HomeMy WebLinkAboutProduct Approval Page 1 of 2
5PST
r
flog is �";s'
)antu BCIS Home Log In ; User Registration Hot Topics i Submit Surcharge i Stats&Facts Publications ; FBC Staff i SCIS Site Map Links j SearchBusiNn�'a
ProfessrlQ7-'� Product Approval
1USER:Public User
_•.
Regulation
_I Product Approval Menu>Product or Anpticetion Search>APrAcation List>Application Detail }?z+it �E
'�$a +-�=i1b -{ FL k FL16048-R3
Application Type Revision ��� ��
Code Version 2014
Application Status Approved
PERMITTING
St. Lucie County, FL
Comments
Archived
Product Manufacturer TRI-BUILT Roofing Products
Address/Phone/Email 9050 Louisiana Street
Merrillville,IN 46410
(201)842-2449
david.ruiz@tribuiltmateriaisgroup.com
Authorized Signature David Ruiz
david.ru iz@tri b u i itmaterialsg rou p,com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford,NJ 07073
(201)842-2449
davld•ruiz@tribuiltmateriaisgroup.com,
Quality Assurance Representative
Address/Phone/Emali
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nleminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL16048 R3 COI 2015 01 COI Nieminen_pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM GI55 2005
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWr._. 1/95/?nt r,
~ TRINITY|^-^^~-
7. 0VummG PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in under to properly evaluate the installation of
this product.
Q, MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C.Rule 9N-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
ULLLC—QUA9G2S;(3l4)S7O-3406;k.chmnreUor@>uu.u|.com
-END#pEVALUATION REPORT'
Werior Research and DesIZn,uc Evaluation Report A42960.1D.12-113
Certificate of Authorization#9503 F1.16048-113
Revision o'zn/08/on15
Page sms
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization#9503
TRINITYQOERD 353 CHRISTIAN STREET,UNIT 8
; OXFORD,CT 0647478
PHONE: (203)262-9245
FAX:(203)262-9243
EVALUATION'REPORT
Allied Building Products Corp. Evaluation Report A42960.10.12-R3'
dba TRI-BUILT Roofing Products FL16048-R3
9050 Louisiana Street Date of Issuance:10/25/2012
Merrillville, IN 46410 Revision 3: 10/08/2915-
SCOPE:
0/08/2015SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume, The
products described herein have been evaluated for compliance with the 5th Edition (-2014) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall ibe done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or,
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by:
The facsimile seal appearing was authorized b Robert Nieminen,
Robert J.M.Nieminen,P.E. ; :,, ,�`a�e;.;•.,, Pp g v_
,,r,rs.st P.E.on 10/08/2015.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 document.signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. .Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have;nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity]ERD nor Robert Nieminen, P.E. are; in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
1
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where
the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck
underlayment systems that are.not addressed in FRSA/TRI April 2012 (04-12)and are used in foam-on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6.4.1 Maximum Design Pressure=-45.0 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)ASTM D41
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
5.7 Exposure Limitations:
5.7.1 Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
5.7.2 Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation.
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile applications:
While priming is optional, TRI-BUILT recommends priming the deck if the final roof cover is not slated for
installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps
shall be sealed using either heat-welding or hot air welding techniques.
