Loading...
HomeMy WebLinkAboutProduct Review Affidavit 0 e sto ulf II SUPPLY & MANUFACTURING TM d ULFRIB 26 GUAGE GULFRIBTM PANEL OVER • •D A FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 TM t Product Evaluation Report GULF COAST SUPPLY& MANUFACTURING, d"C 26 Ga. GulfRibTm Roof Panel over 15132"P/ywood 1. II Florida Product Approval #11651.22 R2 i. Florida Building Code 2014 Per Rule 61 G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61 G20-3.005(1)'(d) NON HVHZ Product Manufacturer: ; Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 Engineer Evaluator: = NO, 7551 Dan Kuhn, P.E. #75519 - r' Florida Evaluation ANE ID: 10743 STA7-EOF ••Q, ..p .c 4 . Validator: OA/AL ENG0 Locke Bowden, P.E. #49704 A "' 9450 Alysbury Place 06�3 �5 Montgomery, AL 36117 Contents: Evaluation Report Pages 1 — 51, FL#11651.22 R2•JUNE 15,2015 000 GuIfCoaKt SUPPLY &MANUFACTURING GULFRH8dTM 26 GUAGE GULFRIBTM PANEL OVER • •D FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 TM ii I Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. i Product Description: GulfRibTM, 3/" Rib Roof Panel, Minimum 26Ga. Steel, 36" Coverage, through fastened roof panel over minimum115/32" Plywood Decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2014 Section 1507.43. Paint Finish Optional Yield Strength: Min. 80.Oksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2014, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 36" Coverage Rib Height: 3/" Major Rib at 9" O.C. Panel Fastener: #9-15x1.5" HWH with sealing washing oriapprovetl equal A" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15/32" thick,APA Rated plywood over suppl its at maximum 24" O.C. Design of plywood and plywood.supports are outside the scope of this evaluation. Must be designed in accordance w/Florida;Building Code 2014. Design Uplift Pressures: Table"A" IVI'auumTotal Upl ftDesg�nPressure [69,25 ps 9,2-5 p Fastener Pattern 9;--9--9--9- 6.5"-2.5"-6.5"- 2.5"6.5"-2.5"-6.5" .5"-2.5"-6.5"- 2.5"6.5"-2.5"-6.5" Fastener PLatterin Spaci 46�' `` • d Design Pressure includes a Safety Factor= 2.0. FL# 11651.22 R2•JUNE 15,2015 o . ® ® �CT�WAUs ENGINEERING,KUHN Gulfca�Nt SUPPLY & MANUFACTURING [STMGULF [RH ■ GLIAGE GULFRIBTM PANEL OVER • • FLORIDA PRODUCT APPROVAL NO 11651.22 I' TM Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06-Test for Uplift Resistance of Roof Assemblies • UL 1897-04- Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94/ 1897-98 Uplift Test Force Engineering &Testing, Inc. (TIBC Orga�ization #TST 5328) Report No. 117-0062T-07A, B, Dated 02/19/2007 2. Certificate of Independence By Dan Kuhn, P.E. (FL#75519)@ Kuhn Engineering, LLC (FBC Organization #ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code land Rule!61 G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be l sed in tAe panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2. i FL#11651.22 R2•JUNE 15,2015 .P—R,® ®U ICT.- a e 11.670 .ISLAND LAKES LANE. BOCA RATON, • #30464 I� 00 .4 GUIK5�& SUPPLY & MANUFACTURING GULFRIBTM • GUAGE GULFRIBTM PANEL OVER • • FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 TM ! i Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table,fastening pattern must at a minimum meet those listed for the applicable,;wind zone. For all roofs outside the parameters listed on the load table, design wirrtl loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design.The maximum fastener spacing listed herein shall not be exceeded.This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. �I I it I ' I i I I it I I� FL#11651.22R2•JUNE 15,2015 I • I '00� • ID GulfNf SUPPLY & MANUFACTURING TI GU ,LFR-'IB Q, 26 GUAGE GULFRIBTm PANEL OVER • •D FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 TM ' I 1 ENGINEER LOAD TABLE:26 Ga. GulfRibTM Panel over 15132" Plywood Buildings ha�ing Roof Mean Height<20 X03' Roof Slope s2 /1 Z 12,/12� G�b(W@2, Roof;llUirid P-4--h- 14 1 SOrl1 h Ex osure C Rls{c Cate i� II Enclosed Bulldir3y based qn;FlQnda Bu°Ildinq14. F 120 130 140 150 11160 170 180 WIND FASTENER SUBSTRATE SPEED (MIN. do (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING I .I p�xZCINE 1 #� 15x1 5 PlywoOdz - 24 STYPE 1 24'�TYPE 1� 24 TYPE 1 24 TYPE 7 24;,TYPE 1'� 24�sTY,PE�1 24 `°rYPE 1 21 ONE 2 #9-15x1.5" Ply wood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24 ,TYPE 1 24",TYPE 1 12",TYPE 2 tPI Zt7NE 3 #9 15x1 5 Plywood"4 "24TYE 1 24' TYPE 1 4'- TYPE 1{ z12" TYPE Z 1-21', TYPE 2' 12 ^TYPE 2 j 12 TYPE 2y 1.)PANEL DESCRIPTION: GULFRIBTM, MIN. 26 GA., GRADE 80,36"COVERAGE,3/4"TALL.! 