Loading...
HomeMy WebLinkAboutProduct ApprovalFlorida Building Code Online Page 1 of 4 Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin, MO 64802 (417) 624-6644 Ext 2305 kerri_eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Test Report Testing Lab PRI Construction Materials Technologies, LLC Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 02/26/2016 Validated By Robert J. M. Nieminen, PE J Validation Checklist - Hardcopy Received Certificate of Independence FL12328 R3 COI PRI CMT Cert of Indeoendence.pdf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2001 ASTM D226 2006 ASTM D4869 2005 ASTM D6380 2003 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option B htti)://www.floridabuildinQ.orQ/Dr/Dr abn dtl.asbx?naram=wGEVXOwtDatF2AezuarigOl... 5/15/2014 D�'eparr ri're t BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Susi ICJ 3 �Product rof essi h Approval OUSER: PublicUser Regulation _ . . , •., Product Approval Menu > Product or Application Search > Application List > Application Detail sA I FL # FL12328-R3 e Application Type Editorial Change Code Version 2010 Application Status Approved Comments Archived Product Manufacturer TAMKO Building Products, Inc. Address/Phone/Email PO Box 1404 Joplin, MO 64802 (417) 624-6644 Ext 2305 kerri_eden@tamko.com Authorized Signature Kerri Eden kerri_eden@tamko.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin, MO 64802 (417) 624-6644 Ext 2305 kerri_eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Test Report Testing Lab PRI Construction Materials Technologies, LLC Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 02/26/2016 Validated By Robert J. M. Nieminen, PE J Validation Checklist - Hardcopy Received Certificate of Independence FL12328 R3 COI PRI CMT Cert of Indeoendence.pdf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2001 ASTM D226 2006 ASTM D4869 2005 ASTM D6380 2003 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option B htti)://www.floridabuildinQ.orQ/Dr/Dr abn dtl.asbx?naram=wGEVXOwtDatF2AezuarigOl... 5/15/2014 Florida Building Code Online Date Submitted 03/04/2013 Date Validated 03/11/2013 Date Pending FBC Approval 04/15/2013 Date Approved 06/11/2013 Summary of Products Page 2 of 4 FL # Model, Number or Name Description 12328.1 ASTM Slate Surfaced Roll Roofing Roll roofing surfaced with mineral granules Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R3 II sl surf app ins.pdf Approved for use outside HVHZ: Yes Verified By: Robert J. M. Nieminen 59166 Impact Resistant: N/A Test Reports Design Pressure: N/A FL12328 R3 TR 2010 Referenced Standards Evaluation for Other: For use on roofs with slopes greater than 2:12. Not TAMKO 10 03 2011.pdf approved for use in HVHZ. Refer to FRSA/TRI 07320/8 for FL12328 R3 TR astm slate surfaced roll rfo.pdf underlayment options with tile roof systems. Impact Resistant: N/A Test Reports 12328.2 ASTM Tile Underlayment Coated organic underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R3 II UNDERLAYMENT.pdf Approved for use outside HVHZ: Yes Verified By: Robert J. M. Nieminen 59166 Impact Resistant: N/A Test Reports Design Pressure: N/A FL12328 R3 TR 2010 Referenced Standards Evaluation for TAMKO 10 03 2011.1)df Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not FL12328 R3 TR astrn tile underlayment report.pdF approved for use in HVHZ. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Maximum 30 day exposure. 12328.3 Master Smooth Asphalt saturated organic underlayment. Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R3 II UNDERLAYMENT.pdf Approved for use outside HVHZ: Yes Verified By: Robert J. M. Nieminen 59166 impact Resistant. N/A Test Reports Design Pressure: N/A FL12328 R3 TR 2010 Referenced Standards Evaluation for Other: For use under discontinuous roofing systems i.e. TAMKO 10 03 2011.1)df asphalt shingles with slopes greater than 2:12. Not FL12328 R3 TR master smooth reportpdf approved for use in HVHZ. Not for use as a substrate for adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Maximum 30 day exposure. 12328.4 Moisture Guard Plus A self -adhering modified bitumen underlayment. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL12328 R3 II mqp app inst.pdf Verified By: Robert]. M. Nieminen 59166 Impact Resistant: N/A Test Reports Design Pressure: N/A FL12328 R3 TR moisture guard plus report.pdf Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not approved for use in HVHZ. Not for use as a substrate for adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Maximum 90 day exposure. 