Loading...
HomeMy WebLinkAboutProduct Approval a M3 01 erSswd�-s:,...7�4,�- r, SCIS Home y Log In _i User Registration yHot Topics + Submit Surcharge Stats&Facts Publications ! FBC Staff BCIS Site Map Links Search j Busne5) 4P productApproval ProfessionalUSER:Public User , Product Aooroval Menu>Product or Aonlication Search>Application List>Application Detail K FL# FL5777-R4 Application Type Revision Code Version 2014 7 Application Status Approved c I NA-02 n FI� L- Comments 4'i ° Archived Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala,FL 34474 (352)368-6922 ekoss@cws.cc ' Authorized Signature Koss Erin ekoss@cws.cc Technical Representative Erin Koss Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352)368-6922 Ext 291 ekoss@cws.cc Quality Assurance Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Category Windows Subcategory Mullions Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lucas A.Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M.Urich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL5777 R4 QQI EvalRep CWS_244 3 in M l_ll N).Ddf Referenced Standard and Year(of Standard) Standard Year AAMA 450-06 2006 AAMA/WDMA/CSA 101/I.S.2/A440 2005 TAS 202 1994 Equivalence of Product Standards Certified By Sections from the Code w Product Approval Method Method 1 Option D Date Submitted 04/28/2015 Date Validated 04/29/2015 Date Pending FBC Approval 05/04/2015 Date Approved 06/23/2015 Summary of Products FL# Model,Number or Name Description 5777.1 Adjustable(Angled)Mull Adjustable Mullion for Alum.and PVC Windows. Limits of Use Installation Instructions Approved for use in HVHZ:No FL5777 R4 II CWS-24 _Mu 3B._( djll_NIf,pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Not for use in HVHZ.See Mullion Product Evaluation FL5777 R4_AE._Eval_Re_.._CWS-2438 Ad'_Mull,NI.,.df P _ _. (_.) _—)P__ Report for complete list of Limitations and Conditions. Created by Independent Third Party:Yes 5777.2 CWS-1758 Mull Bar 3"Mull Bar for PVC Windows. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL5777 R4 II CWS-4306(3 in Mull,NI)pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Mullion Product Evaluation Report for complete list FL.5777.._R4.AE Ev_alRep CWS-430B(3 in_MullNI),_pdf of Limitations and Conditions of Use. Created by Independent Third Party:Yes 5777.3 CWS-1759 Mull Bar 4"Mull Bar for PVC Windows. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL5777 R4 II CWS-431B,.(4-in Mull,_NI).pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Mullion Product Evaluation Report for complete list FL5777 R4_AE EvalRe CWS-431B(4 in Mull�NI).pdf of Limitations and Conditions of Use. Created by Independent Third Party:Yes 5777.4 CWS-1760 Mull Bar 5 1/2"Mull Bar for PVC Windows. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL5...777._R4._II CWS=432B_C5 in Mull_ND.p Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Mullion Product Evaluation Report for complete list FL5777R4__AE_EvaIRep.CWS.-432B..(5_in_MUII,_NI).pdf of Limitations and Conditions of Use. Created by Independent Third Party:Yes 5777.5 CWS-1950 Mull Bar 2"Mull Bar for Aluminum Windows. Limits of Use Installation Instructions Approved for use in HVHZ:No FL5777 R4 II CWS-2456(2 inMull.NI).pdf Approved for use outside HVHZ:Yes Verified By: Lucas-A.Turner 58201 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-N/A Evaluation Reports Other:Not for use in HVHZ;See Mullion Product Evaluation FL5777__R4._AE_EvalRep CWS-2458(2 in Mull,NI)_Pdf Report for complete list of Limitations and Conditions of Use. Created by Independent Third Party:Yes 5777.6 CWS-1952 Mull Bar 3"Mull Bar for Aluminum Windows. Limits of Use Installation Instructions Approved for use in HVHZ:No FL5777._R4 II CWS_244B_.(3 in Mull NI).pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-N/A Evaluation Reports Other:Not for use in HVHZ;See Mullion Product Evaluation FL5777 R4 AE EvalRep CWS-244B(3 in Mull NI)_pdf Report for complete list of Limitations and Conditions of Use. Created by Independent Third Party:Yes Back Next Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 • The Statc of Florida i5 an AA/EEC employer.Cory.ioht 2CC7.2C:2 Stzic cf Fie{,dc.: - statement•:Accessibility Statement::liefuad Statc:aan: Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, 4 I 1 GENERAL NOTES: 3" PVC MULL BAR - NON-IMPACT 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO C( SHOWN w/DIFFERENT OPTIONS THE FLORIDA BUILDING CODE(FBC),CURRENT EDITION INCLUDING HVHZ 2.CONFIGURATIONS(SEE SHEET 2):VERTICAL OR HORIZONTAL: 3.SEE MULLION CHARTS FOR MAX.DESIGN PRESSURES AND LENGTH. (REFER TO SHEETS 2-3) r— —— --——— — —— 4.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED IN TH \ DESIGN OF THIS PRODUCT.SEE SHEETS 9-10 FOR ANCHOR DETAILS. WII DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIOP 5.NOT APPROVED FOR IMPACT RESISTANCE. IMPACT PROTECTIVE SYSTEE O REQUIRED IN WIND BORNE DEBRIS REGION. 6.DESIGN PRESSURE OF MULLED UNITS SHALL BE CONTROLLED BY THE LE DESIGN PRESSURE OF THE MULLION.OR THE INDIVIDUAL WINDOW UNITS i -ANCHOR CLIP — —— —————— — ——— — —————— ANCHOR CLIP - 7.DESIGN PRESSURES AND INSTALLATION DETAILS SHOWN IN THIS DOCUR A I I C I I APPLY ONLY TO THE MULLION.WINDOWS MUST BE APPROVED UNDER SE 6 �� I APPROVAL. OE B O O 8.RESPONSIBILITY.OF SELECTING FENESTRATION PRODUCTS TO MEET AN i APPLICABLE LOCAL LAWS,BUILDING CODES,ORDINANCES OR OTHER SA REQUIREMENTS RESTS SOLEY WITH THE ARCHITECT,ENGINEER OF REC - I I BUILDING OWNER OR CONTRACTOR. I I I I I 9.SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THI DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFAC' I I I I CUSTOM WINDOW SYSTEMS,INC.AND MUST BE MADE OUT OF VINYL PVC X I I X I X EXTRUDED ALUMINUM. I I 10.VERTICAL MULLED UNITS MAY BE MULLED INDEFINITELY AS LONG AS TF UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED,AND MULLIONS ARE ANC SHOWN I-IERE T:. - ANCHOR CLIP 11.HORIZONTAL MULLION SHALL EXTEND THE ENTIRE WIDTH OF THE MULL 10 10 9 121) VERTICAL MULLION IS USED TO MULL SIDE BY SIDE UNITS TOGETHER. EXAMPLE HORIZ/.VERT.MULLION FOR SECTION VIEW ONLY ANCHOR CLIP— LUCBS A. 2015-04-2 -- -- -- -- 10:41-04:( TABLE OF CONTLWIS GENERAL NOTES&ELEVATIONS...............1 DPCHARTS.................................................2-3 BOM&EXTRUSIONS.....................................4 ANCHOR CLIP EXTRUSIONS.................................................5 SECTION VIEWS.........................................6-7 EXAMPLE VERTICAL MULLION FOR CONFIGURATIONS&ANCHOR NOTES.......8 PVC WINDOWS FOR SECTION VIEWS ONLY ;NSTALLATION DETAILS...........................9-10 �,_ N PRESSURE CHART(PSF)FOR NON-IMPACT ALUMINUM 3"MULLION H-1758,HORIZONTAL OR VERTICAL,WITH 1522 or 1767 CLIPS USING FOUR(4)#10 SCREWS )OD or METAL,3/16"ITW TAPCONS or ELCO•ULTRACONS INTO SOLID CON RETE WITH WASHERS PER CLIP. HOLLOW or GROUT-FILLED BLOCK REQUIRES FOUR(4) aa��®m'w 1/4"ELCO ULTRACON WITH THE 1767 CLIP. WINDOW SYSTEMS J OPENING WIDTH(in.) .1900 SW A4TH AVE. OCAL-A,FLORIDA 34474 _ . 3 pQ 45 51 57 63 69 75 •I. 81 .= '87 93 99 20G 3/3 114 120 '132 .- 144, . WWW.Cws.Cc 120 120 120 120. 120 120 120 120 120 . 116 _ 109 102 96 91 83 76 /4 120 1'20 120 120 120 120 120 113 106_ 99 94 88 82 78 71 66 /4 20 120 120 120 120 113 .105 98 _ :92 86 81 76 71 68 62 57 $�� PVC /8 120 120 120 120 111 103 95 '89 83 79 74 69 65 62 57 52 MULL BAR _120 120. 120 112 103 95 t38_ 82 -_T7 3 _69 64 60 58 53 49 _ 120 120 110 100 92 85 79 74 69_ 65 62 58 54 52 47 44 NON IMPACT /4 120 1.13 102 93 86 79 74 69 65 61 58 54 51 49 44 41. v, 117 104 94 86 79 72 66 62 57 •54 51 47 44 42 38 35 ,n u.i 103 `90 81' 73 67 61 56 52 -49 46 43 40 . 37 36 32 _ 30 I oro 88 77 69 62 1 57 52 48 45 42 39 37 34 32 1 30 28 25 76 67 59 53 49 45 42 -39 36 34 32 30 28 26 24 22 w ~ m 62 54 48 43 39 36 34 31 29 27 26 24 22 21 19 18 51 44 39 35 32 30 28 26 24 23 21 20 18 18 16 15 z m m O 42 37 33 29 27 25 23 21 20 19 18 16 15 15 - o U) '/8 37 32 29 26 24 22 20 19 18 17 16 15 - - N N Z W 30 26 23 21 19 17 16 15 - a a d 1 26 22 20 18 16 15 w �w 22 19 17 15 o a U 19 17 15 > > o 17 15 T IS FOR: �%up "�� ACT 3':MUL!InRI.758,HORIZONTAL OR VERTICAL,.USING EITHER(PER END) �e�� REIf !y4 . Pi� 1767 CLIPS y,�.O�..��GENS�. 