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL j 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:69.25 PSF @ 24" O.C. FASTENER jSPACING,TYPE I FASTENER PATTERN, 159.25 PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 18VTESTING. 4.)PLYWOOD DECKING: MIN.15/a2"THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014. 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85) MULTIPLIEDi BY 0.6 PER FLORIDA BUILDING CODE 2014 zONE2 RIP ROOF a Note:Dimension(a)is defined as 10%of the minimum width of the building or . ZONE 3 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be LIZONE --------, a building or 3 feet. a less than either 4%of the minimum width of th / /1 TYPE 1 FASTENER PATTERN GE —J // PanelLap -- 1L Cont.Tape Seal for use on Slopes less than 3:12 -------- 24'O.C.Max. (1)#9-15x1-112'w/Sealer Washer@VE TYPE 2 FASTENER PATTERN ZONE 2 GABLE ROOFa 1 —�— ----------------- � a {-6.5"—{2.5" 6.5'—{2.5" 6.5'—{2.5' {-6.5"—{2.5° / I d RIDGE L Cont.Tape Seal for use on Slopes less than 3:12 I ---_— — (1)#9-15x1-112°w/Sealer washer @11YO.C.Max. +---------------------4a i ZONE �-----------------------F ZONES EAS FL#11651.22 R2•JUNE 15,2015 I KUHN ENGINEERING, LLC 1 RI NG U F 4cT TJ a � oil Walk SonN 77 t „a r t titk al 0011,**_', N_ e.... JLFRIBTm DETAIL MANUALGulf Loast fORtrTERLY KNOWfJ AS TUFF-RIB SUPPLY & MANUFACTURING The Gulf Coast Tuff-Rib® Roofing Panel Gulf Coast Tuff-rib®panels are a strong, durable, economic, and attractive answer to the growing demand for metal roofing needs Y in Florida and southern Georgia. Extremely versatile they are suitable for homes and f G § ` businesses as well as agricultural and utility buildings Tuff-rib®panels provide a 36-inch coverage with 3/4 inch ribs on nine-inch k centers, and utilize an anti-siphoning channel to provide protection from severe weather Figure 9 The Gulf Coast Supply office (left)and manu- �, , -- facturing facility. conditions. Both panels and trim are fabricated using state-of-the-art computerized equipment at our facility >A aaZ near Horseshoe Beach Florida to assure unifor- aa"d i t °� �' i mity and consistency in product manufacture. and 1-to N sranco,d ; Panels are roll-formed to the lengths specified by customers in either Galvalume or any ofa more than twenty colors of painted 29-gauge, 26-gauge, and 24-gauge high-tensile metal, ready for either customer pickup or on-site 19 �`�� s� 26 ` delivery (customers should call about Gul/ol Trento - availability of 24-gauge metal). Your Gulf Mexico ` a ola Coast representative is waiting to assist youawn 19 51 Ghdetland in making the best choice for your particular Gulf Oast rseshoe roofing needs. . supply Bea�n�i 27 Gulf Coast's Tuff-rib®panels are 14 mil of south Figure 2 Location of Gulf Coast Supply fabricated from AZ-50 (painted) orAZ-55 c1o35 Cityg pP Y (bare Galvalume) grade 80 coil stock(grade 50 for 24 gauge). The bare Galvalume finish is not only durable and cost effective, but offers reflectivity so valuable here in the South. The paint system 1 employed on painted products offers optimum exterior protection plus superior resistance to corrosion and ultraviolet radiation. Figure 3 The Tuff-rib panel I�-9 While bare Galvalume carries a 25-year limited coil manufacturer's finish warranty, most painted metal carries a 40-year warranty. Both painted and unpainted are of the highest known quality in the industry. Gulf Coast also stocks a complete line of fasteners, sealants, and other accessories to meet every need of both the do-it-yourself homeowner and the roofing contractor. A complete line of both in-stock and custom-made flashings and trims are available in all colors as well. o . . . GULHi DETAIL MANUAL GuIfCo�gf FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING I I Installation of Panels Roof Pitch Gulf Coast roofing panels require a certain degree of pitch to ensure proper water drainage. Florida Building Code allows a minimum pitch of 2/12 for off--ribi panels as long as lap screws and sealant are applied to the laps to prevent water from siphoning over the ribs (see Fig. S on p. 4). Lap screws and sealant are optional when the pitch is 4/12 or greater(4%12 pitch means that there is 4 inches of rise for every 12 inches running horizontally). As