Loading...
HomeMy WebLinkAboutProduct Approval .Florida Building Code Online Page 1 of 5 4 i r - �� Florida Depaament4 BCS Home Log In ( User Registration ; Hot Topic Submit Surcharge Stats @ Facts Publications FBC Staff BCIS Site Map Links I Search Busines Product USER:Public User Regulation rZ FP ifI — Product Approval Menu>Product or Application Search>Application List>Application Detail ®^"� NAM�`� FL# FL15180-RI APR o 7 2016 Application Type Revision Code Version 2014 PERMITTING Application Status Approved S'i• Lucie County FL Comments Archived 0 Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES,CA 90045 (440)969-9773 Ext 16 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 16 ronoconnell@plastpro.com Category Exterior Doors Subcategory Swinging Exterior Door Assemtblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer C1 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J.King,P.E. W, Validation Checklist-Hardcopy Received Certificate of Independence FL1S180 R1 COI CERTIFICATE of INDEPENDENCE odf Referenced Standard and Year(of Standard) Standard year ASTM D1929 1996 ASTM D1929 2006 ASTM D2843 1999 _...^535 1.998 AST H,D638 2003 ASTM E1300 2004 AST.. 2C^— ASI i•;.��� 15�- Florida Building Code Online Page 2 of 5 TAS 201,202,203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15180 R1 Equiv Equivalency Of Standards.odf Sections from the Code Product Approval Method Method i Option D Date Submitted 04/24/2015 Date Validated 04/26/2015 Date Pending FBC Approval 04/28/2015 Date Approved 06/23/2015 Summary of Products Go to Page i6l Page 1/2 FL# Model,Number or Name Description 15180.1 a.Smooth/Wood 6'8"Impact"Glazed Fiberglass Single Door-Outswing(X- Grain/Rustic/Mahogany Series N Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.1.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.1 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.1.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.2 b.Smooth/Wood 6'8"Impact"Glazed Fiberglass Single Door with"Impact" Grain/Rustic/Mahogany Series N Sidelite-Outswing(OX or XO-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.2.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.2 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.2.1)df additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.3 c.Smooth/Wood 6'8"Impact"Glazed Fiberglass Single Door with"Impact" Grain/Rustic/Mahogany Series N Sidelites-Outswing(OXO-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.3.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.3 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.3.gdf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.4 d.Smooth/Wood 6'8"Impact"Glazed Fiberglass Double Door-Outswing()X Grain/Rustic(Mahogany Series N -Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 11 Inst 15180.4.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.4 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.4.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.5 e.Smooth/Wood 6'8"Impact"Glazed Fiberglass Double Door with"Impact" Grain/Rustic/Mahogany Series Sidelites-Outswing(0)0XO-Configuration) Fiberglass Door http://www.floridab'uilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsidcffd6ieP8HC... 4/4/2016 Florida Building Code Online Page 3 of 5 Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.5.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.5 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.5.