HomeMy WebLinkAboutProduct Approval .Florida Building Code Online Page 1 of 5
4
i r
-
��
Florida Depaament4 BCS Home Log In ( User Registration ; Hot Topic Submit Surcharge Stats @ Facts Publications FBC Staff BCIS Site Map Links I Search
Busines
Product USER:Public User
Regulation rZ FP ifI —
Product Approval Menu>Product or Application Search>Application List>Application Detail ®^"�
NAM�`� FL# FL15180-RI APR o 7 2016
Application Type Revision
Code Version 2014
PERMITTING
Application Status Approved S'i• Lucie County FL
Comments
Archived 0
Product Manufacturer Plastpro Inc./Nanya Plastics Corp.
Address/Phone/Email 5200 W CENTURY BLVD.
LOS ANGELES,CA 90045
(440)969-9773 Ext 16
rickw@rwbldgconsultants.com
Authorized Signature Vivian Wright
rickw@rwbidgconsultants.com
Technical Representative Scott Johnson
Address/Phone/Email 5200 W Century Blvd.
Los Angeles,CA 90045
(440)969-9773 Ext 18
scottjohnson@plastproinc.com
Quality Assurance Representative Ron O'Connell
Address/Phone/Email 5200 W Century Blvd.
Los Angeles,CA 90045
(440)969-9773 Ext 16
ronoconnell@plastpro.com
Category Exterior Doors
Subcategory Swinging Exterior Door Assemtblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
C1 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E.
the Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Ryan J.King,P.E.
W, Validation Checklist-Hardcopy Received
Certificate of Independence FL1S180 R1 COI CERTIFICATE of INDEPENDENCE odf
Referenced Standard and Year(of Standard) Standard year
ASTM D1929 1996
ASTM D1929 2006
ASTM D2843 1999
_...^535 1.998
AST H,D638 2003
ASTM E1300 2004
AST.. 2C^—
ASI i•;.��� 15�-
Florida Building Code Online Page 2 of 5
TAS 201,202,203 1994
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL15180 R1 Equiv Equivalency Of Standards.odf
Sections from the Code
Product Approval Method Method i Option D
Date Submitted 04/24/2015
Date Validated 04/26/2015
Date Pending FBC Approval 04/28/2015
Date Approved 06/23/2015
Summary of Products
Go to Page i6l Page 1/2
FL# Model,Number or Name Description
15180.1 a.Smooth/Wood 6'8"Impact"Glazed Fiberglass Single Door-Outswing(X-
Grain/Rustic/Mahogany Series N Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.1.1)df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.1 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.1.odf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.2 b.Smooth/Wood 6'8"Impact"Glazed Fiberglass Single Door with"Impact"
Grain/Rustic/Mahogany Series N Sidelite-Outswing(OX or XO-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.2.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.2 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.2.1)df
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.3 c.Smooth/Wood 6'8"Impact"Glazed Fiberglass Single Door with"Impact"
Grain/Rustic/Mahogany Series N Sidelites-Outswing(OXO-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.3.1)df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.3 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.3.gdf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.4 d.Smooth/Wood 6'8"Impact"Glazed Fiberglass Double Door-Outswing()X
Grain/Rustic(Mahogany Series N -Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 11 Inst 15180.4.1)df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.4 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.4.odf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.5 e.Smooth/Wood 6'8"Impact"Glazed Fiberglass Double Door with"Impact"
Grain/Rustic/Mahogany Series Sidelites-Outswing(0)0XO-Configuration)
Fiberglass Door
http://www.floridab'uilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsidcffd6ieP8HC... 4/4/2016
Florida Building Code Online Page 3 of 5
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.5.1)df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.5 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.5.odf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.6 f.Smooth/Wood Grain Series N 8'0"Impact"Glazed Fiberglass Single Door-Outswing(X-
Fiberglass Door Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 1S180.6.1)df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.6 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.6.odf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.7 g.Smooth/Wood Grain Series N 8'0"Impact"Glazed Fiberglass Single Door with"Impact"
Fiberglass Door Sidelite-Outswing(OX or XO-Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.7.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.7 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.7.odf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.8 h.Smooth/Wood Grain Series N 8'0"Impact"Glazed Fiberglass Single Door with"Impact"
Fiberglass Door Sidelites-Outswing(OXO-Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.8.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.8 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.8.odf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.9 i.Smooth/Wood Grain Series N 8'0"Impact"Glazed Fiberglass Double Door-Outswing(XX
Fiberglass Door -Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.9.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.9 for Design Pressure Ratings,any FL15180 R1 AE Eval 15180.9.odf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.10 j.Smooth/Wood Grain Series N 8'0"Impact"Glazed Fiberglass Double Door with"Impact"