a general principle, the less steep the roof, and the more necessary also that sealant be used at all side-laps. Consult our representative for recommendations for your particular roof pitch, and about roofing options if you have less than a 2/12 pitch. Roof Preparation Oil-canning is a wave-like,rippled appearance extending up the length of the panel after it has been installed on the roof. Any irregularities in the roof, including uneven plywood joints, warped plywood,uneven trusses,poor application of underlayment,the use of button caps with felt paper, etc., can promote oil-canning. Care should be taken to provide a flat, uniform surface on which to attach the panels. See page 6 for more details. 1 Roof Application Panel installation should begin at the gable end of the roof opposite the'prevailing rain-bearing wind(this will provide added assurance against win&driven rain being forced,under the laps). Measure one panel width in from the roof edge. At this point chalk a line from ridge to'�eave. Place the leading edge of the first panel along this line. It is extremely important that this panel be laid square to the eave and ridge so that the remaining panels will line up square on the roof frarne. Itis wise to have a person at the eave and at the ridge to ensure that the proper panel coverage is being maintained across the roof. Also be sure that the panels are properly side-lapped(see fig. 7 on page 7). In applications where end-lapping is necessary, the upper panel.on the;slope should lap over the panel that is lower on the slope by about 12 inches. Lesser roof pitches require a greater amount of panel.overlap. All end-lap applications should use two horizontal row's of butyl sealant tape across the panel and proper fastening to provide a maximum water seal. An overhang of 2 to 3 inches on the eave is recommended to provide al drip edge,while only 1 inch overhang is necessary where gutters are used. The open panel rib's at the,cave can be sealed with inside closures. For maximum weather-tightness, a row of butyl tape can be applied above and beneath closure material. Trimming and Cutting Steel Panels The best device for cutting steel panels across the profile is either hand snips or a nibbler. Nibblers, and especially Carborundum blades on electric saws,.however, do have a tendency to either leave hot metal particles that can burn paint surfaces or to leave rust marks or 'panels and trim. The same is true of any filings left on the roof caused by the application of screws: Care should be taken to brush all such particles from roof surfaces after application. To cut panels lengthwise: Note carefully where the panel is to;be cut, and,using a straightedge, score deeply down the length of the panel with a sharp:pointed utility knife. Folding the panel along the score mark, and bending back again if necessary, should produce a clean break in the panel. "CAUTION! clean allmetal shavings and particles off of roof to avoid unsightly rust stains 11(808) 393-0335 FAX(352)498-7952 WWW.GulfCoastsupply.com 3 i DETAIL MANUAL GuIK5ans FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING Residential Trim Seep. 12 for Siding Trinzs Valley edge cap Endwall Gable trim flashing Sidewall Fla'-Oitin,g • _ � gay�'I�'�vCJ" �3�, F J1 y 6 F ' w aye£i�rip Yff1 (� (p• 8) r S'•. `FRS t .' .r Panel lap detail Roll Lite Door Lap Screw Apply sealant ,. to lap overlap�� Transition _. ___-- - �Fl"ashing urp. .hn-beann g le g. l decl >ng_. (p.10) y � Figure 5 Butyl tape or caulk is required when the roof pitch is 3/12 or less, with lap screws applied every 2 feet to maintain water-tightness of the lap. On pitches greater than 3/12,lap screws and butyl Figure 4 Roofing trims and flashings are named by the tape are optional. For more details on screws, location or function of that particular piece on the building. see pgs.6 and 7. 39.1.0335 FAX(352)49,8-7952 -wvvW.GulfCoast5upp1y-com I I ,J u ULFRI} : . . U11 %.oasx FORMERLY KNOWN AS TUFF-RiS S U'P P LY & MANUFACTURING Ordering Roof Panels and Screws I Care should be taken to order panels of the correct length toy avoid having to make corrective measures after purchase. Panel lengths should fall 2 to 3 inchesf short of the ridge-when a vented ridge is desired, and should extend 2 to 3 inches past the eave to''allow a sufficient drip edge (except as noted on pg. 3 concerning gutters). When a roof transition is involved,panels of the upper portion should be ordered short to allow placement of the transition flashing (see diagram on p. 10). The Gulf Coast sales personnel are ready to assist customers with information specific to their particular roof. ' Specially-washered screws applied through the flat of the in is the most recommended method used to attach roofing panels. 1-inch screws can be used if penetration of only 3/a inch is either necessary or desired; otherwise, 1'/z inch screws are usually recommended. 2'/Z inch screws are also available, and are often used by those who adhere to through-the-rib fastening, and for ridge-cap application. See pages 6 and 7 for more information on screw spacing and ordering. i, Ordering and Applying Trim i The most common flashing for metal roofing is the ridge cap,which is used at the peak of a roof where two opposing roof slopes join. Other flashings include transition flashing, end wall and sidewall flashings, and valleys (see diagram on right for application). ;Eave trims include gable flashing and eave drip, either of which are often applied above fascia trim. When roof pitch exceeds 5/12 (a 5 inch rise in 12 inches), the slope of the roof should be mentioned when ordering ridge caps, endwalls, and eave drip. When a steeper roof slope meets a lesser slope, both slopes should be mentioned when ordering transition flashing. At the gable edge the use of gable trim adds to the appearance of the structure and protects the fly-rafter, and sidewall flashing is used where the side of a panel butts up against an adjacent wall. In either case, the installer should be careful to seal betweeni the gable rake or sidewall and panel with butyl sealant tape, and to fasten the rake every 6" to 12", up the slope of the roof with the appropriate screws. If eave drip is used on the gable, the number of 90 degree eave drip should be specified separately from that used on the drip edge when ordering. To prevent penetration of water, insects,-and debris at the ridge, outside closures should be inserted between the ridge cap and the top end of the panel. Screw's are applied through the ridge cap, closure, and rib in at least every other rib of the panels. At least a 11/2" (or preferably 21/2") screw should be used for attaching ridge caps. Self-drilling lap screws can also be used to attach ridge caps. Keep Materials Dry? Paint and finishes of Gulf Coast panels and trim are designed to with,'Jtand severe rain and wet weather conditions. Neither paint, galvanized, or Galvalume finishes, however, are designed to be in continuous contact with water for long periods of time. Damage will result if uninstalled panels or trim are allowed to remain wet in storage. Be sure to store material that will not be installed immediately in a dry location. Wet material should be air-dried and re-stacked if installation is not planned right away. 4(888) 393-0315, PAx(352)498-7852 WVVW.GU1fC-0aStSUpp1y.00rh i 000, all GULFRIB Tm DETAIL MANUAL GuIfCoasf T- FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING How to Figure and Apply Screws Screw( urlin)Spacing PP Y 92 inch 18 inch:24 inch ' b 50,; 270 180:. 135 �� Gulf Coast Supply carries screws in 3 different lengths: 1 inch, 1% 100 540 360 1 270 inch, and 2 '/Z inch. 1-inch screws will barely penetrate a 1x4,but the o 200 1080 720,.: 540 V/z inch are the best all-purpose size. 1'h-or 2'/Z-inch screws are 300 1620 1080 810 necessary for attaching ridge caps. The table on the right can be 400 2160 1440 1080 500"°'2700` 1800 1350 used to figure approximate quantities of screws for various purlin W ,;600 3240 2160 1 1620 spacings and sizes of roofs. For 2-foot spacing between rows of o 700 3780 '2520 1890 screws,multiply the total linear feet of metal times 2.7 8 800 4320 2880: 2160 `~ ExamTuff -rib your order is 1250 feet of Tu -rib roofing. 900 -4.860 - 3240 11 243911 --24 1000 -5400 3600 2700 . 1250 x 2.7=3375 screws - ,;.. Please confirm all estimates with our Gulf Coast representative when 1100 5940 3960? 