Loading...
HomeMy WebLinkAboutProduct Approval (3) Florida Building Code Online bttp://www.floridabuilding.org/pr/pr_app_dtI.aspx?pararn=wGEVX... _rfass i'CLi 4ia t, j:di ti!';�tl'l� BCIS Home 1 Log In I User Registration Hot Topics SubmitSurcharge I Stats&Facts Publications ':, FBC Staff ` 1305 Site Ma Business «.= fF Product Approval ls�E � Professional USER:Public User ) Requllatio n APR 1 12016 R1 1 I Product Aooroval Menu>Product or Aoo!ication Sear`h>Aoollcatbn List>Application Detail l _ - - PERIMITTIRIC FL# FL2418-119 St. Lucie County, FL Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviel by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Maxim Industries, Inc. Address/Phone/Email 1630 Terre Colony Court Dallas,TX 75212-6221 (214) 905-2021 info@maximskylights.com Authorized Signature David Thornton Info@maximskylights.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Sky Lights Subcategory Skylight Compliance Method Certification Mark or Listing Certification Agency National Accreditation &Management Institute Validated By National Accreditation &Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 1 of 3 11/23/2015 2:14 PM Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVX... Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 07/10/2015 Date Validated 07/16/2015 Date Pending FB.0 Approval Date Approved 07/25/2015 Summary of Products FL# Model, Number or Name Description 2418.1 Dade Curb Mount Skylight Polycarbonate Glazed Aluminum Skylight Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL2418.R9 C CAC NI009198A-R4,pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration 17 Impact Resistant:Yes 12/31/2017 Design Pressure: +60/-60 Installation Instructions Other: FL2418 R9 -II DCM1507. d Verified By: National Accreditation &Manag Created by Independent Third Party: Evaluation Reports FL2418-.R9 AE .Evaluation Report TBA 15-C Created by Independent Third Party: Yes 2418.2 Dade Self Flashing Skylight Polycarbonate Glazed Aluminum Skylight Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL2418 119-C CAC. N1009198-R4.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration 13 Impact Resistant:Yes 12/31/2017 Design Pressure: +60/-60 Installation Instructions Other: FL2418 R9 II DSF1507.Ddf Verified By: National Accreditation &Manag Created by Independent Third Party: Evaluation Reports FL2418 R9 AE Evaluation Report TBA 15- Created by Independent Third Party: Yes Back FNe.t Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::R, Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records req electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487. Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department wi they have one.The einalls provided may be used for official communication with the licensee.However email addresses are public record.If supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if yo Chapter 455,F.S.,please click here. Product Approval Accepts: ®`' ECheck FM 2 of 3 11/23/2015 2:14 PM NOTICE OF PRODUCT CERTIFICATION ACCKFy�1 o+J" CERTIFICATION NO: NI009198-114 DATE: 12/30/2007 CERTIFICATION PROGRAM: Structural COMPANY: Maxim CODE: M-1256-1 REVISION DATE: 12/18/2014 To verify that the"Notice of Product Certification"is valid,please visit www.NAiMICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NA1VII approved certification label must be applied. to the product to claim certification status. Please review and advise NA1v1I if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Maxim Industries,Inc. Series "Dade Self-Flashing" 1630 Terre Colony Court Polycarbonate Glazed Aluminum Skylight Dallas,Texas 75212 Configuration:O Glazing:Exterior Dome-0.118"Hyzod Polycarbonate w/8"rise/Interior Dome-0.118" Hyzod Polycarbonate w/4"rise Overall: W-416" DLO: W-39" H-816" H-719" SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure=+60/-60 psf Large,Missile Impact Rated Product Tested By: Architectural Testing,Inc. Report No: ATI-01-43381.01 Expiration Date: December 31,2017 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 F MAXIM INDUSTRIES, INC. z DADE SELF FLASHING SKYLIGHT g= c u LL0 ]O F, LL rJ Q W �i V a MCI) C7a W 3'MAX.FROM 12°MAX. f� CORNERS TYP. O.C.TYP. GENERAL NOTES: Cn • ————————————— • 1.This Product has been designed and tested to conform to the requirements as determined in the Florida Building Code 5th Edition(2014). 