HomeMy WebLinkAboutEngineering BUILDING'S PEAK ROOF HDOHT M. DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING (P.S.F•) FOR ASCE 7-10 - PEAK ROOF HEIGHT LESS THAN OR EQUAL TO 60 FEET ar
B451C WIND SPEED - 170 mph RISK CATEGORY lI BUILDINGS
RESIDENTIAL, APARTMENT BUILDINGS& COMMERCIAL BUILDINGS(RETAIL, WHOLESALE)
R E C EI`.'S0 MAR 04 2016 This is Not A Master [drawing.
PEAK L"LESS THAN 7'-9' L••GREATER OR EQUAL THAN 7'-9'AND I-GREATER OR EQUAL THAN 12'-J' Valid Only Par One Time Permit,
ROOF LESS THAN 12'-5'
HEIGHT POSITIVE NEGATIVE POSITIVE NECA17VE POSITIVE NEGATIVE
(h) ULTIMATE A.S.D. ULTIMATE A.S.O. UL NMATE A.S.D. ULTIMATE A.S.O. UL BALI TE A.S.O. ULTIMATE A.S.O. INOlDATED DESIGN WIND PRESSURES
01- 15' 76.4 45.8 102.4 61.4 73.0 4J.8 95.5 57.7 68.5 41.1 86.4 51.8 CORRESPOND TO THE MAXIMUM END
ZONE AND INTERIOR ZONE CONDITIONS
> 15'-20' 80.4 48.2 107.6 64.6 76.8 46.1 100.4 60.2 72.0 4J.2 90.8 54.5 AND FOR ALL ROOF
>20'-25' 83.6 50.2 111.9 67.1 79.8 47.9 104.4 62.6 74.8 44.9 94.4 56.6 SLOPES.
STORY>25'-30' 86.2 51.7 115.5 69.J 82.4 49.4 1077 64.6 77.3 46.4 97.4 58.4 **L a ACCORDIONESHUTTER
>JO'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 SHEER HHHEIGHT.R 84HAAM
>40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 117.7 70.6 84.4 50.6 106.5 63.9 A1CA1[* PRODUCTS WHICH BEAR A
>50'-60• 973 58.4 130.3 78.2 92.9 55.7 121.5 72.9 87.2 52.J 109.9 65.9 MIAMI-090£COUNTY OR A
STATE OF FLOR04 APPROVAL
BUILDING'S PEAK ROOF HEIGHT Me DESIGN WIND PRESSURE FOR COMPONEMM A CLADDING MSF.) FOR ASCE 7-10 - PEAK ROOF HEIGHT GREATER THAN 60 FEET ar
BASIC WIND SPEED - 170 mph RISK CATEGORY Il BUILDINGS
RESIDENTIAL, APARTMENT BUILDINGS& COMMERCIAL BUILDINGS (RETAIL, WHOLESALE)
?�Oof if
�E0
PEAK L••LESS THAN 12-5' L••GREATER OR EQUAL THAN 12'-5'
ROOF
HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE
(h) ULBWTE A.S.D. ULTIMATE A.S.O. y^IC- U E
>60,-70• 1.5 54.9 167.7 1 00.6 84.3 0.6 148.4 89.0 BUILDING SCHEMATIC
- 93.6 56.2 171.6 103.0 51.7 .9 91.1
>80'-9D• 95.6 57.4 175.2 105.1 88.0 52.8 155.0 93.0
>9o'- 1DD' 97.7 58.4 178.4 107.4 89.7 53.8 157.9 94.7
> 100'- 120' 100.5 60.J 184.2 110.5 92.5 55.5 163.0 97.8
> 120'- 140' 1OJ.2 61.9 189.2 113.5 1 95.1 57.1 167.4 100.4
> 40_ 105.6 63.4 193.6 116.2 97.3 8:4-1 171.3 O2;er11104�II�I
> 160'- 180 107.8 64.7 197.6 118.6 99.3 59.6 174.9 104.9 11,too
��IE�A:.r.�!/T
10 ._
> TB - OD' 109.6 65.9 201.3 120.8 1.1 s.7 178.1 �PSF••'•,��
>200'-250' 114.1 68.5 209.2 125.5 105.2 63.1 185.1 111.1
>250'-300' 1178 70.1 216.0 129.6 108.5 65.1 191.1 114.7
>300'-750' 121.0 72.6 221.9 133.1 111.5 66.9 196.3 117.8 * t• No•44167
>750'-400' 127.9 74.3227 1 1 J6.3 114.1 68.5 200.9 120.5
>400'-450' 126.4 75.8 231.8 1J9.1 116.5 69.9 205.1 123.1 �•�• STATE OF r�
>450'-500' 128.8 77.J 236.1 141.7 118.6 71.2 208.9 125.3 ?Oj� •.F�0�10'Q;•.• �A,AA
'�sS�dlilAl- --to
I.)THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART,PREPARED BY THIS ENGINEER,B45ED ON ASCE 7-10,FOR A 84SIC WIND SPEED OF 170 MPH,AND 2014(5(h EDITION)FLORIDA BUILDING CODE-BROWARD,PALM BEACH,MARBN, Sr LUCIE&INDIAN RIVER COUNTIES
APPLICABLE RISK CATEGORY BUILDING&EXPOSURES,IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMABON FOR A SITE SPECIFIC PROJECT.
ASCE 7-10/ WIND PRESSURE CHART AS SHOWN
2.)THIS WIND LOAD CHART MUST BE SIGNED,SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE BME BUILDING PERMIT. STORM PANELS,ACCORDION&BAH4W SHUTTERS SCALE
J.)CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECBON OF DESIGN WIND PRESSURE 94SED ON THIS GENERIC WIND LOAD CHART. RISK CAT. If BLOCS 06/1 V15
WIND PRESSURES ARE ULTIMATE AND A.S.D.PRESSURES DATE
4.)THIS WIND LDAO CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. I ECO 1 N c. WINO PRESSURE CHART
7/L1JT 1ESBN0 t ENC/NEER/NQ COMPANY BASIC WINO SPEED- 10. mph 15-188
5.)DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY mm mw.Yam.N &Ym,ENGINEERING COMPANY EXPOSURE E Kd 70
THE CONTRACTOR OR PERMIT HOLDER(0.0.,SPRFADS'HEET,OPENING SCHEDULE/rAKE OFF SHEET,ETC.). Pno�.:rymlml-Imo.To.:4=141-111,11" DRAWING No
EB-0006719 °ararmwTr
WALTER A.TILLIT Jr.P.E. an n Mla _
FLORIDA U..4441
67 Y.muxrVs SH[£7 1 OF 1