12328.5 Nail Fast SBS modified utility underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R3 II nailfast app ins.odf Approved for use outside HVHZ: Yes Verified By: Robert J. M. Nieminen 59166 Impact Resistant: N/A Test Reports Design Pressure: N/A FL12328 R3 TR 2010 Referenced Standards Evaluation for TAMKO 10 03 2011.pdf Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not FL12328 R3 TR nailfast report.pdf approved for use in HVHZ. Not for use as a substrate for adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Maximum 30 day exposure. 12328.6 I No. 15 ASTM D4869 I Asphalt saturated organic felt Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not Installation Instructions FL12328 R3 II UNDERLAYMENT.odf Verified By: Robert]. M. Nieminen 59166 Test Reports FL12328 R3 TR no 15 astm d4869 report.cid http://www.floridabuildin2.oria/pr/Dr app dtl.aSnx?naram=wGEVXOwtDatF2Ae7.uarig01___ 5/150014 Florida Building Code Online Page 3 of 4 approved for use in HVHZ. Not for use as a substrate for adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Shall be covered as soon as possible after installation; exposure for more than 24 hours could affect performance. 12328.7 No. 15 UL Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R3 II UNDERLAYMENT.Ddf Approved for use outside HVHZ: Yes Verified By: Robert J. M. Nieminen 59166 Impact Resistant: N/A Test Reports Design Pressure: N/A FL12328 R3 TR no 15 UI report.odf Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not approved for use in HVHZ. Not for use as a substrate for adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Shall be covered as soon as possible after installation; exposure for more than 24 hours could affect performance. 12328.8 No. 30 ASTM Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R3 II UNDERLAYMENT.odf Approved for use outside HVHZ: Yes Verified By: Robert J. M. Nieminen 59166 Impact Resistant: N/A Test Reports Design Pressure: N/A FL12328 R3 TR no 30 astm report.pdf Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not approved for use in HVHZ. Not for use as a substrate for adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Shall be covered as soon as possible after installation; exposure for more than 24 hours could affect performance. 12328.9 No. 30 ASTM D4869 Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R3 II UNDERLAYMENT.odf Approved for use outside HVHZ: Yes Verified By: Robert J. M. Nieminen 59166 Impact Resistant: N/A Test Reports Design Pressure: N/A FL12328 R3 TR no 30 astm d 4869 reoort.0df Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not approved for use in HVHZ. Not for use as a substrate for adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Shall be covered as soon as possible after installation; exposure for more than 24 hours could affect performance. 12328.10 No. 30 UL Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R3 II UNDERLAYMENT.odf Approved for use outside HVHZ: Yes Verified By: Robert J. M. Nieminen 59166 Impact Resistant: N/A Test Reports Design Pressure: N/A FL12328 R3 TR no 30 ul report.pdf Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not approved for use in HVHZ. Not for use as a substrate for adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Shall be covered as soon as possible after installation; exposure for more than 24 hours could affect performance. Baric Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Ed im Ki -- securitv.miM tcsmom - htti)://www.floridabuildina.oriz/nr/nr anti dtl.asnx?naram=wGEVXOwtDatF2Ae7.IlnriPlOI 5/15/2014 Florida Building Code Online Page 4 of 4 littp://www.floridabuildin2.or2/Dr/Dr aDD dtl.asnx?naram=wGEVXOwtDatF2AezuarigO1... 5/1.5/2014 BUILDING PRODUCTS LINDERL AYMENT: An underlayment consisting of asphalt saturated felt must be applied over the entire deck before the installation of TAMKO shingles. Apply the felt when the deck is dry. On roof decks 4 in. per foot and greater apply the felt parallel to the eaves lapping each course of the felt over the lower course at least 2 in. Where ends join, lap the felt 4 in. If left exposed, the underlayment felt may be adversely affected by moisture and weathering. Laying of the underlayment and the shingle application must be done together. CORPORATE HEADQUARTERS 220 W. FOURTH STREET P.O. BOX 1404 JOPLIN, MO 64802-1404 800-641-4691 tamko.com