Loading...
HomeMy WebLinkAboutNOAMIAMI-DADE COUNTY MIAMFDADE PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline HV% Timberline Natural Shadow, and Timberline American Harvest® Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0419.04 and consists of pages 1 through 6. The submitted documentation was reviewed by Juan E. Collao, R.A. 606-11 MIAMINOA No.: 14-1022.20 B7 COUNTY • Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Cate¢orv: Roofing Sub-Cate¢orv: Asphalt Shingles Materials: Laminate Deck Tvve: Wood SCOPE This approves GAF Timberline HD®, Timberline Natural Shadow , and Timberline American Harvest® Shingles as manufactured by GAF as described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline HD® 13 '/4-x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt Manufacturing roof shingle, with a laminate profile Locations #1, 2, 3, 4, 5, 6, 7 GAF Timberline Natural 13 '/4"x 39 3/g' TAS 110 Fiberglass reinforced heavy weight asphalt Shadow roof shingle, with a laminate profile Manufacturing Locations #1, 2, 3, 4, 5, 6, 7 GAF Timberline American 13 '/4"x39'/8" TAS 110 Fiberglass reinforced heavy weight asphalt Harvest® roof shingle, with a laminate profile Manufacturing Locations #2, 4, 5, 6 MANUFACTURING LOCATION 1. Tampa, FL 2. Michigan City, IN 3. Baltimore, MD 4. Myerstown, PA 5. Ennis, TX 6. Tuscaloosa, AL 7. Dallas, TX NOA No.: 14-1022.20 Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 2 of 6 EVIDENCE SUBMITTED Test Agencv Test Identifier Test Name/Report Date Underwriters Laboratories, Inc. ASTM D3462 I ICA48924 10/24/11 Underwriters Laboratories, Inc ASTM D3462 I OCA21994 04/22/11 Underwriters Laboratories, Inc ASTM D3462 I OCA28717 07/26/11 Underwriters Laboratories, Inc. ASTM D3462 05CA47541 11/10/06 Underwriters Laboratories, Inc. ASTM D3462 06CA31580 11/30/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAF -101-02-02 11/02/05 Underwriters Laboratories, Inc. ASTM D3462 06NK05159 08/09/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAF -098-02-02 11/08/05 Underwriters Laboratories, Inc. ASTM D3462 02NK41809 08/11/02 Underwriters Laboratories, Inc. ASTM D3462 03NK26444 10/17/03 Center for Applied Engineering ASTM D3462 257989 05/13/97 Underwriters Laboratories, Inc. TAS 107 OINK45803 04/13/94 Underwriters Laboratories, Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories, Inc. TAS 107 04NK04273 02/20/04 Underwriters Laboratories, Inc. TAS 107 05CA42840 11/11/05 Underwriters Laboratories, Inc. TAS 107 02NK41811 11/11/02 Underwriters Laboratories, Inc. TAS 107 03CA35209 10/17/03 Underwriters Laboratories, Inc. TAS 107 04CA13850 08/30/04 Center for Applied Engineering TAS 100 257989 04/01/97 PRI Asphalt Technologies, Inc. TAS 100 GAF -044-02-01 01/13/04 PRI Asphalt Technologies, Inc. TAS 100 GAF -098-02-01 11/08/05 PRI Asphalt Technologies, Inc. TAS 100 GAF -101-02-01 11/09/05 PRI Asphalt Technologies, Inc. TAS 100 GAF -116-02-02 03/23/06 PRI Asphalt Technologies, Inc. TAS -100 ELK -083-02-01 10/16/02 ELK -084-02-01 10/15/02 ELK -085-02-01 10/14/02 ELK -086-02-01 10/24/02 ELK -087-02-01 10/21/02 ELK -088-02-01 10/16/02 ELK -107-02-01 10/09/03 ELK -108-02-01 10/09/03 ELK -109-02-01 10/09/03 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 14-1022.20 Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 3 of 6 INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail 'A', attached. 5. Nailing shall be in compliance with Detail 'B', attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 14-1022.20 Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 4 of 6 DETAIL A COURSE LAYOUT NOA No.: 14-1022.20 Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 5 of 6 DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN 39-3/811 (t m) 14-12" - 17-1/2" 14-1/2" - 17-1/2" (368-445mm) (368-"5mm) It 6-1/2"-9-1 /2" 6-1/2"-9-1/2" (156 Mimm) (185- m) Sia, )4 WG —�--�— • --49-- trr•-atrz° (a ENHANCED NAILING PATTERN - six nails per shingle' required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6" (152mm) from bottom of of shingle, above the cut outs, as shown. Nails must not be exposed. END