HomeMy WebLinkAboutProject Information Property Information y 1,11 Building Information Owner: Sullivan Wind Zone: 150 MPH. Address: 22 La Puerta del Norte Exposure Category: B Ft Pierce,Fl 34951 €' Minimum Building Dimension: 24 ft. B{ Mean Roof Height: 15 ft. k Risk Category: II u: Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative IF Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) IL1 End 53 66 7 26.9 -34.9 _....... ... _ -- 2 Int 37 66 7 27.6 30.0 _1111. _._ 3 Int 53 55 7 27.2 29.7 . ... . .. .__ . _ .. 4 End 53 55 7 27.2 35.6 ---.... .... .. . ................_._ . .......... .... _. .1....1 .1..1---- ........_. 5 Int 72 81 7 26.0 -28.4 __1111. ... . .._..... ...-1111. ._..._.__... ._....... . ......._ _1111-... ...... _._... .... 1111 _._...... ._.. -.. . _....... 6 End 74 66 7 26.3 -33.7 _. ._ ...._.. . _..... ..... . . ........ . ......... _ . ... ..._1...111... -_-. . .. _1111 7 Int 26 40 7 28.5 -31.0 ........ . ........ . I........... 1111.. . __ .. . ....._ ......_ 1_- 11.1.. .--_- 8 Int 26 40 7 28.5 31.0 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Enilding Code. Page 1 of 1