Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL Florida Building Code Online Page 1 of 2 r� Florida Nepaltmento BCIS Home I Login I User Registration,I Hot'ropl6 I Submit Surcharge Stats&Facts I Publications i FBC!Staff'I BCIS Site Map I•Links Search Busines f t::l Professib Product Approval -'al ( USER:Public User Regulation Product Approval Menu>Product or Application Search>Apolication List>Application Detail 'I e FL# FL10124-R17 Application Type Revision Code Version 2014 Application Status Approved I Comments Archived ❑ Product Manufacturer GAF Address/Phone/Email 1 Campus Drive j Parisppany,N)07054 (973)872-4421 lindareith@trinityerd.com Authorized Signature Beth McSorley lindareith@trinityerd.com Technical Representative Beth McSorley(current) Address/Phone/Email 1 Campus Drive Parsippany,NJ 07054 (973)872-4421 bmcsorley@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles I Compliance Method Evaluation Report from a Flod6 Registered Architect or a Licensed Florida Professional Engineer , ❑ Evaluation Report-Hardcopy Received i Florida Engineer or Architect Name who developed the Robert Nieminen 'f Evaluation Report Florida License PE-59166 I Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/14/2016 Validated By John W.Knezevich,PE • 6 Validation Checklist-Hardcopy Received i Certificate of Independence FL10124 R17 COI 2015 01 COI Nieminen odf Referenced Standard and Year(of Standard) Standard I year ASTM D1970 2009 ASTM D3161 i 2009 ASTM D3462 2009 ASTM D7158 2008 TAS 107 1995 Equivalence of Product Standards Certified By Sections from the Code I http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQIwtDqurl'acBeV CbdM... 3/15/2016 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 12/16/2015 Date Validated 12/16/2015 Date Pending FBC Approval 12/19/2015 Date Approved 02/10/2016 Summary of Products FL# Model,Number or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,laminated,5-tab and hip/ridge asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL10124 R17 II 2015 12 FINAL ER GAF Asphalt Shingles FL10124- Approved for use outside HVHZ:Yes R17.odf Impact Resistant:N/A Verified By:Robert Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER,Section S. Evaluation Reports FL10124 R17 AE 2015 12 FINAL ER GAF Asphalt Shingles FL10124- R17.pdf Created by Independent Third Party:Yes Fmw Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Conyriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee,However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: W] ® eCAetk M sectiritw.writics http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeV CbdM... 3/15/2016 i 'I I EXTERIOR RESEARCH 11 DESIGN, LLC. Certificate of Authorization#9503 TRINITY ERD "353 CHRISTIAN STREET,UNIT#13 QOI OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT GAF Evaluation Report 01506:61:08-1119 1 Campus Drive ;i FL10124-1117 Parsippany,NJ 07054 Date of Issuance:01/03/2008 Revision 19:12/15/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th.Edition '(2014) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles ,j LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report.is valid until such time as the nani ed products)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in ,advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the`user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building,Official. This Evaluation Report consists of pages 1 through 6. Prepared by: :,�•�s�:"�e10T;gip' � Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert Nieminen, 4j, a��i+t` kE.an 12/15/265.This does not serve as an electronically signed Florida Registration No.59156,Florida DCA ANE1983 'document:Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest,in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or dis Iributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any otherlentity involved in the approval process of the product. �' 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. � I,I II ii a I �I TRINITY I ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: I Product Category: Roofing j Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: 11 Section Prope Standard i' Year 1507.2.4;R905.2.3 Physical Properties ASTM D1970 j 2009 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R965.2.6.1 Wind Resistance ASTM D7158 2008 1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995 r 3. REFERENCES: Entitv Examination Reference li Date GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant,IR 01/13/2012 PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 i 05/25/2005 PRI(TST 5878) Physical Properties -GAF-324-02-01 12/01/2011 PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 I 01/12/2000 UL(TST 1740) TAS 107 94NK9682 03/29/2000 UL(TST 1740) ASTM D3462 01NK06632 02/02/2001 UL(TST 1740) ASTM D3161,TAS 107 OSNK9226 05/21/2001 UL(TST 1740) ASTM D3161 OINK37122 12/18/2001 UL(TST 1740) ASTM D3462 O1NK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 ;I 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 I. 