HomeMy WebLinkAboutNOAMIAMI-DADE COUNTY
MIAMFDADE PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv
GAF
1 Campus Drive
Parsippany, NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline HV% Timberline Natural Shadow, and Timberline American Harvest®
Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA 13-0419.04 and consists of pages 1 through 6.
The submitted documentation was reviewed by Juan E. Collao, R.A.
606-11
MIAMINOA No.: 14-1022.20
B7 COUNTY • Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Cate¢orv:
Roofing
Sub-Cate¢orv:
Asphalt Shingles
Materials:
Laminate
Deck Tvve:
Wood
SCOPE
This approves GAF Timberline HD®, Timberline Natural Shadow , and Timberline American Harvest®
Shingles as manufactured by GAF as described in Section 2 of this Notice of Acceptance.
PRODUCT DESCRIPTION
Product
Dimensions
Test
Product Description
Specifications
GAF Timberline HD®
13 '/4-x 39 3/8"
TAS 110
Fiberglass reinforced heavy weight asphalt
Manufacturing
roof shingle, with a laminate profile
Locations #1, 2, 3, 4, 5, 6, 7
GAF Timberline Natural
13 '/4"x 39 3/g'
TAS 110
Fiberglass reinforced heavy weight asphalt
Shadow
roof shingle, with a laminate profile
Manufacturing
Locations #1, 2, 3, 4, 5, 6, 7
GAF Timberline American
13 '/4"x39'/8"
TAS 110
Fiberglass reinforced heavy weight asphalt
Harvest®
roof shingle, with a laminate profile
Manufacturing
Locations #2, 4, 5, 6
MANUFACTURING LOCATION
1. Tampa, FL
2. Michigan City, IN
3. Baltimore, MD
4. Myerstown, PA
5. Ennis, TX
6. Tuscaloosa, AL
7. Dallas, TX
NOA No.: 14-1022.20
Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 2 of 6
EVIDENCE SUBMITTED
Test Agencv
Test Identifier
Test Name/Report
Date
Underwriters Laboratories, Inc.
ASTM D3462
I ICA48924
10/24/11
Underwriters Laboratories, Inc
ASTM D3462
I OCA21994
04/22/11
Underwriters Laboratories, Inc
ASTM D3462
I OCA28717
07/26/11
Underwriters Laboratories, Inc.
ASTM D3462
05CA47541
11/10/06
Underwriters Laboratories, Inc.
ASTM D3462
06CA31580
11/30/06
PRI Asphalt Technologies, Inc.
ASTM D3462
GAF -101-02-02
11/02/05
Underwriters Laboratories, Inc.
ASTM D3462
06NK05159
08/09/06
PRI Asphalt Technologies, Inc.
ASTM D3462
GAF -098-02-02
11/08/05
Underwriters Laboratories, Inc.
ASTM D3462
02NK41809
08/11/02
Underwriters Laboratories, Inc.
ASTM D3462
03NK26444
10/17/03
Center for Applied Engineering
ASTM D3462
257989
05/13/97
Underwriters Laboratories, Inc.
TAS 107
OINK45803
04/13/94
Underwriters Laboratories, Inc.
TAS 107
06NK05159
08/09/06
Underwriters Laboratories, Inc.
TAS 107
04NK04273
02/20/04
Underwriters Laboratories, Inc.
TAS 107
05CA42840
11/11/05
Underwriters Laboratories, Inc.
TAS 107
02NK41811
11/11/02
Underwriters Laboratories, Inc.
TAS 107
03CA35209
10/17/03
Underwriters Laboratories, Inc.
TAS 107
04CA13850
08/30/04
Center for Applied Engineering
TAS 100
257989
04/01/97
PRI Asphalt Technologies, Inc.
TAS 100
GAF -044-02-01
01/13/04
PRI Asphalt Technologies, Inc.
TAS 100
GAF -098-02-01
11/08/05
PRI Asphalt Technologies, Inc.
TAS 100
GAF -101-02-01
11/09/05
PRI Asphalt Technologies, Inc.
TAS 100
GAF -116-02-02
03/23/06
PRI Asphalt Technologies, Inc.
