Loading...
HomeMy WebLinkAboutEngineering r 10A TTY txTUT riI TATY it tiC:ldJ rrL°ju%,xt 21Ftp• Mechanical Electrical Civil Engineering 1984 S.W.Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772)785 -9888 Email pwelchinc@aol.com Re: Blair Re-Roof 10725 S. Ocean Drive Unit 519 Jensen Beach, FL 34957 SCOPE OF WORK: remove existing roofing and'instali=w5--V`Crimp Mviem— Roof(Gulf Coast Suppll & Manufacturing FL# 11651.13)at above referenced residence address over new underlayment and existing plywood sheathing DESIGN CRITERIA: FBC 2014 ASCE?-10 PROJECT DATA: BUILDING HIEGHT=9'-0" A=3' MEAN ROOF HIEGHT=<15' ROOF ANGLE=3:12 SHAPE=PITCHED GABLE HVIPROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 165 MPH WIND VELOCITY V asd= 124 MPH EXPOSURE=D ENCLOSURE CLASS =ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 A'PPT.TFD TTPT..TFT,n CTf_'N pT?FCCTTDrQ ON CT.nPFTI Dnnr 1"vn- LLNiV1. \M�a1• ZONE 1 (Field)=-44.7 ZONE 2 (Perimeter/Ridge)_-75.5 ZONE 3 (Comers)_-110.8 T7Ile1ch Paul We1ih=P:E:Reg.No 29945 - Maich 18,20-6 10725 S.Ocean Drive Unit 519 Jensen Beach,FL 34957 J =* 1 of 3 ATTA!'`AM VT i?FnTTM'Vi 1VTFNTC- WYv Metal roofing to be attached with#9 - 15 x 1 %2"long(minimum VV penetration through plywood sheathing)Woodgrip screws with weather sealing washers spacing as follows: ALL FASTENERS IN THE FLAT OF THE PANEL ZONE 1 (Field): Fasteners adincent to ribs one side(Tune 1 ner nroduct annroval) at 16" O.C. ZONE 2 (Perimeter/Ridge): Fasteners adjacent to ribs one side(Type 1 per product approval) at 16" O.C. ZONE 3(Corners): Fasteners adjacent to ribs both side(Type 2 per product approval) at 16" O.C. Zones 1 &2 Design uplift Pressure: -94.25 psf 7nnP I T)Pciam nnlifl PrPccnrP• - 111 0 nef �.-.�..s .- —.c.,.,t,,..�3,,..._...�mow,....-.--. ---_� .1-•-_ Zones 1 &2: 94.25 >75.5>44.7 Therefore O.K. Zone 3: 131.0> 110.8 Therefore O.K. NOTE: CONTINUOUS APPROVED LAP SEALANT MUST BE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:12. TTNiIFi?T.A VM['NT (nt,+:nn X11'• Underlayment shall be Polyglass USA, Inc. FL#5259.1 "Polystick TU Plus". Polystick TU Plus shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Section 1507. All seal-lap seams must be firmly rolled with a minimum 281b.hand roller to ensure full contact and adhesion. n1V,r l TNCT A T.Y.A TTn_N- Re-nail all plywood sheathing(15/32"thick minimum)with 8D ring-shank nails at 4" O.C. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (FL# 11651.13), (FL#5259.1), manufacturer's specifications,and the Florida Building Code 2014. PaaWe1ch,P.E Reg:-No:29945 March;i 8;-X016 2 of 3 10725 S.Ocean Drive Unit 519 Jensen Beach,FL 34957 %J ; = ~ M1 C eP ! SI GA ROOF ?l11►Ti, PI.A N A=3' {1 ,02,T3, =ZONE DESIGNATION(TYPICAL) NOTE: CONTINUOUS APPROVED LAP SEALANT MUST BE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS TITAN 3:12. Paul-Welch P.F:1 e�:Na. 299_45 -March 1-8,2016 == 3 of 3 10725 S.Ocean Drive Unit 519 Jensen Beach,FL 34957 - ''