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 05NK27924 02/10/2006 UL(TST 1740) ASTM D3161 OSNK27924 'I 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 UL(TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008 UL(TST 1740) ASTM D3161,D3462 07CA55908 ;; 04/01/2008 J , Exterior Research and Design,U.C. Evaluation Report OiS06.01.08-R19 Certificate of Authorization#9503 FL10124-R17 Revision 19:12/15/2015 Page 2 of 6 I .I i ij j TRINITY I ERD Kn2bf Examination Reference Date UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM D9161,D7158,D3462 09NK06647 08/01/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/05/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15%2010 UL(TST 1740) ASTM D3462 IOCA07264 it 05/27/2010 UL(TST 1740) ASTM D3462 10CA.11953 10/29/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK12070 11/04/2010 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL(TST:1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011 UL(TST 1740) ASTM D3161,D7158,D3462 IICA48408 12/08/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 I, 12/09/2011 UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012. UL,LLC.(TST 9628) ASTM D3161,D71S8,D3462 12CA58151 02/15/2013 UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013 UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013 UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report,1121,Mobile,AL 06/19/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report,1 R21,Myerstown,PA 07/21/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 06/26/2015 UL,LLC.(QUA 9625) Quality Control Inspection Reportj R21,Michigan Cty,IN 05/14/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report).R21,Shaf>:er,CA 07/16/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report R21,Savannah,GA 06/24/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report1;R21,Minneapolis;MN 07/14/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report-1321,Mt.,Vernon,IN 07/10/2015 UL,LLC:(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 07/21/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report R21,Tampa,FL 06/26/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report.R21,Dallas,TX 07/15/2015 UL,LLC.(QUA 9625) Quality Control Inspection Reporti R21,Ennis,TX 07/09/2015 UL,LLC.(QUA 9625) Quality Control Inspection ReportR21,Fontana,CA 07/16/2015 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof shingles. 4.1.2 Camelot®,Camelot®II,Country Mansion®II,Glenwood1m,Grand Canyon®,Grand Sequoia®,Grand Sequoia® IR, Monaco®, Sienna®, Timberline American Harvest®, Timberline- ArmotShielclTm II, Timberline® Natural Shadow®, Timberline HD®, Timberline® Cool Series, Timberline Ultra HD®;and Woodland® are fiberglass reinforced,laminated asphalt roof shingles. 4.1.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle. 4.2 Hip&Ridge Shingles: 4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Impact-Resistant Ridge Cap Shingles and Timbertex® Premium Ridge Cap Shingles are fiberglass reinforced,hip and ridge asphalt:'roof shingles. 4.3 Starter Strips: 4.3.1 Pro-Start® Starter Strip Shingles and WeatherBlockerTM Premium Eave/Rake Starter Strip are starter strips for asphalt roof shingles. Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R39 Certificate of Authorization 119503 FL10124-R17 Revision 19:12/15/2015 Page 3 of 6 • I� Q 0 TRINITY I ERD 4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS modified bitumen starter strip,nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of&inch or less. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robe rt Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current;Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: " 5.4.1 The.GAF asphalt shingles noted in Section 4.1 are Classified in accordance 'with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, iii dicating;the shingles are acceptable for use in all wind zones up to Vasd=150 mph(V„it=194 mph). Refer to Section16 for installation requirements to meet this wind rating. 