2970 y p 12001 6480 __4320 3240 you placed your order. Figure 6 Tuff rlb.panel screw Codes allow re-roofingover shingles without the use of battens l6 g calculation chart provided the roof has been checked by a licensed roofing contractor to insure levelness and pullout integrity. Tuff-rib metal roofing can be separated from the moisture barrier by minimum,nominal 1"x3" yellow pine battens spaced on maximum 24"centers, or according to ASCE calculations where applicable. Since direct contact between pressure treated lumber and metal roofing must be avoided in order to prevent potential corrosion, Gulf Coast Supply sells only untreated battens. CAUTION: Battens must be fastened to the roof deck with minimum#6 screws at 12" on-center, or two minimum 8d common or pneumatic nails spaced 8" on-center, or one every 4" on-center(or by applicable calculations according to ASCE 7-98). Battens must be installed to support the entire width and length of ridge, eave, hip,valley,and gable-end trims. For solid decking, at least 15/32-inch structural plywood supported on rafters at a maximum of 24" on center is required. If care is taken,metal roofing application can be aided by pre-drilling panels, allowing screws to go quickly and accurately into the desired spacing. Pre-drilling will work provided that pilot holes are placed accurately in the proper locations on panels. Purlin spacing must be uniform and carefully measured. For panel lap details, see Figure S on page 4. Gulf Coast Policies Delivery policy Delivery charges apply to all orders where delivery is requested. Please consult your Gulf Coast sales department for details. Sales tax All orders picked up at Gulf Coast Supply,and all orders delivered within the state of Florida, are subject to state sales tax. Tax exemptions should be verified prior to delivery or customer pickup. Warrantied products A 40 year warranty applies to most material` manufactured from painted coil stock,and a 25-year warranty to Galvalume material.Ask for details. Indemnity All prices and designs are subject to change without notice Disclaimer While we have made every attempt at accuracy in this manual,we are not responsible for typographic, printing, or technical errors. Oil Canning—a repeating,wave-like appearance in the length of the panel—is a common and often unavoidable phenomenon in metal panels like Tuff-rib roofing that have large,flat areas within the panel. It is therefore not a defect,nor a cause for rejection. See p. 3 for details on how to avoid oil-canning. Return policy All panel orders and special order(non-stock)trim are considered the property of the customer and non-refundable once they are manufactured. Standard trim and accessories are refundable providing they are returned in a clean,resalable condition. Restocking charges will apply to any items at the discretion of the Gulf Coast representative. I j ( BTm DETAIL MANUALIf C 010ne *- FORMERLY KNOWN AS TUFF-RIB OU P P LY & MANUFACTURING i Gulf Coast Tuff-Rib® Roofing Panels SECTION PROPERTIES ALLO"I 13LE LOADS(PSF) Fli � 'F Lige'=Load Live Load Ix din Sx In' Ix In Sx M Wind Load s Panel, Fy ThicknessKSI r Weight firth. (Stress) (Deflection)', '6a'uge KSI In. Pos. Neg PSF In _-PositivBend ng 2 21-6- 3(( ; 4 6 3' 3'6 4'r 2. 2-6' 3 TVA' —Bending 26 ga. 80 .0187 36 36 .91 42 0288 0482 .0288.1892 170 109 76 56 42 128 82 57 42 32 102 52 30 19[ 13 29 ga. 80 .0142 36 36 .69 40.875 0232 0374.0232.1786 133 85 59 43 33 1;00 64 44 33 25 82 42 25 15 10 Fastening Schedule for Various Wind Speeds Wind Speed�Zone ,Ji. 110 MPH 120 MPH 1 130 MPH 140 MPH Roof Fastener Fastener Size Attaching to: OnCenter OnCenter OnCenter OnCenter Zone Type Spacing Spacing Spacing Spacing or ® #915 2 24,11 ,_�x 241�1 Woad n : X4wOO4zone1 lhsWoodZac -p r � 24" I ` K, G. z Woodgrip® 1x4 wood 1, Zone 2 WoodZac® #9-15 x 1'/z purlins 24" 24" 2401 1211 WOOdgrlp® - ' Wood ee � e rr Zone�3 or ® '#9 15 purlins 1�2 1x4 j; 12 WoodZac, ? Zone 21 � a � ! � Eave Roof Zones a Each "zone"of the roof has its own :. ......................... .........................................;.. screw requirements. Dimension a is defined as 10% of the minimum width of the building, or 40% of the mean ........................................................................ ... height.of the roof, whichever is a smaller; however,a cannot be less —=-----------------Ridge--------------:— --IF- than either 4% of the minimum width .. ......................................................................... of the building, or 3 feet. Zone 1 Gable Ridge Fr ..... .......................' ........................... : Eave Zone 3 r ' �`li on SPa Center � { Al y t9 p Figure Screws lap side of placed onbothsides of the ribs at both eave"and ridge, Eave and the overlapthe 1 (801398-0315 -VAX(352),498m7852 4 e ' a nL in r+ i DETAIL GuIfCoaKe. s - FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING ® Eave Drip fy �; & Fascia 0-01 FHA Style ED-3 Style Eave drip Eave drip iV 7/16' N—b�t For custom cave drip, specify the Eave drip a Eave drip with fascia and inside closure 1 amount of the cave that will be Figure 8 Eave drip and fascia give a finished look along the drip covered(dimension"a"), and, for eave of the house, as well as providing protection for the steeper roofs, specify pitch. If materials they cover.The eave drip should completely cover the Fascia a fascia is desired,be sure that the top edge of the fascia. Inside closures,which seal off the open 1 dimension you order will be ribs of the panels,are optional. —H b i*-- hidden by the cave drip. Summary of Stock Trims and Flashings iters: special order information Ridge caps(RC;2) specify pitch if less than3%12 or greater than 6/12..Also available in. larger widths`Closures recommended. Eave drip (FRA,EI)-3) 2 common styles. FRA style is pre-pitched for 3/12 to 6/12 roofs. For appearance or ease of application, order by either specific pitch or as gable trim (901). Gable flashings :Residential(EM), large� GR-2), and small(GR-1)rakes avaiilable.Use butyl.sealant between rake and panel Valleys (PV-1) specify pitch if greater than 7/12. Seal with universal foam closure material. Open-hemmed valleys (PV-2) aid water-tightness. 'Sidewall (SW. -1) Use butyl:sealant between sidewall flashing and panel. , Endwall(E`'6'-1) Specify pitch if greater than 5/12. Seal with outside closures. .Transition flashin Ly Specify pitches of.,both roofs.. Seal lower slope,using`ouiside closures arid, iff;desired inside closuresori upper.sl'®pe: 1 • If Co�� FORMERLY KNOWN AS TUFF-RIB � SUPPLY & MANUFACTURING Ridge Cap The Ridge Cap is used to seal the point at which two upward slopes meet. This can u „I be both along the ridge of the roof as well — as a covering for a hip. Either woodgrip `f or self-drilling lap TEK screws are , applied through the ribs ofthe metal. Since debris, insects, and blowing rain can find easy access under the ridge 1 ' cap, closures are required to either completely or partially seal the opening Closures under ridge caps come in 3 71 types: solid,vented,and hip tape. Figure 9 Ridge cap showingoutside closure (left)and profile vent Solid closures ("Outside Closures") are (right). the same width as the panels. They lock together in a row placed directly under the screws that attach the ridge cap, and form a solid,water-tight, Z. " air-tightbairier. Profile Vent® comes in 50 foot rolls, is 3 inches wide, and forms a water- ; retardant, insect resistant barrier that allows hot air to escape from the attic,and is superior to many more elaborate and expensive vent systems. Any length maybe ordered. ' Hip closure tape(Peel and Seal) is a sticky, adhesive-backed metallic tape Z3 that seals the hip roof. Itis 6 inches wide and comes in 331/2 foot rolls. Because it must be conformed to the rise and fall of the panel ridges, approximately 10% extra may be needed beyond the length of the hip ( { being covered. Figure 10 Pipe Boots provide a Outside 6„ Profile Vent® j water-tight seal around roof vents and come in a variety of closure of Versa-Vent® S'i'zes. They seal with caulk and conform to the shape of the _ panel ribs. V--Lap or 2'/�"Woodgrip�► screw required RC-2 Standard 12-inch Ridge Caps j I are strong,economical and adequate for most of your roofing needs �I a 611 RC-2 style,over-sized ridge caps are available with 18-inch coverage,or as a custom brim RC-1 style 12-inch Ridge Caps item in total widths'(2 times"a" of 14-, 16-, 18-,20-, are also available in custom widths 22-.and 24-inch i C6S1),EG :BT e ee G�'f Cz,7 ;5 FOAM14ERLY KNOL"JN AS TUFf-R18 SUPPLY & MANUFACTURING 11 a r , End-wall Flashing �.: r *f w > . r Ed-wall flashing is applied where the upward n ' slope of a roof meets a wall. The wall side of the flashing can be covered with siding or counter-flashing, and outside closures are recommendedd)) necessary to seal caulk(Solar between t h e ' caulk edge(order EW-1c) flashing and the , (used if endwall not panel.Roof slope 31 covered by siding) should b e /.