Fiberglass Door Sidelites-Outswing(OXXO-Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.10.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.10 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.10.Ddf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.11 k.Smooth/Wood 6'8"Impact"Opaque Fiberglass Single Door-
Grain/Rustic/Mahogany Series N Inswing/Outswing(X-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.11.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.11 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.11.odf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.12 [Grain
Smooth/Wood 6'8"Impact"Opaque Fiberglass Single Door with"Impact"
GS /R Series N Sidelite-Outswing(OX or XO-Configuration)
iberglass Door
http://www.floridabuilding.org/pr/pr appdtl.aspx?param=wGEVXQwtDgsidcHd6ieP8HC... 4/4/2016
Florida Building Code Online Page 4 of 5
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.12.1)df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.12 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.12.odf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.13 m.Smooth/Wood 6'8"Impact"Opaque Fiberglass Single Door with"Impact"
Grain/Rustic/Mahogany Series N Sidelites-Outswing(OXO-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.13.1)df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.13 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.13.1)df
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.14 n.Smooth/Wood 6'8"Impact"Opaque Fiberglass Double Door-
Grain/Rustic/Mahogany Series N Inswing/Outswing(XX-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.14.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.14 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.14.odf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.15 o.Smooth/Wood 6'8"Impact"Opaque Fiberglass Double Door with"Impact"
Grein/Rustic/Mahogany Series N Sidelites-Outswing(OXXO-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.15.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INSf 15180.15 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.15.odf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.16 p.Smooth/Wood Grain Series N 8'0"Impact"Opaque Fiberglass Single Door-
Fiberglass Door Inswing/Outswing(X-Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.16.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other.See INST 15180.16 for Design Pressure Ratings, FL1S180 R1 AE Eval 15180.16.1)df
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.17 q.Smooth/Wood Grain Series N 8'0"Impact"Opaque Fiberglass Single Door with"Impact"
Fiberglass Door Sidelite-Outswing(OX or XO-Configurations)
Limits of Use Installation Instructions
Approved.for use in HVHZ:Yes FL15180 R1 II Inst 15180.17.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INSf 15180.17 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.17.odf
any additional use limitations,installation instructions and Created.by Independent Third Party:Yes
product particulars.
,-A
]� 15180.18 r.Smooth/Wood Grain Series N 8'0"Impact"Opaque Fiberglass Single Door with Sidelites-
�\ Fiberglass Door Outswing(OXO-Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180 18 odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.18 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.18.odf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsidcHd6ieP8HC... 4/4/2016
Florida Building Code Online Page 5 of 5
15180.19 s.Smooth/Wood Grain Series N 80"Impact"Opaque Fiberglass Double Door-
Fiberglass Door Inswing/Outswing()X-Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 R1 II Inst 15180.19.Ddf
Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.19 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.19.Ddf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.20 t.Smooth/Wood Grain Series N 8'0"Impact"Opaque Fiberglass Double Door with"Impact"
Fiberglass Door Sidelites-Outswing(OXXO-Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL1S180 R1 II Inst 15180.20.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.20 for Design Pressure Ratings, FL15180 R1 AE Eval 15180.20.Ddf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
Go to Page 40 0 Page 1/24 0
Back Next
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However emailaddressesare public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under
Chapter 455,F.S.,please click ham.
Product Approval Accepts:
¢Che_k
sccurity.%u:nkres
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwd)gsidcHd6ieP8HC... 4/4/2016
R ` R W Building Consultants, Inc.
WB
B Consulting and Engineering Services I'or the Building Industry
C P,O.Box 230 Valrico;FL 33595 Phone 813.659,9197
Florida Board of Professional Engigeers Ceriificate ofAulhoriaation No.9813
Product Evaluation Report ReportNo.: FL-15180.18
Date: —April 23, 2015
Product
Category Sub Category Manufacturer Product Name
Swinging Plastpro Inc. Smooth/Wood Grain
Exterior Exterior Door 5200 W.Century Blvd. Series N Fiberglass Door
Doors LOS Angeles,CA Outswing
Assemblies g
Phone 440.969.9773 "Impact"
Scope: Product.Evaluation report issued by R W Building Consultants,Inc.&Lyndon F.Schmidt,P.E.(System ID#1898)for
Plastpro Inc.,based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval,Department of
Business&Professional Regulation.