5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable,for use in all wind zones up to I . Vasd=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C.'and a building height of 60 feet or Less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. i 5.5 All products in the.roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Starter Shingles or Starter Strip: 6.2.1 Installation of Pro-Start Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Camelot,Camelot.11,Grand Canyon,Grand Sequoia,Grand Sequoia IR,jand Woodland require minimum five(5)nails per shingle. ➢ Slateline requires minimum six(6)nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. ,I. I I Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1119 Certificate of Authorization#9503 FL10124-1117 Revision 19:12/15/2015 Page 4 of 6 li I QOTRINI-rYIERD 6.4 Hip&Ridge Shingles: 6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles and Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles shall comply with the manufacturer's current published instructions with a minimum two (2)nails, minimum 3/8- inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel "Loctite PL S30 Roof & Flashing Sealant". 11.51 Sealant —17--(292 mm) 1 Sellante I (25 mm) (25 mm) Enduit d'dtanchdM f' i (305 mm) Nail Clavo 6 5/&-7 5/8, Clouer (168-.194:mm) I 12' i (3 05 mm) 6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall cl mply with the manufacturer's current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NPI Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. 1'4� 5eatattl I, 1 1292 mini t� Sollnnty (25 tntm) e,25 mat EnSluit0dGittd-t,Eipii I A-- NOR__._.NOR � t�• Grauer (305 wrn) tips rnmy i'I 'I it (305 nt;n) 6.4.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. i J I Exterior Research and Design,LLC. Evaluation Report 01506.01.08-RI9 Certificate ojAuthorization#9503 FL10124-1117 Revision 19:12/15/2015 Page 5 of 6 'I i i I TRINITY I ERD 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accridited Quality Assurance Agency noted herein. I 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction.in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: j I UL LLC—QUA9625;(847)664-3281 END OF EVALUATION REPORT- �I I I � 1 'i I � I Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R19 Certificate of Authorization 119503 I FL10124-1117 Revision 19:12/15/2015 Page 6 of 6 CUST PO#j mager cost ALLIED BUILDING PRODUCTS TICKET# 13063745-00 SO PLACED BY 701 S MARKET AVE FORT PIERCE,FL 34962 SHIP WHSE FPIE PAGE# 1 of 1 TAKEN BY LORT SALES REP 4505 — " Phone:(772)466-3461 1 Fax:(772)466-4542 DOCUMENT Order Acknowledgement ORDERED 3/28/2016 1 PROMISED 3/30/2016 ` ® SHIP VIA Our Truck INSTRUCTIONS an ord=de'r pang PRINTED CUSTWHSEJ FPIE I STAGING CUSTOMER GENERIC CASH RFG-FPIE SHIPTO mager const (183175) 701 S MARKET AVE 750 NETTLES BLVD ORDER ACKNOWLEDGEMENT NETTLES ISALND 772-595-8290 '**DO NOT SHIP FROM THIS DOCUMENT*** FORT PIERCE, FL 34982 FORT PIERCE, FL 34949 CANCELATION DATE: NONE Line Product and Qty Qty Oty Oty Unit Price Amount Description Ordered B.O. Shipped UOM Price UOM Net 1 : 82220175 _RL _ __ __26.00 . ____ - _ RL 234.00 TRI-BUILT T 30LB FELT UL ASTM D226 TYPE 1 2SQ 2 33700920 _ _ __. 1-- _0 1- -_CTN__.__ _ 47.75 _ CTN_- 47.75 METRO DADE TIN CAPS 50 LB=C N i 3 ;89320393 - -.- -- _ ------ -__ _- -_--__----- --._____._._ __ 10 -1 ,---EA ".27.60_ .. -_EA___. __27..60 COIL NAILS METRO DADE RINGSHANK 1-1/41N UNIT OF MEASURE"EA"=CARTONS 4 188902292 -- -- - -------- . - _ T .__.-_�- ---- _-_--_ _ 22 - _ . _ __0_ I- __22-1--_-- PC _ --_ - -- __ __4.75,_ -PC ___ 1.04.50_ DRIP EDGE GALV 2X2 1 OFT WHITE 26GA 10 LFT= C 29.00_ TRI-BUILT G-FL A/F WET DRY PLAS RF CMT 5GL SUM NON-BULK NOT REGULATED(Combustible liquid Non-Bulk) NOT SHIP BY AIR OR WATER*********** 6 . 34820960 - - - - - - - - - -- - -- - -- - - -- -2-7: -Q " - _ __2-' -PC------ 11_.45 --- — -PC- _ --_22.90 LEAD PIPE FLNGE 21N --__7--.3.4_.820990 __. 1_ _ _. _ _0- : -- -- -_ 1_-_ _PC -- PC _.. 16.40 LEAD PIPE FLNGE 31N -- --- - — - — - - -- OrderSubtotal - _ . - —= _-__ _.-$482.15 - -- Fuel Charge $50.00 Order Tax $31.37 Order Total $563.52 Ch k#1700: 563.52 Available to Ship Total $563.52 Down Payment $563.52 Balance Due Not Write Below This III 11111111111111111111Order Acknowledgement 13063745-00 1 OF 1 FPIE SO