Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 & " h: F�Otlt c Ck x�Izfl t£ SCIS Home ; Log In 1 User Registration Hot Topics i Submit Surcharge Stats&Facts I Publications FBC Staff ; BCIS Site Map Unks s*Search I Busines����bl'l g " Product ApprovalProfesi USER: Public User Regulation Ct1 Product Approval Menu>Product or Application Search>Application List>Application Detail a� ,a, ^..��: «a nP FL# FL10674-R11 MAS 21 Application Type Revision Code Version 2014 PERMITTING Application Status Approved St. Lucie County; FL Comments Archived i,„i Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeter@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer n Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert I.M.Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W. Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R11 COI 2015 01 COI Nielttinen.odf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Sections from the Code https:Hfloridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT... 3/17/2016 Florida Building Code Online Page,2 of 2 Product Approval Method Method 1 Option D Date Submitted 10/15/2015 Date Validated 10/19/2015 Date Pending FBC Approval 10/20/2015 Date Approved 12/15/2015 Summary of Produ cts FL# Model,Number or Name Description 10674.1 Owens Coming Asphalt Roofing 3-tab,4-tab,5-tab, laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL1�Fi7 R11 12Q:L,5. it3_FINAL E_9_9_C..A5PHALT Approved for use outside HVHZ: Yes SHINGLES Fl10674-R11 Ddf Impact Resistant: N/A Verified By: Robert].M.Nieminen PE- 59166 Design Pressure:N/A Created by Independent Third Party:Yes Other: Refer to ER, Section S. Evaluation Reports FL10674 R11 AE 2.015 10 FINAL ER OC_ASPHALT SHINGLES FL10674-R11j)df Created by Independent Third Party:Yes back Nexk Contact Us::1940 North Monroe Str et Tallahass Fl.3239 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida ::Privacy Statement::Accessibiftty Statement;:RgUnd Statement Under Florida law,emali addresses are publicrecords.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 45S.275(l),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ":a 0 99 si:ctttitvar r;rexres" https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT... 3/17/2016 EXTERIOR'RESEARCH&DESIGN, LLC. Certificate of A uthorizotion#9503 TRINITY 1 ERD 353 CHRISTIAN STREET,UNIT#13 1 OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-116 One Owens Corning Parkway FL10674-RII Toledo,OH 43659 Date-of Issuance:02/06/2012 Revision 6: 10/15/2015 SCOPE: This Evaluation Report is issued under Rule. 61G20-3 and the applicable rules and .regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation. Report is valid until such time as the named produet(s) changes, the referenced Quality Assurance documentation changes;or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the productchanges or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT.: The Evaluation Report number preceded by the words "Trinity.IERD Evaluated" may be displayed in advertising.literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION:Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the..job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: Robert J.M.Nieminen,P.E. �'�; '' t}tC r�='p: The facsimle seal appearing was authorized by Robert Nleminen, 'i �sO° AC- a'�": P.E.on 10/15/2015.This does not serve as an electronically signed FlondoRegistration.No.59166,Florida DCA ANE1983 document Signed,sealedhardoopleshave beentransmlttedtothe Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing,products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial'interest in any Company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial.interest in any other entity involved in the approval.process of the product. 5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen,P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. C)o TRINITY I ERD.. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt.Sh ingles Compliance Statement: Owens Corning.Asphalt Roof.Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to:the Installation Requirements and Limitations/Conditions-of Use set forth herein. 2. STANDARDS: Section Prove Standard Year 1507:2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507:2.7.11 R905.2.6.1 Wind Resistance ASTM..D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind.Resistance File R2453,Vol.3 02/15/2007 UL LLC"(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34309 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC-(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02'/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC(QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCTDESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4:1.3 Devonshire T"are,fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration TruDefinition' Duration®, Duration®Premium Cool, TruDefinition® Duration' Designer Color Collection,Tru Definition"Oakridge,Oakridgee and WeatherGuard HP are fiberglass reinforced,laminated asphalt roof shingles. 4.2 Berkshire' Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard' HP Hip & Ridge Shingles,ProEdge Hip&Ridge Shingles and DuraRidgeTM' Hip &Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip.Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained.speclficaIly for that purpose. 5.2 This Evaluation Report is not.for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report, refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and.Design,LLC. Evaluation Report 037940:02.12-R6 eertiflcate of Authorkation#9503 FL16674-R11 Revision 6:10/15/2015 Page 2 of 7 TRINITY j ERD 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM'D3161,Class F and/or ASTM D7158,Class H,indicating the shingles.are acceptable for us in all wind zones up to Vasd=150 mph(Volt= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and StarterStrip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and 11005.2.6:1 to ASTM;D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vasd= 150 mph (V„It 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies:to exposure category B'or C and a building:height of 60 feet or less. Calculations. by a qualified design, professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance.and installation,limitations. 5.5 All products in the roof'assernbly shall have quality assurance audit in accordance .with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning,and shall hold current Florida Statewide Product. Approval,or be Locally Approved per Rule 61620-3,per FBC Sections 1507.2.3;1507.2.4 or 11905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's.current published instructions; using. minimum four(4) palls per shingle in accordance with.FBC Sections 1507,2 or R905.2,with the.following exceptions: Berkshire"shingles require minimum five(S)nails per shingle. WeatherGuard®HP shingles require minimum six(6)nails per shingle. Devonshire'""shingles.require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus.require minimum five(5)nails per strip.. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6:2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing:—Starter Strip Shingle and Starter Strip Plus: FeltundeflaymeM Deck Feltuniledayment. Deck SckS elf—a deod Sett-adhered unSerleyme Weatherl.ock' underlayment �. Drip;_, ' Drip edge Qrtp_: Drip edge edge Nails locatedNa looted nom Cave 2=3"from says Install first Selfsealin adhesive Sd( n adhesive Sterter Strip gg Imta�6tststatter strip i�us shingle with positioned along cave w th 6'namoved _._. –-` positelo�rave 6"removed Starter.Strip shingle overhangs eaves and rakes r!i=Ne" Starter S ,p Pbrs overhangs eaves and rapes 114-318• Eicterior Research andOesign,LLC. Evaluation Report 037940:02:12-R6 Certifitate of Authortzatlon.p9503 FL10674R11 Revision 6:10%15/2015 Page 3 of 7 CYD TRIM-TY I ERD 6.2.6 Minimum Nailing—Classic°&Supreme: Normal Mansard.or' Area para Normal Mansard or Area pare Wind Areas High'.Wfnd desvanesrK Wind Areas High Wind deavanes y Aran para'vlantoo narmales Areas vientes fusrtea. Area pare vlentos norniales; Areas vientos fuertes r (Al. i• rs z t6) 2. r ,. IA> 1' t z• i" tt 12 t 121 r• i61- 5"Exposure 6 518"Exposure Exposicidn: Exposlcldn 6.2.7 Minimum Nailing—Berkshire®: Sealard strip "lent strip La Ilia do'gadbr Led rads selkdor 4__i r!--!� �f i.�.4--3 a ,rte- A aft• 8w" 9Yt' 9.W. iiiVf 8Yf' RIP z. llsplialC roofing omnent Cemonto do leeho'de astaito 6.2.8 Minimum Nailing—Devonshire'"': 47 Nails i" r «• e• yr 'r T '7' S r i Nails Ten 1"Spots of Asphalt Roof Cement Exterior Research and.Design,LLC. Evaluation Report 037940:02.12-R6 Certifhnte of Authorkation#9503 FL10674-Rll Revision 6:10%15/2015 Page 4 of 7