HomeMy WebLinkAboutEngineering T!A TTY tx7TT d-xx TAT!" tr:vtu rri.tj%.tt tlrt.. Mechanical Electrical Civil Engineering 1984 S.W.Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772)785 -9888 Email pwelchffic@aol.com. ?4401-nl, 12 Ityl A Re: Blair Re-Roof 10725 S. Ocean Drive Unit 519 Jensen Beach,FL 34957 SCOPE OF WORK: Remove existing roofing and�insialr new 5-V Crimp ivietai Roof(Gulf coast Supp' & Manufacturing FL# 11651.13) at above referenced residence address over new underlayment and existing plywood sheathing DESIGN CRITERIA: FBC 2014 ASCE?-10 PROJECT IATA: BUILDING HIEGHT=9'-0" A=3' MEAN ROOF HIEGHT=<15' ROOF ANGLE=3:12 SHAPE=PITCHED GABLE DAPROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 165 MPH WIND VELOCITY V asd= 124 MPH EXPOSURE=D ENCLOSURE CLASS =ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 A-PPT IED TTPT.TFT nl CT!"_N PDD CCTTRFC nN CT.nPF1%Vnn1i lnefl- ___ \Neal• ZONE 1 (Field)=-44.7 ZONE 2(Perimeter/Ridge)_-75.5 ZONE 3 (Corners)_-110.8 b,KKC'f`t VLL 1LLV. -Paul Welch P.E.Reg.-,Nb.--29945 - W-c418,2016, 1 of 3 10725 S.Ocean Drive Unit 519 Jensen Beach,FL 34957 `: _ _ ATTAf'A =I%TTDIWATTY1D TNFATTC• .�,v_ Metal roofing to be attached with#9- 15 x 1 %2"long(minimum V4"penetration through plywood sheathing)Woodgrip screws with weather sealing washers spacing as follows: ALL FASTENERS IN THE FLAT OF THE PANEL ZONE 1 (Field): Fasteners adjacent to ribs one side(Type 1 per product approval) at 16" O.C. ZONE 2 (Perimeter/Ridge): Fasteners adjacent to ribs one side(Type 1 per product approval) at 16" O.C. ZONE 3 (Corners): Fasteners adjacent to ribs both side(Type 2 per product approval)at 16"O.C. Zones 1 &2 Design uplift Pressure: -94.25 psf 7nnP I T)P.A n nnlifl Pr .Q-.nrP.- - 111 n naf Zones 1 &2: 94.25 >75.5>44.7 Therefore O.K. Zone 3: 131.0> 110.8 Therefore O.K. NOTE: CONTINUOUS APPROVED LAP SEALANT MUST BE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:12. TTNiIFT?T.A VMFNT lnn+:nn �1 1. Underlayment shall be Polyglass USA,Inc. FL#5259.1 "Polystick TU Plus". Polystick TU Plus shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Section 1507. All seal-lap seams must be firmly rolled with a minimum 281b.hand roller to ensure full contact and adhesion. 'nIV f W TTVCT ATT.A T FnV- Re-nail all plywood sheathing(15/32"thick minimum)with 8D ring-shank nails at 4"O.C. perimeter and 6"O.C. field for all zones. All work to be in compliance with product approval (FL# 11651.13), (FL# 5259.1), manufacturer's specifications, and the Florida Building Code 2014. Paul Welch P.E. Reg.I,To.29945 M&616 i k'_2016-- _ 10725 S.Ocean Drive Unit 519 Jensen Beach,FL 34957 2 of 3 j � f3 � ► OLD ft Z; Z 3 3 =Ec taA u DnnTa.ZONE ,AN, AAT A=3' 1Q,Q(3,=ZONE DESIGNATION(TYPICAL) NOTE: CONTINUOUS APPROVED LAP SEALANT MUST BE USF.D,A.T ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:12. F = Pµ, l NI e�, TL-c. haul Welch 1--E.Reg.96.29945 1Vla.J� j 201-Fi 10725 S.Ocean Drive Unit 519 Jensen Beach,FL 34957 ti -- % 3 of 3