Loading...
HomeMy WebLinkAboutProduct Approval T2412016 Florida Btnldina Code Online litBusiness & Professional' RequIatb* - :� - gda DepartmentsBC[S Home I Log In I User Registration I Hot Topic I Subit Surcharge Stats&Fads Publications I FBC Staff I BaS Site Mai Links I Searchsines Professi nal °�.I Product app'°val Regulation Product Approval Menu>Product or Application Search>Application Ll st>Application Detail • FL# FL11651-R2 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Gulf Coast Supply&Manufacturing, LLC. Address/Phone/Email 4020 S. W.449th Street Horseshoe Beach, FL 32648 (352)498-7852 ray@gulfcoastsupply.com Authorized Signature Ray Bowen ray@gulfcoastsupply.com Technical Representative Address/Phone/Email Quality Assurance Representative -Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from'a Florida Registered Architect or a Licensed Florida Professional Engineer -' Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Daniel S. Kuhn the Evaluation Report Florida License PE-75519 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/12/2024 Validated By Locke Bowden v', Validation Checklist-Hardcopy Received Certificate of Independence FL11651 R2 COI Cert of Ind Kuhn Eng.odf 811651 R2 COI Letter of Name change.gdf Referenced Standard and Year(of Standard) Standard Year FM 4471 1992 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 1897 2004 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code httpsJ/floridabuilding.org/pr/pr_app dil.aspx?param=wGEVXQwtDgsQFc5Kp/o2FTrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3dp/o3d 1/5 3/2412016 Florida Building Code Online Product Approval Method Method 1 option D Date Submitted 07/01/2015 Date Validated 07/10/2015 Date Pending FBC Approval 07/18/2015 Date Approved 08/18/2015 Summary of Products Go to Page 0 Page 1/20 0 FL# Madel,Number or Name Description 11651.1 0.032"Aluminum 5V Crimp 0.032"5 V Crimp Aluminum Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R2 II 14FL11651 1 R2 0325vCrimp 15_ Approved for use outside HVHZ:Yes 32Plvwood NonHVHZ.pdf Impact Resistant:N/A FL11651 R2 II 14FL11651 1 R2 Metal Roof Panel Detail.pdf Design Pressure: +N/A/-108.5PSF Verified By: Dan Kuhn, P.E. 75519 Other: -108.5 psf @ 12"o.c. Install per manufacturers Created by Independent Third Party:Yes details. Not for use in HVHZ Zones. Evaluation Reports FL11651 R2 AE 14FL11651 1 R2 0325vCrimp 15- 32Plywood NonHVHZ.p_df Created by Independent Third Party: Yes 11651.2 0.032"Aluminum Gulf Lok 0.032"Aluminum Gulf Lok 16"Wide Roof Panel over 15/32' Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 II 14FL11651 2 R2 032GulfLok 16 15- Approved for use outside HVHZ:Yes 32Plvwood NonHVHZ.odf Impact Resistant: N/A FL11651 R2 II 14F1,11651 2 R2 Metal Roof Panel Detail.Dddf Design Pressure: +N/A/-116.OPSF Verified By: Dan Kuhn, P.E. 75519 Other:-52.5 psf @ 5 3/16"o.c.fastener spacing. -116.0 Created by Independent Third Party: Yes psf @ 5 3/16"o.c.fastener spacing. Install per Evaluation Reports manufacturers details. Not for use in HVHZ Zones. FL11651 R2 AE 14FL11651 2 R2 032GulfLok 16 15- 32Plvwood NonHVHZ.pdf Created by Independent Third Party: Yes 11651.3 1"24ga. Gulf Snap 1"Gulf Snap 24 Ga. 17"wide Roof Panel-over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14EL11651 2 R2 Metal Roof Panel Detail.pdf Approved for use outside HVHZ:Yes FL11651 R2 II 14FL11651 3 R2 1 24Gu1fSnap 17 15- Impact Resistant:N/A 32Plywood HVHZ..pdf Design Pressure:+N/A/--131.OPS Verified By: Dan Kuhn, P.E. 75519 Other:-67.3 psf @ 24"o.c. dip spacing..-131 psf @ 6" Created by Independent Third Party:.Yes o.c. clip spacing. Install per manufacturers details. For use Evaluation Reports in HVHZ Zones. FL11651 R2 AE 14FL11651 3 R2 1 24GulfSnaD 17 15- 32Plvwood HVHZ..Ddf Created by Independent Third Party: Yes 11651.4 1"24ga.VersaLoc 1"Versa Loc 24ga 16.5"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 4 R2 24VersaLoc SR 16.5 IS- Approved for use outside HVHZ:Yes 32Plywood HVHZ..pdf Impact Resistant: N/A FL11651 R2 II 14FI-11651 4 R2 Metal Roof Panel Detail..Ddf Design Pressure: +N/A/-138.5PSF Verified By: Dan Kuhn, P.E. 75519 Other:-71 psf @ 24"o.c. clip spacing. -138.5 psf @ 6" Created by Independent Third Party: Yes o.c. clip spacing. Install per manufacturers details. For use Evaluation Reports in HVHZ Zones. FL11651 R2 AE 14FL11651 4 R2 24VersaLoc SR 16.5 15- 32_Plywood HVHZ..Ddf Created by Independent Third Party:Yes 11651.5 1"Versa Loc 032"Aluminum 1"VersaLoc.032"Aluminum over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 5 R2 lin 032VersaLoc SR 16 15- Approved for use outside HVHZ:Yes 32131ywood HVHZ..Ddf Impact Resistant:N/A FL11651 R2 II 14FL11651 5 R2 Metal Roof Panel Detail.,pdf Design Pressure: +N/A/-IOI.OPSF Verified By: Dan Kuhn, P.E. 75519 Other: -63.3 psf @ 24"o.c. clip spacing. -101.0 psf @ 6" Created by Independent Third Party: Yes o.c. clip spacing. Install per manufacturers details. For use Evaluation Reports in HVHZ Zones. FL11651 R2 AE 14FL11651 5 R2 lin 032VersaLoc SR 16 15- 32Plywood HVHZ..pdf httpsJffloridabuilding.org/pr/pr appdtl.aspxC?param=wGEVXOwtDgsOFc51C%2ffrZeCSHgtv99R5wgNNppMyNezj35i2E8F'O(1wwyA%3d%3d 215 3/2412016 Florida Buildina Code Online Created by Independent Third Party: Yes 11651.6 1.5' 24ga.Gulf Snap 1.5"Gulf Snap 24ga. 16"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 6 R2 1.5 24GulfSnaD 16 IS- Approved for use outside HVHZ:Yes 32Plvwood HVHZ..Ddf Impact Resistant:N/A FL11651 R2 II 14FL11651 6 R2 Metal Roof Panel Detail..pdf Design Pressure:+N/A/-116.OPSF Verified By: Dan Kuhn, P.E. 75519 Other:-86.0 psf @ 24"o.c.clip spacing.-108.5 psf @ 12" Created by Independent Third Party: Yes o.c.clip spacing. -116.0 psf @ 6"o.c. dip spacing. Install Evaluation Reports per manufacturers detals. For use in HVHZ Zones. FL11651 R2 AE 14FL11651 6 R2 1.5 24GulfSnap 16 15- 32Plvwood HVHZ..Ddf Created by Independent Third Party:Yes 11651.7 1.5" 24ga.VersaLoc 1.5"Versa Loc 24ga. 16"wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved foruse in HVHZ:Yes FL11651 R2 II 14FL11651 7 R2 1.5 24VersaLoc 16 15- Approved for use outside HVHZ:Yes 32Plywood HVHZ..pdf .Impact Resistant:N/A FL11651 R2 II 14FL11651 7 R2 Metal Roof Panel Detall-ndf Design Pressure: +N/A/-123.5PSF Verified By: Dan Kuhn, P.E.75519 Other.-59.75 psf @ 24"o.c. clip spacing. -123.5 psf @ 12" Created by Independent Third Party:Yes o.c. clip spacing. Install per manufacturers details. For use Evaluation Reports in HVHZ Zones. F111651 R2 AE 14FL11651 7 R2 1.5 24VersaLoc 16 IS- 32Plvwood HVHZ..Ddf Created by Independent Third-Party: Yes 11651.8 2"24ga. MegaLoc 24 Ga. 2"MegaLoc 18"wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 H 14FL11651 8 R2 24MegaLoc 18 15- Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.pdf Impact Resistant: N/A FL11651 R2 II 14FL11651 8 R2 Metal Roof Panel Detail pdf Design Pressure:+N/A/-108.SPSF Verified By: Dan Kuhn, P.E. 75519 Other:-71.0 psf @ 24"o.c. clip spacing. -108.5 psf @ 12" Created by Independent Third Party: Yes o.c. clip spacing. Install per manufacturers details. Not for Evaluation Reports use in HVHZ Zones. FL11651 R2 AE 14FL11651 8 R2 24MegaLoc 18 15- 32Plywood NonHVHZ.rdf Created.by Independent Third Party: Yes 11651.9 24 Ga. Gulf Lok 24 Ga. Gulf Lok 16"Wide over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 II 14FL11651 9 R2 24Gu1fLok 16 15- Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.odf Impact Resistant:N/A FL11651 R2 II 14FL11651 9 R2 Metal Roof Panel Detail pdf -Design Pressure:+N/A/-96.7PSF Verified By: Dan Kuhn,P.E. 75519 Other:-81.75 psf @ 10-1/4"o.c.fastener spacing. -96.76 Created by Independent Third Party: Yes psf @ 5-1/8"o.c.fastener spacing. -121.75 psf @ 5-1/8" Evaluation Reports fastener spacing. -161 psf @ 5-1/8"fastener spacing. FL11651 R2 AE 14FL11651 9 R2 24GulfLok 16 15- Install per manufacturers details. Not for use in HVHZ 32Plywood NonHVHZ.pdf Zones. Created by Independent Third Party: Yes 11651.10 24 Ga. Gulf Seam 24 Ga. Gulf Seam 16"Wide Roof Panel over 1x4 Wood Purlins over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 II 14FL11651 10 R2 24GulfSeam 16 1x4 15- Approved for use outside HVHZ:Yes 32Plvwood NonHVHZ.Ddf Impact Resistant: N/A FL11651 R2 II 14FL11651 10 R2 Metal Roof Panel Detail pdf Design Pressure: +N/A/-93.5PSF Verified By: Dan Kuhn, P.E. 75519 Other.-93.5 psf @ 18"o.c. Install per manufacturers Created by Independent Third Party: Yes details.Not for use in HVHZ Zones. Evaluation Reports F111651 R2 AE 14FL11651 10 R2 24GulfSeam 16 1x4 15- 32Plywood NonHVHZ.pdf Created by Independent Third Party: Yes 11651.11 24 Ga. Gulf Seam 24 Ga. Gulf Seam, 1 3/4"Snap Lock, 18"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R2 II 14FLIIGSI 11 R2 24GulfSeam 18 15- Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.odf Impact Resistant:-NIA F111651 R2 II 14FL11651 11 R2 Metal Roof Panel De ail Ddf Design Pressure: +N/A/-108.SPSF Verified By: Dan Kuhn, P.E. 75519 Other.-69.25 psf @ 24"o.c. clip spacing.-108.5 psf @ 12" Created by Independent Third Party: Yes o.c.clip spacing. Install per manufacturers.details. Not for Evaluation Reports. use in HVHZ Zones. FL11651 R2 AE 14FL11651 it R2 24GulfSeam 18 15- 32Plywood NonHVHZ.Ddf Created by Independent Third Party: Yes 11651.12 26 Ga. 5V Crimp 26 Ga. 5V Crimp Roof Panel over 15/32"Plywood MpsJ/floridabxdkLng.org/pr/pr app o.aspx?param=wGEVXQwtDgsQFc5K%2FfrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d°/a3d 315 3/24/2016 Florida Buikfina Code Online Limits of Use Installation Instructions Approved for use-in HVHZ..Yes FL11651 R2 II 14FL11651 12 R2 265vCrimp 15m Approved for use outside HVHZ:Yes 32Plvwood HVHZ.pdf Impact Resistant:N/A FL11651 R2 II 14FL11651 12 R2 Metal Roof Panel Detail.pdf Design Pressure: +N/A/-156.5PSF Verified By: Dan Kuhn, P.E.75519 Other:-108.5 psf @ 12"o.c. fastener spacing. -156.5 psf Created by Independent'Third Party:Yes @ 6"o.c. fastener spacing' r Install per manufacturers EvaluaVow Reports details. For use in HVHZ Zones. FL11651 R2 AE 14FL11651 12 R2 265vCrimp 15- 32Plywood HVHZ.pdf Created by Independent Third Party: Yes 11651.13 26 Ga. SV Crimp 26 Ga. 5V Crimp over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R2 II 14FL11651 13 R2 265vCrimp 15m Approved for use outside HVIM Yes 32Plvwood NonHVHZ.pdf Impact Resistant:N/A FL11651 R2 II 14FL11651 13 R2 Metal Roof Panel Detail.pdf Design Pressure—+N/A/-131.PSF Verified-By: Dam Kuhn,P:E 75519, Other:-94.25 psf @ 16"o.c.fastener pattern. -131.0 psf Created by Independent Third Party: Yes @ 16"o.c.,fastener pattern. Install.per manufacturers. Evaluation.Reports. details. Not for use in HVHZ Zones. FL11651 R2 AE 14FL11651 13 R2 265vCrimp 15- 32Plywood NonHVHZ.pdf Created by Independent Third Party:Yes 11651.14 26 Ga. 5V Crimp 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for,use in HVHZ:No- FL11_6.51 R2 II 14FL11651 14 R2 265vCrimp 1x4 15- Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.pdf Impact Resistant:N/A FL11651 R2 H 14FL11651 14 R2 Metal Roof Panel Detail.pdf Design Pressure: +N/A/-156.5PSF Verified By: Dan Kuhn,P.E.75519 Other.