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.6 f.Smooth/Wood Grain Series N 8'0"Impact"Glazed Fiberglass Single Door-Outswing(X- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 1S180.6.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.6 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.6.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.7 g.Smooth/Wood Grain Series N 8'0"Impact"Glazed Fiberglass Single Door with"Impact" Fiberglass Door Sidelite-Outswing(OX or XO-Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.7.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.7 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.7.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.8 h.Smooth/Wood Grain Series N 8'0"Impact"Glazed Fiberglass Single Door with"Impact" Fiberglass Door Sidelites-Outswing(OXO-Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.8.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.8 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.8.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.9 i.Smooth/Wood Grain Series N 8'0"Impact"Glazed Fiberglass Double Door-Outswing(XX Fiberglass Door -Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.9.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.9 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.9.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.10 j.Smooth/Wood Grain Series N 8'0"Impact"Glazed Fiberglass Double Door with"Impact" Fiberglass Door Sidelites-Outswing(OXXO-Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.10.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.10 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.10.Ddf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.11 k.Smooth/Wood 6'8"Impact"Opaque Fiberglass Single Door- Grain/Rustic/Mahogany Series N Inswing/Outswing(X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.11.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.11 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.11.odf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.12 [Grain Smooth/Wood 6'8"Impact"Opaque Fiberglass Single Door with"Impact" GS /R Series N Sidelite-Outswing(OX or XO-Configuration) iberglass Door http://www.floridabuilding.org/pr/pr appdtl.aspx?param=wGEVXQwtDgsidcHd6ieP8HC... 4/4/2016 Florida Building Code Online Page 4 of 5 Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.12.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.12 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.12.odf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.13 m.Smooth/Wood 6'8"Impact"Opaque Fiberglass Single Door with"Impact" Grain/Rustic/Mahogany Series N Sidelites-Outswing(OXO-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.13.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.13 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.13.1)df any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.14 n.Smooth/Wood 6'8"Impact"Opaque Fiberglass Double Door- Grain/Rustic/Mahogany Series N Inswing/Outswing(XX-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.14.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.14 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.14.odf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.15 o.Smooth/Wood 6'8"Impact"Opaque Fiberglass Double Door with"Impact" Grein/Rustic/Mahogany Series N Sidelites-Outswing(OXXO-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.15.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INSf 15180.15 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.15.odf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.16 p.Smooth/Wood Grain Series N 8'0"Impact"Opaque Fiberglass Single Door- Fiberglass Door Inswing/Outswing(X-Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.16.