� mentioned if roof - 3%��y exceeds 5/12 pitch. Figure 11 As with the ridge cap, the ENDWALL FLASHING above is sealed using outside closures. pa nel EW-1 Stepped Use EW-2 hemmed endwall when cornering endwalls with sidewall b Endwall = EW-2 Hemmed flashing,such as with dormers or chimneys. Endwall For custom end-walls, speck roofpitch and dimensions"a"and"b". �a� 1 �a a=4%z" \y b=3" Transition Flashing _ The TRANSITION FLASHING prevents = leakage at the point where two different roof pitches meet. It must be sealed on the lower side with outside closures, and can be sealed underneath the upper panels with inside closures. The similar GAMBREL FLASHING is used where the lower pitch is steeper than the upper. ! - 6�?arie y,f TF-1 Transition Flashing closure r P b� I~—ate/ Figure 12 The transition flashing (above) and the GF-1 gambrel flashing (right) provide a For custom transition flashing specify the pitches continuous drainage where two of the two roof slopes and,if necessary,dimensions slopes meet. Both seal with "a"and"b". outside closures on the lower side. (898),393,-0335- FAX(351)49$T7852 wwvv.GulfCoas*SqPply�com 10, + T GULFRIB m DETAIL MANUALGulfco��Stc 11FORMERLY KNOWN AS TUFF-RIB S UI P P LY & MANUFACTURING Gable Flashing Poo- Bulyl tape 3/4" jt 1.1 EF-1 s le 7116" Custom trim—specify a custom R length for a or b. Standard dimensions — a=3" Vier of EF-�gante trim(fascia board removed b= 3" Figure 13 Gable'flashings is used to trim the edge of the roofing panel at the gable end of the roof. It should match GR-1 style r—a the eave drip that extends along the drip edge of the roof. If Custom trim—specify a custom the panel is allowed to hang over the gable end, eave drip length for a or b. b can be used instead. Butyl tape between the trim and Standard dimensions — a= 2 Sig" panel eliminates leaks. b=2N ® Side-Wall Flashing r caulk(Solar Seal'recommended) �I caulk edge order SW-1C (used if sidewall not covered by siding) �► Butyl tape Y h a 3/4" r 5 �L :mew o stmrdard srdewrtrtrn: Figure 14 Sidewall flashing is applied when the side of the SW-1 roof butts up against an adjacent wall. The wall-side of the flashing can either be covered over with siding or sealed Custom trim specify a custom with caulk (order SW-1C). Butyl tape should be applied length for a or where the"foot"of the flashing attaches to the roof. Standard dimensions a=3" b=3" i 000, m JLFRIB m DETAIL MANUAL GUIfLoaKf Nr-' FORMERLY xNo wN As ruff-RIB SUPPLY & MANUFACTURING Preformed Valley - Install panels 4 to 6" \ from diverter _ panel _ 4V w��� �. J 0 1 PW style - o a o• �;' z PV-2 style Two basic styles of valley are available. For custom valleys, specify dimension"a" Figure 15 Pre-formed valleys use a diverterto preventwater from rushing under panels on the opposite side, while meanwhile channeling water off the roof. Expanding foam closures are often used to assure a good seal. Gulf Coast Tuff-lib® Siding GR 2 Rake & `ter, Corner"p. 13 1 f d Drip Cap "" 1 ti } Sliding Door Iasi I- Corrie�N Gutter J-Chan-nel (p\15) (p 14) f TC 1 Track' Base Drip 'Cover(p (p. 14) Figure 16 Common trims associated with Tuff-rib roofing panels 1(888) 393-0335 FAX(352)498-7852*www.GulfCoastSupply.com 12 Ix r . : DETAIL s ,o Ix Gulf 2 i. FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING I GR-2 Outside Corner loo. The GR-2 Rake and Corner can be used as a gable trim or a corner for metal-sided buildings. - �-�,- As an alternative, the smaller EF-1 or the GR-1 �• ; W (both on p. 1 l)can also used as gable rakes,and the It PC-5(below)or the GR-1 as corners. Customizing rakes or corners is often necessary � J- due to their landing on a panel rib. Both the GR-2 and the IS-2 can be ordered as custom trim items 77 by specifying custom dimensions cc a" or"b". cb . Be sure to take into account the 3/4""heads ace"when .: figuring custom dimensions. 62 R Ij 3I The PC-5 flat cornerC.. "Ale, works best on smaller Figure 17 When used as corn'ertrim,the GR-2 straddles the ribs aof the panels where they meet at the corner of the building. The structures and where the panels are running Tuff-Rib outside corner also serves as a gable rake(see below). �i VY I .outside horizontally. It can be The inside corner (IS-2) has similar dimensions but with a closure sealed with outside reverse middle bend. closures. a PC-5 -=-= ® Gly-2 Gable lake 45./8 34" 1 i 4 sis„ GR-2 b I b IS-2 Figure 18 When used as a gable rake,the GR-2 runs parallel to the ribs of �—a the roof panel, and is attached with screws running through the ribs of upright siding. As with the EF-1 