0 SCREWS INTO WOOD or METAL No 58201 16"ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD LIPS4U Z /4"ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCK 59 STATE of C u 0'��S OR 1� i', � ��Z91ONA� TRANSOM OVER TWIN TRANSOM OVER TRIPLE*- � TWIN TRIPLE HORIZONTAL'MULLION VERTICAL MULLION' VERTICAL MULLION f VERTICAL MULLION VERTICAL MULLION 4/27/2015 7- T- LUCAS A.TURNER,P.E. FL PE#58201 F N 1239 JABARA AVE. T L4 NORTH PORT,FL 34288 x F w w z ISINGLEI PH.941-380-1574 0 0 J J w TWIN OR SHEET DESCRIPTION: w � o ITRIPLE1 DP CHART UNITS 1522 or 1767 CLIP IBELOW� 4 ANCHORS LI LI I I II L II I I I DRAWN BY: DATE: 1 OPENING SIZE--i I OPENING SIZE F- F-- OPENING SIZE—^I OPENING SIZE I- I-- MULL LENGTH--I RS 04/13/09 DWG M: REV.: CWS-430 B SCALE: SHEET 1:1 2 OF 10 l DESIGN PRESSURE CHART(PSF)FOR NON-IMPACT ALUMINUM 3"MULLION H-1758,HORIZONTAL OR VERTICAL,WITH 1767 CLIPS USING SIX(6)#10 SCREWS INTO WOOD or METAL,3/16"ITW TAPCONS or ELCO TAPCONS WITH WASHERS PER EACH END OF MULLION. HOLLOW or GROUT-FILLED BLOCK REQUIRE SIX(6)1/4"ELCO ULTRACONS WITH THE 1767 CLIP. OPENING WIDTH(in.) 39. • 45 51 57 63 E9 : - 75 81 87 ' 93 99 1063/8-1 114 -• 120 132 144 37 120 120 120 .120 120 120 120 120 120 120 120 120 120 120 120 120 ' 423/4 120 120 120 120 120 120 120 120 120 120 120 120 120 120 115. 106 483/4 •120 .120 4120 120 120 120 120 120 120 120 120 120 115 110 100 92 531/8 120. 120 '120 120 120 120 120 120 120 120 119 112 105 1,00 _ 91 . . 84 57 120_ 120 120, 120 , 120 120 120. 120_ 116 109 102 95 89 84 77 71 63 120 120 120 . 120 118 108 99 92 86 80 76 70 66 63 57 52 ^ 663/4 120 120 120 109 99 .91 83 77 72 68 64 59 55 53 48 44 72 120 107 95 86 79 72 66 62 57 54 51 47 1 44 42 38 35 76 103 90 81 -73 67 61 56 52 49 46 43 40 37 36 32 30 80 88 77 69 62 57 52 48 45 42 39 37 34 32 30 28 25 w �84 76 67 .59 53 49 45 42 39 36 34 32 30 28 26 24 22 J 90 62 .54 48 43 39 86 34 31 29 27 26 24 22 21 19 .18 M 96 51 44 39 35 32 30 28 26 24 23 21 20 18 18 16 102 42 37 33 29 27 25 23 21 20 19 18 16 15 1063/8- 37 32 29 26 24 22 20 19 18 17 16 - - 114 30 26 23 21 19 17 16 15 - - 120 26 22 20 18 16 - - - - - 126 22 19 17 15 - - 132 19 17 - - - - - - - 138 17 - - - DP CHART IS FOR: NON-IMPACT.3"MULLION 1758,HORIZONTAL OR VERTICAL,USING EITHER(PER END): 1767 CLIPS (6)#10 SCREWS INTO WOOD or METAL (6)3/16"-ITW TAPCONS or ELCO.ULTRACONS INTO_SOLID-CONCRETE.or WOOD. (6) 1/4"ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCK TRANSOM OVER TWIN TRANSOM OVER TRIPLE TWIN TRIPLE HORIZONTAL MULLION VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION W T rN Co 0 U) x x w w c7 ISINGLE1 z z z TWIN W W - J J W I OR J J g p ITRIPLE1 UNITS iBELOW' F-- OPENING SIZE--I '" -I OPENING SIZE Ir-- OPENING SIZE OPENING SIZE F— MULL LENGTH 'ART#. DESCRIPTION FRAME TYPE OPENING T"MULLBAR CLIP "L"MULLBAR CLIP 1-1758 1 3/8"x 3"MULLION TUBE (F-1522-XXX) (F-1767-XXX) #10 OR#12 HEX WASHER HEAD TEK SCREW'(see note below) NEW F-1522-013 