Loading...
HomeMy WebLinkAboutEngineering FLO A ENGINEERING & TESTING, INC. Phone: (866)781-6889•Fax: (866)'784-8550 www.floridaengineeringandtesting.com 250 S.W.13"'Avenue 'J. Pompano Beach,FL 33069 DATE: 3/11/16 JOB ORDER#: 16-842 CLIENT: All Area Roofing ADDRESS: 3921 S. US Highway 1 Fort Pierce,Florida 34982 PROJECT: Attanasio Residence 5-V Crimp Roof Panel i ADDRESS: 449 Nettles Blvd. Jensen Beach,Florida ' I r i FBC 2014/ASCE 7-10 DESIGN PRESSURE CALCiTLATIONS Project Information: C Mean Height= 15' Exposure: D Basic/Ultimate Wind Speed: Vuit=170 mph Length= 50' Category: II Nominal Wind Speed: Vasa=Vwt*�0.6 Width= 40' Slope: 3/12 = 14° (asd=allowable strength design) Parapet Wall: N/A Residential KZ= 1.03,Kzt= 1'10, Kd= 0.85 it i Design Calculations: Velocity Pressure: q= 0.00256*KZKZtKdV2 I Velocity Pressure („lt): q=0.00256(1.03)(1.0)(0.85)(170)2] =641177 psf;a Velocity Pressure (asd): q=0.00256(1.03)(1.0)(0.85)(170*�0.6)2i] = 38.8',6 psf I �.j Width of Pressure Coefficient: 0.1(40') = 4.0' I I, 0.4(15') = 6.0' } use: 410" Effective Wind Area: <102 External Pressure Coefficient: Internal Pressure Coefficient: I 1) GCP1 = -0.9 1) GCP; = 0.18 2) GCP2 = -1.7 3) GCP3 = -2.6 j Design Pressures Based on Vasd: II i 1) Field - P1 = 3 8.86*[(-0.9)—(0.18)] =-42.0 psf 2) Perimeter P2 = 38.86*[(-1.7)—(0.18)] =-73.1 psf 3) Corners P3 = 3 8.86*[(-2.6)—(0.18)] = 1081.0 psf ' I QraalitrJ ��3 &.flssrcranee ii i,. i Page 2,3/11/16,Job Order#16-842 All Area Roofing FLO A Attanasio Residence-5-V Crimp Roof Panel 449 Nettles Blvd.;Jensen Beach,Florida: f Attachment Requirements: I Based on the requirements of Florida Product Approval # 17022.1R3, Table A, Method 2 with maximum design pressures of -93.5psf; the following are ;our recommended fastening patterns to attach the 26 ga. 5-V Crimp roof panel to"the minimum 15/32" thick plywood or wood plank decking utilizing # 10 x 1-1/2" minimum Hex Washer Head Wood screws to provide a minimum 3/16" fastener penetration thru bottom of support in the following fastener patterns and these fastener row spacings: i Method 2 (Field & Perimeter) I Method 4 (Corners) _ - Design Pressure -93.5 psf ! -228psf ASD Row Spacing 16" o.c. 6" o.c. 12" O.C. 12" o.c. Fastener Spacing (Attached to the tops of the V's (Attached to the tops of the V's (Across Panel for a total of 3 screws across the for a total of 3 screws across the Width) 24" width of thepanel) 124" width of thepanel) Notes: Corners and perimeter (edge, hip, & ridge) area dimension shall not be less than a = 4'0" (Zone 2: Perimeter (including along ridges) is a 4'0" wide strip, Zone 3: Corners are 4'0" x 41011) Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty(as applicable).; All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2014 Edition. Wind load calculations based on ASCE 7-10, FBC 2014 and information provided by client. Client is responsible for verifyingi existing conditions as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely; i i Mark A. M.-siano,P.E. Florida Engineering&Testing, Inc. Florida Reg. No:48202 Certificate of Autrorization No. 6923