HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC. 806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE(772)460-7751 FAX(772)460-4244 EMAIL cookmenard@yahoo.com R r3 April 8 2016 APR 1 1 2016 PERMiTTiNG St. Lucie County; rL St. Lucie County Building Department. Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce,FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at 1203 Fleetwood Lane,St Lucie County, Florida Manufacturer: Gulf Coast Supply&Manufacturing, LLC. Profiles: 26 Ga. 5V Crimp,FL#11651.12 Code: FBC 2014;Section 1507 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 20'Maximum Pitch: 6"/12" Required Design Pressure: Zone1:-38.2 Zone 2:-53.9 Zone3:-101.4 Maximum Uplift Pressure: -108.5 @ 12"O.C.&-156.5@ 6"O.C. Fasteners: Method of tile attachment: #9-15x1.5 HWH with sealing washer with minimum%" penetration @ 12"O.C. Underlayment: Membrane: Resisto Sa Smooth Ply 40 is a self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. Roof Decking: Existing S/8"plywood sheathing to be nailed w/8d x 2 ring shank nails @ 6" O.C.thru out zone 1,4" O.C. perimeter,and 6"O.C.field zone 2,and 4"O.C.thru out zone 3. The above approved,as per Florida Building Code Compliance acceptances,2014 Florida Building Code,and the Manufacturer's recommendations. Respectfully Submitted, Peter B.Cook Cook& Menard Architecture, Inc. Florida Registration No. AA0003494, NCARB Certification No. 31,789