TAS -100
ELK -083-02-01
10/16/02
ELK -084-02-01
10/15/02
ELK -085-02-01
10/14/02
ELK -086-02-01
10/24/02
ELK -087-02-01
10/21/02
ELK -088-02-01
10/16/02
ELK -107-02-01
10/09/03
ELK -108-02-01
10/09/03
ELK -109-02-01
10/09/03
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 14-1022.20
Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 3 of 6
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail 'B', attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade
County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 14-1022.20
Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 4 of 6
DETAIL A
COURSE LAYOUT
NOA No.: 14-1022.20
Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 5 of 6
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
39-3/811
(t m)
14-12" - 17-1/2" 14-1/2" - 17-1/2"
(368-445mm) (368-"5mm)
It 6-1/2"-9-1 /2" 6-1/2"-9-1/2"
(156 Mimm) (185- m)
Sia, )4 WG —�--�— • --49--
trr•-atrz°
(a
ENHANCED NAILING PATTERN - six nails per shingle'
required by some local codes and required for enhanced wind coverage on certain products.
See limited warranty for details.
These shingles MUST be nailed a nominal 6" (152mm) from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
END OF THIS ACCEPTANCE
Nail guide line
53/4" - 6-1/4"
(146mm • 159mm)
from bottom of shingle
Self seal
adhesive
on back
NOA No.: 14-1022.20
Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 6 of 6
M IAMF
MICOUNTY
02MI CONTROL
PRODUCT CONTROLL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Sheet, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv
GAF
1 Campus Drive
Parsippany, NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Cobra Ridge Runner' Exhaust Vent for Roof Ridge
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA#13-0604.06 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera-
l* r
NOA No.: 14-1022.10
Expiration Date: 11/01/17
Approval Date: 01/29/15
Page 1 of 4
ROOFING COMPONENT APPROVAL
Category:
Roofing
Sub -Category:
Ventilation
Material:
Plastic
Minimum Slope:
3:12
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT
Product Dimensions Test Product
Specification Description
GAF Cobra® Ridge 20' Length (Roll) TAS 100 Low profile attic ridge vent in roll form for
Runnefm Exhaust 11.5" Width installation under ridge shingles.
Vent for Roof Ridge .7" Height
MANUFACTURING LOCATION
1. Cumming, GA.
EVIDENCE SUBMITTED
Test Agency/Identifier
Name
Report
Date
ETC Laboratories, Inc.
ASTM D 1929
ETC -07-718-19959.0
09/27/07
ASTM D635
ETC -07-718-19959.0
09/27/07
ASTM D 2843
ETC -07-718-19959.0
09/27/07
PRI Construction Materials Technologies, Inc.
ASTM G 26
GAF -138-02-06
02/09/07
TAS 100(A)
GAF -138-02-04
02/09/07
TAS 100(A)
GAF -439-02-01
05/21/13
MIAMINOA No.: 14-1022.10
rm COUNTY 0=1
• , � � Expiration Date: 11/01/17
Approval Date: 01/29/15
Page 2 of 4
APPROVED APPLICATIONS
Tradename: GAF Cobra Ridge RunnerTm Exhaust Vent for Roof Ridge
System Type: Mechanical attachment of ridge vent.
Slot: Determine whether the rafters are truss or ridgepole construction. Chalk a cut line of
each side of ridge. Cut a 1 3/4" (no ridge board) or 3'/4" (ridge board) maximum slot
along the apex of the roof by cutting 7/8" (no ridge board) or 1%" (ridge board) on each
side of the ridge. The slot shall terminate 1 foot shorter at each end than the total length
of ridge vent used.
Installation: Place, center and conform the end of a piece of ridge vent at each end of slots. Mark the
location of the end of the baffle. Strike a chalk line on both sides of the ridge to produce
baffle alignment. Place vent sections centered over the slot using a chalk line. Place
nails at pre -marked locations on the. Nails shall be minimum 11 guage 1-3/4" corrosion
resistant smooth shank roofing nails, a minimum 3/16" penetration into wood substrate is
required.
Ridge Shingle: Using nail lines provided on top of vent. Nail cap shingles in place, as per ridge cap
shingle manufacturer's installation instructions. Nails shall be minimum I1 gauge 1 3/4"
corrosion resistant smooth shank roofing nails, a minimum 3/16" penetration into wood
substrate is required.
