HomeMy WebLinkAboutProduct Approval Florida Building Code Online RECEIV~D MAR 2 9 2016Page 1 of 2
����� �'�;g; 1 3`fir;"� `�tr$ �� `,y�RF�k��t$�t a y^+� �` m9���� ,�w �,t•t xn� k
t��� '} � tX'�'FrY i �i ��� �j({Y.t'hE•"�'Yl� �+ C� ! �S�Y i ,4'kl ]Ijr�� fY 'R�4t 4y ^y) k1 '�`>-...__
x;�r€'yo,,�,���•tw `ty}}n 4 Y t��3Sy�bT x'h�jy���� r�z ��:.���rfi€?�.:t7�ilx'��y�; t ts. z 7� � x� i
*fSc�1� fi. i��'T�iGr1 s�+��`�1��•�} i�R" { �� ���!t�� 2��t�,�-�� 2 ,o- a,:. <#'°3� ' " _-�»r
ACFR� �dFM Y4�..GG�� R L � � i Iv-' � �" 'U7 ✓<! .'f f p '� (eyy,, R .i } ` q
M A! .v.4f sa8S5'a'W.1R?n..t. i'S.r•�•a..t•R`u.v.V#.'{f M..c. -{�XdY-7'MYLLyAvi'w.+Rm 4WnY. YJM�KEY.3)•'W!'nt�.�`Yp^"b �-1 M 5t_, ��.CAS NnT-..4.r.�,.4
J i:, w .r,Nr l= �; DCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff SCIS Site Mary Links Search
Business&`)
��) 430 ProductApproval
Professional �sER:P❑bli�user
y�must�nt+reR• Ila lu> >auL&aticutlisl>Application Detall
zq "k FL# FL17443
Application Type _
New
Code Version
Application Status Approved 11
Comments
Archived
Product Manufacturer I A TAYLOR ROOFING
Address/Phone/Email 302 Melton Drive
FT PIERCE,FL 34982
(772)466-4040
flvalidation@yahoo.com
Authorized Signature Kyte Taylor
flvalidation@yahoo.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category K \ Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Locke Bowden
Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/11/2021
Validated By Hermes F.Norero,P.E.
Validation Checklist- Hardcopy Received
Certificate of Independence FL17443 RO COI Certificate of In P end Locke Bowden P.E.__pdf
Referenced Standard and Year(of Standard) standard Year
UL580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method I Option D
https:Hgoridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtCUGgvjOiz6A%2brQi3pbzvra%2b%2flbg7g2KOBRzEzIHXSCw%3d°/*3d July28,2015
Florida Building Code Online Page 2 of 2
Date Submitted 03/02/2015
Date Validated 03/02/2015
Date Pending FBC Approval 03/05/2015
Date Approved 04/15/2015
Summary of Products
i- )-_- -.-....---..__..._ --
FL# j Model,Number or Name Description— ----
17443.1 15 V Crimp 26GA 1/2"rib height over 15/32"plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17443 RO II 5 V_Crimn Fasteninn Detail DVI
Approved for use outside HVHZ:Yes Verified By: PRI Construction Materials Technologies, LLC
Impact Resistant:N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-129.25 Evaluation Reports
Other:-129.25 @ 6"o.c.-69.25 @16"o.c. margin of safety E-1 U-143 RO AE FL 174., 3 J.A.Taylor Rr_ofinc:
2:1 with 24"max, coverage Install per manufacturers detail. Report ss.Ddf
Not For use in HVHZ. Created by Independent Third Party: Yes
LJ 0
Cnnt_art 11<;_1940 North Mom—Str nt Tallaha« FI 72799 Phone:A50-407-1824
The state of Florida Is an AAJEEO employer.Copyright 701717-7n I I state of Florid --Privacy Statement::AcrocsihiU4 Zai ampnt::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.if you have any questions,please contact:850.487.1395.'Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
.one.The emails provided may be used for official communication with the licensee.However email addresses are public-record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,
please click herr`.
ProductApproval Accepts:
wctlrltvfiv itwC
littps://floridabuiiding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtCUGgvjQiz6Ap/p2brQi3pbzvra%2b`/`2flbg7g2KOBRzEzIHXSCw%3dp/p3d July 2A,2015
l
Locke Bowden, P.E.
9450 Alysbury Place
Montgomery,AL 36117 FL # 17443
JA Taylor Roofing Inc
302 Melton Drive
Fort Pierce, FL 34982
Product:
5 V Crimp thru Fastened 1/2" rib at each panel edge and one in the center of the panel, 24" net coverage,
26GA min. over min.l 5/32"thick CDX plywood decks.
Compliance:Florida Building Code (FBC)2014; Section 1504.3.2, Section 1507.2.8, Section 1507.4.3
UL580 "Tests for Uplift Resistance"
Description: Architectural metal roof panel,26 gauge metal panels; over min. 15/32"CDX plywood
and shall comply with Florida Building Code 2014, Section 1507.4.3
Installation: Install per manufacturers install details in accordance with FBC 2014, Section 1507.4.2
Deck Slope 2:12 or greater and shall be compliant with Florida Building Code 2014, See tion 1507.4.2.
Design Pressure: -129.25 psf @ 6"o.c. and-69.25psf @16"o.c.; Fasten along the crown of the rib in the
center of panel and along the lap. Design pressure includes safety factor=2.0. First fastener to be within 3"
of panel edges. Min. 8d x 2"annular ring shank nails spaced 6" o.c. reroofing, with less than 19/32"plywood
9min. 15/32"), this attachment is to be used in addition to existing attachment. Deck attachment to be by
other design professional.
Underlayment: approved product in compliance with FBC 2014, Section 1507.2.8
Thru-fastened over min.1.5/32"plywood
Fasteners: #9-15 HWH corrosion resistant fasteners with seating washers, metal to wood connections with
fastener length to penetrate 5/16"through substrate per Florida Building Code 2014, Section 1507.4.4
Conditions of Use: Not for use in HVHZ. Install per manufacturer's instructions and must be designed
In compliance with Florida Building Code 2014. Manufacturer is compliant with Rule 61 G20-3; wherein
manufacturer complies under a quality assurance program audited by approved
Quality Assurance Entity; Keystone Certifications valid thru 4/11/2021
Evidence Submitted:
a. UL 580/TAS 125 Tests for Uplift Resistance
b. 1tererence-"Fest Report 0224-0501-06 Hurricane Test Laboratory ,�,tt111„ir,,,
C. "fest equivalency standard—the UL. 580-94 test standard is equ;xst�nuo 01 �)} ,16A0-06
d. Quality Assurance Procedures and Documentation �•~O�' � NSp °�
`�
v
Nt,. 704 0
1:1, Rte,/W RIV0';,�``
This report does nut guarantee or warranty any product validated or installed.MatufaclureCs warranty applies
5 V Crimp
Fastener-#9-15 corrosion resistant w/sealing washers
24" coveraae
Fastener: #9 x 15 corrosion resistant with sealing washers
in Compliance with 2014 Florida Building Code, Section 1507.4.4
Perimeter fastening: 6"o.c.
Main Field fastening 1 To.c.
Panel Width: 26"
Panel Coverage: 24"maximum
26 GA Architectural Metal Roof panel