When installing at slopes above 8:12, Allied Building Products Corp recommends back-nailing in the
overlap area at the top of the sheet at 12-inch o.c. _
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Tri-Built S/A HT TU Underlayment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R3
Certfcate of Authorization#9503 171-16048-113
Revision 3:10/08/2015
Page 4 of 5
'
'` / ����
�a U ��U»wo N U !^-"~��
ROOFING COMPONENT EVALUATION:
1. Scmps:
Product Category: Roofing
Sub-Category: Undedoyment
Compliance Statement: TRI-BUILT Roof Underlayments,as produced by TRI-BUILT, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordancewith the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.3.4,1507.2.8,1507.2.9.2, Physical Properties ASTM D1970 2009
1507.4.5.1,1507.5.3,1507.7.3
1504.6 Accelerated Weathering ASTM G155 2005
15073.3 Installation Practice FnSA/TR|April 2O12(0412) 2012
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
Entity Examination Reference Date
s8u(TST6049) Physical Properties s40540.02.13-1 02/19/2013
sKoyBT6049> Physical Properties s40640.11.13 11/18/2013
sRu(TST6049) Physical Properties 340540.03,14 03/26/2014
cRD(TST6U49) Physical Properties S44870u4.14`3 04/02/2014
cKo(TSJ6O49) Physical Properties S44870.04.14-3 04/02/2014
sRo(T376D49) Physical Properties S44878.04.14-1 04/10/2014
ERm(TST6849) Physical Properties s44870.84.144 04y10/2014
ERD(T86049) Physical Properties 543530.02.14-1'81 05/14/2014
ERD(TST6U49) Physical Properties S43530.05.14 05/28/2014
tRo(TSTGO4S) Physical Properties s40540.10.14 10/31/2014
[RD03TG049> Physical Properties sC7�45.02.15 02/13/2015
sRD(TsT6V49) Accelerated Weathering sC0520.04.15 05/27u01G
UL,LLC.(QUxgoz5) Quality Control Multiple-Listing n16D14 09/04/2015
UL,LLL(QUA96z5) Quality Control Service Confirmation Exp.10/16/2017
4. PRODUCT DESCRIPTION:
4.1
4.1.1 Tri-BuiltSand-R SA Shingle Umderlaymentis o self-adhering, g(asomatre|nfurued sond*udace6 SBS
modified bitumen roof undedayment,with a36-inohsheet width.
4.1.2 Tri-Built 5/A HT TU Undedoyment is o self-adhering, non-woven polyester fabric surfaced, SBS modified
bitumen roof undedayment
4.1.8 Tri-Built Smooth HT S/A Underlayment is a self-adhering,glass-mat reinforced,film-surfaced,SBS modified
bitumen roof undedayment.
S. L|xxnAT|oms:
5.1 This is a building code eve|uabon. NeitherThnkyJERD nor Robert Nkeminen, P.E. are, in any way, the
Designer ofRecord for any project on which this Evaluation Report, orprevious versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report isnot for use inthe HVHZ.
5.3 Five Classification is not part of this Evaluation Report; refer to current Approved Roofing K8otehab
Directory for fire ratings ofthis product.
Exterior Research and Design,uc Evaluation Report A42960.10.12-R3
Certificate of Authorization xss ruommm
Revision 3:10/08/2015
Page 2'xs
� `
;..`
^ '
EXTERIOR RESEARCH&DESIGN,I.I.C.
^
Certificate of Authorization#9503
J/ �RD 3S3'CHR|STiANSTREE�UNIT#1B�Y| OXFORD,CTO6478TRIN8
PHONE:(2U3)2GZ'9245
FAX:(203)2G2-9243
EVALUATION REPORT
Allied Building Products Corp. Evaluation Report A42960.10.12-113
6baTRI-BUILT Roofing Products FL16048'113
9USOLouisiana Street Date ofIssuance:1O/2S/2012
Merrillville, |N4641D Revision 3: 10/08/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20'3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the G,h Edhioh (2014) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlaynments '
LuosumG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. ifthe- product
changes orthe referenced Quality Assurance documentation changes. Tdnity(ERDrequires acomplete review ofthis'
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TYin|tylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, ocopy ofthis entire Evaluation Report shall beprovided tothe user bythe manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists ofpages 1through S.
Prepared by:
'
�
rm��°w seal appearing was authorized by Robert Nienninen,
Robe�1M,N�nnen,P�. �eP.E.c z�u
nva_m*��"m�"�=
electronically signed
FbddoRegbtnabonNo.�D6� Ro�doDC4ANE1983
document.Signed,sealed h"mcop/=have been transmitted mthe
Product Approval Administrator and mthe named client
CERTIFICATION oFINDEPENDENCE:
I. Thnity\ERo does not have, nor does itintend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products itevaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This i, abuilding code evaluation. Neither Trinity I ERD nor Robert Nlemlnen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY I ERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within.FBC approval documents. If not listed, a request may be made to the AHJ for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5:5 Allowable roof covers applied atop the underlayments are as follows:
TABLE-1: ROOF COVER OPTIONS
Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes Slate
&Shingles
Tri-Built Sand-R SA Shingle Yes No No No Yes Yes
Underlayment
Tri-Built S/A HT TU Yes
Underlayment Yes Yes See 5.5.1 Yes Yes Yes
Tri-Built Smooth HT S/A Yes No No Yes Yes Yes
Underlayrrient
5.5.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives unless.tensile adhesion /long
term aging data from an accredited testing laboratory is provided.