Ventilation Calculations: Refer to manufacturer's published literature
LIMITATIONS:
1. Refer to applicable Building Code required ventilation.
2. Ridge Vent shall comply with applicable Building Code.
3. Ridge Vent shall not be installed on rof mean heights greater than 33 feet.
NOA No.: 14-1022.10
Expiration Date: 11/01/17
Approval Date: 01/29/15
Page 3 of 4
DETAIL A
20' Length
BOTTOM VIEW
1-11.5- Wide 7"
[3E0ENNaX3X=EM -F
END VIEW
TOP VIEW
END OF THIS ACCEPTANCE
MAMFDADECOUMTY
EQ. . 1t
NOA No.: 14-1022.10
Expiration Date: 11/01/17
Approval Date: 01/29/15
Page 4 of 4
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Seal -A -Ridge® and GAF Timbertex® Ridge Cap Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA# 12-01011.14 and consists of pages I through 9.
The submitted documentation was reviewed by Alex Tigers.
NOA No.: 13-0306.08
t41AMMADE eouDnv Expiration Date: 10/17/17
11
IN • ' Approval Date: 08/15/13
Page i of 9
M�IAM11.
MIAbII-DADE COUNTY
CONTROL SECTION
Em
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street. Room 208
11805
Miami. Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION
T (786) 315-2590 F (786) 315-2599
rrww.mimnidadc zovlecononv
NOTICE OF ACCEPTANCE (NOA)
GAF
1361 Alps Road.
Wayne, NJ 07470
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Seal -A -Ridge® and GAF Timbertex® Ridge Cap Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA# 12-01011.14 and consists of pages I through 9.
The submitted documentation was reviewed by Alex Tigers.
NOA No.: 13-0306.08
t41AMMADE eouDnv Expiration Date: 10/17/17
11
IN • ' Approval Date: 08/15/13
Page i of 9
ROOFING ASSEMBLY APPROVAL
CateQolm
Roofing
Sub-Cate¢orv:
Asphalt Shingles
Materials
3 -Tab Perforated
Deck Type:
Wood
SCOPE
This approves GAF Seal-A-Ridge9 and GAF Timbertex® Ridge Cap Shingles as manufactured by GAF as described
in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product
Dimensions
Test
Product Description
Specifications
GAF Seal -A -Ridge® Ridge Cap
12 x 36"
TAS 110
Hip andhi o.clalong the 36" length
perforatiRidgons Zasph It shingle
Shingle
of shingle.
Manufacturing Location #1, 3
GAF Timbertex® Ridge Cap
12" x 12"
TAS 110
fiberglass36 prof prefed abricatedhilt s and ridge
ingle with
Shingle
perforations at 12" sections.
Manufacturing Location #2
PRODUCTS MANUFACTURED BY OTHERS
Product
Product
Size
Manufacturer
Description
PL Polyurethane Roof & Flashing
Sealant
various
Henkel PL
Sealant
NP -1T"
Sealant
various
Sonneborn
MANUFACTURING LOCATION
1. Tuscaloosa, AL.
2. Mt. Vernon, IN.
3. Mobile, AL.
NOA No.: 13-0306.08
NLAMDADEcouNn Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 2 of 9
EVIDENCE SUBMITTED
Test Aaency
Test Identifier
Tt Name/Report
es
Date
PRI Asphalt Technologies, Inc.
TAS 100
ELK-078-02-01
GAF-125-02-01
06/21/02
04/04/06
TAS 100
Underwriters Laboratories, Inc.
ASTM D3462
IICA45079
06CA18074
03/21/12ASTM
06/16/06
D3462
ASTM D3462
12CA30879
02/01/13
TAS 107
I ICA45079
03/21/12
TAS 107
06CA18074
06/16/06
TAS 107
12CA38083
02/26/13
PRI Construction Materials Technologies LLC
TAS 100
GAF-380-02-01
11/06/12
07/12/12
TAS 100
GAF-367-02-01
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. GAF Seal -A -Ridge® and GAF Timbertex® Ridge Cap Shingles shall be limited for use as hip and ridge cap
shingles only.
3. Shall not be installed on roof mean heights in excess of 33 ft.
4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 9N-3 of the Florida Administrative Code.
