HomeMy WebLinkAboutEngineering ALO A � ENGINEERING & TESTING, INC. Phone: (866)781-6889*Fax: (866) 784-8550 APR 0 8 2016 www.floridaengineeringandtesting.com 250 SM.1:`"Avenue •�� PEPPJIITTING Pompano Beach,FL3M69 St. Lucie County, FL DATE: 4/06/16 JOB ORDER#: 16-1115 CLIENT: All Area Roofing ADDRESS: 3921 S. US Highway 1 Fort Pierce,Florida 34982 PROJECT: Theodore Ocem Residence 26 Gauge GulfRib Panel ADDRESS: 2803 Cortez Blvd. Fort Pierce,Florida 34981 FBC 2014/ASCE 7-10 DESIGN PRESSURE CALCULATIONS Proiect Information: Mean Height=Max. 15' Exposure: C Basic/Ultimate Wind Speed: Vi1t=170 mph Length= 68' Category: H Nominal Wind Speed: Vasd=Vi1t*40.6 Width= 46' Slope: 5/12 =22.6° (asd= allowable strength design) Parapet Wall: N/A Residential KZ= 0.85, Kzt 1.0, Kd=0.85 Design Calculations: Velocity Pressure: q=0.00256*KZKzYKdV2 Velocity Pressure (,,It): q=0.00256(0.85)(1.0)(0.85)(170)2] =53.45 psf Velocity Pressure (asd): q=0.00256(0.85)(1.0)(0.85)(170*40.6)2] =32.07 psf Width of Pressure Coefficient: 0.1(46') = 4.6' 0.4(15') = 6.0' ) use: 5'0" Effective Wind Area: <1 W External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP1 = -0.9 1) GCPi = 0.18 2) GCP2 = -1.7 3) GCP3 = -2.6 Design Pressures Based on Vasd: 1) Field PI = 32.07*[(-0.9)—(0.18)] = -34.6 psf 2) Perimeter P2 = 32.07*[(-1.7)—(0.18)] =-60.3 psf 3) Corners P3 = 32.07*[(-2.6)—(0.18)] =-89.2 psf v Q NO QrialitrJ��\�A ,,.flssrcrance 6 Page 2,4/06/16,Job:Order#16-1115 All Area Roofing F1110A Theodore Ocem Residence-26 Gauge GulfRib Panel 2803 Cortez Blvd.;Fort Pierce,Florida 34981: Attachment Requirements: Based on the requirements of Florida Product Approval # 11651.22, Table A, Method 2 with maximum design pressures of -159.25psf; the following are our recommended fastening patterns to attach the 26 ga. GulfRib 3/4" Rib Roof Panel to the minimum 15/32" thick plywood decking utilizing #9-15x1.5" HWH fastener with sealing washing or approved equal to provide a minimum 1/4" fastener penetration through plywood in the following fastener patterns and these fastener row spacings: Type & Area Type 1 Type 2 Field Perimeter& Corners Maximum Total Uplift Design Pressure -69.25psf -159.25psf Fastener Pattern 9"-9"-9"-9" 6.5"-2.511-6.5"-2.511-6.5"- 2.511-6.5" Fastener Pattern Spacing 24" o.c. 12" o.c. Notes: Corners and perimeter (edge, hip, & ridge) area dimension shall not be less than a = TO" (Zone 2: Perimeter (including along ridges) is a 510" wide strip, Zone 3: Corners are 5'0" x 5'0") Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty(as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2014 Edition. Wind load calculations based on ASCE 7-10, FBC 2014 and information provided by client. Client is responsible for verifying existing conditions as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely f„ Mark A.-1Vlesiano; - F1oriia Engineering&j estng,Inc. Flor'c1a Reao4�2G? CertitYcate`gf Auihorizaton No. 6923