OF THIS ACCEPTANCE Nail guide line 53/4" - 6-1/4" (146mm • 159mm) from bottom of shingle Self seal adhesive on back NOA No.: 14-1022.20 Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 6 of 6 M IAMF MICOUNTY 02MI CONTROL PRODUCT CONTROLL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Sheet, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Cobra Ridge Runner' Exhaust Vent for Roof Ridge LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA#13-0604.06 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera- l* r NOA No.: 14-1022.10 Expiration Date: 11/01/17 Approval Date: 01/29/15 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Ventilation Material: Plastic Minimum Slope: 3:12 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Product Dimensions Test Product Specification Description GAF Cobra® Ridge 20' Length (Roll) TAS 100 Low profile attic ridge vent in roll form for Runnefm Exhaust 11.5" Width installation under ridge shingles. Vent for Roof Ridge .7" Height MANUFACTURING LOCATION 1. Cumming, GA. EVIDENCE SUBMITTED Test Agency/Identifier Name Report Date ETC Laboratories, Inc. ASTM D 1929 ETC -07-718-19959.0 09/27/07 ASTM D635 ETC -07-718-19959.0 09/27/07 ASTM D 2843 ETC -07-718-19959.0 09/27/07 PRI Construction Materials Technologies, Inc. ASTM G 26 GAF -138-02-06 02/09/07 TAS 100(A) GAF -138-02-04 02/09/07 TAS 100(A) GAF -439-02-01 05/21/13 MIAMINOA No.: 14-1022.10 rm COUNTY 0=1 • , � � Expiration Date: 11/01/17 Approval Date: 01/29/15 Page 2 of 4 APPROVED APPLICATIONS Tradename: GAF Cobra Ridge RunnerTm Exhaust Vent for Roof Ridge System Type: Mechanical attachment of ridge vent. Slot: Determine whether the rafters are truss or ridgepole construction. Chalk a cut line of each side of ridge. Cut a 1 3/4" (no ridge board) or 3'/4" (ridge board) maximum slot along the apex of the roof by cutting 7/8" (no ridge board) or 1%" (ridge board) on each side of the ridge. The slot shall terminate 1 foot shorter at each end than the total length of ridge vent used. Installation: Place, center and conform the end of a piece of ridge vent at each end of slots. Mark the location of the end of the baffle. Strike a chalk line on both sides of the ridge to produce baffle alignment. Place vent sections centered over the slot using a chalk line. Place nails at pre -marked locations on the. Nails shall be minimum 11 guage 1-3/4" corrosion resistant smooth shank roofing nails, a minimum 3/16" penetration into wood substrate is required. Ridge Shingle: Using nail lines provided on top of vent. Nail cap shingles in place, as per ridge cap shingle manufacturer's installation instructions. Nails shall be minimum I1 gauge 1 3/4" corrosion resistant smooth shank roofing nails, a minimum 3/16" penetration into wood substrate is required. Ventilation Calculations: Refer to manufacturer's published literature LIMITATIONS: 1. Refer to applicable Building Code required ventilation. 2. Ridge Vent shall comply with applicable Building Code. 3. Ridge Vent shall not be installed on rof mean heights greater than 33 feet. NOA No.: 14-1022.10 Expiration Date: 11/01/17 Approval Date: 01/29/15 Page 3 of 4 DETAIL A 20' Length BOTTOM VIEW 1-11.5- Wide 7" [3E0ENNaX3X=EM -F END VIEW TOP VIEW END OF THIS ACCEPTANCE MAMFDADECOUMTY EQ. . 1t NOA No.: 14-1022.10 Expiration Date: 11/01/17 Approval Date: 01/29/15 Page 4 of 4 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Seal -A -Ridge® and GAF Timbertex® Ridge Cap Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 12-01011.14 and consists of pages I through 9. The submitted documentation was reviewed by Alex Tigers. NOA No.: 13-0306.08 t41AMMADE eouDnv Expiration Date: 10/17/17 11 IN • ' Approval Date: 08/15/13 Page i of 9 M�IAM11. MIAbII-DADE COUNTY CONTROL SECTION Em DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street. Room 208 11805 Miami. Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 rrww.mimnidadc zovlecononv NOTICE OF ACCEPTANCE (NOA) GAF 1361 Alps Road. Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Seal -A -Ridge® and GAF Timbertex® Ridge Cap Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 12-01011.14 and consists of pages I through 9. The submitted documentation was reviewed by Alex Tigers. NOA No.: 13-0306.08 t41AMMADE eouDnv Expiration Date: 10/17/17 11 IN • ' Approval Date: 08/15/13 Page i of 9 ROOFING ASSEMBLY APPROVAL CateQolm Roofing Sub-Cate¢orv: Asphalt Shingles Materials 3 -Tab Perforated Deck Type: Wood SCOPE This approves GAF Seal-A-Ridge9 and GAF Timbertex® Ridge Cap Shingles as manufactured by GAF as described in this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Seal -A -Ridge® Ridge Cap 12 x 36" TAS 110 Hip andhi o.clalong the 36" length perforatiRidgons Zasph It shingle Shingle of shingle. Manufacturing Location #1, 3 GAF Timbertex® Ridge Cap 12" x 12" TAS 110 fiberglass36 prof prefed abricatedhilt s and ridge ingle with Shingle perforations at 12" sections. Manufacturing Location #2 PRODUCTS MANUFACTURED BY OTHERS Product Product Size Manufacturer Description PL Polyurethane Roof & Flashing Sealant various Henkel PL Sealant NP -1T" Sealant various Sonneborn MANUFACTURING LOCATION 1. Tuscaloosa, AL. 2. Mt. Vernon, IN. 3. Mobile, AL. NOA No.: 13-0306.08 NLAMDADEcouNn Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 2 of 9 EVIDENCE SUBMITTED Test Aaency Test Identifier Tt Name/Report es Date PRI Asphalt Technologies, Inc. TAS 100 ELK-078-02-01 GAF-125-02-01 06/21/02 04/04/06 TAS 100 Underwriters Laboratories, Inc. ASTM D3462 IICA45079 06CA18074 03/21/12ASTM 06/16/06 D3462 ASTM D3462 12CA30879 02/01/13 TAS 107 I ICA45079 03/21/12 TAS 107 06CA18074 06/16/06 TAS 107 12CA38083 02/26/13 PRI Construction Materials Technologies LLC TAS 100 GAF-380-02-01 11/06/12 07/12/12 TAS 100 GAF-367-02-01 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. GAF Seal -A -Ridge® and GAF Timbertex® Ridge Cap Shingles shall be limited for use as hip and ridge cap shingles only. 3. Shall not be installed on roof mean heights in excess of 33 ft. 4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. INSTALLATION 1. GAF Seal -A -Ridge® and GAF Timbertex® Ridge Cap Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Nailing for GAF Seal -A -Ridge® Ridge Cap Shingles shall be in compliance with Detail 'A' attached. Exposure and course layout for GAF Seal -A -Ridge® Ridge Cap Shingles shall be in compliance with Detail 'A'. 5. Henkel PL Polyurethane Roof & Sealant or Sonnebom NP-lTM GunGrade must be used in the application of GAF Seal -A -Ridge® Ridge Cap Shingles as specified in Detail A and GAF TimbertexV Ridge Cap Shingles as specified in Detail B. 6. Nailing for GAF Timbertexg Ridge Cap Shingles shall be in compliance with Detail 'B' attached. Exposure and course layout for GAF Timbertex& Ridge Cap Shingles shall be in compliance with Detail 'B'. NOA No.: 13-0306.08 MIAMIDADE COUNTY Expiration Date: 10/17/17 Approval Date: 08115/13 Page 3 of 9 LABELING 1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County Product Control Approved". BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 13-0306.08 Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 4 of 9 DETAIL A GAF Seal -A -Ridge's Ridge Cap Shingles Application Instructions: (1) Step One — Separate each piece of GAF Seal -A -Ridge Ridge Cap Shingles into three individual ridge cap shingle pieces at perforations (see Figure 1). Figure 1 %i' (12 mm) !2 T 30:i nm:j G' Exposure r r (169mm) t r 12'�,— per'om'ed (305 mm) 36' (gid mm) (2) Step Two — Begin laying full ridge cap shingle with a 6-2/3" exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind (see Figure 2). Figure 2 astener NOA No.: 13-0306.08 MIAMFDADE COUNTY Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 5 of 9 (3) Step Three — Apply ridge cap using 2 nails per piece 6-5/8" to 7-5/8" back from the exposed end and 1" to 2" up from the edge (see Figure 2 for location of nails). Use only zinc coated steel or aluminum, 10- 12 gauge, barbed, deformed or smooth shank roofing nails with heads 3/8" (9.5mm) to 7/16" (12mm) in diameter. Nails should be long enough to penetrate at least 3/4" (19mm) into wood decks or just through plywood decks. Nails must be driven flush with