Property Information 8WI&g Information
Owner: Prakash&Diane Maharaj Wind Zone: 170 MPH.
Address: 400 SW Airoso Blvd Exposure Category: C
Port St Lucie,FL 34983 Minimum Building Dimension: 27 ft.
Mean Roof Height: 12 ft.
R Jet Risk Category:I II
I ;.I
Design Pressure Calculations
Opening Location Device Device DeviceIF Max Positive Max Negative
Number Zone IF Width(in) Height(in) Elevation(ft) (Pressure(psf) Pressure(psf)
1 Int 35 37 7 -�_;I -37.8 -41.0
2 Int 35 37 7 37.8 41.0
3 Int 25 24 7 37.8 41.0
4 Int 35 49 7 37.4 40.6
— --- ..... _ .... .- ..... --- -- - ._. .... ... .......----- ---
5 Int 51 36 7 37.2 40.4
— --- ..-_.............- ---.....-............--- —--- -----...-._...._._....- - -_............
-- -
6 Int 51 36 7 !, 37.2 -40.4
--- ---................................-- -_....-..........._._.. _- _.............._.....-----...-....._...._-.... - - ...............---- -
7 Int 51 36 ............... -----.-._. __.7 ___; i 37.2 -40.4
8 Int 51 36 _ _ 7 i 37.2 -40.4
9 End 35 24 7 j 37.8 -50.6
10 Int 36 80 7 36.1 -39.3
I
d
it
i I
I
I �
I j
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.5thEdit*I(2014)Florida Building Code.
Page 1 of 1
II
.''- ' WINDOW & DOOR OPENING INFORMATION
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE
OPENING (Location) IS THIS A PRODUCT ROUGH ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE TESTED MULLION ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF SIZE DIMENSIONS REQ Y/N
REQ Y/NINA
1 Int window 7/8"Lami FL16177.1 70 70 37.8 -41.0 52x62 35x37 No No
2_— Int- window- 7/8"Lami- FL161.77.1- 70 70 37.8 -41.0 52x62 3507 No No -
3 Int window 7/8"Lami FL16177.1 70 70 37.8 -41.0 52x62 25x24 No No _
window 7/8"LamiFL16177.1 ___ 70 _ 70 37.4_ -40.6--- -x62 _35x49 _ No _ No
5 Int window 7/8"Lami FL16177.1 70 70 37.2 -40.4 52x62 51x36 No No
6 Int window 7/8"Lami FL16177.1 70 70 37.2 -40.4 52x62 51x36 No No
7 Int window 7/8"Lami FL16177.1 70 70 37.2 -40.4 52x62 51x36 No No
8 Int window 7/8"Lami FL16177.1 70 70 37.2 -40.4 52x62 51x36 No No
9 End window 7/8"Lami FL16177.1, 70 70 37.8 -50.6 52x62 35x24 No No
10 Int 36.1 -39.3 36x80