INSTALLATION
1. GAF Seal -A -Ridge® and GAF Timbertex® Ridge Cap Shingles shall be installed in compliance with Roofing
Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Nailing for GAF Seal -A -Ridge® Ridge Cap Shingles shall be in compliance with Detail 'A' attached.
Exposure and course layout for GAF Seal -A -Ridge® Ridge Cap Shingles shall be in compliance with Detail
'A'.
5. Henkel PL Polyurethane Roof & Sealant or Sonnebom NP-lTM GunGrade must be used in the application of
GAF Seal -A -Ridge® Ridge Cap Shingles as specified in Detail A and GAF TimbertexV Ridge Cap Shingles
as specified in Detail B.
6. Nailing for GAF Timbertexg Ridge Cap Shingles shall be in compliance with Detail 'B' attached. Exposure
and course layout for GAF Timbertex& Ridge Cap Shingles shall be in compliance with Detail 'B'.
NOA No.: 13-0306.08
MIAMIDADE COUNTY Expiration Date: 10/17/17
Approval Date: 08115/13
Page 3 of 9
LABELING
1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County
Product Control Approved".
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 13-0306.08
Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 4 of 9
DETAIL A
GAF Seal -A -Ridge's Ridge Cap Shingles Application Instructions:
(1) Step One — Separate each piece of GAF Seal -A -Ridge Ridge Cap Shingles into three individual
ridge cap shingle pieces at perforations (see Figure 1).
Figure 1
%i' (12 mm)
!2 T
30:i nm:j G' Exposure
r r (169mm)
t r
12'�,— per'om'ed
(305 mm)
36'
(gid mm)
(2) Step Two — Begin laying full ridge cap shingle with a 6-2/3" exposure beginning at the bottom of the
hip or from the end of the ridge opposite the direction of the prevailing wind (see Figure 2).
Figure 2
astener
NOA No.: 13-0306.08
MIAMFDADE COUNTY Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 5 of 9
(3) Step Three — Apply ridge cap using 2 nails per piece 6-5/8" to 7-5/8" back from the exposed end and
1" to 2" up from the edge (see Figure 2 for location of nails). Use only zinc coated steel or aluminum, 10-
12 gauge, barbed, deformed or smooth shank roofing nails with heads 3/8" (9.5mm) to 7/16" (12mm) in
diameter. Nails should be long enough to penetrate at least 3/4" (19mm) into wood decks or just through
plywood decks. Nails must be driven flush with the surface of the shingle. Over driving will damage the
shingle. Raised nails will interfere with the wind resistance of the shingles.
Special Application Section:
For Cold Weather Application
• In cold weather, wane GAF Seal -A -Ridge'° Ridge Cap Shingles before bending.
• When self-sealing is delayed due to cold weather, apply quarter -sized dabs of asphalt plastic
cement (must conform to ASTM D4586 Type I or Type II) between ridge cap pieces and press
firmly to insure good contact between pieces.
• Note: Excessive application of tab adhesive can cause blistering of ridge cap shingle.
For High -Wind Zones
In high wind areas or for maximum wind resistance, apply a two quarter -sized dabs of Henkel
PL' Urethane Sealant to each ridge cap shingle approximatly 9" back from the exposed end and
1" from the shingle edge. (see Figure 3).
Figure 3
9'
(229 mm)
1"
11.M ) Sealant
(292 mm1" �Sellante
5 mm) (25 mrn� Enduit d'6tancheild
A I•
Nail 12,
Clavo (305 mm)
Clouer
12"
(305 mm)
For maximum wind speed coverage under ltd. warranty, appy
additional sealant as shown. See Special Application Section
for specific detais.
Para el akanee ffkWMo de veWdad de viento bajo limdado
garantia, aplica sellador adciord como mostrado. Vea Secci6n
.Especial deAplicaclen para detelles especlT�cos.
Pour la couverture maxdmum de vitesse de vent sous Knit& la garantie,
appliquer de 1'erduit d'6tanchdite supplementaire comme inclquC
Voir h section speciale d'application pour les details sp®cifques.