F-1767-001 VIIIN(�OilOn?VY SYSTEMS #10 x 1 1/2",PANHEAD PHILIPS ZINC FLANGE . O -1522-006 F-1767-001 1900 SW 44TH AVE: #10 FLAT WASHER _ OCALA FLORIDA 34474 FIN WW i-1522' RETRO FIT MULL ANCHOR CLIP - _ - I NEW F-1522-013' F-1767-GG4(L&R)' j W.CWS.CC 5-1897 MULLION CLIP. RETRO F-1522-013 F-1767-004(L&R) SEALANT NEW NOT RECOMMENDED F-1767-001 i-1895 DRIP CAP BOX RETRO F-1522-006 F-1767-001 3" PVC -1896 FLANGE ADAPTER (MULL BAR I-6018• MULLION INTERIOR COVER -3436' MULL BAR CAP NON-IMPACT 522-013 3"SLOTTED NEW CONTRUCTION FIN MULL CLIP 522-006 3"SLOTTED T-CLIP r 767-00:1 L-ANGLE 3"MULL CLIP,STANDARD r r' 767-004L L-ANGLE 3"MULL CLIP,FIN,LEFT '67-004R L-ANGLE 3"MULL CLIP,FIN,RIGHTLL I oro j #10 HEX WASHER HEAD TEK SCREW w FW- m 7D.SCREW SIZE(#10 OR#12),SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENT U)i m U Z I m m p 1 3/4" 1/2"fi- 11/16" ` 9/�2" 1 7/16" (2")--}1 7/16" 9/32 N N Z W cc cc T 1/2"1 n 7/16" w w O L6" a L /16" 1 15/16 q_L ww rC 1/16" 1/16DRIP CAP S-1895 16" 3/8"MULLION INTERIOR ") o o COVER S-6018 FLANGE ADAPTER S-1896 1 3/16 T— IL o p b---A2 7/16" 1/4" 1 11/16" i1 7/8") 1 �— 4 1/8" ttillmill 1316-. .I� ... , t/4" (TYP)—/ `:__ \� a�`,TJOREstirfrr?rr .J 3/8" TOP VIEW 27/16" I 15/16"-'r- i21/4"1 No 58201 3/16" 1l8.. .. I ' i1- 5/8" = 21/16" 53' STATE OF 1 3/8" : I I 1 -� 7 1 3/4"----+�' --i - 151 I f�0 •f,(O 1 3/16" ••• ' 3"MULLBAR H-1758 - -1/8„ 2 3116" rrr s101VAI 'L'L" ` llnnrrU � MULLION CLIP 5-1897 L �— 14' 4 7/8" 4/27/2015 LUCAS A.TURNER,P.E. rOA 2 1/4" F-1522-006 FL PE#58201 1/8" RETRO/FLANGE CLIP 1239 JABARA AVE. /, NORTH PORT,FL34288 � . L PH.941-380-1574 \ 4 7/8" SHEET DESCRIPTION: � F-1522-013 NEW CONSTRUCTION/FIN INSTAL!AT[ON BOM AND EXTRUSIONS ' SCORE,BEND AND BREAK — \ DRAWN BY: DATE: TO REMOVE FIN FOR FRAME ATTACHEMENT TO MULL BAR RS 04/13/09 DETAIL A DWG#: REV.: TYP.FIN FRAME 3:1 CWS-430 B SCALE: SHEET .L•EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OT;IERWISE NOTED. 1:2 4 OF 10 I FRAME TYPE OPENING "T"MULLBAR CLIP "Ll.MI (F-1522-XXX) (F- FLANGE NEW F-1522-013 F NOTE:IF USING CLIPS WHICH REQ.FOUR(4)ANCHORS PER END(REFER TO RETR -1522-006 F SHEET-2);THE MIDDLE HOLE(CIRCLED)MUST BE USED WITH ANY OTHER HOLE AS REQ'D PER EDGE DISTANCE. NEW F-1522-013 F-17f FIN RETRO F-1522-01.3 . F-17 BOX NEW NOT RECOMMENDED F RETRO F-1522-006 F i I _ i r i 17 �8 -2114"- i _ j ! 1518, =.2 3/4") I i , 3/8"T(2XX - 7/16"THRU(TYP) 11. L 1/2" OUTSIC U34' P)-� - I7/16" (TYP) 31 (23/4") 6 7/8° 1t2"1 2314-- "L"ANGLE 3"STANDARD MULL CLIP-F-1767-001 "L"ANGLE 3"MULL CLIP,FIN(LEFT)F-1767-004L "L"ANGLE 3"MULL CLIP,FIN(RIGHT)F4767-004R OUTSIDE • I ! CCugMUD WIND01. S 8Ts 1S 1900 SW 44TH AVE. OCALA,FLORIDA 34474 WWW.CWS.CC FT, ° ° � CD 3" PVC MULL BAR j SEAL BEHIND FLANGE, APPLY SEALANT ALONG FULL 0 NON-IMPACT VD FLANGE PRIOR TO'ATTACHING