HomeMy WebLinkAboutEngineering L, PARADISE X "Building Our Quality Reputation One Customer At A Time SCC131150472 Property Information 8WI&g Information Owner: Prakash&Diane Maharaj Wind Zone: 170 MPH. Address: 400 SW Airoso Blvd Exposure Category: C Port St Lucie,FL 34983 Minimum Building Dimension: 27 ft. Mean Roof Height: 12 ft. R Jet Risk Category:I II I ;.I Design Pressure Calculations Opening Location Device Device DeviceIF Max Positive Max Negative Number Zone IF Width(in) Height(in) Elevation(ft) (Pressure(psf) Pressure(psf) 1 Int 35 37 7 -�_;I -37.8 -41.0 2 Int 35 37 7 37.8 41.0 3 Int 25 24 7 37.8 41.0 4 Int 35 49 7 37.4 40.6 — --- ..... _ .... .- ..... --- -- - ._. .... ... .......----- --- 5 Int 51 36 7 37.2 40.4 — --- ..-_.............- ---.....-............--- —--- -----...-._...._._....- - -_............ -- - 6 Int 51 36 7 !, 37.2 -40.4 --- ---................................-- -_....-..........._._.. _- _.............._.....-----...-....._...._-.... - - ...............---- - 7 Int 51 36 ............... -----.-._. __.7 ___; i 37.2 -40.4 8 Int 51 36 _ _ 7 i 37.2 -40.4 9 End 35 24 7 j 37.8 -50.6 10 Int 36 80 7 36.1 -39.3 I d it i I I I � I j Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.5thEdit*I(2014)Florida Building Code. Page 1 of 1 II .''- ' WINDOW & DOOR OPENING INFORMATION A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE OPENING (Location) IS THIS A PRODUCT ROUGH ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE TESTED MULLION ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF SIZE DIMENSIONS REQ Y/N REQ Y/NINA 1 Int window 7/8"Lami FL16177.1 70 70 37.8 -41.0 52x62 35x37 No No 2_— Int- window- 7/8"Lami- FL161.77.1- 70 70 37.8 -41.0 52x62 3507 No No - 3 Int window 7/8"Lami FL16177.1 70 70 37.8 -41.0 52x62 25x24 No No _ window 7/8"LamiFL16177.1 ___ 70 _ 70 37.4_ -40.6--- -x62 _35x49 _ No _ No 5 Int window 7/8"Lami FL16177.1 70 70 37.2 -40.4 52x62 51x36 No No 6 Int window 7/8"Lami FL16177.1 70 70 37.2 -40.4 52x62 51x36 No No 7 Int window 7/8"Lami FL16177.1 70 70 37.2 -40.4 52x62 51x36 No No 8 Int window 7/8"Lami FL16177.1 70 70 37.2 -40.4 52x62 51x36 No No 9 End window 7/8"Lami FL16177.1, 70 70 37.8 -50.6 52x62 35x24 No No 10 Int 36.1 -39.3 36x80