HomeMy WebLinkAboutProduct Approval r ,
M�IAMI•DADE 1VIIAMI-DARE COUNTY
d2 _ PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) mvw.miamidade.eov/economy
CertainTeed Corporation
1400 Union Meeting Road, P.O. Box 1100
Blue Bell,PA 19422-0761
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
.used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the. expense of such testing and the AHJ may inunediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
r
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code \(J
including the High Velocity Hurricane Zone of the Florida Building Code. 1�
DESCRIPTION: CertainTeed Modified.Bitumen Roofing Systems over Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,_Florida, and followed by_the_
expiration date inay be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA##I3-0204.03 and consists of pages 1 through 16.
The submitted documentation was reviewed by Alex Tigera.
(I�
MIAMI•DADE COUNTY
'r NOA No.: 14-0224.03
i Expiration Date: 06/19/18
Approval Date: 04/10/14
Page-1 of 16
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Category: Modified Bitumen
Material: APP/SBS
Deck Tyne: Wood
Maximum Design Pressure: -60 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
All Weather/Empire Base 36"x 65'10"; ASTM D 4601 Type Asphalt coated, fiberglass reinforced
Sheet Roll weight: 86 lbs. U base sheet
(2 squares) UL Type 15
Flex-I-Glasrnl Base Sheet 36"x 98'9";RolI ASTM D 4601,Type Modified Bitumen coated fiberglass
weight:90 lbs. II base sheet.
(3 squares) UL Type G2
Flex-I-GlasTm FR Base Sheet 39 3/$" x 50;Roll ASTMD 6163, Modified Bitumen coated fiberglass
weight:90 lbs. Grade S,Type I base sheet.
(1.5 squares)
'lintglas, PI Sheet Type IV 36"x 164'7"; Roll ASTM D 2178 Type Fiberglass,asphalt impregnated ply
or V1 weight:40/55 lbs. IV or VI sheet.
(5 squares) UL Type G
Flintlastic STA 39 3/s" x 33; Roll ASTM D 6222, Smooth surfaced APP Modified
weight:90 lbs. Grade S,Type II Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for torch
application.
Flintlastic GTA;GTA-FR 39 3/8" x 33'3";Roll ASTM D 6222, Granule surfaced APP Modified
weight: 105 lbs. Grade G,Type II Bitumen membrane with non-woven
(I square) polyester mat reinforcement for torch
application.
Flintlastic GMS 39 3/8" x 34'2"-,Roll ASTM D 6164, Granule surfaced SBS Modified
GMS Premium weight: 100/105 lbs. Grade G,Type II Bitumen membrane with non-woven
(1 square) polyester mat reinforcement f_or_m_op
application.
Flintlastic FR, 39 3/8"x 34'2"; Roll ASTM D 6164, Fire resistant,granule surfaced SBS
FR-P Premium weight: 105 IUs. Grade G,Type I Modified Bitumen Membrane with
(1 square) non-woven polyester mat
reinforcement for mop application.
Flintlastic FR Cap Sheet 39 3/$"x 34'2";Roll ASTM D 6163, Fire resistant,granule surfaced SBS
weight:90 lbs. Grade G,Type I Modified Bitumen membrane with
(1 square) fiberglass mat reinforcement for mop
applications.
MIAMI•DADE COUNTY
NOA No.: 14-0224.03
Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 2 of 16
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
Flintlastic FR Cap T 39-3/8"x 34'2";Roll ASTM D6163 Granule surfaced SBS Modified
weight: 81 lbs. Bitumen membrane with fiberglass
(1 square) mat reinforcement for torch
application.
Flintlastic FR Base T 39-3/8"x 33'; Roll ASTM D6163 Modified Bitumen,coated fiberglass
Weight: 81 lbs. base sheet for torch application.
(1.0 squares)
Flintlastic FR Cap CoolStar 39 3/6"x 34'2"; Roll ASTM D 6163 Fire resistant,granule surfaced SBS
weight: 90 lbs. Modified Bitumen membrane with
(I square) fiberglass mat reinforcement for mop
applications. Covered with reflective
CoolStar Coating.
Flintlastic FR Cap T CoolStar 39 3/3" x 34'2";Roll ASTM D 6163 Fire resistant,granule surfaced SBS
weight: 90 lbs. Modified Bitumen membrane with
(1 square) fiberglass mat reinforcement for mop
applications. Covered with reflective
CoolStar Coating.
