FL# FL16546-RS
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived C
Product Manufacturer Clopay Building Products Company
Address/Phone/Email 8585 Duke Blvd.
Mason,OH 45040
(513)770-6062
mwesterfjeld@clopay.com
Authorized Signature Scott Hamilton
shamiIton@clopay.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Q Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Scott Hamilton
the Evaluation Report
Florida License PE-63286
Quality Assurance Entity Intertek Testing Services NA Inc.-ETL/Warnock Hersey
Quality Assurance Contract Expiration Date 12/31/2028
Validated By Gary Pfuehler
E Validation Checklist-Hardcopy Received
Certificate of Independence FL16546 R5 COI Certification of Independence of Validation Entity-
Gary Pfuehler.pdf
f°L.1.6546 RS COI Statement on Independence of Evaluation Entit-
5coktblamilton 424.pdf
Referenced Standard and Year(of Standard) Standard Year
ANSI/DASMA 108 2005
ANSI/DASMA 115 2005
ASTM E1886 2005
ASTM E1996 2009
ASTM E330 2002
TAS 201 1994
TAS 202 1994
TAS 203 1994
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgvgqu2w%2bn... 12/23/2015
Florida Building Code Online Page 2 of 6
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date.Submitted 08/31/2015
Date Validated 09/11/2015
Date Pending FBC Approval 09/11/2015
Date Approved 10/16/2015
Summary of Products
Go to Page 0 0 .0 0 Page 1/2
FL# Model,Number or Name• Description
16546.1 01 WS-16-HY PAN-21`153: 73, Steel Pan(min.25 ga.)Double-Car(9'2"to 16'0"wide)
1500,75, 190,84A,94,42,48,55, WINDCODE@ WS Garage Door
4RST,6RST,4RSF,6RSF,GDSS,
GDSSV,GR5S,GRSSV,ARSS,
ARSSV,EDSS,EDSSV
Limits of Use Installation Instructions
Approved for'use in HVHZ:No Fu6546 RS II 10192.2-A-Rev14 odf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure:+32 PSF/-32 PSF Evaluation Reports
Other:Solid doors(no glazing)or doors with optional FL16546 R5 AE CBPC 131211-A.odf
Impact-resistant glazing are impact-resistant(large missile Created by Independent Third Party: No
impact).
16546.2 02 W5-16=HY PAN-21`153: 73, Steel Pan(min.25 ga.)Double-Car(9'2"to 16'0"wide)
1500,75, 190,84A,94,42,48,55, WINDCODE@ WS Garage Door
411ST,611ST,4RSF,6RSF,GDSS,
GDSSV,GR5S,GRSSV,ARSS,
ARSSV,EDSS,EDSSV
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16S4§ RS II 101922-B-Revl4.odf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:No Created by Independent Third Party: No
Design Pressure:+32 PSF/-32 PSF Evaluation Reports
Other:The standard glazing available for this product FL16546 R5 AE CBPC 131211-A.Odf
meets the wind load requirements of the building code but Created by Independent Third Party: No
DOES NOT meet the impact resistant requirement for
windborne debris regions.
16546.3 03 W8-16 PAN-2F443:GD4S, Gallery/Artistry/Expressions: Steel Pan(min.24 ga.)
GR4S,ED4S,AR4S Double-Car(9'2"to 16'2"wide)WINDCODE@ W8 Garage
Door with Optional Impact-Resistant Utes
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FLI.654§ R5 11 104791-Rev04,odf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure:+46 PSF/-52 PSF Evaluation Reports
Other:Solid doors(no glazing)or doors with optional F1,16546 R§ AE CBPC 131231-A.12df
Impact-resistant glazing are impact-resistant(large missile Created by Independent Third Party: No
Impact).
1-6-5-4-6.4 04 W6-16 PAN-21F153: 73, 1500, Steel Pan(min.25 ga.)Double-Car(9'2"to 16'2"wide)
75,190,84A,94,42,48,55, WINDCODEO W6 Garage Door
4RST,6RST,4RSF,6RSF,GDSS,
GDSSV,GR5S,GRSSV,ARSS,
ARSSV,EDSS,EDSSV
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16546 R5 II 104710-A-RevO3.odf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure:+36 PSF/-42 PSF Evaluation Reports
Other:Max.Wind Speed(V_ult): 170 MPH.Solid doors(no FL16546 R5 AE CBPC 131211-A.129f
standard glazing)are impact-resistant(large missile Created by Independent Third Party: No
Impact).
16546.5
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwogvgqu2w%2bn... 12/23/2015
These Tables Are For GARAGE DOORS.IN
One and Two Family Dwellings
Garage Doors Installed In Buildings with a
Mean Roof Height of 30' or Less Located in Exposures B, C or D
Table R301.2(2) of the 5t' Edition FBG Residential
COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE [PSFJ
❑160 EXPOSURE;B. 9'x 7' Door=+24.3 -27.5
❑160 EXPOSURE11316'x 7' Door=+23.3 -26.0
X160 EXPOSURE C 9'x 7' Door=+29.5 -$3.3 (1 story and max 15'
X160-EPOSURE'V16'_X T Door,=+28.2 -3 mean roof height)
❑160 EXPOSURE,C .9'x 7' Door=+34.1 -38.5 (2 story and max 30'
❑160 EXPOSURE C 16'X 7'Door=+32.7 -36.4 mean roof height)
❑160 EXPOSURE D 9'x 7'Door=+35.8 -40.5 (1 story and max 15'
❑160 EXPOSURE D 16'x 7' Door=+34.3 -38.3 mean roof height)
❑160 EXPOSURE D 9'x 7' Door=+40.4 -45.7 (2 story and max 30'
❑160 EXPOSURE D 16'x 7' Door=+38.7 -43.2 mean roof height)
0150 EXPOSURE B 9'x 7' Door=+21.3 -24.1
F1 150 EXPOSURE B 16'x 7' Door=+20.4 22.7
❑150 EXPOSURE C 9'x 7' Door=+25.8 -29.2 (1 story and max 15'
❑150 EXPOSURE C 16'x 7'Door=+24.7 -27.5 mean roof height
1-1150 EXPOSURE C 9'x 7' Door=+29.9 -33.8 (2 story and max 30'
[J1 50 EXPOSURE C 16'x 7' Door=+28.6 .-31.8 mean roof height)
❑150 EXPOSURE D 9'x 7'Door=+31.4 :35.5 (1 story'and max 15'
DI 50 EXPOSURE D 16'x 7' Door=+30.0 -33.4 mean roof height)
❑150 EXPOSURE D 9'x 7'Door=+35.4 -40.1 (2 story and max 30'
E]150EXPOSURE D 16'x 7''Door=+33'.9 -37.7 mean roof height)
Notes•-
■ Secure existing bucks per the Product Approval or Design Professional
Instructions prior to installing the door. Have product approvals
available at the time of inspection.
Glazing in Garage.doors must comply with.R301.2.1.2 (Glazing must
be impact resistant or shuttered) - 1 l ^
Miami Dade N.O.A or Florida Product Approval