HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC. 806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE(772)460-7751 FAX(772)460-4244 EMAIL cookmenard@yahoo.com - March 1,2016 RECEIVED MAR 0 9 '20116 St. Lucie County Building Department Attn: Roof Permit Plan Review FILE Copy 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at 7000 Silver Oak Drive,St. Lucie County, Florida Manufacturer: Gulf Coast Supply&Manufacturing Profiles: 26 Ga 5v Crimp FL#11651.12 Code: FBC 2014;Section R 905.10 Wind Speed: 165 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 20' Maximum Pitch: 3"/12" Required Design Pressure: Zone1:-40.6 Zone 2:-57.4 Zone3:-107.9 Maximum Uplift Pressure: -108.5 psf @ 12" O.C. Fasteners: #9-15x1.5" @ 12"O.C.with sealing washer through panel rib with%"minimum penetration through plywood Underlayment: Owens Corning T&M Metal underlayment FL#9777 direct applied to plywood deck Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6"o.c.thru out Zone 1,4" o.c. perimeter&6" o.c.field Zone 2,and 4" o.c.thru out Zone3 The above approved,as per Florida Building Code Compliance acceptances, 2014 Florida Building Code,and the Manufacturer's recommendations. Respectful Iy.Submfitted, r . Peter.B Cook Cook<�&Men ard�Architecture,Inc. Florida Registration No. AA0003494, NCARB Certification No. 31789