NOA No.: 13-0306.08
MIAMI-DADE COUNTY Expiration Date: 10/17/17
' ' Approval Date: 08/15/13
Page 6 of 9
DETAIL B
GAF Timbertee Ridge Cap Shingles Application Instructions:
(1) Step One — Separate each piece of GAF Timbertext Ridge Cap Shingles into three individual ridge
cap shingle pieces at perforations (see Figure 1).
Figure 1
(2) Step Two — Prepare the starter course... For this step, take a 12" x 12" (305mm x 305mm) ridge cap
piece and cut along the line between exposure and headlap (see Figure 2).
Starter' ^ ^_
Figure 2
Exposure S e
Self -Seal Adhesive on Back
ticker
Nail 9"(229 mm) from bottom
& i"(25 mm) from edge
YOA No.: 13-0306.08
Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 7 of 9
-ate 12" �I
12' �sl.e..--
IT �
(305mm)
(305mmj
(3051111WI
e
A
Adhesive
4'(102m; t
1 1
t t
on Back
__
Auto-
i 1
UlanAdhete
Sellante an la
9' (203n
Perforations t
Parte Posterior
i Perforacii
,fScellafAtrto-
8
1 Perforations
A
_m
A L' Endosnt
\
t I
Self -Seal Adhesive of Back
Bottom Backer
Adhesuo Arno-Sellante an la Parte Posterior
Apoyo Inferior
Adhasif Auto-Scellant A L'Endos
Aplwi Inferieur
(2) Step Two — Prepare the starter course... For this step, take a 12" x 12" (305mm x 305mm) ridge cap
piece and cut along the line between exposure and headlap (see Figure 2).
Starter' ^ ^_
Figure 2
Exposure S e
Self -Seal Adhesive on Back
ticker
Nail 9"(229 mm) from bottom
& i"(25 mm) from edge
YOA No.: 13-0306.08
Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 7 of 9
(3) Step Three — Place the 4" x 12" (102mm x 305mm) starter cap across the ridge starting at the bottom
of the hip or from the end of the ridge opposite the direction of the prevailing wind.
Note: For cold weather application or for high wind zones see special application section below.
(4) Step Four — Begin laying full ridge cap shingle pieces 12" x 12" (305mm x 305mm) as shown (see
Figure 2). Apply with an 8" exposure beginning at the bottom of the hip or from the end of the ridge
opposite the direction of the prevailing wind.
(5) Step Five — Apply ridge cap using 2 nails per piece 9" back from the exposed end and 1" up from the
edge (see Figure 3 for location of nails). Use only zinc coated steel or aluminum, 10-12 gauge, barbed,
deformed or smooth shank roofing nails with heads 3/8" (9.5mm) to 7/16' (12mm) in diameter. Nails
should be long enough to penetrate at least 3/4" (19mm) into wood decks or just through plywood decks.
Nails must be driven flush with the surface of the shingle. Over driving will damage the shingle. Raised
nails will interfere with the wind resistance of the shingles.
Figure 3
12" (305mm) --►I
} Top Laminated Piece
4, PiezaSuperiorLaminadt.
102mm Piece Lamin6e Sup6rieure
J 1rt1`(25mm) j 1 (25mmj •I
N&g t FDIi Line Nail
lean 1 Linea & Pliague Cla'vn
Clou Ligne N Pliage Clou
8`
203mm
Special Application Section:
For Cold Weather Application
• In cold weather, warm GAF Timbertexs Ridge Cap Shingles before bending.
• When self-sealing is delayed due to cold weather; apply quarter -sized dabs of asphalt plastic
cement (must confonn to ASTM D4586 Type I or Type fl) between ridge cap pieces and press
firmly to insure good contact between pieces.
• Note: Excessive application of tab adhesive can cause blistering of ridge cap shingle.
NOA No.: 13-0306.08
Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 8 of 9
For High -Wind Zones
g n high wind areas or for maximum wind resistance, apply a''/<" wide bead of Henkel PLe
Urethane Sealant or Sonnebomg NP -I TM Urethane Sealant to each ridge cap shingle 3/4"A" from
the shingle edge, parallel to the ridge (see Figure 4).
Figure 4
12" (305mm) --
xr-r Top Laminated Piece x" -r. —2,
4' pias Superio r Lantinade.