residential rake, the roof side can be sealed with butyl sealant. i . . i i .. TM GULFRIB DETAIL MANUAL GuIfCoas L� �lr r FORMERLY KNOWN AS TUFF-R18 SUPPLY & MANUFACTURING - Y" Drip Cap and J-Channel -_ Drip cap, drip cap I . m 2'1/2"- f G x �r k capping the panel end joe JC-1 i y J-channel 111 Figure 19 The drip cap is commonly used to trim out the bottoms of panels over doorways and windows, and occasionally takes the place of base drip. J-channel is used to cap raw panel edges where run-off is not a problem,and panel /8t1 is most commonly used to trim around the bottom,sides,and occasionally the top of windows and doors,and also to cap the top sides of skirting. Gapping he panel edge Base Drip ® - --- r 1 , c cu 117 1 L7/8 11 5 � '✓ r.✓" BD-1• Base.drip 11/411 Figure 20 Base drip seals off the bottoms of panels at the floor level,where it helps to prevent the entrance of rodents and insects,as well as a base for the setting of panels. 51 . : DETAIL MANUAL G 'lfc(aagl FORMERLY KNOWN as TUFF-RIS SSU P P LY & MANUFACTURING Gutters 00- Gulf Gulf Coast Supply produces 29-, 26-, and 24- gauge gutters in either 5-or 6-inch widths(depth is approximately equal to width). All gutters should be ordered specific to the pitch of the roof. Downspouts are available in 3"x411 (for 5- r inch gutters) and 411x4" (for larger gutters). End } r caps should be ordered at the same time as the c` gutters to assure a custom fit. Special hangers fit into ( the panel rib and under the gutter lips Panels should extend no more than 1 to 11/2" inches , O` beyond the eave on which gutters are planned. lap screws , Figure 29 Exposed view of guttershowing gutter hanger placement, �--5 or 6 —� ; ; f: °�` downspouts, and end caps. Hangers employ lap screws,and end caps are best attached with rivets. I` Gutter hdngers.fit inside patel rib and under lip o - ;. ®liter Inner OuG�r .Inner 3 er of gutter:(apply at least --- - one per panel)and are Inner and outer gutter sections(marked`I"and "O") attached with lap screws alternate along the eaVe to assure ease of application and or-rivets. gutter appearance. f Do nspout: DownspouL in excess of 10 feet in length must be made in 2 sections. II I ® Track Covers OHM- 1 Door 92 header TC-1 a 14 sliding door track cover 21/211 511 r Figure 22 Sliding door track covers fit over the door track and Door ; under the panels to hide the track,assure a neat appearance,and shed water over the door. �! it' 1(98;3,)393mQ,3' ,35 FAX,(352)498m7852 9 www.GulfCoastSupp1y.cori1 15 001", GU LFRI BT . GuIfCoast "--' ', FORMERLY KNOWN AS TUFF-RIB SUPPLY & MANUFACTURING 1 '�. 0, Ridge caps(pg.9) Eave drip(pg.8) Valleys(pg. 12) Gable rakes(pg. 11) Sidewalls(pg. 11) Endwalls(pg. 10) !9 :) Transition&gambrel Door&window flashings (pg. 10) Corner trims(pg. 13) trims(pg. 14) Base drip(pg. 14) Pipe Boot(pg. 11) Electrical Boot 7AN Inside Closures ® Expanding �, Outside Closures Versa-Vent Profile Vent foam Peel and Seal Touch-up Paint Alm Now S } ISILTEK Lap EK Foil-backed thermal Butyl Tape Solar Seal barrier insulation Woodgrip Screws TEK screws ZAC screws Guide to Misc. Accessories item application pipe boot Fits over vent and heat pipes. Available also in heat-resistant boots. electrical boot Fits around,pipes with inaccessible tops (such as weatherheads)_ outside closures Required to seal under ridge caps and transition and endwall flashings inside closures Seals under panels,particularly on the eave Profile Veni;Versa-Vent® Vented closure material surpassing many other venting systems. expanding foam Compressedadhesive foam•eipandsto,seal between valleys and panels Peel and Seale Seals hips under hip caps. Also, a general purpose sealing tape (6" wide). touch-up paint Hides scratches and mars encountered in installation Over 20 colors butyl tape General purpose low-cost sealant, used on panel laps and under trim --- Solar Seal" `A superior general purpose-caulk for ail Joints.--Matches panel colors_ Low profile insulation Greatly reduces radiant heat when installed under panels. 'pTscrews 'Used in all'applications attaching metal to wood.``1", 1%Z", 2'/Z" sizes TEK screws Self-drilling TEK screws for metal purlins. Lap TEK screws draw together Joints and attach trim. - --- - -- - --- ---- - ....- — - ,. .. - - _._ . - - - - . ..- - --- 77 --- -- ZAC°-screws` "Lifetime" screws; 11/�" '2'%Z",threaded for wood; self-drilling available.,,,'"[ . .