the surface of the shingle. Over driving will damage the shingle. Raised nails will interfere with the wind resistance of the shingles. Special Application Section: For Cold Weather Application • In cold weather, wane GAF Seal -A -Ridge'° Ridge Cap Shingles before bending. • When self-sealing is delayed due to cold weather, apply quarter -sized dabs of asphalt plastic cement (must conform to ASTM D4586 Type I or Type II) between ridge cap pieces and press firmly to insure good contact between pieces. • Note: Excessive application of tab adhesive can cause blistering of ridge cap shingle. For High -Wind Zones In high wind areas or for maximum wind resistance, apply a two quarter -sized dabs of Henkel PL' Urethane Sealant to each ridge cap shingle approximatly 9" back from the exposed end and 1" from the shingle edge. (see Figure 3). Figure 3 9' (229 mm) 1" 11.M ) Sealant (292 mm1" �Sellante 5 mm) (25 mrn� Enduit d'6tancheild A I• Nail 12, Clavo (305 mm) Clouer 12" (305 mm) For maximum wind speed coverage under ltd. warranty, appy additional sealant as shown. See Special Application Section for specific detais. Para el akanee ffkWMo de veWdad de viento bajo limdado garantia, aplica sellador adciord como mostrado. Vea Secci6n .Especial deAplicaclen para detelles especlT�cos. Pour la couverture maxdmum de vitesse de vent sous Knit& la garantie, appliquer de 1'erduit d'6tanchdite supplementaire comme inclquC Voir h section speciale d'application pour les details sp®cifques. NOA No.: 13-0306.08 MIAMI-DADE COUNTY Expiration Date: 10/17/17 ' ' Approval Date: 08/15/13 Page 6 of 9 DETAIL B GAF Timbertee Ridge Cap Shingles Application Instructions: (1) Step One — Separate each piece of GAF Timbertext Ridge Cap Shingles into three individual ridge cap shingle pieces at perforations (see Figure 1). Figure 1 (2) Step Two — Prepare the starter course... For this step, take a 12" x 12" (305mm x 305mm) ridge cap piece and cut along the line between exposure and headlap (see Figure 2). Starter' ^ ^_ Figure 2 Exposure S e Self -Seal Adhesive on Back ticker Nail 9"(229 mm) from bottom & i"(25 mm) from edge YOA No.: 13-0306.08 Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 7 of 9 -ate 12" �I 12' �sl.e..-- IT � (305mm) (305mmj (3051111WI e A Adhesive 4'(102m; t 1 1 t t on Back __ Auto- i 1 UlanAdhete Sellante an la 9' (203n Perforations t Parte Posterior i Perforacii ,fScellafAtrto- 8 1 Perforations A _m A L' Endosnt \ t I Self -Seal Adhesive of Back Bottom Backer Adhesuo Arno-Sellante an la Parte Posterior Apoyo Inferior Adhasif Auto-Scellant A L'Endos Aplwi Inferieur (2) Step Two — Prepare the starter course... For this step, take a 12" x 12" (305mm x 305mm) ridge cap piece and cut along the line between exposure and headlap (see Figure 2). Starter' ^ ^_ Figure 2 Exposure S e Self -Seal Adhesive on Back ticker Nail 9"(229 mm) from bottom & i"(25 mm) from edge YOA No.: 13-0306.08 Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 7 of 9 (3) Step Three — Place the 4" x 12" (102mm x 305mm) starter cap across the ridge starting at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind. Note: For cold weather application or for high wind zones see special application section below. (4) Step Four — Begin laying full ridge cap shingle pieces 12" x 12" (305mm x 305mm) as shown (see Figure 2). Apply with an 8" exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind. (5) Step Five — Apply ridge cap using 2 nails per piece 9" back from the exposed end and 1" up from the edge (see Figure 3 for location of nails). Use only zinc coated steel or aluminum, 10-12 gauge, barbed, deformed or smooth shank roofing nails with heads 3/8" (9.5mm) to 7/16' (12mm) in diameter. Nails should be long enough to penetrate at least 3/4" (19mm) into wood decks or just through plywood decks. Nails must be driven flush with the surface of the shingle. Over driving will damage the shingle. Raised nails will interfere with the wind resistance of the shingles. Figure 3 12" (305mm) --►I } Top Laminated Piece 4, PiezaSuperiorLaminadt. 