F. Schmidt AZOWNX S FIBERGLASS GLAZED P.E. No. 43409 /lp "; NAL 2UPDATE TO 5TH ED. S — PART OR ASSEMBLY: BUILDING CONSULTANTS,'IYA" UPDATE TO 2010 FBC JK BY COMPONENTS Xu(P.O. Box 230, Voirloo, FL 33595 Phone No.: 813.659.9197 REVISIONS- FBPE C.A. No. 9813 C 2009 R.W.BUILOW.a...UL--&I.C. PACrienUMenns Tru PERMANENT\Florida Product Apprmals\FL-12793\DraMngs\Cutrent\FL-12793.1-S.dwg.10.4 W01-108 93 e O 0 Com) b P b 2.68" ro 0- 2.68"— p Na.43499 r y PRODUCT: Deton.nt.PrIpored S), THERMA TRU Lyndon F. Schmidti •''"'...,...•FLOR. . FIBERGIASS OWED DOOR P.E. No. 4340B Itil CONSULTANTS,2 UPDAM TO 5TH ED. (2014) FSC LrS PART OR ASSEMBLY BUILDING LID 'i c- Pto , 0_L 2109/12 UPDATE TO 2010 FSC JK P.O. Box 230, Valrico, FL 33595 -gy— ASTRAGAL OE XW '0 NO DATE TAILS Phone No.; 813.659.9197 I REVISIONS FBPE C.A. No. 9813 0 2009 R.W.BUIL-MG CC—ULTAN—INC. BILL OF MATERIALS BILL OF MATERIALS REM DESCRIPTION MATERIAL ITEM DESCRIPTION MATERIAL A IX8UC SG>=0.55 WOOD 44 HINGE STILE LVL/WOOD AV: 0. —B -ii—BUCK SG>=0.55 WOOD 45 BOTTOM RAIL COMP. Z C MAX.114-SHIM SPACE WOOD 46 DOOR PANEL CORE FOAMED POLYURETHANE d)s z d ci D 1/4 X 23/4-PFH ELCO OR ITW CONCRETE SCREW STEEL 47 LOCK STILE LVUWOOD =%V'. - y.. E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE 48 TOP RAIL COMP. Ile ........ n 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 49 DOOR SKIN.070"MINIMUM THK.FIBERGLASS FIBERGLASS j 11 G 3/16"X 3-1/4"PFH ITW CONCRETE SCREW STEEL 78 1"ASTRAGAL STRIKE PLATE % Z> 0 0 H 1/4"x 3-1/4"PFH ITW CONCRETE SCREW STEEL 1 PFH 1!4"PFH ITW CONCRETE SCREW 1-1/4"MIN.EMBEDMENT 1 STEEL a a E a zes J 1/4"X 3-3/4! c. 'PFH ITW CONCRETE SCREW STEEL U) 6 c. 'A M K WX 2-112'PFH WOOD SCREW STEEL m C�a.L, L #10 X 2-117'PFH WOOD SCREW STEEL E lz M 3116'X 2-3/4'PFH ITW CONCRETE SCREW STEEL v tj N 3116'X2-1/4"PFH ITW CONCRETE SCREW STEEL S d I EXTERIORLITEFRAME ALUM. 2 INTERIOR LITE FRAME ALUM. 3 LITE FRAME TRIM PVC 4 #IoX 1-1/7'PFH SM SCREW STEEL 7 MEDIUM REACH COMPRESSION WEATHERSTRIP FOAM 8 LONG REACH COMPRESSION WEATHERSTRIP FOAM 9 4'X 4!'HINGE.097'THK. STEEL uj(n :F 10 #10 X 3/401 PFH WOOD SCREW STEEL it H 10 X 1-1/2-PFH SCREW STEEL Q: 2 I #IQX 7'PFH WOOD SCREW STEEL an 14 THRESHOLD OUTSWING-SELF ADJUST ALUM./COMP. 15 THRESHOLD OUTSWING-5-3/4"COMPOSITE SILL ALUM./COMP. 16 THRESHOLD OUTSWING-5-3/4'COMPOSITE SILL ALUM./COMP. m 17 PASSAGE LOCK-KWIKSET SIGNATURE SERIES STEEL 18 THRESHOLD OUTSWING 5-3/4"THERMAL BREAK SILL ALUM./WOOD -Tq­HEADERJAMiSG>=0.42 WOOD -fO--§I-DE JAMB—SG 1-0.42 WOOD 21 DEADBOLT KWIKSET SIGNATURE SERIES(980) STEEL U) CS E2 z 22 ASTRAGAL—(COASTAL) ALUMINUM w 0 23 ASTRAGAL FLUSH BOLT STEEL 24 -ASTRAGAL FLUSH BOLT RETAINER ALUMINUM 2 2 25 ASTRAGAL(STANDARD) ALUMINUM _27--D�TCH—STRIKE PLATE STEEL 0.OL 8 STANDARD DEADBOLT STRIKE PLATE STEEL 30 SECURITY STRIKE PLATE STEEL z 31 COASTAL OUTSWING THRESHOLDALUM./WOOD --32 -do—oR aoT-rom SWEEP PVC 33 INSWING ADJUSTABLE THRESHOLD ALUM./COMP. z -34- OUTSWING THRESHOLD-5-3/4-HARDWOOD SILL ALUM./WOOD z6130109 36 INSWING THRESHOLD-FIXED ALUM./COMP. SCALE: N.T.S. 37 OUTSWING THRESHOLD ALUM./COMP. 38 INSWING ADJUSTABLE THRESHOLD ALUM./COMP, DWG.M JK. 40 FIBERGLASS DOOR PANEL CRAFTSMAN FIBERGLASS CNKBY: LFS 43 LOCK BLOCK REINFORCEMENT WOOD DRAWING NO, 15 FL--12793.4 ca 5 5 SHEET r 1 OF 11