RW Building Consultants and Lyndon.F,Schmidt, P.E.do not have nor will acquire financial,interest in the company
manufacturing or distributing the product in any other entity involved in the approval process of the product named
Limitations:
1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code(FBC)structural requirements
including the"High Velocity Hurricane Zone".
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in the"HVHZ"this product complies with Section 1626 of the Florida Building Code and does not require an impact
resistant covering.
4. When used in areas outside of the"HVHZ"requiring wind borne debris protection this product complies with Section 1609.1.2 of the
FBC and does not require,an impact resistant covering.This product meets missile level"D"and includes Wind Zone.4 as defined in
ASTM E 1.996 and Section 1609.1.2:2 of the FBC.
5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction.
6. Site conditionsthat deviate from the details of drawing FL-15180.18 require further engineering analysis by a licensed engineer or
registered architect.
7. Thisproduct meets water infiltration;requirements for"HVHZ'.
8. See drawing FL-15180.18 for size and design pressure limitations.
Supporting Documents:
1. Test Report No. Test Standard Testing Laboratory Signed by
TEL 07-01030198 TAS 201,202,203-94 Testing Evaluation Lab.,lnc. Wendell Haney,P.E.
CTLA 924W&024W-1 TAS 201;202,203-94 Certified Tesing Laboratories Ramesh Patel, P.E.
ETC 07-209-19303.0 ASTM D2843-99,ASTM D635-98 ETC Laboratories Ben Meunier
ASTM D1929-96,ASTM D638-03
ETC 08-209-20609.0 ASTM D2843-99,ASTM D635-98 ETC Laboratories Gurjinder Dhami
ASTM D1929-96,ASTM D638-03
ETC 06-255-17412.0 ASTM E84-05 ETC Laboratories Joe Doldan,P.E.
ETC 05-255-16776.0 ASTM G26-95,D2843-99,.D635-98, ETC Laboratories Joe Doldan,P.E.
D 1929-06; D638-03
2. Miami-Dade NOA Materials Testing
10-1209.01 HP Polypropylene
14-0423.16 Saflex PVB Interlayer(Eastman Chemical Co.)
3. Drawing No. Prepared by Signed&Sealed by
No.FL-15180.18 RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt,P.E.
4. Calculations Prepared byra.� � Signed&Sealed by
Anchoring RW Building Consultants,Inc.(CA#9813) "E I -a RFs& Lyndon F.Schmidt,P.E.
ASTM E1300 Glass Load Lyndon F.Schmidt,P.E. o , , ^°'
t� 'U ° GCn
5. Quality Assurance °°`° '°°r "ate
Certificate of Participation issued by National Accreditation and
Management Institute,certifying that Plastpro Inc.is manufacturing products - _ m
within a quality assurance program that complies with ISO/IEC 17020 and
Guide 53.
Lyndon F.Schmidt,P.E.
FL PE No.43409
4/24/2015
Sheet 1 of 1 ' ,
plastpro ° - N
xf
J=U M7
5200 W. CENTURY BLVD. =V * E 2 g
LOS ANGELES, CA 90045 N,y z
Smooth / Wood Grain �� J'
Series N Fiberglass Door -?
� e m °
h e.q 9oLa 12OUTS WING a 115.W MAx.OVEMLL FRAMEwIDTH , , m a a
"IMPACT" ¢ c
o6 o
�d yy
Do
z
L
GENERAL NOTESz ci o o-
1. This product has been evaluated and is In compliance with the 5th Edition(2014)Florida Building Code 5
(FBC)structural requirements including the"High Velocity Hurricane Zone"(HVHZ). I? fL
LL 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base materialo D-
Shallbe beyond wall dressing or stucco. O O
o
DO
w
3. When used in the"HVHT'this product complies with Section 1626 of the Florida Building Code and does not a a a
require an impact resistant covering. 9u—]� U
LL 4. When used in areas outside of the'11VHP'requiring wind borne debris protection this product complies with p O
Section 1609.1.2 of the FBC and does not require an impact resistant covering.This product meets missile
level"D"and includes Wind Zone 4 as defined in ASTM E1996 and Section 1609.1.2.2 of the FBC.
c b
a
5 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck a y z
masonry construction. W o
rn
6. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed
engineer or registered architect. °
7. This product meets water infiltration requirements for"HVHZ". a
TABLE OF CONTENTS
a SHEET# DESCRIMON N a
a1 Typical elevation,design pressures,8 general notes
2 Door panel details
3 Sidelite panel details and glazing detail ^Z u
a 4 Horizontal cross sections Dore:02121112 i
5 Vertical cross sections
OVERALL, DESIGN PRESSURE PS SCALE: N.T.S.
