Loading...
HomeMy WebLinkAboutEngineering (2) T reasure Harvey E. Koehnen C oast Professional Engineer#32831 B Wilding Architect #AR0009471 at E ngineers, Certified General Contractor#CGCO24776 Inc. These Tables Are For Roof Coverings Roof coverings Installed on Buildings with a Mean Roof F_jelght of 30'or Less Located In Exposures B, C OFILE Table 8301.2[2]4{, P7 t Ascii 7-le COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE[PSF3. 160Exp B 160Exp G 16OExp C 160Exp D 160Exp D (One story (Two story*) (One story ) (Two storyl Roof>0 to 7 degrees Zone 1 -27.6 -33.4 -38.7 -40.6 -45.9 7degrees= 1112/12 pitch Zone 2 -46A -56,2 _65.0 -68.3 -77A Zone 3 -69.8 -84.5 -97.7 -102.7 -115.9 r_Ro,o f>_7-to 2-7 degrees _'Zone-1-_-2 6--.3)1 -30,7 -3s.5 -37.2 -42 �27 degrees=6/12 pitch Zone 2 -44,1 -63.4 -61.8 -64.9 -73.3 Zone 3 -65.1) -783 -91.2 - 95.7 - 108:;1 Roof>27 to 45 degrees Zone 1 -27.8, -33.7 40.0 -40.1 4.5 dea­-_=s= 1?/I'? 7 Zone 3 -32.4 -39.3 _45A -473 -53.3 150 Exp B 150 Exp G 150 Exp C 150 Exp D 150 Ezp D (one story*) (two story*) (one story*) (two story) Roof>0 to 7 degrees Zone 1 -24.3 -29.6 -34.1 -35.8 -40.4 7degreer.= 11/2112 pitch Zone 2 -40,8 -49A -57.2 _60.0 -673 Zone 3 -61.4 -74.3 -86.0 -90.3 -102.0 Roof>7 to 27 degrees Zone 1 -22,2 -26,9 -31.1 -32.7 -36.9 27 degrees=6/12 pitch Zone 2 -38.7 -46.9 -54.2 -56.9 -64.3 Zone 3 . -67,3 -69.4 -803 -84.3 -95.2 Root>27 to 45 degrees Zone 1 -24.3 -29.5 -34.1 -85.8 -40.4 45 degrees= 12/12 pitch Zone 2 -28.4 -34.4 -39.8 -41.8 -47.2 Zone 3 -28.4 34.4 39.8 -41.8 -47.2 One story*-one story building with a maximum mean roof height of 15 feet Two storY4=two story building with a maximum mean roof height of 30 feet -if-allowed by the Miami Dade N.O.A or Florida Product Approval, any systern.that does-not meet the Minimum components and cladding pressures for the area that the building is located per this form may require a Florida licensed engineer to revise the fastener spacing T C B E,Inc. 7205 Elyse Circle PHONE (772)466-5509 Port Saint Lude FAX (772)489-3035 � Florida 34952-_8 212 E-MAIL hkoehnen@tcbeweb.com WEB SITE http://www.tcbeweb.com EXTERIOR RESEARCH&DESIGN,I.I.C. Certificate of Authorization#9503 RD ,,, 353 CHRISTIAN STREET,UNIT#13 TRINITY E F 41 OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Entegra Roof Tile,LLC Evaluation Report E39310.11.11-1-R2 1289 NE 9th Avenue FL7804-R8 Okeechobee,FL 34972 Date of Issuance:11/02/2011 Revision 2:07/02/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code(HVHZ)sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles(HVHZ jurisdictions) LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: ���tatnrn,„— r ���.•*'STo •tU The facsimile seal appearing was authorized by Robert Nieminen, Robert J.M.Nieminen,P.E. P.E.on 07/02/2015.This does not serve as an electronically signed Florida RegistrationNo.59166,FloridaDCAANE1983 ''' ;fC ta��ii``" document.Signed,sealed hardcopieshave been transmitted tothe r Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity)ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose.