These Tables Are For Roof Coverings
Roof coverings Installed on Buildings with a
Mean Roof F_jelght of 30'or Less Located In Exposures B, C OFILE
Table 8301.2[2]4{, P7 t Ascii 7-le
COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE[PSF3.
160Exp B 160Exp G 16OExp C 160Exp D 160Exp D
(One story (Two story*) (One story ) (Two storyl
Roof>0 to 7 degrees Zone 1 -27.6 -33.4 -38.7 -40.6 -45.9
7degrees= 1112/12 pitch Zone 2 -46A -56,2 _65.0 -68.3 -77A
Zone 3 -69.8 -84.5 -97.7 -102.7 -115.9
r_Ro,o f>_7-to 2-7 degrees _'Zone-1-_-2 6--.3)1 -30,7 -3s.5 -37.2 -42
�27 degrees=6/12 pitch Zone 2 -44,1 -63.4 -61.8 -64.9 -73.3
Zone 3 -65.1) -783 -91.2 - 95.7 - 108:;1
Roof>27 to 45 degrees Zone 1 -27.8, -33.7 40.0 -40.1
4.5 dea-_=s= 1?/I'? 7
Zone 3 -32.4 -39.3 _45A -473 -53.3
150 Exp B 150 Exp G 150 Exp C 150 Exp D 150 Ezp D
(one story*) (two story*) (one story*) (two story)
Roof>0 to 7 degrees Zone 1 -24.3 -29.6 -34.1 -35.8 -40.4
7degreer.= 11/2112 pitch Zone 2 -40,8 -49A -57.2 _60.0 -673
Zone 3 -61.4 -74.3 -86.0 -90.3 -102.0
Roof>7 to 27 degrees Zone 1 -22,2 -26,9 -31.1 -32.7 -36.9
27 degrees=6/12 pitch Zone 2 -38.7 -46.9 -54.2 -56.9 -64.3
Zone 3 . -67,3 -69.4 -803 -84.3 -95.2
Root>27 to 45 degrees Zone 1 -24.3 -29.5 -34.1 -85.8 -40.4
45 degrees= 12/12 pitch Zone 2 -28.4 -34.4 -39.8 -41.8 -47.2
Zone 3 -28.4 34.4 39.8 -41.8 -47.2
One story*-one story building with a maximum mean roof height of 15 feet
Two storY4=two story building with a maximum mean roof height of 30 feet
-if-allowed by the Miami Dade N.O.A or Florida Product Approval, any systern.that does-not meet the
Minimum components and cladding pressures for the area that the building is located per this form
may require a Florida licensed engineer to revise the fastener spacing
T C B E,Inc. 7205 Elyse Circle PHONE (772)466-5509
Port Saint Lude FAX (772)489-3035
�
Florida 34952-_8 212 E-MAIL hkoehnen@tcbeweb.com
WEB SITE http://www.tcbeweb.com
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate of Authorization#9503
RD ,,, 353 CHRISTIAN STREET,UNIT#13
TRINITY E F 41 OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Entegra Roof Tile,LLC Evaluation Report E39310.11.11-1-R2
1289 NE 9th Avenue FL7804-R8
Okeechobee,FL 34972 Date of Issuance:11/02/2011
Revision 2:07/02/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code(HVHZ)sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles(HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by: ���tatnrn,„— r
���.•*'STo •tU
The facsimile seal appearing was authorized by Robert Nieminen,
Robert J.M.Nieminen,P.E.
P.E.on 07/02/2015.This does not serve as an electronically signed
Florida RegistrationNo.59166,FloridaDCAANE1983 ''' ;fC ta��ii``" document.Signed,sealed hardcopieshave been transmitted tothe
r Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity)ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.