6 Vertical cross sections -SWING fRAME MO.BY: JK m
e 7 Buck anchor ng QIMENSION POSITIVE NEGATNE
CHK.BY: LFS 3
_.
8
From
anchoring OUTSWING 115.00"x 96.50" +50.0 -50.0 ORAWINO NO.: N
9 Bill of materials and components FL-15180.18 0
SHEV OF 9 N
a
P-4%lientsWasipm,Inc PERMANE Florida Product A royal FL-15180 C-DraMn s Curren FL-15180.11-20.dw 8-2
9525 MAX.DOOR PANG.HEIGHT -{ _
a
$ ® ® o
S �
P-3o:t o
O v NN go �
-D �!9 ,
0Zzi
Z °
E5
7<
•`o'z
D
m
N N
� >R
2
A 7=O
O
P [+fin
O D M m
M
O 0
A
A.
A.N
EW!LR z
O
n
N
Ul �j 0.075'
/ m
O
00
1
CA I 0.020" I
z ;7�:
p Z.
A
> 0
F=
F= \ _
a 0 1.
n
mS
m
I m O
Gc7Z O
00
v� nJO �O
N Q
Z m m
m
1r
m
1.13"
0
z
%%"%%J11111111"
a
No.43409
yZAl-r
Ai n S PRODUCT: Documents Prepared By:�, •• `�
rA2oR]D►.r' ��
Lyndon F. Schmidt
IN I z N PLASTPRO INC. P.E. No. 43409
in G Z ro FIBERGLASS DOOR rn
0 ca r ti PART OR ASSEMBLY: /1C��/BUILDING CONSULTANTS, INC.
IfD P in 1 04/22 15 UPDATE TO 5TH ED. (2014) FBC JK DOOR PANEL DETAILS JI�YY P•0. Box 230. ValHco, FL 33595
m ro NO DATE BY Phone No.: 813.859.9197
REVISIONS FBPE CA No. 9813
®2012 R.W.BUILDING CDNBUI-NTB INC.
1
ill
� ` .......
1 2 12 .��
5 5 6 6 1-1/4'MIN. ar
EXTERIOR
NOTE g gyp).)
o
60 E �vl
1.SIDELRE PANELS ANCHORED TO FRAME 6" ° . ,y;, z
FROM TOP OF FRAME THEN 14"MAX.ON �� 89 .. ° ��/ �•••, `�� e
CENTER,8 SCREWS TOTAL EACH JAMB. v //i///� •* �, z d;o
Faun n� 8 Z
• t� i uZV
��J, h Em m°cm
0 IL
4 4 INTERIOR v 0 z
8 v Lj
1 (�
21 20 o y
60 0U-
C Cv K c)
m o�
Y am
3 q 3 4 4 HORIZONTAL CROSS SECTION U
0
5 5 6 6 4 shown w/1X sub-buck o F
ti a a
LL
EMB.(TYP•) EXTERIOR
27 40 40 9 88
a, 60 88 Ni 11 K e
p 89 EXTERIOR
89 t0 60
0 0 0
89 `" z
> p �
Q°
a d
b INTERIOR 60 7 INTERIOR
• • 20 8 7 20 21 N
J
° 20 21 21 20 21
DATE:02121112�.15'IvllN. .1S'MIN.� 12 �.1S'MIN. scAtE: N.T.S.
C-SINK C-SINK C-SINK 21 20 12 DWG.ar: JK m
C 15'MIN. .15'MIN.
5 <v
B C-SINK C-SINK cHK.BY. LFS 3
e
/ DaAwwc m:
1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION 3 HORIZOMAL CROSS SEC110N N
E 4 4 4 FL-15180.18 0
SHEEP_�L OF B
B
d
• R�Cljents\ptaMm,Inc PERMANE Florida Product ls\FL-16 Mc-Orawin LurrentifL-15180.11-20.dw 8-S
Q
v
o, o
m m p n
1? v
a..g,
s z
A Q
a a �
4
C2 r .oVv vv
p. b..