-108.5 psf Co)12"o.c. fastener spacing. -156.5 psf Created by Independent Third Party:Yes @ 6"o.c.fastener spacing. Install per manufacturers Evaluation Reports details. For use in HVHZ Zones. FL11651 R2 AE 14FL11651 14 R2 265vCrimp 1x4 15- 32Plywood NonHVHZ.pdf Created by Independent Third Party:Yes 11651.15 26 Ga. Gulf Lok 26 Ga. Gulf Lok 16"Wide Roof Panel over 15/32 Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 15 R2 26GulfLok 16 15- Approved for use outside HVHZ:Yes 32Plvwood HVHZ.Rdf Impact Resistant:N/A FL11651 R2 II 14FL11651 15 R2 Metal Roof Panel Detail.pd Design Pressure: +N/A/-161.OPSF Verified By: Dan Kuhn, P.-E.75519 Other.--63.5 psf @ 5 3/16"o.c.fastener spacing. -121.75 Created by Independent Third Party: Yes psf @ 5 3/16"spacing: 161.0 psf @ 5 3/16"ox. fastener Evaluation Reports spacing. Install per.manufacturers details. For.use in_HVHZ FL11651 R2 AE 14FL11651 15 R2 26GulfLok 16 15- Zones. 32Plvwood HVHZ.pdf Created by Independent Third Party: Yes 11651.16 26 Ga.Gulf Lok 26 Ga. Gulf Lok 16"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 II 14FL11651 16 R2 26GulfLok 16 15- Approved for use outside HVHZ:Yes 32131vwood NonHVHZ.pdf Impact Resistant:N/A F1_11651 R2 11 14FL11651 16 R2 Metal Roof Panel Detail.pd Design.Pressure:.+N/A/-63.5PSF Verified By:.Dan.Kuhn, P.E..75519 Other.-63.5 psf @ 5 3/16"o.c. fastener spacing. -121.75 Created by Independent Third Party: Yes psf @ S 3/16"fastener spacing. -161 psf @ 5 3/16"fastener Evaluation Reports spacing. Install per manufacturers details. Not for use in FL11651 R2 AE 14FL11651 16 R2 26Gu1fLok 16 15- HVHZ Zones. 32Plywood NonHVHZ.pdf Created by Independent Third Party: Yes 11651.17 26 Ga. GulfPBR 26 Ga. Gulf PBR Roof Panel over 15/32"Plywood Limits of Use Installation Instructions- Approved for use in HVHZ:No FL11651 R2 II 17 R2 26GulfPBR 15-32Plvwood NonHVHZ Ddf Approved for use outside HVHZ:Yes FL11651 R2 II 17 R2 Metal Roof Panel Detail.Ddf Impact Resistant:N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-154.7PSF Created by Independent Third Party: Yes Other.-59.25 psf @ 24'o.c. fastener pattern. -154.75 psf Evaluation Reports @ 12"o.c. fastener pattern. Install per manufacturer FL11651 R2 AE 17 R2 26GulfPBR 15- details: Not for use-in-HVHZ 32Plvwood NonHVHZ.pdf Created by Independent Third Party:Yes 11651.18 26 Ga. GulfPBR 26 Ga. GulfPBR Roof Panel over 1x4 Wood Purlins over 15/32' Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 18 R2 26GulfPBR 1x4 15- Approved for use outside HVHZ:Yes 32Plvwood HVHZ.Ddf Impact Resistant: N/A FL11651 R2 II 18 R2 Metal Roof Panel Detail.pdf Design Pressure:+N/A/-151.7PSF Verified By: Dan Kuhn,P.E. 75519 httpsY/Horidabdldir_q.orglpr/pr app o.aspx?param=wGE1/XQwtDgsQFc5,�/o2tTrZeGSHgw99R5wgNNppMyNezj3512E8POQwgA%3d°/a3d 4/5 3/24IM16 Florida Building Code Offline (Other.-100.5 psf @ 24'o.c. fastener spacing. -151.75 psf Created by Independent Third Party: Yes @ 12"fastener spacing.Install per manufacturer's details. Evaluation Reports For use in HVHZ Zones FL11651 R2 AE 14FL11651 18 R2 26Gu1fPBR 1x4 15- 32Plvwood HVHZ.Ddf Created by Independent Third Party: Yes 11651.19 26 Ga. GulfPBR 26 Ga. GulfPBR over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 19 R2 26GulfPBR 15- Approved for use outside HVHZ:Yes 32Plvwood HVHZ.Ddf Impact Resistant:N/A FL11651 R2 II 19 R2 Metal Roof Panel Detail.pdf Design Pressure:+N/A/-154.7PSF Verified By: Dan Kuhn, P.E. 75519 Other.-60.5 psf @ 24'o.c. fastener spacing. -154.75 psf Created by Independent Third Party:Yes @ 12'o.c.fastener spacing. Install per manufacturer's Evaluation Reports details.For use in HVHZ Zones. FL11651 R2 AE 14FL11651 19 R2 26GulfPBR 15- 32Plywood HVHZ.pdf Created by Independent Third Party:Yes 11651.20 26 Ga.GulfPBR 26 Ga.GulfPBR over 1x4 Wood Purlins over 15/32"Plywood Limits of Use Installation instructions Approved for use in HVHZ:No FL11651 R2 II 20 R2 26GulfPBR 1x4 15- Approved for use outside HVHZ:Yes 32Plvwood NonHVHZ.Ddf Impact Resistant:N/A FL11651 R2 II 20 R2 Metal Roof Panel Detail.pdf Design Pressure: +N/A/-151.7PSF Verified By: Dan Kuhn,P.E. 75519 Other:-94.25 psf @ 24"o.c.fastener spacing. -151.75 psf Created by Independent Third Party:Yes @ 12"fastener spacing.Install per manufacturer's details. Evaluation.Reports Not for use in HVHZ Zones FL11651 R2 AE 20 R2 26GulfPBR 1x4 1S- 32Plywood NonHVHZ.pdf Created by Independent Third Party:Yes Go to Page 0 Pagel/20 0 Back Next Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer Ceu nicht 2007-2013 State of Florida.:.