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other.See INST 15180.16 for Design Pressure Ratings, FL1S180 R1 AE Eval 15180.16.1)df any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.17 q.Smooth/Wood Grain Series N 8'0"Impact"Opaque Fiberglass Single Door with"Impact" Fiberglass Door Sidelite-Outswing(OX or XO-Configurations) Limits of Use Installation Instructions Approved.for use in HVHZ:Yes FL15180 R1 II Inst 15180.17.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INSf 15180.17 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.17.odf any additional use limitations,installation instructions and Created.by Independent Third Party:Yes product particulars. ,-A ]� 15180.18 r.Smooth/Wood Grain Series N 8'0"Impact"Opaque Fiberglass Single Door with Sidelites- �\ Fiberglass Door Outswing(OXO-Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180 18 odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.18 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.18.odf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsidcHd6ieP8HC... 4/4/2016 Florida Building Code Online Page 5 of 5 15180.19 s.Smooth/Wood Grain Series N 80"Impact"Opaque Fiberglass Double Door- Fiberglass Door Inswing/Outswing()X-Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.19.Ddf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.19 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.19.Ddf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15180.20 t.Smooth/Wood Grain Series N 8'0"Impact"Opaque Fiberglass Double Door with"Impact" Fiberglass Door Sidelites-Outswing(OXXO-Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL1S180 R1 II Inst 15180.20.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15180.20 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.20.Ddf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. Go to Page 40 0 Page 1/24 0 Back Next Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However emailaddressesare public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click ham. Product Approval Accepts: ¢Che_k sccurity.%u:nkres http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwd)gsidcHd6ieP8HC... 4/4/2016 R ` R W Building Consultants, Inc. WB B Consulting and Engineering Services I'or the Building Industry C P,O.Box 230 Valrico;FL 33595 Phone 813.659,9197 Florida Board of Professional Engigeers Ceriificate ofAulhoriaation No.9813 Product Evaluation Report ReportNo.: FL-15180.18 Date: —April 23, 2015 Product Category Sub Category Manufacturer Product Name Swinging Plastpro Inc. Smooth/Wood Grain Exterior Exterior Door 5200 W.Century Blvd. Series N Fiberglass Door Doors LOS Angeles,CA Outswing Assemblies g Phone 440.969.9773 "Impact" Scope: Product.Evaluation report issued by R W Building Consultants,Inc.&Lyndon F.Schmidt,P.E.(System ID#1898)for Plastpro Inc.,based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon.F,Schmidt, P.E.do not have nor will acquire financial,interest in the company manufacturing or distributing the product in any other entity involved in the approval process of the product named Limitations: 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code(FBC)structural requirements including the"High Velocity Hurricane Zone". 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the"HVHZ"this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas outside of the"HVHZ"requiring wind borne debris protection this product complies with Section 1609.1.2 of the FBC and does not require,an impact resistant covering.This product meets missile level"D"and includes Wind Zone.4 as defined in ASTM E 1.996 and Section 1609.1.2:2 of the FBC. 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditionsthat deviate from the details of drawing FL-15180.18 require further engineering analysis by a licensed engineer or registered architect. 7. Thisproduct meets water infiltration;requirements for"HVHZ'. 8. See drawing FL-15180.18 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 07-01030198 TAS 201,202,203-94 Testing Evaluation Lab.,lnc. Wendell Haney,P.E. CTLA 924W&024W-1 TAS 201;202,203-94 Certified Tesing Laboratories Ramesh Patel, P.E. ETC 07-209-19303.0 ASTM D2843-99,ASTM D635-98 ETC Laboratories Ben Meunier ASTM D1929-96,ASTM D638-03 ETC 08-209-20609.0 ASTM D2843-99,ASTM D635-98 ETC Laboratories Gurjinder Dhami ASTM D1929-96,ASTM D638-03 ETC 06-255-17412.0 ASTM E84-05 ETC Laboratories Joe Doldan,P.E. ETC 05-255-16776.0 ASTM G26-95,D2843-99,.D635-98, ETC Laboratories Joe Doldan,P.E. D 1929-06; D638-03 2. Miami-Dade NOA Materials Testing 10-1209.01 HP Polypropylene 14-0423.16 Saflex PVB Interlayer(Eastman Chemical Co.) 3. Drawing No. Prepared by Signed&Sealed by No.FL-15180.18 RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt,P.E. 4. Calculations Prepared byra.� � Signed&Sealed by Anchoring RW Building Consultants,Inc.(CA#9813) "E I -a RFs& Lyndon F.Schmidt,P.E. ASTM E1300 Glass Load Lyndon F.Schmidt,P.E. o , , ^°' t� 'U ° GCn 5. Quality Assurance °°`° '°°r "ate Certificate of Participation issued by National Accreditation and Management Institute,certifying that Plastpro Inc.is manufacturing products - _ m within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. Lyndon F.Schmidt,P.E. FL PE No.43409 4/24/2015 Sheet 1 of 1 ' , plastpro ° - N xf J=U M7 5200 W. CENTURY BLVD. =V * E 2 g LOS ANGELES, CA 90045 N,y z Smooth / Wood Grain �� J' Series N Fiberglass Door -? � e m ° h e.q 9oLa 12OUTS WING a 115.W MAx.OVEMLL FRAMEwIDTH , , m a a "IMPACT" ¢ c o6 o �d yy Do z L GENERAL NOTESz ci o o- 1. This product has been evaluated and is In compliance with the 5th Edition(2014)Florida Building Code 5 (FBC)structural requirements including the"High Velocity Hurricane Zone"(HVHZ). I? fL LL 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base materialo D- Shallbe beyond wall dressing or stucco. O O o DO w 3. When used in the"HVHT'this product complies with Section 1626 of the Florida Building Code and does not a a a require an impact resistant covering. 9u—]� U LL 4. When used in areas outside of the'11VHP'requiring wind borne debris protection this product complies with p O Section 1609.1.2 of the FBC and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E1996 and Section 1609.1.2.2 of the FBC. c b a 5 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck a y z masonry construction. W o rn 6. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. ° 7. This product meets water infiltration requirements for"HVHZ". a TABLE OF CONTENTS a SHEET# DESCRIMON N a a1 Typical elevation,design pressures,8 general notes 2 Door panel details 3 Sidelite panel details and glazing detail ^Z u a 4 Horizontal cross sections Dore:02121112 i 5 Vertical cross sections OVERALL, DESIGN PRESSURE PS SCALE: N.T.S. 6 Vertical cross sections -SWING fRAME MO.BY: JK m e 7 Buck anchor ng QIMENSION POSITIVE NEGATNE CHK.BY: LFS 3 _. 8 From anchoring OUTSWING 115.00"x 96.50" +50.0 -50.0 ORAWINO NO.: N 9 Bill of materials and components FL-15180.18 0 SHEV OF 9 N a P-4%lientsWasipm,Inc PERMANE Florida Product A royal FL-15180 C-DraMn s Curren FL-15180.11-20.dw 8-2 9525 MAX.DOOR PANG.HEIGHT -{ _ a $ ® ® o S � P-3o:t o O v NN go � -D �!9 , 0Zzi Z ° E5 7< •`o'z D m N N � >R 2 A 7=O O P [+fin O D M m M O 0 A A. A.N EW!LR z O n N Ul �j 0.075' / m O 00 1 CA I 0.020" I z ;7�: p Z. A > 0 F= F= \ _ a 0 1. n mS m I m O Gc7Z O 00 v� nJO �O N Q Z m m m 1r m 1.13" 0 z %%"%%J11111111" a No.43409 yZAl-r Ai n S PRODUCT: Documents Prepared By:�, •• `� rA2oR]D►.r' �� Lyndon F. Schmidt IN I z N PLASTPRO INC. P.E. No. 43409 in G Z ro FIBERGLASS DOOR rn 0 ca r ti PART OR ASSEMBLY: /1C��/BUILDING CONSULTANTS, INC. IfD P in 1 04/22 15 UPDATE TO 5TH ED. (2014) FBC JK DOOR PANEL DETAILS JI�YY P•0. Box 230. ValHco, FL 33595 m ro NO DATE BY Phone No.: 813.859.9197 REVISIONS FBPE CA No. 9813 ®2012 R.W.BUILDING CDNBUI-NTB INC. 1 ill � ` ....... 1 2 12 .�� 5 5 6 6 1-1/4'MIN. ar EXTERIOR NOTE g gyp).) o 60 E �vl 1.SIDELRE PANELS ANCHORED TO FRAME 6" ° . ,y;, z FROM TOP OF FRAME THEN 14"MAX.ON �� 89 .. ° ��/ �•••, `�� e CENTER,8 SCREWS TOTAL EACH JAMB. v //i///� •* �, z d;o Faun n� 8 Z • t� i uZV ��J, h Em m°cm 0 IL 4 4 INTERIOR v 0 z 8 v Lj 1 (� 21 20 o y 60 0U- C Cv K c) m o� Y am 3 q 3 4 4 HORIZONTAL CROSS SECTION U 0 5 5 6 6 4 shown w/1X sub-buck o F ti a a LL EMB.(TYP•) EXTERIOR 27 40 40 9 88 a, 60 88 Ni 11 K e p 89 EXTERIOR 89 t0 60 0 0 0 89 `" z > p � Q° a d b INTERIOR 60 7 INTERIOR • • 20 8 7 20 21 N J ° 20 21 21 20 21 DATE:02121112�.15'IvllN. .1S'MIN.� 12 �.1S'MIN. scAtE: N.T.S. C-SINK C-SINK C-SINK 21 20 12 DWG.ar: JK m C 15'MIN. .15'MIN. 5 <v B C-SINK C-SINK cHK.BY. LFS 3 e / DaAwwc m: 1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION 3 HORIZOMAL CROSS SEC110N N E 4 4 4 FL-15180.18 0 SHEEP_�L OF B B d • R�Cljents\ptaMm,Inc PERMANE Florida Product ls\FL-16 Mc-Orawin LurrentifL-15180.11-20.dw 8-S Q v o, o m m p n 1? v a..g, s z A Q a a � 4 C2 r .oVv vv p. b.. 1-114 MN. tf1 EMB.(M.) 1-114, N. EMB.(TYP.) 1-114 MIN. EMB.(TYP.) rn m g cn N ,_ fl m wA 5< g A X t— r v VO tr Q 1S'in n tq v N Z CD M V OD ;;0 .: v n . a G v d = 1-1/4" IN. EMB. N.43409 $ PRODUCT: 0ocume111a Prrpar+d 9Y•�, � .RORCO..'•.': ���• on N FIBERGIASRS DOOR P/E�aND�434a9tdt /''q�� �t, ``. Z N_ PART OR ASSEMBLY: /r BUILDING CONSULTANTS. INC. (�' 0' '(1~j i 2 15 UPDATE TO 57H EO. (2074)F8C JK VERTICAL CROSS SECTIONS Phone No.:e/li P.O. Box 2301 .659.9VaIrloo7 33595 D m N NO DATE BY FSPE CJL NO. 98539197 REVISIONS 0 2012 R.W.BuILDI-0 U—Su---INC. ��A%.• •Q_ii N 77$x$xVyy .-`YY � E E '� �'• �` a m'm D a J •p U N OD Z° LI � gxz o`o a A C Z mda� m � 4 o= 20 2160 20 21 a 60 89 SEE NOTE 189 L o SEE NO 1 INTERIOR o z U z _F EXTERIOR o ¢� EXTERIOR INTERIOR n 1 VEIMCAL CROSS SECTION 2 VERTICAL CROSS SECflON 6 6 Shown w/iX sub-buck a U C, N OO a a �a}0 INTERIOR it60 V SEE NOTE 1 69 v^ SEE NOTE 1 89 EXTERIOR EXTERIOR INTERIOR 20 21yo z Ln V W 0 za 29 pi E E $ e•' e N Q j • e° O Z Z O DATE:02121112 ? N.T.S. ° NOTE 4 VERTICAL CROSS SECTION DWG.BY: K m S VERTICAL CROSS SECTION_ 1.SIDELITE PANELS ANCHORED TO FRAME 6" 6 CHK.BY: LFS 3 6 FROM EACH END AND AT CENTERLINE. DRAP7Nc NO, x N s FL-15180.18 0 SHEET 8 OF 9 N O d 4 8. 4,. 4,. •A z Q;.'O� o rn • I I I I �• ••.•....•.• .�' o m o.ai° z U N . I TYP.HEAD ` \� = o z II II &JAMBS \` ' 8m 9m`oa II II oZ I II o I 2X REINFORCEMENT SHOWN I Ia FOR REF.ONLY 2X BUCK I I I I II II �g Z II II cc II II �d a hchc W II II a�� 0 II II 6 MASONRY II II a a OPENING I I I I rm II II II II � II II in s BUCK ANCHORING CONCRETE ANCHOR NOTES: 1.Conaefe anchor locations at the comers maybe adjusted to maintain the min. sedge distance to mortarjolnts. N UJ a 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to N= �+ '9 malntaln the min.edge distance to mortar joints,additional concrete anchors g m may be requUed to ensure the'MAX.ON CENTER"dimenslon are not exceeded. —z u 3.Concrete anchor table: a DATE.