HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC.
806 Delaware Avenue, Fort Pierce, Florida 34950
PHONE(772)460-7751 FAX(772)460-4244
EMAIL cookmenard@yahoo.com -
March 1,2016
RECEIVED MAR 0 9 '20116
St. Lucie County Building Department
Attn: Roof Permit Plan Review FILE Copy
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at
7000 Silver Oak Drive,St. Lucie County, Florida
Manufacturer: Gulf Coast Supply&Manufacturing
Profiles: 26 Ga 5v Crimp FL#11651.12
Code: FBC 2014;Section R 905.10
Wind Speed: 165 MPH; Ultimate Design Wind Speeds
Exposure: B
Mean Roof Height: 20' Maximum
Pitch: 3"/12"
Required Design Pressure: Zone1:-40.6 Zone 2:-57.4 Zone3:-107.9
Maximum Uplift Pressure: -108.5 psf @ 12" O.C.
Fasteners: #9-15x1.5" @ 12"O.C.with sealing washer through panel rib with%"minimum
penetration through plywood
Underlayment: Owens Corning T&M Metal underlayment FL#9777 direct applied to plywood deck
Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6"o.c.thru out
Zone 1,4" o.c. perimeter&6" o.c.field Zone 2,and 4" o.c.thru out Zone3
The above approved,as per Florida Building Code Compliance acceptances, 2014 Florida Building Code,and the
Manufacturer's recommendations.
Respectful Iy.Submfitted,
r .
Peter.B Cook
Cook<�&Men ard�Architecture,Inc.
Florida Registration No. AA0003494, NCARB Certification No. 31789