➢ Tri-Built S/A HT TU Underlayment with 3MTm 2-Component Roof Tile Adhesive AH-160(FL6332)or Dow
TileBondTm Roof Tile Adhesive(FL717)
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
Plywood; ASTM D41 primed plywood; OSB; ASTM :D41 primed OSB; ASTM D41 primed structural
concrete.
While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT recommends priming
the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT requires
tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-
adhering underlayment.
5.6.2. Bond-to-Insulation:
Tri-Built S/A HT TU Underlayment applied to:
➢ Dens Deck Prime;SECU ROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems,insulation attachment shall be designed by a qualified design professional and
installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D
or TAS 114,Appendix J.
5.6.3 Bond to Mechanically Attached Base Laver:
➢ ASTM D226,Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems,base layer shall be attached
per minimum requirements of FRSA/TRI April 2012(04-12).
Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-113
Certificate of Authorization#9503 F1.16048-113
Revision 3:10/08/2015
Page 3 of 5
TRINITY l ERD
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C..Rule 9N-3 QA requirements.
9. QUALITY.ASSURANCE ENTITY:
UL,LLC-QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,L.I.C. Evaluation Report A42960.10.12-113
Certificate of Authorization#9503 F1.16048-113
Revision 3:10/08/2015
Page 5 of 5
Florida Building Code Online Page 1 of 2
Florida Departmentof BCIS Home I Log In I user Registration I Hot Topics I Submit Surcharge Stats&Facts I Publications I FBC Staff I BCIs Site Map I Links I Search
Business
Professi al �. 1Y PIr
USER:
dublicUser
ctApproval
Regulation
Product Approval Menu>Product or ADD11cation Search>Application List>Application Detail
• . FL# FL16048-R3
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer TRI-BUILT Roofing Products
Address/Phone/Email 9050 Louisiana Street
Merrillville,IN 46410
(201)842-2449
david.ruiz@tribuiltmaterialsgroup.com
Authorized Signature David Ruiz
david.rulz@tribuiltmaterialsgr6up.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford,NJ 07073
(201)842-2449
david.ruiz@tribuiltmaterjalsgroup.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
i
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W.Knezevich,PE
W' Validation Checklist-Hardcopy Received
Certificate of Independence FL16048 R3 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM G155 2005
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtFPmdYiND Wr... 3/25/2016
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 10/08/2015
Date Validated 10/19/2015
Date Pending FBC Approval 10/21/2015
Date Approved 12/15/2015
Summary of Products '
FL# Model,Number or Name Description
16048.1 - TRI-BUILT Roof Underla ments Self-adhering,modified bitumen roof underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16048 R3 II 2015 10 FINAL ER TRI-
Approved for use outside HVHZ:Yes BUILT UNDERLAYMENTS FL16048-R3.odf
Impact Resistant:N/A Verified By:Robert Nieminen PE-59166
Design Pressure:+N/A/-45 Created by Independent Third Party:Yes
Other:1.)The design pressure noted herein pertains to use of foam-on Evaluation Reports
tile systems overtop the self-adhering underlayment for one particular FL16048 R3 AE 2015 10 FINAL ER TRI-
application.See ER Section 5.6 for details.2.)Refer to ER Section 5 for BUILT UNDERLAYMENTS FL16048-R3.Odf
other Limits of Use. Created by Independent Third Party:Yes
NOW
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone;850-487-1824
• The State of Florida Is an AA/EEO employer.Coovrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement;:;Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The
emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
® EChecA M
securih'�u-rlltts
14
a
http://www.floridabuilding.org/pr/prapp_dtl.aspx?param=wGEVXQwtDqtFPmdYiNDWr... 3/25/2016