-02/21 12 i ANG1i01! MiN MtN C1EAIIANGE .....ICiEARANCF AIf10R TC+INASONRY TOALTJkCENf i t1'PE 1AM11BUM1NT... : ;:`_EQGE /AMGHI3R;:':;::;: DWG.BY. N JK m i............:......... .... . ... A 1TW CHK.BY. LFS 3 E TAPCON® 1 4" 1.1/4' Y 4° Drumm r+o.: s ELCO ® FL-15180.18 "- w ULTRACON 1/4" 1.1/4" 1° 4" 0 SHEEP 7 OF g d d it In A -_M cdm :k Top) —.-I to° 4" o n°0 el zo �1 8 in 9 w in maa� li Oz TYP.HEAD IL _ — — — TYP.HEAD 8 I aJAMBS JAMBS MASONRY MASONRY 28 OPENING — U WWOPENING O QO Z(7 �O FRAME _ _ — — — x= FRAME o z j 1XBUCK �2XBUCK12 H TYP.®SILL p — TYP.®JAMB — TYP.®SILL TO REINFORCEMENT 17, � o 1 1 I t i'•. 1 I 1 I a SEE HINGE d" DETAIL SnUKE JAMB FRAME ANCHORING HINGE JAMB FRAME ANCHORING 3 Masonry 2X buck construction Masonry TX buck construction Sz a L N o Z N K a CONCRETEANCHOR NOTES: 9 a u 1.Concrete anchor locatlons at the corners may be adjusted to maintain the Mn. 2$ K edge distance to mortar jolnfs. -Concrete anchor locations noted as'MAX ON CENTER"must be adjusted to M 10 maintain the mhl.edge dhtance to mortarjolft additional concrete anchors ALI'maybe requeMired to ensure thAX.ON CENTER"dimenslon are not exceeded.3.Concrete anchor table: TKRF 3f7 EMBELIMENT TG MASONRY, 1DADIACEtVf LATCH&DEADBOLTDEfWL HINGE DETAIL DATE 02 21 12 scay. N.T.S. rtW e A 4• JK 1/ 1.1/4" Y 4" DWG.BY: TPCON 2 ELCO i/4' 1.1/4" 1" 4" CHK.BY: LFS ULTRACON DRAWING NO.: WOOD SCREW INSTALLATION NOTES: $ 1.Maintain a mfnlmum 5/8'edge distance,I"end distance.8 1"o.c.spacing of FL-15180.18 ov wood screws to prevent the spNfing of w ood. sHEEr 8 9 D d �' D 4.56"—.•� ��Q��•• �� a BILL OF MATERIALS I at`i Li ITEM I DESCRIPTION MATERIAL V' * z` A I X BUCK SG>=0.55 WOOD = g 0' B 2X BUCK SG>=0.55 WOOD �i� Q� z N C 1/4"MAX.SHIM SPACE _ '�,� •'••• .-•• �:` i n a D 114'X 2-3/4"ELCO OR ITW CONCRETE SCREW STEEL �! 2 36°��27 '4���� � ul o U N' MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI e E CONCRETE 20 E D b IDE 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 Jamb E m =A o H 1/4'x 3-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL a g N 9 q I IXX 2-1/4"PFH ELCO OR TTW CONCRETE SCREW STEEL 4.56"�{ ^ ¢ m a a JINX 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL I E z° K #9 X 2-1/7'PFH WOOD SCREW STEEL Jia L #8 X 2-1/7'PFH WOOD SCREW STEEL M #8 X 7'PFH WOOD SCREW STEEL 7 FORCE 5 WEATHERSTRIPPING BY ENDURA FOAM 8 COMPRESSION WEATHERSTRIP QLON 650 BY SCHLEGEL FOAM I� 2.44" 2.13" J y 9 4'X 4"BUTT HINGE STEEL z o c 10 #9 X 1"PFH WOOD SCREW STEEL 21 pEADDftl IDE N as 11 #9 X 3/4PFH WOOD SCREW STEEL °N "' 20 FINGER JOINTED PINE FRAME,HEAD&HINGE JAMBS WOOD o� y 21 POLY FIBER JAMB COMP./VINYL a -Z d 27 LATCH STRIKE PLATE STEEL o m N 28 DEADBOLT STRIKE PLATE STEEL o O 29 OUTSWING THRESHOLD BY DLP ALUM./WOOD a 4S6" 31 OUTSWING BUMP THRESHOLD ALUM. 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 2.03" 'm LL 60 SIDELITE PANEL-SEE SIDELITE PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 88 2X REINFORCEMENT(CLEAR PINE)SG>=0.49 WOOD Lo 89 #7 X 2"PFH DRYWALL SCREW STEEL 8cn V OUfSW►NG THRESHOLD BY DLP g U) 468" ro tr = 8 w n p J }T o m O Z a 31 OUISWING BUMP THRESHOLD Dae:02121112 i sc"+ N.T.S. 9 a On.BY: JK m' 5 2 CHK.eY: LFS 3 DR1WM0 NO: S FL-15180.18 0 SHEET B OF 9 0 a r � < r