-Privacy Statement::Acoesibility Statement:_Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 10.487.1395:'Pursuant to.Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which-can be made available to the public To determine if youarea-licer>see under Chapter 455,F.S.,please did,here- Product Approval Accepts: ®® R9i`] sccuritv�u;reres• httpsJ/BoridaWlcing.orgfWpr app�M-aspx?param=wGEVXQwiDgsQFcW/o2fTrZeCSHgw99R5wgNNppMyNe2j3512E8POQwgA%3d%3d 515 00, LORI DA PR ® , GuIfCod�t SUPPLY & MANUFACTURING 26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD* RI P FLORIDA PROD APPROVAL NO. 11651.13 R2 TM Product Evaluation Report GULF COAST SUPPLY& MANUFACTURING, LLC: 26 Ga. 5V Crimp Root Panel over 75/32"Plywood Florida Product Approval #11651.13 R2 Florida Building Code 2014 Per Rule 61 G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 ;O'r1I CSS. ,ir'°°, L� NSA by - s Engineer Evaluator: *: No. 75519 Dan Kuhn, P.E. #75519 _ Florida Evaluation ANE ID: 10743 STATE OF ."AZ - C Validator: ;;ass•. on IV P.•���: ���s�OAL Locke Bowden, P.E. #49704 ,, IVf sill�e t, 9450 Alysbury Place o6130 l Montgomery, AL 36117 / Contents: Evaluation Report Pages 1 - 5 FL#11651.13 R2 @ JUNE 15,2015 . . ® , ENGINEERING,KUHN 00, FL-ORIDA PRODUCT APPROVAL GUIX06�t SUPPLY & MANUFACTURING R P 26 GA. P ROOF PANEL . PLYWOOD* O . DA PRODUCT APPROVAL NO. 11651.13 R2 TIVI Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Product Description: 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened roof panel with fasteners in the panel flat over minimum 15/32" plywood decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel,ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2014 Section 1507.4.3. Paint Finish Optional Yield Strength: 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2014, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 24" Coverage Rib Height: 3/8" Major Rib Panel Fastener: #9-15x1.5" with sealing washing in the flat of the panel or approved equal, 1/a" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4 Substrate Description: Minimum 75/3 " thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2014. Design Uplift Pressures: Table"A" Maximum Total Uplift Design Pressure 9425 psf 1`31.0 psf Fastener Pattern 12"-12" 9.5"-2"-9.5" Fastener Pattern Spacing 16",O.C. 1'6" O.C. Design Pressure includes a Safety Factor=2.0. FL#11651.13 R2•JUNE 15,2015 . . ® • ® ® . ENGINEERING,KUHN 00, F�L;O�R�:ID;A ,P,RODUCT' APPROVAL GulfcoaA SUPPLY & MANUFACTURING 5VC RI P 26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD* FLORIDA PRODUCT APPROVAL NO. 11651.13 R2 TM Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: ® UL 580-06-Test for Uplift Resistance of Roof Assemblies ® UL 1897-04- Uplift Test for Roof Covering Systems_ Reference Data: 1. UL 580-94/ 1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization#TST-5328) Report No. 117-0053T-05 & 117-0331 T-08 2. Certificate of Independence By Dan Kuhn, P.E. (FL#75519)@ Kuhn Engineering, LLC (FBC Organization#ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. FL##11651.13 R2•JUNE 15,2015 PROD . ® ® e e . ■ FLORIDA . . ® , • Gu-o#*If C&'ist SUPPLY & MANUFACTURING 5V RI RN P 26 GA. P ROOF PANEL . PLYWOOD* FLORIDA PRODUCT APPROVAL NO. 11651.13 I .' TM Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design.The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL#11651.13 R2-JUNE 15,2015 PRODUCT EVALUATION, REPORT ENGINEERING,KUHN 71 G-u00 0 01 f C o'�'kt ENGINEIIER",-5 LOAD TARLE SPEC SUPPLY & MANUFACTURING 5 V CRIMP 26 GA. ROOF PANEL . PLYWOOD* FLORIDA PRODUCT APPROVAL NO. 11651.13 R:' TM ENGINEER LOAD TABLE:26 Ga. 5VCrimp Roof Panel over 15/32"Plywood Buildings having;a Roof Mean Height :!c 20'-0"; Roof Slope: 2"112" - 12"/12" Gable,or Hip Roof,Wind Speeds 120- 180rnph Exposure C,.Risk Category Ii, Enclosed Building, based on Florida Building Code 2014. 120 130 140 150 160 170 180 W11ND FASTENER SUBSTRATE (MIN.1/4" SPEED penetration) (MIN.15(32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER. SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZONE 1 #9-15x7.S" Plywood 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 ZONE 2 #9-15x1.5" Plywood 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 ZONE 3 #9-15x1.5" Plywood 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 2 16"TYPE 2 1.)PANEL DESCRIPTION:5V CRIMP,MIN.26 GA.,GRADE 80,24"COVERAGE. 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER W/MIN. A" PENETRATION_ 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:-94.25 PSF@ 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN,-131.0 PSF @16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.)PLYWOOD DECKING:MIN.15/az"THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014. 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12,LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2014 ZONE 2 HIP ROOF a Note:Dimension(a)is defined as 10%of the minimum width of the building or r ——————— ZONE 3 �1 a 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be \ --—--- , less than either 4%of the minimum width of the building or 3 feet. RIDGE---- ----- ��' ,� , TYPE 1 FASTENER PATTERN - ---- `\ (1) #9-15 x 1-1/2" HWH w/Sealing Washer ZONE1 12 12" /------------------- SAVE At Panel Lap ZONE 2 (,Age ROOF a --T- ------------------ TYPE 2 FASTENER PATTERN --RIDGE ' � ��(1) #9-15 x 1-1/2 HWH w/Sealing Washer I I ----- -- ------- I ZONE 1 I I �I --------------------- t ZONE 3 SAVE FL#11651.13 R2.JUNE 15,2015 . . ! ® UCT EVALUATION REPORT ENGINEERING,KUHN 11670 I.SLANI),LAKES LANE. BOCA RATON. 3124/2016 Florida Building Code Online I. s • • 0 / . Regulation Florida Departmentof Bc's Home I L-g I- I user"r—U. I is Too. I submit surcharge I stats&Facts I w,efcations I Fee stair I acts site map I r;nks I search I BusinesOUSER: ProductApproval Professi nal "icuser Regulation Product Approval Menu>Product or Application Search>Anolication List>Application Detail •�2j FL# FL5259-R24 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall tie-reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived - Product Manufacturer POLYGLASS USA Address/Phone/Email 150 Lyon Drive Fernley, NV 89408 (570)384-1230 Ext 242 jakins@polyglass.com Authorized Signature James Akins jakins@polyglass.com Technical Representative Steve Wadding Address/Phone/Email 150 Lyon Drive Fernley,NV 98408 M2)363-7139 stevew@polyglass.com Quality Assurance Representative James Akins Address/Phone/Email 555 Oakridge Road Humboldt Industrial Pkwy Hazleton,PA 18201 (800)894-4563 jakins@polyglass.com Category Roofing Subcategory Underiayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Ronda Professional Engineer L,*1 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/01/2017 Validated By John W. Knezevich, PE I1-6 Validation Checklist-Hardcopy Received Certificate of Independence FL5259 R24 COI 2015 01 COI Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2009 ASTM D226 2006 ASTM D6164 2005 ASTM D6222 2008 https://fiondabtdlcing.orgfpr/pr appo.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2feg0iipH82Cu7FMfVnJrJdOHoR9p/o2fA%3d%3d 1/2 3(24/2016 Florida Building Code Online ASTM G154 2006 ASTM GISS 2005 FM 4474 2004 FRSA/TRI Aoril 2012 2012 TAS 103 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 07/22/2015 Date Validated 08/07/2015 Date Pending FBC Approval 08/15/2015 Date Approved 10/16/2015 Summary of Products FL ft Model,Number or Name Description 5259.1 Polyglass Roof Roofing underlayments Underlayments Limits of use Installation Instructions Approved for use In HVHZ:No FL5259 R24 II 2015 07 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- Approved for use outside HVHZ:Yes R24.12d Impact Resistant:N/A Verified By:Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party:Yes Other. 1.)The design pressure in this Evaluation Reports application relates to one particular FL5259 R24 AE 2015 07 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- underlayment system(over concrete deck)for R24.pdf use under foam-on the systems(where the Created by Independent Third Party: Yes underlayment forms part of the load-path). Refer to ER Section 5.6.4 for other systems, other deck types and associated maximum design pressures. 2.)Refer to ER Section 5 for other limits of use. Back Next Contact us::1940 North Monroe Street.Tallahassee FL 32399 Phone:550-487-1924 The State of Florida is an AAfEEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail aft ass released in response to a pubtirrecords request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have arty questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official eDmmunication with the licensee.However email addresses are public me d.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dirk hem. Product Approval Accepts: ®®ElM sccuritv,%i•:Twcs https:/MoridaWidirxf.orgtpr/pr appd8 aspxyparam=wGEVXQwtDgvbSgAaZp3Crk2vS%2feq01ipH82Cu7FMtVrtJr ldOHoR9%2FA%3d%3d 212 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 TRINITY ERD 353 CHRISTIAN STREET,UNIT#13 OXFORD,CT 06478 PHONE: (203)262-9245 FAX: (203)262-9243 EVALUATION REPORT Polyglass USA,Inc. Evaluation Report P12060.02.09-R20 150 Lyon Drive FL5259-R24 Fernley, NV 98408 Date of Issuance:02/24/2009 Revision 20:07/22/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 12. Prepared by: * = The facsimile seal a '_ • ppearing was authorized by Robert Nieminen, 4k,= P.E.on 07/22/2015. This does not serve as an electronically Robert J.M.Nieminen P.E. signed document. Signed,sealed hardcopies have been Florida Registration No.59166,Florida DCA ANE1983 • °�O�ta� :�` transmitted to the Product Approval Administrator and to the � ��,,, ,� named client CERTIFICATION OF INDEPENDENCE: I. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity l ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. QOTFuNffyIERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Prope Standard Year 1504.3.1 Wind Uplift FM 4474 2004 1504.6 Accelerated Weathering ASTM G154 2006 1504.6 Accelerated Weathering ASTM G155 2005 1507.2.3,1507.3.3,1507.5.3,1507.7.3, Physical Properties ASTM D226 2006 1507.8.3,1507.9.3 1507.2.4,1507.2.9.2,1507.5.3,1507.7.3 Physical Properties ASTM D1970 2009 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2008 1507.3.3 Installation Practice FRSA/TRI April 2012 2012 1523.6.5.2.1 Physical Properties TA5103 1995 3. REFERENCES: Entity Examination Reference Date FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000 PRI(TST 5878) Physical Properties PRI01111 04/08/2002 PRI(TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI(TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI(TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI(TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI(TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI(TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI(TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI(TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI(TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI(TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI(TST 2508) Physical Properties JX20H7A 04/01/2008 MTI(TST 2508) Physical Properties RX14E8A 01/29/2009 ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD(TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD(TST 6049) Wind Uplift P30540.11.09-111 11/30/2009 ERD(TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD(TST 6049) Physical Properties P11030.11.09-3 11/30/2009 ERD(TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD(TST 6049) Physical Properties P33370.03.11 03/02/2011 Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20 Certificate of Authorization#9503 FL5259-R24 Revision 20:07/22/2015 Page 2 of 12 OTPuNITYIERD Entity Examination Reference Date ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD(TST 6049) Physical Properties P37300.10.11 10/19/2011 ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 ERD(TST 6049) Wind Uplift P11781.11.03-111 11/26/2013 ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014 ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-2 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.144 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014 ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD(TST 6049) Physical Properties P44360.10.14 10/07/2014 ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014 ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015 ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015 ERD(TST 6049) Wind Uplift PLYG-SC8905.15 07/22/2015 ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014 Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA PA Affidavit Mule-Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 ULLLC.(QUA9625) Quality Control Service Confirmation,R14571 Exp.08/08/2015 WLLC.(QUA9625) Quality Control Service Confirmation,MTS PLUS Exp.07/01/2017 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlayments: 4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet. 4.2 Self-Adhering UnderlaVments: 4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced -with polyolefinic film surface;meets ASTM D1970 and TAS 103. 4.2.2 Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with poly-film surface;meets TAS 103. 4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface;meets ASTM D1970. 4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103. 4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane,glass-fiber/polyester reinforced, with a granular surface;meets ASTM D1970 and TAS 103. 4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface;meets ASTM D1970 and TAS 103. Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-1120 Certificate of Authorization#9503 FL5259-R24 Revision 20:07/22/2015 Page 3 of 12 OTP'.INITYIERD 4.2.7 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester reinforced,APP modified bitumen cap sheets;meet ASTM D6222. 4.2.8 Polystick Dual ProTm is a nominal 60-mit thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970. 4.2.9 Polystick Tile ProTm is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103. 4.3 Mechanically Fastened and/or Bonded Underlayments: 4.3.1 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets;meet ASTM D6164. 4.3.2 Polyflex G and Polyflex G FR are polyester reinforced,APP modified bitumen cap sheets;meet ASTM D6222. S. WITATION5: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPnONs Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal Wood Shakes& Slate Shingles Yes Yes Elastobase Yes (base layer int-ply (base layer in 2-ply Yes Yes Yes system) system) Yes Yes Elastobase P Yes (base layer in 2-ply (base layer in 2-ply Yes Yes Yes system) system) Polystick MTS Yes Yes No Yes Yes Yes Polystick MTS PLUS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU P Yes Yes Yes No Yes Yes See 5.5.1 Polystick TU Plus Yes yes Yes Yes Yes Yes See 55.1 Polystick TU Max No Yes Yes Yes No No See 55.1 Polystick Dual Pro Yes Yes No Yes Yes Yes Polystick Tile Pro Yes Yes Yes Yes Yes Yes See Sal Elastoflex S6 G Yes Yes Yes No Yes Yes See 55.1 Elastoflex S6 G FR Yes Yes No No Yes Yes Polyflex G Yes Yes Yes No Yes Yes See 5.5.1 Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes No Yes Yes See 55.1 Mule-Hide SA-APP Cap Sheet Yes Yes Yes No Yes Yes or SA-APP Cap Sheet(FR) See 5.5.1 Exterior Research and Design,LLC. Evaluation Report P32060.02.09-1120 Certificate of Authorization#9503 FL5259-R24 Revision 20:07/2212015 Page 4 of 12 Q0TRINITYIERD 5.5.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ✓ 3MTm 2-Component Roof Tile Adhesive AH-160 (FL6332): Polystick TU P, Polystick TU Plus, Polystick TU Max, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)or Tile Pro. ✓ 3M1 Foam Roof Tile Adhesive RTA-1(FL6276): Polystick TU P, Polystick TU Plus, Polystick TU Max, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) or Tile Pro ✓ Dow TileBond(FL717): Polystick TU P,Polystick TU Plus, Polyflex SAP or Tile Pro ✓ Convenience Products'Touch 'n Seal StormBond Roof Tile Adhesive (FL14506): Polystick TU Plus, Polystick TU Max 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Polystick(all variations), Dual Pro,Tile Pro, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)self-adhered to: ➢ New untreated plywood;ASTM D41 primed new untreated plywood; Existing plywood;ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note:Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex S6 G or S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or G FR torch-applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond-to-Insulation: Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)self-adhered to: ➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard;Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board. Elastoflex S6 G or S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. Polyflex G or G FR torch-applied to: ➢ ASTM D41 primed structural concrete;Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20 Certificate of Authorization#9503 FL5259-R24 Revision 20:07/22/2015 Page 5 of 12 TRINITY I ER® 5.6.3 Bond to Mechanically Attached Base Laver: Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR) Dual Pro or Tile Pro self-adhered to: ➢ ASTM D226,Type I or II felt;Elastobase;Elastobase P or Mule-Hide Nail Base. Elastoflex S6 G or 56 G FR in hot asphalt to: ➢ ASTM D226,Type I or 11 felt;Elastobase;Elastobase P or Mule-Hide Nail Base. Polyflex G or G FR torch-applied to: ➢ Elastobase; Elastobase P or Mule-Hide Nail Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12),Appendix A,Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04- 12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads. 5.6.4.1 Maximum Design Pressure=-90 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.2 Maximum Design Pressure=-135 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)PG100 or ASTM D41 Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints. Base Ply: (Optional)Polystick MTS PLUS;self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.3 Maximum Design Pressure=-315 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P, Polystick TU Plus,Polystick TU Max,Tile Pro,Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.4 Maximum Design Pressure=-622.5 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: PG100 or ASTM D41 Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.5 Maximum Design Pressure=-30.0 psf*. Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20 Certificate of Authorization#!9503 FL5259-11124 Revision 20:07/22/2015 Page 6 of 12 QoTs.vrryIERD 5.6.4.6 Maximum Design Pressure=-37.5 psf*. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.7 Maximum Design Pressure=-37.5 psf*. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.8 Maximum Design Pressure=-45 psf*. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: One(1)layer ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.9 Maximum Design Pressure=-45 psf*. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.10 Maximum Design Pressure=-45 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.11 Maximum Design Pressure=-52.5 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.12 Maximum Design Pressure=-52.5 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20 Certificate of Authorization#9503 FL5259-R24 Revision 20:07/22/2015 Page 7 of 12 TRII rry I ER® 5.6.4.13 Maximum Design Pressure=-52.5 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.14 Maximum Design Pressure=-60 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.15 Maximum Design Pressure=-60 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.16 Maximum Design Pressure=-90 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.17 Maximum Design Pressure=-90 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.18 Maximum Design Pressure=-90 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.19 Maximum Design Pressure=-97.5 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.20 Maximum Design Pressure=-105 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20 Certificate of Authorization#9503 FL5259-R24 Revision 20:07/22/2015 Page 8 of 12 QOTRINITYIERD 5.6.4.21 Maximum Design Pressure=-112.5 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin-caps Base Ply: Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.22 Maximum Design Pressure=-120 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgnp or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.23 Maximum Design Pressure=-120 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.24 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on the systems carry a Maximum Design Pressure of-45 psf. 5.6.4.25 For mechanically attached base sheet in a 2-ply system,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FRSA/TRI April 2012 (04-12),Appendix A, Table 1A or FBC 1609. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD1. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobase or Elastobase P shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe shall not be left exposed for longer than 90-days after installation. Polystick MTS, MTS PLUS,TU P, TU Plus,TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 180- days after installation. Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile, in which case the maximum exposure is 30 days. Elastoflex S6 G or S6 G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20 Certificate of Authorization#9503 FL5259-R24 Revision 20:07/22/2015 Page 9 of 12 (T�RINITYJERD 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the.Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Elastobase,Elastobase P or Mule-Hide Nail Base: 6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226,Type II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile Applications: Reference is made to the current edition of the NRCA Steep-slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings ' Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR),Dual Pro or Tile Pro,self-adhered,Elastoflex S6 G or 56 G FR in hot asphalt or Polyflex G or G-FR,torch applied. 6.3.3 Tile Applications: Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted above as a guideline. 6_4 Polystick MTS,MTS PLUS,IR-Xe,TU P,TU Plus,TU Max Polyflex SAP or SAP FR Mule-Hide SA-APP Cap Sheet or SA- APP Cap Sheet(FR),Dual Pro or Tile Pro: 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers: All self-adhering materials,with the exception of Polystick TU Plus,Polyflex SAP or SAP FR and Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule-Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter metal disk or Simplex-type metal cap nail,at a minimum rate of 12"o.c. Polystick TU Plus should be back-nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back-nailed All seal-lap seams (selvage laps) must be c. � - . '-_:'• • firmly rolled with a minimum 28 Ib. hand . roller to ensure full contact and adhesion. L P ; For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). View of Ovelap Seam of Dual Pro and Tile Pro All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus,Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20 Certificate of Authorization x/9503 FL5259-RZ4 Revision 20:07/22/2015 Page 10 of 12 QTRINrryIERD Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-Ib weighted-roller or,on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches,laps(min.28 Ib roller)or small areas of the roof that are.not accessible to a large roller or broom. 6.4.3 Tile Applications(not allowed for Polystick IR-Xe): Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened the roofing over 2-ply system,consisting of base sheet and self-adhering top sheet(s), base sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1. For adhesive-set tile applications,refer to Section 5.6.4 herein. For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile. For nail-on tile systems over Polystick MTS PLUS: A Battens are required for loading/staging of lugged the regardless of slope. ➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12. 6.4.4 Two(2)Ply Underlayment Systems: Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS,TU P,TU Plus, TU Max,TilePro or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired. Polystick MTS PLUS followed by Polystick TU P,TU Plus, TU Max, TilePro or Polyflex SAP is allowable for use under foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. 6.5 Elastoflex S6 G or S6 G FR: 6.5.1 Elastoflex S6 G or S6 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications,reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein. 6.5.2 Elastoflex S6 G or S6 G FR shall be fully asphalt-applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 Polyflex G or G FR: 6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications,reference is made FRSA/TRI April 2012(04-12) Installation Manual and Table 1 herein. 6.6.2 Polyflex G or G FR shall be fully torch-applied to the substrates noted in Section 5.6. Side laps shall be minimum 3- inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6_7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Polyglass published requirements for the staging. 6.7.2 Battens and/or Counter-battens,as required by the the manufacturer and FRSA/TRI April 2012(04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail- boards,to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20 Certfcate of Authorization#9503 FL5259-R24 Revision 20:07/22/2015 Page 11 of 12 0 TRINrry l ERD 6.7.4 For nail-on tile systems over Polystick MTS PLUS: ➢ Battens are required for loading/staging of lugged the regardless of slope. • Battens are required for loading/staging of flat tile at slopes in excess of 5:12. 6.7.5 The minimum cure time after installation of self-adhering membranes and before loading of roofing tiles is forty-eight (48)hours. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C.Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com --END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 1)12060.02A9=R20 Certificate of Authorization#9503 FL5259-1124 Revision 20:07/22/2015 Page 12 of 12