Flintlastic GTA,GTA-FR 39 3/3"x'33'3";Roll ASTM D 6222 Granule surfaced APP Modified
CoolStar weight: 105 lbs. Bitumen membrane with non-woven
(I square) polyester mat reinforcement for torch
application. Covered with reflective
Cool Star Coating.
Flintlastic GMS/GMS 39 3/6"x 34'2"; Rall ASTM D 6164 Granule surfaced SBS Modified
Premium Coo)Star weight: 100/I05.lbs. Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for mop
application. Covered with reflective
CoolStar Coating.
Flintlastic FR-P/FR-P Premium 39 3/3" x 34'2"; Roll ASTM D 6164 Fire resistant,granule surfaced SBS
CoolStar weight: 105 lbs. Modified Bitumen Membrane with
(I square) non-woven polyester mat
reinforcement for mop application.
_ Covered with reflective CoolStar
Coating. Covered with reflective
CoolStar Coating.
Ultra Poly SMS 36"x 64'4" ASTM D 6164, Smooth surfaced SBS Modified
(2 squares) Grade S,Type I Bitumen Membrane with non-woven
polyester mat reinforcement for mop
applications.
MIAM1•DADMEC OUNTY NOA No.: 14-0224.03
Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 3 of 16
GlasBaseT'11 Base Shee 36"x 98'9"; Roll ASTM D 4601 Asphalt coated,fiberglass base sheet.
weight:69 lbs. UL Type 02
(3 squares)
PolySMS Base Sheet 39'/s" x 64'4";Roll ASTM D 4601, Modified Bitumen coated polyester
weight:90 lbs, Grade S,Type 11 base sheet.
(2 squares) UL Type 02
Yosemite@ Buffer Base Sheet 36"x 32'1.0";Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced
weight:90 lbs. ASTM D 4897 buffer sheet.
(I square) UL Type 30
Black DiamondTM Base Sheet 36"x 687';Roll ASTM D 1970 Self-adhering fiberglass reinforced
weight: 78 lbs. modified bitumen base sheet
(2 squares)
APPROVED INSULATIONS:
TABLE
Product Name Product Description Manufacturer
(With Current NOA)
FlintBoard ISO Polyisocyanurate foam insulation CertainTeed Corporation
ACFoam-11 Polyisocyanurate foam insulation Atlas Roofing Corporation
High Density Wood Fiberboard Wood fiber insulation board Generic
Perlite Insulation Perlite insulation board Generic
DensDeck,DensDeck Prime Water resistant gypsum board Georgia Pacific Gypsum LLC
H-Shield Polyisocyanurate foam insulation Hunter Panels LLC
ENRGY 3, ENRGY 3 25 PSI Polyisocyanurate foam insulation Johns Manville Corp.
Multi-Max FA-3 Polyisocyanurate foam insulation RMax Operating,LLC
APPROVED FASTENERS:
TABLE
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
1. None N/A None N/A
NOA No.: 14-0224.03
Ty Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 4 of 16
EVIDENCE SUBMITTED:
Test Mency/Identifier Name Report Date
Factory Mutual Research Corp. FMRC 4470 J.I. 3YSAI.AM 03/23/96
FIVIRC 4470 J.I.OD3A3.AM 04/04/97
FMRC 4470 J.I.2DOAO.AM 12/23/98
FNIRC 4470 Ll. I D7A4.AM 11/09/98
Underwriters Laboratories, Inc. UL 790 R11656 01/111/11)
United States Testing Company ASTM D 5147 97457-4 06/03/88
ASTM D 5147 97-457-2R 12/02/87
Momentum Technologies, Inc. ASTM D 4601 AX3 I G81) 09/05/08
ASTM D6164 AX3 I G8F 06/05/09
ASTM D6222 AX3 I G8G 06/05/09
ASTM D 3909/D 4897 AX31 G8C 09/05/08
TrinitylERD TAS 114(J) #3504.06.01-1 06/05/01
TAS 117(B) .3503.10.06 10/10/06
TAS 117(B) 06490.04.07-R1 06/27/07
TAS 114(H) Letter 04/05/06
TAS 114 3533.01.06 01/06/06
TAS 114 3521.07.04 07/29/04
TAS 117(B)/ASTM D 6862 C8500SC.11.07 11 r30/07
TAS 114 C8370.08.08 08/19/08
ASTM Physical Properties C10080.09.08-R4 03/25/10
ASTM D6164/D4798 031410.01.11-2 01/10/11
ASTM D4601 040050.09.12-1 09/28/12
ASTM D1970 040050,09.12-2 09/28/12
ASTM D5147/D4798 C31410.10.10-R1 11/01/12
ASTM D5147/D4798 C31410,01.11-1-RI 11/01/12
ASTM D4798 C3]410.01.11-2A-RI 02/21113
ASTM D4798 C31410.12.13 12/05/13
ASTM D6222 C40050.12.13 12/05/13
PRJ Construction Materials ASTM D6163 CTC-032-02-01 01/22/08
Technologies LLC ASTM D6163 CTC-066-02-01 08/09/11
ASTM D6164 CTC-068-02-01 08/09/11
ASTM D6222 CTC-070-02-01 08/09/11
ASTM D6164/D4798 CTC-093-02-01 08109/11
ASTM! D2178 CTC-122-02-01 03/13/12
