Loading...
HomeMy WebLinkAboutEngineering • RSC IY70 MAR 29 2016 FILE COPY DATTT t7TI]ELI.! IT_INC rcrvs� �rLi�:■.■ il�t.. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772)785 - 9888 Email pwelchinc@aol.com March 28,2016 Re: Reese Re-Roof 5000 Avienda Ave. Fort Pierce,FL 34946 SCOP OF WO-RI-K: Remove existing roofing and install new Standing Seam Metal Roof(Metal Sales Manufacturing Corporation FL# 11560:4)at above referenced residence address over new underlayment and existing plywood sheathing. (Flat Roof Not Included) DESIGN CRITERIA: FBC 2014 ASCE?-iv PROJECT DATA: BUILDING HIEGHT= 8'-0" A=3' MEAN ROOF HIEGHT=<15' ROOF ANGLE=4:12 SHAPE=PITCHED HIP/GABLE HAPROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 160 MPH WIND VELOCITY V asd= 124 MPH EXPOSURE=C ENCLOSURE CLASS=ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF 0st): ZONE 1 (Field)=-31.9 ZONE 2(Perimeter/Ridge)_-53.9 ZONE 3 (Corners)_-79.2 1 � •� o-'ro- •�0F a r Panl-Welch T.n- � :.. `t Paul Welch P.E.Reg.No. 29945 1Vlarch 28,2016 1 of 3 5000 Avienda Av.Fort Pierce,FL r ROOFING fTA CUM RF01_ Fn lv rc• Metal roofing to be attached with#10- 12 x 1 Y2"long(minimum 1/4"penetration through plywood sheathing)pancake head screws along the panel seam. ALL ZONES : Screws spaced at 24" on center along the seam of the panel. Product Design LTpli-ft Pressure-: -84?5psf 79.2 < 84.25 Therefore O.K. MERLAYMENT: Underlayment shall minimum ASTM D226 Type II installed with a minimum 4"side-lap and 6" end-laps. Underlayment shall be fastened with corrosion resistant tin-caps and 12Ga 1 Ila" annular ring-shank nailsS»ace 66"(D.C. at ll laps and two staggered rmvs at 12"O C i ts� field of the roll or any approved underlayment having a current NOA.an approved underlayment and installed per roof manufacturer's guidelines in compliance with FBC 1507.4.5. DECK INSTALLATION: Re-nail all plywood sheathing(15132"thick minimum)with 8D ring-shank nails at 4"O.C. narimetar awnyri "O.C. eld Lor all Zones r._.... ... . All work to be in compliance with product approval (FL# 11560.4),manufacturer's specifications, and the Florida Building Code 2014. P-11 Wel Yh Th;e. Paul Welch P.E.Reg.No. 29945 March 28,2016 5000 Avienda Av,Fort Pie.me,FT, 2 of 3 a r ` " VSAT tZbaF — � N oT ZI+�WGE17 1 I A 1 / em r lit ;t (T(r) T , L 7?l1f1F 7nwr 'PT.A1V t\V Vi LJVl\aL1iJL 11\ A=3' 1D ,03 =ZONE DESIGNATION(TYPICAL) NOTE:ALL ZONES REQUIRE SAME ATTACHMENTS. PamWelch TLnc. Paul Welch P.E. Reg.No. 29945 March 28,2016 3 of 3 5000 Avienda Av.Fort Pierce,FL /