702rnm Pince Laminee Superieure
I�1LL'(25mmJ 1'(25rnmJ�
• T ' t
Nail 1 Fold Line + Nail
Claw 1 Linea de Plieque Clarn
Clou Ligne Da Pliage Clou
.4`
203mm
END OF THIS ACCEPTANCE
NOA No.: 13-0306.08
MAMPDADE COUNTY Expiration Date: 10/17/17
1 Approval Date: 08/15/13
Page 9 of 9
AMI-DADE
MIAMI• PRODUCT CONTROL L COUNTY
SECTION
ED 11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.¢ov/economv
GAF
1 Campus Drive
Parsippany, NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Pro-StartT°'Starter Strip and WeatherBlocker9m Premium Eave/Rake Starter Strip
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 13-1104.02 and consists of pages 1 through 5.
The submitted documentation was reviewed by Juan E. Collao, R.A.
MIAMH7ADE COUNTY
NOA No.: 14-1022.15
. • • •. , Expiration Date: 08/09/16
Approval Date: 02/05/15
Page 1 of 5
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub-Categorv:
Asphalt Shingles
Material:
Laminate
Deck Tvpe:
Wood
1. SCOPE
This approves GAF Pro -Start' Starter Strip and WeatherBlocker" Premium Eave/Rake Starter Strip
manufactured by GAF as described in Section 2 of this Notice of Acceptance, designed to comply with the High
Velocity Hurricane Zone of the Florida Building Code.
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
GAF Pro-StartT°' Starter 13" x 38"
Strip Shingles
Manufacturing
Locations #1, 2, and 3
GAF WeatherBlockerT 17" x 40"
Premium Eave/Rake
Starter Strip
Manufacturing
Location #2
2.1. MANUFACTURING LOCATIONS
TAS 110 Prefabricated starter strip asphalt shingle.
TAS 110 Prefabricated starter strip asphalt shingle.
1. Dallas, TX
2. Mt. Vernon, IN
3. Tuscaloosa, AL
2.2. EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Revort
PRI Asphalt Technologies, Inc.
ELK -34-02-01
TAS 100
Underwriters Laboratories, Inc.
OINK06632
ASTM D 3462
94NK9632
TAS 107
OONK32754
ASTM D 3462
09CA06856
ASTM D 3462
IOCA07264
ASTM D 3462
l ONK11953
ASTM D 3462
Date
05/16/00
02/01/01
03/29/00
08/11/00
05/15/09
05/27/10
10/29/10
NOA No.: 14-1022.15
Expiration Date: 08/09/16
Approval Date: 02/05/15
Page 2 of 5
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance. Refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
3.2 Shall not be installed on roof mean heights in excess of 33 ft.
3.3 All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61G20-3 of the Florida Administrative Code.
4. INSTALLATION
4.1 Starter Strip Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
4.2 The manufacturer shall provide clearly written application instructions.
5. LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade
County Product Control Seal as shown below.
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to
properly evaluate the installation of this system.
NOA No.: 14-1022.15
Expiration Date: 08/09/16
Approval Date: 02/05/15
Page 3 of 5
GAF PRO -.START— .STARTER STRIP SHINGLE
BACK VIEW
6"
61�°Typ I Each shingle preforated on (Las shown � I r 1 1/16°
TOP VIEW
MIAMFOADE COUNTY NOA No.: 14-1022.15
• • •. � Expiration Date: 08/09/16
Approval Date: 02/05/15
Page 4 of 5
38°
�
13"
-- _ --- _ _ ---
T5R
i
1
41111
BACK VIEW
6"
61�°Typ I Each shingle preforated on (Las shown � I r 1 1/16°
TOP VIEW
MIAMFOADE COUNTY NOA No.: 14-1022.15
• • •. � Expiration Date: 08/09/16
Approval Date: 02/05/15
Page 4 of 5
GAF WEATHERBLOCKEW- PREMIUM EAVE/RAKE STARTER STRIP
8.5'
Sett Seal
(216mm}
---------------------
17"
8.5'
\—Perforatlon
(432mm)
(216mm)
END OF THIS ACCEPTANCE
APPROVED
NOA No.: 14-1022.15
Expiration Date: 08/09/16
Approval Date: 02/05/15
Page 5 of 5