1-114 MN. tf1
EMB.(M.) 1-114, N.
EMB.(TYP.)
1-114 MIN.
EMB.(TYP.)
rn m
g cn N ,_
fl m
wA 5< g A
X t—
r v VO tr
Q 1S'in n
tq v
N
Z
CD
M V OD
;;0 .:
v n .
a
G
v d
=
1-1/4" IN.
EMB.
N.43409
$ PRODUCT: 0ocume111a Prrpar+d 9Y•�, � .RORCO..'•.': ���•
on
N FIBERGIASRS DOOR P/E�aND�434a9tdt /''q�� �t, ``.
Z N_ PART OR ASSEMBLY: /r BUILDING CONSULTANTS. INC.
(�' 0' '(1~j i 2 15 UPDATE TO 57H EO. (2074)F8C JK VERTICAL CROSS SECTIONS Phone No.:e/li P.O. Box 2301 .659.9VaIrloo7 33595
D m N NO DATE BY FSPE CJL NO. 98539197
REVISIONS
0 2012 R.W.BuILDI-0 U—Su---INC.
��A%.• •Q_ii N
77$x$xVyy .-`YY �
E
E '� �'• �` a m'm
D
a J •p U N OD Z°
LI � gxz
o`o a
A C Z mda�
m � 4
o=
20 2160 20 21 a
60
89
SEE NOTE 189 L o SEE NO 1 INTERIOR o
z
U z _F
EXTERIOR o ¢�
EXTERIOR INTERIOR n
1 VEIMCAL CROSS SECTION 2 VERTICAL CROSS SECflON
6 6 Shown w/iX sub-buck a
U
C,
N OO
a a
�a}0
INTERIOR it60
V
SEE NOTE 1 69 v^
SEE NOTE 1 89
EXTERIOR EXTERIOR INTERIOR 20 21yo z
Ln
V W 0
za 29 pi
E E $
e•' e N Q j
• e° O Z
Z O
DATE:02121112 ?
N.T.S. °
NOTE 4 VERTICAL CROSS SECTION DWG.BY: K m
S
VERTICAL CROSS SECTION_ 1.SIDELITE PANELS ANCHORED TO FRAME 6" 6 CHK.BY: LFS 3
6 FROM EACH END AND AT CENTERLINE. DRAP7Nc NO, x
N
s FL-15180.18 0
SHEET 8 OF 9 N
O
d
4 8. 4,. 4,.
•A z Q;.'O� o rn
• I I I I �• ••.•....•.• .�' o m
o.ai° z
U N .
I TYP.HEAD ` \� = o z
II II &JAMBS \` ' 8m 9m`oa
II II oZ
I II o
I 2X REINFORCEMENT SHOWN I Ia
FOR REF.ONLY
2X BUCK I I I I
II II �g Z
II II cc
II II �d a hchc
W II II a��
0
II II
6 MASONRY II II a a
OPENING I I I I rm
II II
II II �
II II in
s
BUCK ANCHORING
CONCRETE ANCHOR NOTES:
1.Conaefe anchor locations at the comers maybe adjusted to maintain the min.
sedge distance to mortarjolnts. N UJ a
2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to N= �+
'9 malntaln the min.edge distance to mortar joints,additional concrete anchors g
m
may be requUed to ensure the'MAX.ON CENTER"dimenslon are not exceeded. —z u
3.Concrete anchor table:
a DATE.-02/21 12 i
ANG1i01! MiN MtN C1EAIIANGE .....ICiEARANCF
AIf10R TC+INASONRY TOALTJkCENf
i t1'PE 1AM11BUM1NT... : ;:`_EQGE /AMGHI3R;:':;::;: DWG.BY. N JK m
i............:......... .... .
...
