HomeMy WebLinkAboutWind Load Calculation r 1918 Corporate Drive Boynton Beach,FL 33426 WIN ow Ph.561-922-6747 Fax.561-292-3562 Property Information Building Information Owner: Jusith Woerfel Wind Zone: 170 MPH. Address: 211 SE Camino St Exposure Category: C Port Saint Lucie,F134952 Minimum Building Dimension: 55 ft. Mean Roof Height: 12 ft. Risk Category: 11 Design Pressure Calculations [Opening Location Device Device Device Max Positive Max Negative --]Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 55 62 7 35.7 -38.9 ......_.. _.------ - - - ........... ------ -....-- - ---.._._ _ ------------- 2 Int 55 62 7 35.7 -38.9 ._.._.. --------..__...--...................... ------ ----- - ..— 3 End 73 37 7 36.3 -47.5 4 End 73 37 7 36.3 -47.5 5 End 25 37 7 37.8 -50.6 __. ----- -- -. ...._... ----------._...------. ----.--- --— -- - ---- 6 Int 73 62 7 35.0 -38.2 7 Int 52 62 7 35.8 -39.0 ------- ---- - ----....... ---- ----------- -- --------------- 8 Int 52 62 7 35.8 -39.0 - - __ . ..._.... ------ _....-------- --- --- _....... ----- ---- 9 lilt 52 62 7 35.8 -39.0 10 lilt 52 62 7 35.8 -39.0 ...... ------- - -- -- . ....- ----- ._......... ------ 1 I lilt 73 37 7 36.3 -39.5 12 Int 25 37 7 37.8 -41.0 Prepared in accordance iriih:ASCE 7-10.Chapler 30. Wind Loads-Componenis and Cladding.51h Edition(2014)Florida Building Code. Page 1 of 1 A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE OPENING (Location) IS THIS A PRODUCT ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS .NUMBER or Interior OR DOOR MULLION NUMBER (+)PSF {-)PSF (+)PSF (-)PSF SIZE DIMENSIONS REQ Y/NINA REQ YIN 1 Int w 71"LamilG 15-0618.03 55 55 35.7 35.9 74X63 55x62 Y N 2 Int W """L°"'"° 15-0618.03 55 55 35.7 38.9 74X63 55x62 Y N 3 End w 7,8"LamilG 15-0618.03 55 55 36.3 47.5 74X63 7307 N N 4 End W 7,8"`.amilG 15-0618.03 55 55 36.3 47.5 74X63 73x37 N N 5 End W 7/8"Limi'G 15-0618.02 55 55 37.8 50.6 53X77 25x37 N N 6 Int W 7/8"Lami IG 15-0618.03 55 55 35.0 38.2 74X63 73x62 N N 7 Int W "s"Lami'G 15-0618.03 55 55 35.8 39.0 74X63 52x62 Y N 8 Int W La""'G 15-0618.03 55 55 35.8 39.0 74X63 52x62 Y N 9 Int W 7/3"LamilG 15-0618.03 55 55 35.8 39.0 74X63 52x62 Y N 10 Int W 718"LainilG 15-0618.03 55 55 35.8 39.0 74X63 52x62 Y N 11 Int W 7/8"LamilG 15-0618.03 55 55 36.3 39.5 74X63 7307 N N 12 Int W 7B"LainilG 15-0618.02 55 55 37.8 41.0 53X77 25x37 N N