LENGTH OF WINDOW FRAME JTACHING TO MULLION /2` GROOVE PRIOR TO ATTACHING t•� �— �2 N Q J O I COVER T`J n r UC7 FIN MUST BE REMOVED oEll _ WHERE WINDOWS CONNECT TO MULL w I_ m I' z D U U Z m m v o UJ N N Ziw A VERTICAL/HORIZONTAL MULL BAR SECTION W w j i . (�,HORIZONTAL MULL BAR SECTION �A1 HORIZONTAL MULL BAR SECTION ( a i F 6 BOX FRAME WINDOW o o a 6-1 FLANGE FRAME WINDOW 6 FIN FRAME WINDOW w w ¢ 0 0 w > > o i j m ¢ O I z. APPLY SEALANT ALONG FULL ._ ir�hrrr LENGTH OF MULLBAR GROOVE ♦ pN rr '. PRIOR TOATTACHING'DRIP I �,```� •' G��lg'•UQ�'.~ ADAPTOR U `— No 58201 a0 0� r I FIN MUST BE REMOVED WHERE WINDOWS STATE OF 41J` CONNECT TO MULL on k fl o0 Q Q a 0 �'••.Si�NA a a� 'o ��o DETAIL A 4/27/2015 SEAL BEHIND FLANGE ,I_• VEHIND FLANGE ��(SEE DETAIL B) PRIOR TO ATTACHING DETAIL 11L o) LUCAS A.TURNER,P.E. TO ATTACHING' TO MULLION'' '"' "" APPLY SEALANT ALONG FULL FL PE#58201 LLION LENGTH OF MULLBAR GROOVE 1239 JABARA AVE. PRIOR TO ATTACHING FLANGE NORTH PORT,FL 34288 ADAPTOR PH.941-380-1574 B VER=WINDOW � B VERTICAL MULL BAR SECTION i 6 FLAN6 FIN FRAME WINDOW - Lf SHEET DESCRIPTION: tL L SECTION VIEWS MULLS DRAWN BY: DATE: RS 04/13/09 . _ 10 DWG#: REV.: DETAIL B .CWS-430 B SCALE: SHEET 1.2 6 OF 10 6 i 17 , T ' I CD c o 0 A - - CD" o . { A ,7 SECTION VIEW A-A TOP VIEW FIN FRAME a o O 5"MULLBAR(H-1760) 2 n (SEE SEPARATE APPflOVAL FOR � 4'MULLBAR(H-1759) APPROPRIATE DP CHARTS) (SEE SEPARATE APPROVAL FOR oL APPROPRIATE DP CHARTS) � p 9 - 9 Q 9 7 SEE NOTE 1 E 1 S --7 EE NOTE 1 7 SEE NOT Q i1 19 SEENSEE NOTES 1&2 O TES,& 1 ,9 SEE NOTES 1&2 (2 EA./CLIP) S E CLIP) (2 EA./CLIP) 3..H0 RIZ.TO 3 VERT.MULLBAR SECTION 5"HOR!Z_TO 3".VF_RT.MULLBAR SECTION.. _ C�4"HORIZ.TO 3"VERT.MULLBAR SECTION 7 FLANGE FRAME WIND W 7/ FLANGE FRAME WINDOW FLANGE FRAME WINDOW NOTES: 1. SLIDE CLIP INTO LOCATION AND SECURE WITH ITEM 19(QTY 2),AS SHOWI 2. PRE-DRILLED HOLES(THRU H/V CLIP 1897),BY THE INSTALLER, MAY BE LOCATED AS NEEDED WHILE MAINTAINING A MINIMUM CLIP EDGE OF 9/32"AND A MINIMUM CENTER TO CENTER SPACING OF 1/2". - 3. THE ABOVE SECTIONS APPLY TO ALL MULLBAR-TO-MULLBAR CONNECTIOI REGARDLESS OF ORIENTATION(i.e.,HORIZONTAL OR VERTICAL). THE FUL MULL MUST BE THE SAME DEPTH,OR GREATER,THAN THE INTERSECTINC WlaaW01sysTEms �1 1900 SW 44TH AVE. OCALA,FLORIDA 34474 . W W W.CWS.CC TRANSOM OVER TWIN TRANSOM OVER TRIPLE TWIN TRIPLE HORIZONTAL MULLION 3" PVC VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION I MULL BAR NON-IMPACT.ui .: T x x w C9 ISINGLEI J J Z I TWIN OR I T n w v QL J J _ a- ITRIPLEI o O UNITS Y u_ L ELO U) L IB WI w � m II II I I U U Z Fes— OPENING SIZE—, ." OPENING SIZE F- OPENING SIZE--i OPENING SIZE I- F-- MULL LENGTH m m O v o UQ 0 0 >I (y N z w cc cc 0 E E� a j wwCC C) 0 0 U) w > > o I co ¢ 0I `���unrirgrr I PrIDRE4y v. N14_ o /' STATE