102mm Piece Lamin6e Sup6rieure J 1rt1`(25mm) j 1 (25mmj •I N&g t FDIi Line Nail lean 1 Linea & Pliague Cla'vn Clou Ligne N Pliage Clou 8` 203mm Special Application Section: For Cold Weather Application • In cold weather, warm GAF Timbertexs Ridge Cap Shingles before bending. • When self-sealing is delayed due to cold weather; apply quarter -sized dabs of asphalt plastic cement (must confonn to ASTM D4586 Type I or Type fl) between ridge cap pieces and press firmly to insure good contact between pieces. • Note: Excessive application of tab adhesive can cause blistering of ridge cap shingle. NOA No.: 13-0306.08 Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 8 of 9 For High -Wind Zones g n high wind areas or for maximum wind resistance, apply a''/<" wide bead of Henkel PLe Urethane Sealant or Sonnebomg NP -I TM Urethane Sealant to each ridge cap shingle 3/4"A" from the shingle edge, parallel to the ridge (see Figure 4). Figure 4 12" (305mm) -- xr-r Top Laminated Piece x" -r. —2, 4' pias Superio r Lantinade. 702rnm Pince Laminee Superieure I�1LL'(25mmJ 1'(25rnmJ� • T ' t Nail 1 Fold Line + Nail Claw 1 Linea de Plieque Clarn Clou Ligne Da Pliage Clou .4` 203mm END OF THIS ACCEPTANCE NOA No.: 13-0306.08 MAMPDADE COUNTY Expiration Date: 10/17/17 1 Approval Date: 08/15/13 Page 9 of 9 AMI-DADE MIAMI• PRODUCT CONTROL L COUNTY SECTION ED 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.¢ov/economv GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Pro-StartT°'Starter Strip and WeatherBlocker9m Premium Eave/Rake Starter Strip LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 13-1104.02 and consists of pages 1 through 5. The submitted documentation was reviewed by Juan E. Collao, R.A. MIAMH7ADE COUNTY NOA No.: 14-1022.15 . • • •. , Expiration Date: 08/09/16 Approval Date: 02/05/15 Page 1 of 5 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Categorv: Asphalt Shingles Material: Laminate Deck Tvpe: Wood 1. SCOPE This approves GAF Pro -Start' Starter Strip and WeatherBlocker" Premium Eave/Rake Starter Strip manufactured by GAF as described in Section 2 of this Notice of Acceptance, designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description GAF Pro-StartT°' Starter 13" x 38" Strip Shingles Manufacturing Locations #1, 2, and 3 GAF WeatherBlockerT 17" x 40" Premium Eave/Rake Starter Strip Manufacturing Location #2 2.1. MANUFACTURING LOCATIONS TAS 110 Prefabricated starter strip asphalt shingle. TAS 110 Prefabricated starter strip asphalt shingle. 1. Dallas, TX 2. Mt. Vernon, IN 3. Tuscaloosa, AL 2.2. EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Revort PRI Asphalt Technologies, Inc. ELK -34-02-01 TAS 100 Underwriters Laboratories, Inc. OINK06632 ASTM D 3462 94NK9632 TAS 107 OONK32754 ASTM D 3462 09CA06856 ASTM D 3462 IOCA07264 ASTM D 3462 l ONK11953 ASTM D 3462 Date 05/16/00 02/01/01 03/29/00 08/11/00 05/15/09 05/27/10 10/29/10 NOA No.: 14-1022.15 Expiration Date: 08/09/16 Approval Date: 02/05/15 Page 2 of 5 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3.2 Shall not be installed on roof mean heights in excess of 33 ft. 3.3 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Starter Strip Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 4.2 The manufacturer shall provide clearly written application instructions. 5. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 14-1022.15 Expiration Date: 08/09/16 Approval Date: 02/05/15 Page 3 of 5 GAF PRO -.START— .STARTER STRIP SHINGLE BACK VIEW 6" 61�°Typ I Each shingle preforated on (Las shown � I r 1 1/16° TOP VIEW MIAMFOADE COUNTY NOA No.: 14-1022.15 • • •. � Expiration Date: 08/09/16 Approval Date: 02/05/15 Page 4 of 5 38° � 13" -- _ --- _ _ --- T5R i 1 41111 BACK VIEW 6" 61�°Typ I Each shingle preforated on (Las shown � I r 1 1/16° TOP VIEW MIAMFOADE COUNTY NOA No.: 14-1022.15 • • •. � Expiration Date: 08/09/16 Approval Date: 02/05/15 Page 4 of 5 GAF WEATHERBLOCKEW- PREMIUM EAVE/RAKE STARTER STRIP 8.5' Sett Seal (216mm} --------------------- 17" 8.5' \—Perforatlon (432mm) (216mm) END OF THIS ACCEPTANCE APPROVED NOA No.: 14-1022.15 Expiration Date: 08/09/16 Approval Date: 02/05/15 Page 5 of 5