HomeMy WebLinkAboutEngineering PA UL�i'`i��ii CHi& it,1C. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone(772) 785 - 9888 Email pwelchinc@aol.com March 23, 2016 Re: Nyhlen Shutter Installation 7002 Torrey Pines Cir. Port St. Lucie, FL 34986 To Whom It May Concern: Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2014 for the installation of accordion shutters at the above referenced address. Wind speed: V„tt: 160 mph,V.d: 124 mph Exposure: C Enclosure Type: Enclosed Shutter Size: 100"Maximum Height Shutter Location: See Attached Sketch Required Design Pressure: +23.3 /-31.1 PSF Shutters to be installed shall be equal to, or exceed the required design pressures as listed above"Required Design Pressure". Accordion Shutters shall be installed in accordance N-ith the shutter manufacturer's installation instructions and Florida Product Approval and Florida Building Code 2014. Accor*48hutters shall be FL# 389.1. ou=for your attention to this matter. ubmtted `C3 ?/ �g No 299