OF 4(•k/�� / 0R10P���`. _ION LOCATION;ATTACH WINDOW UNIT(S)TO MULLBAR THRU FRAME AS SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENTS.IF ALUMINUM ATTACHMENT IS NOT SPECIFIED IN THE WINDOW UNIT APPROVAL �rrrrrtenrl���� ENTS,FOLLOW THE ANCHOR SPACING AS INDICATED IN THE WINDOW APPROVAL FOR ATTACHMENT TO WOOD SUBSTRATE,USING A HEX WASHER HEAD TEK SCREW OF THE SAME SIZE(#10 OR#12)AS THE y r� SCREW INDICATED IN THE WINDOW APPROVAL.TEK SCREWS SHALL BELONG ENOUGH TO ENSURE THREE(3)THREADS OF PENETRATION BEYOND THE INSIDE WALL OF MULLBAR. 27 4/27/2015 _IP INSTALLATION ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 9. LUCAS A.TURNER,P.E. _E'CL'IP"INSTALLATION"ANCHORS•MUSTBE•MADE OF OR PROTI=CTED'WITH A CORROSION FiESIS-I-ANT MATERIAL'OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED FL PE# RUST BE PROTECTED TO PREVENT REACTION. 1239 JABARA AVE.A NORTH PORT,FL 34288. ATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH.STRENGTHS LESS THAN THE PH.941-380-1574 0 SPECIFIED IN TABLE 1,SHEET 9. SHEET DESCRIPTION: 3 EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR.STUCCO: FOR•CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS;IF USED,INTO SUBSTRATE-1 X BUCKS CONFIGURATIONS AND TIONAL. ANCHORAGE NOTES UM CENTER-TO-CENTER SPACING-SHALL BE MAINTAINED AS INDICATED BY THE PRE-DRILLED HOLES AS SHOWN IN THE CLIP LAYOUTS ON SHEETS 4-5. DRAWN BY: DATE: RS 04/13/09 )R MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED'BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER-WIND LOADS TO THE STRUCTURE. _DwG u: REv.: ATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLEI;.SHEET 9. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-430 B i AND FJ_ASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET AMA-100(FIN.WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS),FMA/AAMA/WDMA 300(EXTERIOR DOORS) 1:1 8 OF 10 f I I I RETRO FIT "L"ANGLE MULL BAR CLIP MULL BAR CLIP TWO REQ'D PER EACH END OF MULL MULL BAR MULL BAR i INSTALLATION ANCHOR INSTALLATION ANCHOR 1 SEE TABLE 1 SEE TABLE 1 ADD STRUCTURAL ELEMENTS ADD STRUCTURAL ELEMENTS SEALANT ALONG —� AS REQ'D TO MAKE LEVEL FOR. SEALANT ALONG = AS REQ'D TO MAKE LEVEL FOR OUTSIDE EXPOSED — MULL BAR OUTSIDE EXPOSED MULL BAR EDGE BY INSTALLER EDGE BY INSTALLER PERIMETER SEALANT PERIMETER SEALANT BY INSTALLER MIN.EMBEDMENT BYINSTALLER MIN.EMBEDMENT INSIDE AND OUT SEE TABLE 1 INSIDE AND OUT SEE TABLE 1 SUBSTRATE BY OTHERS SUBSTRATE BY OTHERS SEE TABLE 1 SEE TABLE 1 MIN.EDGE DIST. I MIN.EDGE DIST. SEE TABLE 1 SEE TABLE 1 VERTICAL SECTION. E VERTICAL SECTION 9 TYPICAL FLANGE(RETRO FIT)ANCHORAGE' 9 TYPICAL FLANGE("L"ANGLE)ANCHORAGE HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION NOTES: TABLE 1:APPROVED MULL CLIP INSTALLATION FASTENERS 1.BOX FRAME MULL INSTALLATION SIMILAR TO FLANGE FRAME. BSTRATETYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. 2.SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS CONCRETE(2.0K . 3/16"ITW TAPCON 1" 3" AFTER INSTALLATION. CONCRETE( . .) 3/16"ELCO ULTRACON 1-3/4" 1" 3.RECESS RETRO MULLION CLIP 3/8"MAX.FOR CLEARANCE OF WINDOW HOLLOW or GRQUT-FILLED CMU(ASTM C-90). 1/47ELCO ULTRACON. 1-1/4" 2-1/2" UNIT AS NEEDED. ' 2X MIN.SOUTHERN PINE(G=0.55) 3/16"ITW TAPCONOR.ELCO ULTRACON 1-3/8 7/8 4.FOUR(4)ANCHORS REQUIRED PER"T"MULL CLIP,SEE SHEET 2. 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8'. TWO(2)or THREE(3)ANCHORS REQUIRED PER"L"MULL CLIP,SEE SHEETS 2-3. 16 GAUGE(0.060")MIN.STEEL STUD #10716 HILT]KW IK-FLEX OR ITW FULL THREAD 5.SEAT MULLION TIGHT TO MULL CLIP.. (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" . 7/16 1/8"ALUM.(6063-T5 MIN.)OR #10 GRADE 5SELF-TAPPING/ FULL THREAD 6.FOR ANCHORAGE DETAILS FOR THE WINDOW,REFER TO THE WINDOW 7/16" SPECIFIC INSTALLATION DETAILS: 1/8"STEEL(33 KSI MIN.) ..' DRILLING SCREW 7HRU 0.125" i INDON SYSTEMS I 1900 SW 44TH AVE. OCALA,FLORIDA 24474 www.cws.cc 3" PVC MULL BAR NON-IMPACT �2 RETRO FIT ••L"ANGLE CLIP r T _ _ T w MULL BAR CLIP .' -'. -- • TWO REO'D PER EACH END OF MULL � o r o Y MULL BAR - MULL BAR w W I— Do — — Q') INSTALLATION ANCHOR INSTALLATION ANCHOR w LL O SEE TABLE 1,.SHT 9 Q SEE TABLE 1,SHT 9 ,p o pinW W SEALANTALONGE - SEALANT ALONGE OUTSIDE EXPOSEDo — OUTSIDE EXPOSED a EDGE BY INSTALLER , EDGE BY INSTALLER °' a I w w M EXTERIOR FINISH o° MIN.EMBEDMENT EXTERIOR FINISH °°°�1; MIN.EMBEDMENT o o cn BY OTHERS ° o i SEE TABLE 1,SHT 9 BY OTHERS °• !v SEE TABLE 1,SHT 9 _ o PERIMETER SEALANT o o° PERIMETER SEALANT o o° BY INSTALLER BY INSTALLER m ¢ p INSIDE AND OUT INSIDE AND OUT Z SUBSTRATE BY OTHERS - SUBSTRATE BY OTHERS ��runrrir SEE TABLE 1,SHT 9 SEC TABLE i,SHT 9 oO. . o F- F--------j--MIN.EDGEDIST. ° / MIN.EDGE DIST. �� Py �YOENSc'•� SEE TABLE 1,SHT 9 SEE TABLE 1,SHT 9 `� F VERTICAL SECTION G VTICAL SECTION y; No 58201 10 TYPICAL FIN RETRO FIT)ANCHORAGE 10 TYPICALERFIN("L"ANGLE)ANCHORAGE HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION * t = 90;• STATE OF = I S Z&'f ON 4/2015 _ LUCAS A.TURNER,P.E. j NOTES: FL PE#58201 1239 JABARA AVE. 1.SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS NORTH PORT,FL 34288 AFTER INSTALLATION. PH.941-380-1574 SHEET DESCRIPTION: 2.RECESS RETRO MULLION CLIP 3/8"MAX.FOR CLEARANCE OF WINDOW UNIT AS NEEDED. INSTALLATION DETAILS FIN 3.FOUR(4)ANCHORS REQUIRED PER"T"MULL CLIP,SEE SHEET 2. TWO(2)or THREE(3)ANCHORS REQUIRED PER"L"MULL CLIP,SEE SHEETS 2-3. DRAWN BY: DATE: RS 04/13/09 4.SEAT MULLION TIGHT TO MULL CLIP. DWG a: REV.: —i 5.FOR ANCHORAGE DETAILS FOR THE WINDOW,REFER TO THE WINDOW CWS-430 B SPECIFIC INSTALLATION DETAILS. SCALE: SHEET 1:2 10 OF 10