ASTM D2178 CTC-123-02-01 03/13112
ASTM D4601 CTC-127-02-01 03/13/12
ASTM D6163 CTC-128-02-01 06/11/12
ASTM D6163 CTC-129-02-01 06/11/12
ASTM D6164 CTC-132-02-01 06/t 1/12
ASTM D6164 CTC-162-02-01 05/09113
ASTM D6164 CTC-161-02-01 05/091113
ASTM D6162 CTC-183-02-01 10/02/13
ASTM D6164 CTC-190-02-01 12/02/13
NOA No.: 14-0224.03
XMIAMI-DADECOU�j� Expiration Date: 06/19/18
Approval Date: 04110114
Page 5 of 16
Membrane Type: SBS Modified
Decl(Type 11: Wood,Non-Ins ated
V,
Deck Description: Minimum "/,,"thick plywood attached using approved nails spaced 4"o.c.at wood joists
spaced maximum 24"o. c
System Type E(4): Base sheet mechanically fastened.
All General and, System Limitations apply.
( Base Sheel: <Oanicneply f All Weather/Empire Base Shecl(EBase or Ftintglas Premium Ply Sheet(Type VI)
ril,
mee ally attached as detailed below.
fFastening: Base sheet shall be lapped 4" and fastened with 11 ga.annular ring shank nails and approved tin
1111� caps 8"o* .c.in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sh:eet: (Optional)One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flo Q I asr
' Z V
2 Base,Flex-I Glas FR Base or Poly SMS or 2.ae or more plies of T 0
Flintglas Premium Ply Sheet(Type VI)adhered in a full mopping of approved asphalt Flo
within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet
self-adhered or Flintlastic STA torch adhered,
Membrane: D
One pl of lintlastic GMS Flintlastic GMS CoolStar,Flintlastic Premium GMS,Flintlastic
<Ze p
Premium G3 T,Flintlastic FR-P, Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,
Flintlastic Premium FR-P CoolStar,Flintlastic FR Cap Sheet,Flintlastic FR Cap Sheet CoolStar
adhered to ply sheet with approved mopping asphalt applied within the EVTrange and at a rate
of 20 to 40 lbs./sq. or Flintlastic FR Cap T or Flintlastic FR Cap T CoolStar torch adhered to
ply sheet.
Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA.
Install one of the-following:
1. 400-1b./sq.gravel or 300-1b./sq.slag in a flood coat of approved mopping asphalt at an
application rate of 60 lb./sq.
2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,FlintCoat A-150,APOC 9212
ibrated Aluminum Roof Coating at an application rate of I Va gal./sq
Maximum Design
Presspre: -60 psf.(See General Limitation#7)
NOA No.: 14-0224.03
12NTY Expirition Date: 06/19/18
Approval Date: 04/10/14
Page 15 of 16
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings ofthis product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 2040 lbs./sq.,or mechanically attached using the fastening pattern of the top-layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4'x 4'maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in.each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf.
5. Fastener spacing For insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf,as
tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested,are below
275 lbf.insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anobor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing,
prepared,signed and sealed by a Florida registered Professional Engineer,Registered Architect,or Registered
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117.
,/7, Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA,General Limitation#9 will not be applicable.)
8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing tertnination designs shall conform to
Roofing Application Standard RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e.field,
perimeters,and comers).Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressurezones(i.e. perimeters,extended corners and comers).(When this limitation is specifically
referred within this NOA,General Limitation#7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
KfM MIA M!-MD Ell I am M NOA No.: 14-0224.03
Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 16 of 16