HomeMy WebLinkAboutMisc Letters i CREEK Certificate of AuthorizationVo. 29824 17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT 2014 FLORIDA BUILDING CODE Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued April 13, 2015 P.O. Box 1404 Joplin, MO 64802 (417)624-6644 httr)://www.tamko.com i Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.2.3, 1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5.1, 1507.4.5.2, 1507.4.5.3, 1507.5.3, 1507.5.3.2, 1507.6.3, 1507.6.3.2, 1507.6.5, 1507.7.3 1 1507.7.3.2, 1507.8.3, 1507.8.3.2, 1507.8.8,T1507.8, 1507.9.3, 1507.9.3.2,'1507.9.5,1507.9.9 Properties: Physical properties REFERENCES En& Report No. Standard Year PRI Construction Materials Technologies(TST6049) TAP-191-02-01 REV ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2005e01 PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 2261 2006 PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2009) PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2009) PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 2261 2006 PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2006 PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2009) PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2005e01 UL LLC(TST9628) 13CA12269 ASTM D 226 2006 PRODUCT DESCRIPTION AND APPLICATION I TAMKOS ASTM Slate ASTM D 6380, Class M,Type II underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. Min.slope: 2:12 ,I Application: The underlayment shall be installed with minimum 2° side laps and minimum 4"istaggered end laps and in accordance with FRSA/TRI 07230 for file applications. Allowable roof coverings: Attachment of asphalt shingle valleys and clay and concrete the shall be permitted in accordance with the FBC. TBP14001.1 FL12328-R5 I Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. i 'I TAMKO BUILDING PRODCUTS,INC. CREEK TAMKO Underlayments TECHNICAL SERVICES,LLC TAMKO®ASTM Tile ASTM D 6380, Class M,Type II underlayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. Application: The underlayment shall be;installed with minimum 2" side laps and minimum 4°staggered end laps and in accordance with FRSA/TRI 07230 for the applications. Allowable roof coverings: Attachment of clay and concrete tile shall be permitted in accordance with the FBC. TAMKO®Master ASTM D 6380,Class S,Type IV underlayment constructed from an organic felt saturated Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. Application: The underlayment shall be installed along the valley in accordance with FBC requirements. Allowable roof coverings: Attachment of asphalt shingle valleys shall be permitted in accordance wii h the FBC. TAMKO®Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified,bitumen sheet membrane Guard Plus® with a mineral surfacing and a removable release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the roof deck with minimum 3-1/2" side laps and minimum 6°staggered end laps. Min. application temperature: 40°F. Allowable roof coverings: Attachment of asphalt shingles and mechanically fastened concrete and clay the roofing shall be permitted in accoirdance with the FBC. TAMKO®No. 15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4°'end laps. Allowable roof coverings: Attachment of asphalt shi'I gles, metal roofing, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKO®No.15 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt. Application: The underlayment shall be installed with minimum 2° side laps and minimum 4",end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, wood shingles, wood 'shakes, and roll roofing shall be permitted in accordancewith the FBC. TBP14001.1 FI-12328-R5 Page 2 of This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or otherproduct attributes that are not specifically addressed herein. I DEEK TAMKO BUILDING PRODCUTS,INC. j'Z I TAMKO Underlayments TECHNICAL SERVICES,LLC TAMKO®No.30 ASTM ASTM D 226,Type If underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt Application: The underlayment shall be'installed with minimum 2" side laps and minimum 4"end laps. Allowable roof coverings: Attachment of as shi lgles, metal roofing, clay and concrete file', slate shingles, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKO®No.30 UL ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"end laps. Allowable roof coverings: Attachment of as shingles, metal roofing, clay and concrete tile, slate ;shingles, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKO®TW Metal and Self-adhered, flexible, ASTM D 1970, rubberized asphalt ;sheet membrane with a Tile Underlayment polymer film on the surface and a removable release,film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the roof deck with minimum 4" side laps and minimum 6"staggered)end laps. Min.application temperature: 40°F Allowable roof coverings: Attachment of asphalt shingles, metal roofing, and mechanically fastened clay and concrete tiles shall be permitted in accordance with the FBC. TAMKO®TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt,',sheet membrane with a Underlayment polymer film on the surface and a removable release film on thi adhesive side. Application: The underlayment shall 'be attached by adhering directly to the roof deck with minimum 4" side laps and minimum 6"staggered end laps. Min. application temperature: 40°F Allowable roof coverings: Attachment of asphalt shingles and metal roofing shall be permitted in accordance with the FBC. I I i I TBP14001.1 FL12328-R5 Page 3 of This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. 11 This evaluation report does not express nor imply warranty,installation, recommended use,or otherproduct attributes that are not specifically addressed herein. i TAMKO BIUILDING PRODCUTS,INC. CREEK TAMKO Underlayments TECHNICAL SERVICES,LLC LIMITATIONS I' I 1) This evaluation report is not for use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report,the FBC,and the'manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 1 11 5) Minimum application temperature shall be 50°F unless otherwise noted. Contact the manufacturer when installing at temperatures below the minimum application temperature. l 6) Deck substrates shall be clean, dry, and free from any irregularities and debris. I All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 7) The roof deck shall be constructed of closely fitted sheathing for newor existing construction. Roof deck shall be installed in accordance with FBC requirements. 8) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements. 9) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in successive courses installed up the deck in a manner that effectively, sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 10) The underlayment may be used as described in other current FBC product approval documents. 11) The underlayment shall not be installed over existing roof coverings. 12) Contact the manufacturer regarding specific exposure limits for each underlayment. 13) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT I The products evaluated herein by Zachary R. Priest, P.E. have demonstrated'compliance with the 2014 Florida Building Code as evidenced in the referenced documents submitted by the named)manufacturer. %, R. `,�����i a .,��,��Q`�•. Rc r� J, 2015.04.1 G� ENS ,d.0 3 09.06.05 No 74021 -04'00' STATE OF '#- p ,:_ Zachary R. Priest,,P.E. '��,�`•'•� O R ��•• �jN�.` Florida Registration No.74021 Organization No.ANE 9641 i CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing'or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing'products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. I 'I Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval"process of the product. END OF REPORT TBP14001.1 FL12328-R5 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein.