Loading...
HomeMy WebLinkAboutProduct Approval ` Florida Building Code Online Page 1 of 5 Y 3 ✓ 0110a Depn r.` BCIS Home Log In'T-Use Ion Hot Topics Submit Surcharge Stats&Facts Publications i FBC Staff BCIS Site Map s Links Search Business O rbc Product Approval Professional (y' USER:Public User Pycduct Aourov Menu>P otluct A II ation Search>Acoiication LK Application Detail �\ 1# FL14911 R7 E Application Type Revision , Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Silverline Building Products Corp. Address/Phone/Email One Silverline Drive North Brunswick,NJ 08902 (800)234-4228 Ext 4644 Jonberrian@slbp.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Jon Berrian Address/Phone/Email One Silverline Drive North Brunswick,NJ 08902 (732)435-1000 Jonberrian@slbp.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer if' Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity Window and Door Manufacturers Association-QA Quality Assurance Contract Expiration Date 10/21/2016 Validated By Ryan J. King,P.E. Validation Checklist-Hardcopy Received Certificate of Independence F�_17.9_S_S_,R7._COI.._Certitic;ate.._Of,_Inependence 2;,.Idf Referenced Standard and Year(of Standard) Standard Year AAMA/W D MA/CSA/101/I.S.2/A440 2008 AAMA/W D MA/CSA/101/I.S.2/A440 2011 ASTM D1929 1996 ASTM D2843 1993 ASTM D635 1996 ASTM D638 1996 ASTM E1886 2005 ASTM E1996 2009 ASTM G26 1995 TAS 201,202 and 203 1994 I https:Hfloridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquZRj 59%2fDrx2l bt... 3/22/2016 Florida Building Code Online Page 2 of 5 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL14911 R7 Equiv Equivalency Of Stanrlards.pdf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/02/2015 Date Validated 04/13/2015 Date Pending FBC Approval 04/16/2015 Date Approved 06/23/2015 Summary of Products Go to Page Pagel/2 FL# Model,Number or Name Description 14911.1 a. S 2900/4900-M 2901/4901 Single Hung Extruded Vinyl Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R7 II Inst 14911.1.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 14911.1 for Design Pressure Ratings,any FL1.4911 R7 AE Eval 14911.1.pcif additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 14911.2 b. S 2900/4900-M 2901/4901 "Oriel"Extruded Vinyl Single Hung Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 II Inst 14911.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.2 for Design Pressure Ratings,any FL1.4911 R7 AE Eval 14911.2.pdf additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. l 14911.3 c.Series 2900/4900 Models Single Hung Extruded Vinyl Window with Nailing Fin 2901/4901"Weather Stopper" Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 II Inst 14911,3.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant.Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.3 for Design Pressure Ratings,any FL14911 R7 AE Eval 1.4911.3.1)df additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. (Note-See 14911.24 for Wind Zone 4 and HVHZ Impact Product) 14911.4 d. S 2900/4900-M 2902/4902 Twin-Single Hung Continuous Head and Sill Extruded Vinyl Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 II Inst 14911.4.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.4 for Design Pressure Ratings,any FL14911 R7 AE Eval._14911.4,.1)df additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 14911.5 e.S 2900/4900-M 2903/4903 Triple-Single Hung Continuous Head and Sill Extruded Vinyl Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 II Inst 14911.5--pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 14911.5 for Design Pressure Ratings,any FL14911 R7 AE Eva[ 14911.5.pdf j additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquZRj 59%2fDrx2l bt... 3/22/2016 Florida Building Code Online Page 3 of 5 i 14911.6 f. S 2900/4900-M 2901/4901 Single Hung Extruded Vinyl Window-Flange with Strap Anchor on Sill Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 II Inst 149 1.6,01' Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other: See INST 14911.6 for Design Pressure Ratings,any FL14911 R7 AE Eval 14911.6.ndf additional use limitations,installation instructions and Created by Independent Third Party: Yes tic ars. 14911.7 g. S 2900/4900-M 2902/4902 Twin-Single Hung Continuous Head and Sill Extruded Vinyl Window-Flange with Strap Anchor on Sill Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R7 II INST 14911.7.udf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:This Product is No Longer Offered by Silverline FLi4911.__R7 AE EVIL 14911.7•udf Building Products,Corporation(See 14911.7-2010 FBC Created by Independent Third Party: Yes version for Historical Documents regarding this Approval) 14911.8 h.S 2900/4900-M 2903/4903 Triple-Single Hung Continuous Head and Sill Extruded Vinyl Window-Flange with Strap Anchor on Sill Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R7 11 INST 14911.8.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports j Other:This Product is No Longer Offered by Silverline FL14911 R7 AE EVAL 14911.8.odf Building Products,Corporation(See 14911.8-2010 FBC Created by Independent Third Party: Yes version for Historical Documents regarding this Approval) 14911.9 i. Series 2900/4900 Models Extruded Vinyl Single Hung Window 2901/4901 "Weather Stopper" Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 II Inst 1491L9.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 14911.9 for Design Pressure Ratings,any FL14911_R7 AE Eval14911^9_pdf additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. (Note-See 14911.25 for Wind Zone 4 and HVHZ Impact Product) 14911.10 j.Series 2000/Model 2001 Extruded Vinyl Single Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R7 II Inst 14911.10.ndf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.10 for Design Pressure Ratings, FL14911 R7 AE Eval 14911.10.1)df any additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 14911.11 k.Series 2000/Model 2002 Extruded Vinyl Twin Single Hung Window(Continuous Head and Sill with Integral Mullion) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R7 II Inst 14911.11.01' Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 j Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.11 for Design Pressure Ratings, FL14911 R7 AE Eval 14911.11.odf any additional use limitations, Installation instructions and Created by Independent Third Party: Yes product particulars. 14911.12 I. Series 2000/Model 2003 Extruded Vinyl Triple Single Hung Window(Continuous Head and Sill with Integral Mullion) Limits of Use Installation Instructions Approved for use in HVHZ:No FLI.4911 R'7 II Inst 14911.17..odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.12 for Design Pressure Ratings, FL1491.1.,..R7 ISE Ev_il1_14911.12..pdf any additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. https:Hfloridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquZRj59%2fDrx21bt... 3/22/2016 Florida Building Code Online Page 4 of 5 i 14911.13 m. Series 2100/Model 2111 Extruded Vinyl Single Hung Window-Flange Limits of Use Installation Instructions Approved for use in HVHZ:Na FL14911 R7 Il Inst 14911,13,pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.13 for Design Pressure Ratings, FL1.49LI R7 AE Eval_14911__13.odf any additional use limitations, Installation instructions and Created by Independent Third Party: Yes product particulars. 14911.14 n. Series 2200/2300-Model Extruded Vinyl Single Hung Window-Nailing Fin 2201/2301 Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R7 II_Inst 14911.14,pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.14 for Design Pressure Ratings, FL14911 R7 AE Eval 14911.14.pdf any additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14911.15 o. Series 2200/2300-Model Extruded Vinyl Twin Single Hung Window-Nailing Fin 12202/2302 (Continuous Head and Sill with Integral Mullion) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R7 II Inst 1.491.1.15.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.15 for Design Pressure Ratings, FL1491.1 R7 AE Eva[ 14911.15.1)df any additional use limitations,Installation instructions and Created by Independent Third Party: Yes product particulars. i 14911.16 p.Series 2200/2300-Model Extruded Vinyl Triple Single Hung Window-Nailing Fin 2203/2303 (Continuous Head and Sill with Integral Mullion) Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 11 Inst 14911.16.0f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.16 for Design Pressure Ratings, FL14911 R7 AE Eval 14911.16.1)df any additional use limitations,Installation instructions and Created by Independent Third Party: Yes product particulars. 14911.17 q. Series 2907 Model 2907 Single Hung Extruded Vinyl Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 11 Inst 1,1911.17.01' Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.17 for Design Pressure Ratings, FL14911 R7 AE Eval 14911.17.pdf any additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14911.18 r. Series 2907 Model 2907TW Twin-Continuous Head&Sill Single Hung Extruded Vinyl Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R7 II Inst 14911.18.udf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.18 for Design Pressure Ratings, FI-14911 R'7 AE Eval 14911.18.pdf any additional use limitations, Installation instructions and Created by Independent Third Party: Yes i product particulars. 14911.19 s.Series 2907 Model 2907TR Triple-Continuous Head&Sill Single Hung Extruded Vinyl Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R7 II Inst 14911.19.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 14911.19 for Design Pressure Ratings, FL14911 R7 AE Eval 1491.1. 1.9.pcif any additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 14911.20 t.Series 70 Model 2127 Extruded Vinyl Single Hung Window-Nailing Fin https:Hfloridabuilding.org/pr/pr app_ dtl.aspx?param=wGEVXQwtDquZRj59%2fDrx2lbt... 3/22/2016 Florida Building Code Online Page 5 of 5 Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL14911 R7 11 Inst 14911.20.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.20 for Design Pressure Ratings, FL14911 R7 AE Eval 14911.20.Ddf any additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. Go to Page Page 1/20 Back Next j Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an WEED employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: acc:urihvaa e'n(u:r we-...a... .... 3 https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquZRj 59%2fDrx21 bt... 3/22/2016 R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 i Certificate of Independence RW Building Consultants and Lyndon F. Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named in the accompanying Florida Product Approval. Lyndon F. Schmidt, P.E. FL No.43409 April 1,2015 i i R:\Admin Docs\FBC Templates\Certificate of Independence.doc Sheet I of 1 R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 April 1,2015 To Whom It May Concern: FL-14911 Equivalency of Standards ASTM D 635-96 Equivalent to ASTM D 635-06 The products referenced in this Product Approval have been tested in accordance with ASTM D 635-96. It has been determined by Lyndon F. Schmidt,P.E.and RW Building Consultants,Inc.that ASTM D 635-96 is equivalent to ASTM D 635-06,which is the reference standard and year that has been adopted by the 5'h Edition (2014) Florida Building Code. ASTM D 638-96 Equivalent to ASTM D 638-03 The products referenced in this Product Approval have been tested in accordance with ASTM D 638-96. It has been determined by Lyndon F. Schmidt, P.E.and RW Building Consultants,Inc.that ASTM D 638-96 is equivalent to ASTM D 638-03,which is the reference standard and year that has been adopted by the 5°i Edition (2014) Florida Building Code. ASTM D 2843-93 Equivalent to ASTM D 2843-99 The products referenced in this Product Approval have been tested in accordance with ASTM D 2843-93. It has been determined by Lyndon F. Schmidt,P.E.and RW Building Consultants,Inc.that ASTM D 2843-93 is equivalent to ASTM D 2843-99,which is the reference standard and year that has been adopted by the 5'h Edition(2014) Florida Building Code. ASTM G 26-95 Equivalent to ASTM G 155-05a The products referenced in this Product Approval have been tested in accordance with ASTM G 26-95. It has been determined by Lyndon F. Schmidt,P.E.and RW Building Consultants,Inc.that ASTM G 26-95 is equivalent to ASTM G 155-05a,which is the reference standard and year that has been adopted by the 51h Edition(2014) Florida Building Code. Lyndon F. Schmidt, P.E. FL No. 43409 r' a CA No. 9813 -s P s Silvefflne p aN byMdersen o= W h m a d WINDOWS - DOD S zom o: .E 52.0"MAX.OVERALL m p •z°S FRAME WIDTH o SRt op LL n` moa V c SERIES 2900 / 4900 - MODEL 2901 / 49010 WEATHER STOPPER EXTRUDED VINYL SINGLE HUNG !E Z� WINDOW 3 "z o W � � Z o� "IMPACT' �Z a GENERAL NOTES > 1. This product has been evaluated and is in compliance with the 2010 Florida Building Code(FBC) N y structural requirements including the"High Velocity Hurricane Zone"(HVHZ). o o g X ¢ a 2. Product anchors shall be as fisted and spaced as shown on details.Anchor embedment to base a a material shall be beyond wall dressing or stucco. m 3. When used in the"HVHZ'this product complies with section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas outside of the"HVHZ'requiring wind bome debris protection this product complies m with Section 1609.1.2 of the FBC and does not require an impact resistant covering.This product meets o missile level"W and includes Wind Zone 4 as defined in ASTM El 996. rn g 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 3 6. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect, Uj m 7. This product meets water infiltration requirements for"HVHZ'. o COVERALL MAXDESIG GLASS-- ' N PRESSURE• 0 PS ! 0 TABLE OF CONTENTS FRAM ; .LO. f Z p E D SHEET A DESCRIPTION TYpEv B CIMENSION' DIMENSION POSITIVE'; NEGATIVE ; DATE: 3/4/14 z 1 Typical elevation,design pressures&general notes o saLE N.T.S. 2 Horizontal&vertical cross sections 3 Horizontal&vertical cross sections 52.00"x 73.00" 47.0"x 33.25" G1 +50,0 -50,0 DwD.er: JK m ar: LFS 3 4 Buck&frame anchoring CHK. � 5 Components DPAWND NO.: 6 Bill of materials,glazing details&components FL-14911.25 n 'o SHEET--L OF 6 d RVA-Projects\Project Folders\Proj 1601-1700\PF 1627\D.RWBC Drawings\FL-149112013 REV\FL-14911.24-25.dwg,92 ma ?z e4.' m a d v ^'•-' T X a O O 0 I I W W W N O n A 00 _ OV O O D O m 3 rP n m o S O CD O z c� CL A CDD 0) N N C V � �N C"— O 7 f) W Qm m� m A A n N N 1 4. IJ P o0 0 � D , r < Go n A o00 W O e 4 Q P Da h T O n � w Z 4 n O In .N.. n 1-1/4•MIN. v EMB,TYP. O 1-1/4"MIN. A EMB.TYP. '^ $ n PRODUCT: Daeumenta Prepared By: ' SILVERLINE@ //BUILDING CONSULTANTS, INC. I n SINGLE HUNG WINDOW /f/P.O. Ba.230 Valrica FL. 33595 IN zo Phone No.: 013.859.9197 !0 ? PART OR ASSEMBLY: Florida Board of Professional Engineers � 7-1� Certilicote Of�thod�zati n No.9813 10, 1 NANO DATE BY HORIZONTAL AND VERTICAL �3 REVISIONS CROSS SECTIONS Lyndon . hmidl, P.E. No. 409 0 2014 R.W.BUILDING CCNBULTANTS INC. E A C aaz a 9 >.; 9 H 20 10 6t ° EZ $ 5 pOe INTERIOR A g 4 s.. 6 C G v' EXTERIOR Q 0 EXTERIOR INTERIOR g z 0 1-114"MIN. Gl � EMB.TYP. GI z a i HORIZONTAL CROSS SECTION (��VERTIGAL CROSS SECTION d 3 Shown w/IXsub-buck 3 Shown w/TXsub-buck � o = p N AoV a a o EXTERIOR GI INTERIOR EXTERIOR Gi INTERIOR n Cn S20 6 0 Q 5 a 0 m 0 4 4 f 3414 .o E zc sMa N.T.S. 73 3 Brro.Bn JK m W 4 VERTICAL CROSS SECTION aft By, LIS 3 NO-3 VERTICAL CROSS SECTION 3 Optional masonry sill MAXIM Optional masonry sics l FL-14911.25 0 a s= �La-_�L a 4" P.r 10.75"(TYP.) o n Q Fl \n UI c O .IZ P. D 2X BUCK G C m Z m o LL `0 9 :o 2X BUCK — 1X BUCK J — BUCK .o r TYP. HEAD E 4 3 FRAME z w w— MASONRY OPENING MASONRY _ 2X BUCK F ¢ �� m �_ OPENING = w Y U N 1X BUCK H DO N o a TYP. o v _ JAMBS a a ry ► 1 Ln BUCK ANCHORING FRAME ANCHORING z MASONRY 2X BUCK .3 0 V 3 CONCRETE ANCHOR NOTES: a z 0 1.Concreteanchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. w a 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to o maintain the min.edge distance to mortarjoints,additional concrete anchorsT = may be required to ensure the"MAX.ON CENTER"dimensions are not exceeded, 0 0 3.Concrete anchor table: Z a ANCHOR NGHOR AKIN .MIN CLEARANCE MIN CLEARANCE: DAZE 3/4/14 0 MASONRY i0 ADJACENL scaLE: N.T.S. d TYPE S►IE. EMBEDMENT r ......EDGE:... ........ANCHOR:.':.; Dwc.aY: JK m ITWCNK.eY: LFS 3 TAPCON® 1/4" 1-1/4" 2.1/2" 4" DAAMNO NO.: V ELCO 1/4" 1.1/4" V, 4" FL-14911.25 ULTRACON® o M N L SHEEP 4 OF 6 o P-AA-ProjectskProject FoldemkPiol 1601-17001PF 162716.RWBC Dravvinqs\FL-mil 2013 REVVL-1491124-2$,dg,9.5 � -64- 2.96, 7 DL 0 j a. 0.065*— .07, o err -s Aa .06" or 3 22' 2ZG PRODUCT: S(LVERUNE ��pp BUILDING CONSULTANTS, INC. SINGLE HUNG WINDOW C o PART OR ASSEMBLY: n-ld. B—d W P10—i...I E.gi—r. !n TE C-liftt.Of 9813 Ro, DATE —— I BY COMPONENTS 21314 R.W.S­Dlmo CommuLTA—INC. REVISIONS Lyd.n F.Schmidt, RE. !,12a Or ol BILL OF MATERIALS ITEM DESCRIPTION MATERIAL B 2X BUCK SG>=0.55 WOOD C 11W MAX.SHIM SPACE D 114'X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 4 =M MASONRY-3000 PSI MIN.CONCRETE CONFORMING TO ACI a 2 E 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE > o a F #10 X 7'PFH SMS STEEL o m .'I G #10 X 2-3/4"PPH SMS STEEL g u a•;a$ i H 1/4"X 3-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL m Zmm o' 0 J 114'X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL g 9 o L o 1 EXTRUDED VINYL PVC WINDOW HEADER#2902VINYL a m o 2 EXTRUDED VINYL PVC WINDOW MEETING RAIL#2907' VINYL ` `z 3 EXTRUDED VINYL PVC SASH TOP RAIL LOCK #2908' VINYL 12 c U 4 EXTRUDED VINYL PVC SILL#2903• VINYL 6 0 5 EXTRUDED VINYL PVC SASH LIFT RAIL BOTTOM #2949' VINYL 5/8"OVERALL 6 EXTRUDED VINYL PVC SASH GLAZING BEAD#2217' VINYL THK.GLASS o z u, 3 7 EXTRUDED VINYL PVC SASH INTERLOCK GLAZING BEAD#3557' VINYL 1/8"ANNEALED U �w 8 EXTRUDED VINYL PVC WINDOW FRAME GLAZING BEAD#2317' VINYL O z 9 EXTRUDED VINYL PVC JAMB#2901' VINYL AIRSPACE W 3 v a 3/37'ANNEALED z 10 EXTRUDED VINYL PVC SASH STILES#2905• VINYLc� } S o 12 INTERCEPT SPACER STEEL 0.090"SAFLEX®PVBINTERLAYER 13 DOW 995 SILICONE SILICONE 3/37-ANNEALED yw N sy 15 SUPERSPACER SPACER 20 ALUMINUM 6063-T6 SASH REINFORCEMENT BY SILVERLINE#2967 ALUMINUM ^ -o 9 LAS 21 ALUMINUM 6105-T5 INTERLOCK REINFORCEMENT BY SILVERLINE#50-2609 ALUMINUM 1/78 E 13 &Ia m N 22 ALUMINUM 6105-TS MEETING RAIL REINFORCEMENT BY SILVERUNE#50-2608 ALUMINUM a a 30 SASH LOCK BY SILVERLINE ROTO LOCK Gi GLAi1NG DETAIL m 31 KEEPER ATTACHMENT SCREW#6A x 3/4"PFH ZINC PLATED STEEL 32 #8 X 1"FLAT ZINC PLATED STEEL 35 SIDE LOCK OMEGA SHOE 36 SASH LOCK BY SILVERLINE CAM LOCK 37 KEEPER ATTACHMENT SCREW#6A x 3/4"PFH ZINC PLATED STEEL A. 38 #8 X 1"FLAT ZINC PLATED SCREW STEEL o THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY EXTRUDERS LICENSEES IN"AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". 0 .82' z .335' b d w a m Q .87ff' k o 6 .125' ^ m O � z ASS�---1 DATE: 3/4/14 z 'o 'o o SCALE N.T.S. � e REINFORCEMENT REINFORCEMENT REINFORCEMENT Owc.er: JK m 9 o 20 Jamb 8 BoBom roil 21 Top sash 22 Meeting ral CNN.BY. LFS 3 DRAWING ND.: V Q FL-1491 1.25 0 N L SHEET_L OF E � 'o g _ RW R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product EvaltiationReport i I Product Sub Category Manufacturer Product Name Category Silverline Building Products Corporation Series 2900/4900-Model 290114901 Window Single Hung 1 Silverline Dr. "Weather Stopper" North Brunswick,NJ 08902 Extruded Vinyl Single Hung Window Phone 732.435.1000 "Impact" Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc,and Lyndon F.Schmidt,P.E.(System ID# 1998)for SilverLine Building Products Corporation based on Rule Chapter No.61G20-3,Method 1d of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code(FBC)structural requirements including the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the"HVHZ"this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas outside of the"HVHZ"requiring wind borne debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM El 996 and FBC Section 1609.1.2.2. 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of drawing FL-14911.25 require further engineering analysis by a licensed engineer or registered architect. 7. This product meets the water infiltration requirements for"HVHZ'. 8. See drawing FL-14911.25 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by NCTL 110-16675-1 TAS 201,202 and 203-94 NCTL Robert H.Zeiders,P.E. NCTL 110-16675-3 AAMA/WDMA/CSA 101/I.S.21A440-08 NCTL Robert H.Zeiders,P.E. NCTL 110-16675-2 ASTM E1886-05/ASTM E1996-09 NCTL Robert H.Zeiders,P.E. Materials PVC Extrusions ETC 97-264-00910 ASTM D635-96,D1929-96, D2843-93 ETC,Laboratories J. L.Doldan,P.E. D638-96 and G26-95 2. Dade-County NOA Materials Testing 14-0423-16 Saflex®PVB Interlayer(Eastman Chemical Company) 3. Drawing No. Prepared by Signed&Sealed by No.FL-14911.25 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 4. Calculations Prepared by �.� r ri s L3Signed&Sealed by Anchoring RW Building Consultants,Inc.(CA#9813) heti. °tLyndon F.Schmidt,P.E. ASTM E1300 Glass Load Lyndon F.Schmidt,P.E. 5. Quality Assurance y Certificate of Participation issued by Window&Door Manufacturers Association,certifying that SilverLine Building Products Corporation is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. C u #Gt• ; 'd `u�" Lyndon F.Schmidt,P.E. FL PE No.43409 312712016 Sheet 1 of 1 • Florida Building Code Online Page 1 of 2 pW I � ( r ,Cra 9t �_ ,�� K � 1 BCIS Home Log In User Registration Hot Topics Submit Surcharge Slats&Facts Publications FBC Staff BCIS Site Map I Links Search Business° ' � has Product Approval Professional + _ USER:Public User R,eia tori , : }- { ® Product Approval Menu>Product or Aoolication Search>Agolication List>Application Detail>Application Checklist �''� � Form Title: Validation checklist for evaluation report from an architect or engineer Form#: 9N-3.011(3)(c) Administrative Validation ,-'/1 1. Verify the evaluator is a Florida Registered Architect or Florida Professional Engineer who has taken the core building code course. E4,j 2. Verify submission of the evaluator's certification of independence. 3. If the evaluation is not performed by a third party independent of the manufacturer then verify validator's certificate of independence. 914. Verify the evaluation report is for the products listed on the application as described on the application and that the products are within the scope of Rule 9B-72. 5. Verify that test reports demonstrating compliance were performed at a test lab accredited by an approved accreditation body for the test performed,and verify test lab location. 1 f 6. Verify that the test reports or rational analysis are required by the Building Code as a component of a product approval for the product category and subcategory. .7i 7. Verify that rational analysis demonstrating performance were executed utilizing current code requirements and was not used in lieu of a standardized test required by the Code or that rational analysis was not required. v'8. Verify that all data,test reports and calculations,are substantiated on the report. -!'9. Verify that the application has the Code sections and reference standards for which the evaluation demonstrates compliance. ✓;10. Verify the method of demonstrating compliance indicate any limitations on the use of the product,as intended. 11. Verify the manufacturer installation instructions are in accordance with the evaluation report,and attachments are provided. L;;,}12. Verify that a quality assurance program audited by a Florida Building Commission approved third party quality assurance agency is in place. ;.�i To the best of my/our knowledge,this application is complete,the items in the checklist above have been verified and reviewed,and the evaluation report submitted with this application indicates that the product, method,or system described in this application meets or exceeds the Florida Building Code requirements and reference standards listed in the application. 1 flack Next Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an A VEEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. https:Hfloridabuilding.org/pr/pr_app_chek.aspx 3/22/2016