HomeMy WebLinkAboutWind Load Calculation r
1918 Corporate Drive
Boynton Beach,FL 33426
WIN ow Ph.561-922-6747
Fax.561-292-3562
Property Information Building Information
Owner: Jusith Woerfel Wind Zone: 170 MPH.
Address: 211 SE Camino St Exposure Category: C
Port Saint Lucie,F134952 Minimum Building Dimension: 55 ft.
Mean Roof Height: 12 ft.
Risk Category: 11
Design Pressure Calculations
[Opening Location Device Device Device Max Positive Max Negative
--]Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 55 62 7 35.7 -38.9
......_.. _.------ - - - ........... ------ -....-- - ---.._._ _ -------------
2 Int 55 62 7 35.7 -38.9
._.._.. --------..__...--...................... ------
----- - ..—
3 End 73 37 7 36.3 -47.5
4 End 73 37 7 36.3 -47.5
5 End 25 37 7 37.8 -50.6
__. ----- -- -. ...._... ----------._...------. ----.--- --— -- - ----
6 Int 73 62 7 35.0 -38.2
7 Int 52 62 7 35.8 -39.0
------- ---- - ----....... ---- ----------- -- ---------------
8 Int 52 62 7 35.8 -39.0
- - __ . ..._.... ------ _....-------- --- --- _....... ----- ----
9 lilt 52 62 7 35.8 -39.0
10 lilt 52 62 7 35.8 -39.0
...... ------- - -- -- . ....- ----- ._......... ------
1 I lilt 73 37 7 36.3 -39.5
12 Int 25 37 7 37.8 -41.0
Prepared in accordance iriih:ASCE 7-10.Chapler 30. Wind Loads-Componenis and Cladding.51h Edition(2014)Florida Building Code.
Page 1 of 1
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE
OPENING (Location) IS THIS A PRODUCT ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS
.NUMBER or Interior OR DOOR MULLION NUMBER (+)PSF {-)PSF (+)PSF (-)PSF SIZE DIMENSIONS REQ Y/NINA REQ YIN
1 Int w 71"LamilG 15-0618.03 55 55 35.7 35.9 74X63 55x62 Y N
2 Int W """L°"'"° 15-0618.03 55 55 35.7 38.9 74X63 55x62 Y N
3 End w 7,8"LamilG 15-0618.03 55 55 36.3 47.5 74X63 7307 N N
4 End W 7,8"`.amilG 15-0618.03 55 55 36.3 47.5 74X63 73x37 N N
5 End W 7/8"Limi'G 15-0618.02 55 55 37.8 50.6 53X77 25x37 N N
6 Int W 7/8"Lami IG 15-0618.03 55 55 35.0 38.2 74X63 73x62 N N
7 Int W "s"Lami'G 15-0618.03 55 55 35.8 39.0 74X63 52x62 Y N
8 Int W La""'G 15-0618.03 55 55 35.8 39.0 74X63 52x62 Y N
9 Int W 7/3"LamilG 15-0618.03 55 55 35.8 39.0 74X63 52x62 Y N
10 Int W 718"LainilG 15-0618.03 55 55 35.8 39.0 74X63 52x62 Y N
11 Int W 7/8"LamilG 15-0618.03 55 55 36.3 39.5 74X63 7307 N N
12 Int W 7B"LainilG 15-0618.02 55 55 37.8 41.0 53X77 25x37 N N