A 1TW CHK.BY. LFS 3
E TAPCON® 1 4" 1.1/4' Y 4° Drumm r+o.:
s ELCO ® FL-15180.18 "-
w ULTRACON 1/4" 1.1/4" 1° 4"
0
SHEEP 7 OF g d
d
it
In
A -_M
cdm
:k Top)
—.-I to° 4" o n°0 el zo
�1 8 in 9 w
in maa�
li
Oz
TYP.HEAD IL _ — — — TYP.HEAD 8 I
aJAMBS JAMBS MASONRY MASONRY
28 OPENING — U WWOPENING O
QO Z(7 �O
FRAME _ _ — — — x= FRAME o z
j
1XBUCK �2XBUCK12 H TYP.®SILL p — TYP.®JAMB — TYP.®SILL TO REINFORCEMENT 17, � o
1 1 I t i'•. 1 I 1 I a
SEE HINGE d"
DETAIL
SnUKE JAMB FRAME ANCHORING HINGE JAMB FRAME ANCHORING
3 Masonry 2X buck construction Masonry TX buck construction
Sz a
L N
o Z
N
K
a CONCRETEANCHOR NOTES: 9 a
u 1.Concrete anchor locatlons at the corners may be adjusted to maintain the Mn. 2$ K
edge distance to mortar jolnfs.
-Concrete anchor locations noted as'MAX ON CENTER"must be adjusted to M 10
maintain the mhl.edge dhtance to mortarjolft additional concrete anchors ALI'maybe requeMired to ensure thAX.ON CENTER"dimenslon are not exceeded.3.Concrete anchor table:
TKRF 3f7 EMBELIMENT TG MASONRY, 1DADIACEtVf LATCH&DEADBOLTDEfWL HINGE DETAIL DATE 02 21 12
scay. N.T.S.
rtW e
A 4• JK 1/ 1.1/4" Y 4" DWG.BY:
TPCON
2 ELCO i/4' 1.1/4" 1" 4" CHK.BY: LFS
ULTRACON
DRAWING NO.:
WOOD SCREW INSTALLATION NOTES:
$ 1.Maintain a mfnlmum 5/8'edge distance,I"end distance.8 1"o.c.spacing of FL-15180.18
ov
wood screws to prevent the spNfing of w ood. sHEEr 8 9
D
d
�' D
4.56"—.•� ��Q��•• �� a
BILL OF MATERIALS I at`i Li
ITEM I DESCRIPTION MATERIAL V' * z`
A I X BUCK SG>=0.55 WOOD = g 0'
B 2X BUCK SG>=0.55 WOOD �i� Q� z N
C 1/4"MAX.SHIM SPACE _ '�,� •'••• .-•• �:` i n a
D 114'X 2-3/4"ELCO OR ITW CONCRETE SCREW STEEL �! 2 36°��27 '4���� � ul
o
U N'
MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI e
E CONCRETE 20 E D b IDE
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 Jamb E m =A o
H 1/4'x 3-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL a g N 9 q
I IXX 2-1/4"PFH ELCO OR TTW CONCRETE SCREW STEEL 4.56"�{ ^ ¢ m a a
JINX 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL I E z°
K #9 X 2-1/7'PFH WOOD SCREW STEEL Jia
L #8 X 2-1/7'PFH WOOD SCREW STEEL
M #8 X 7'PFH WOOD SCREW STEEL
7 FORCE 5 WEATHERSTRIPPING BY ENDURA FOAM
8 COMPRESSION WEATHERSTRIP QLON 650 BY SCHLEGEL FOAM I� 2.44" 2.13" J y
9 4'X 4"BUTT HINGE STEEL z o c
10 #9 X 1"PFH WOOD SCREW STEEL 21 pEADDftl IDE N as
11 #9 X 3/4PFH WOOD SCREW STEEL °N "'
20 FINGER JOINTED PINE FRAME,HEAD&HINGE JAMBS WOOD o�
y 21 POLY FIBER JAMB COMP./VINYL a -Z
d 27 LATCH STRIKE PLATE STEEL o m
N 28 DEADBOLT STRIKE PLATE STEEL o O
29 OUTSWING THRESHOLD BY DLP ALUM./WOOD a
4S6"
31 OUTSWING BUMP THRESHOLD ALUM.
40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 2.03" 'm
LL 60 SIDELITE PANEL-SEE SIDELITE PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS
88 2X REINFORCEMENT(CLEAR PINE)SG>=0.49 WOOD
Lo
89 #7 X 2"PFH DRYWALL SCREW STEEL
8cn
V OUfSW►NG THRESHOLD BY DLP g
U)
468"
ro tr =
8 w
n p J
}T o m
O
Z a
31 OUISWING BUMP THRESHOLD Dae:02121112 i
sc"+ N.T.S. 9
a On.BY: JK m'
5
2
CHK.eY: LFS 3
DR1WM0 NO:
S
FL-15180.18
0
SHEET B OF 9 0
a
r �
< r