0 I I a I I 2.This,product is designed for within and outside High Velocity Hurricane Zone. J, w N cOi • I I • 3.The Details and specifications shown herein represent product engineered and tested for water, o I I air,impact,cyclic and uniform static air pressure testing in conformance with TAS 201,TAS 202, r- E I I TAS 203. o • I I • 4.When used in areas requidng wind bome debds protection this product complies with Sections Q Cl)p > 1609.12 and 1626 of the Florida Building Cade 5th Edition(2014)and does not require an Impact rn cc _j r- resistance covering. N LL a o ate) c 00 �a I I 5.Building structure must be designed by licensed professional engineer to Garry the loads applied v m � • I •I • o from this product ro •.�, O a9�a I I o 14 6.All anchors to surrounding structure to be as listed and spaced as specified in these drawings,any E c N Li I I ° i substitutions shall be approved by licensed professional Engineer. C u 3 0 5 _Q • I I • y 7.Skylight Material Is 6063-T6 Extruded Aluminum.Skylight Inner and Outer Dome Material is =� rn I O o Polycarbonate,NOA412-0605.05. N 04 I I 8.Substrate material:Wood,minimum specific gravity of 0.42 I� • I I • �`111es�sscs�gr� I I ��.DO�RE eR'''• .92j9 DESIGN PRESURE RATING(PSF) IMPACT RATING I t 60.0 LARGE MISSILE IMPACT STATE OF • • O �ORID Cc I I «r I f.ro i 1110 `�```o IF1 L--------------�I • • THEODORE BERMMI,P.E. • • • • • NO.098U 07110as 44:50-MAX OA O.LO.WIDTH DATE: 07/10/15 SC MAX OA FLANGE WIDTH DWG A DSF1507 ELEVATION AND ANCHOR LAYOUT SCALE: N.T.S. SHEET: 1 of 2 I I Minimum#12 X 1.25"fastener by others.Pre-punched installtion holes 4"from each comer,maximum 10.5"on center.Minimum penetration=I". 2 .060"X 1.5"X 1.75"6063-T6 extruded aluminum retaining angle.Aluminum angle mitered and welded @ four corners. F 3 52.5"X 100.375"UV Enhanced outer polycarbonate dome @ 8"height on test sample.(height varies per size) U 4 52.5"X 100.375"UV Enhanced inner polycarbonate dome @ 4"height on test sample.(height varies per size) Z U 5 OSI PR256 urethane sealant.Located between aluminum retaining angle and outer dome&between inner dome and aluminum frame. T ro 6 Sealant tape.I"X.125"located between outer and inner domes. g= 7 6063-T6 extruded aluminum frame.Aluminum frame mitered and welded @ four corners. u_ Gn 8 412 X 1.75"fastener.One fastener located equidistant from each corner.Four fasteners per skylight. LL-1 p 9 #10X.375 18-8 stainless steel fastener.Located 4"from each comer,maximum 11"on center. w A U 10 All units equal to or less than the total square footage or the test specimen,36 square feet,will be accepted under this approval. w v) 11 Minimum distance=4"from angle lip to roof surface for shingles or BUR without insulation.For insulation and tile roof add the height and insulation O thickness to the 4"minimum height. p Ca 0 O3 Outer Polycarbonate Dome U Inner Polycarbonate Dome #12 Stainless Steel Fastener with Ln 0 ® ® uS o neoprene gasket.One fastener +. C'a E located equidustant from each ,tt. m 5 comer.(Four fasteners per Z o �M ^m O2 .060"Extruded Aluminum� Sealant O f skylight) � a m C:) L Retaining Angle © it LL �r o. Sealant Tape < o L ao m Sealant Tape© #10 X.375"stainless steel fastener @ m 7 4"from each corner,maximum I V O O CO n �—Condensation Gutter �on center, t .Q U m Ln o - 060"Aluminum Frame Q ? Q w toN u U � n.' 4- Design Pressure: 60psf a,,t�!=yPSPPpto Minimum#12 X 1.5" q44,�ppORE BF'leo Test Pressure: -120psf &+180psf 11 fastener.Installation ;9h9 holes 3"from each No 09814 corner,maximum 12" 3"Installation Flange on center.Minimum v /penetration=V. �: -STATE OF , ORS :' � rPr PII E!!11!!� T EOOORE BOWAN.RE NO.M14 fmeats Self Flashing Model DATE: 07/10/15 Roof deck and framing by others.All roof details shall comply with all DWG#: DSF1507 sections of the Florida Building Code and Florida Residential Code_ SCALE: N.T.S. t SHEET: 2 of 2 LIGHT,TRANSMISSION & GLAZING PERFORMANCE Sheffield Makrolon®Polycarbonate Dome All insulatedghss provided byMiuinz Clear/Bronze(CB) 25% •60% .90 .97 0.7(ASHRAE) includes azgon gas. Clear/Clear(CC) 74% 89% 90 .97 1.02 (ASHRAE) A/!laminated impact Clear/Gray(CG) 43% 60% .90 .97 0.7(ASHRAE) zesiftai,aklass h Bronze/Bronze(BB). 07% 36% .90 .97 0.49 (ASHRAE) marzufactu,rd with DuPozzt"",SerttryGln<'Pl:u Clear/White(CW) 23% 40% .90 .97 0.71 (ASHRAE) ' Insulated Glass Performance LoE366(Low E Cubed)/Argon Gas: 0.27 0.24 0.43 66% Bronze Tint/Argon Gas: 0.63 0.31 0.52 61% Gray Tint/Argon Gas: 0.63 0.31 0.52 61% FRAME FINISHES ,! l Mill Finish White Powdercoat Bronze Anodized Custom Color Powdercoat Custom Color Powdercoat FEATURES • Approvals include multiple Miami-Dade County Product Control NOA's;Florida Building Commission,FBC 2418-113 (2010); Texas Department of Insurance,TDI Report(s)SK-13&SK-18 • All Maxim Skylights are tested and conform to AAMA/WDMA/CSA 101/I.S.2/A440-05 and all,or part,of the following standards:ASTM E283,ASTM E330,ASTM E331,ASTM E547,ASTM E1886,Missile Level C as specified in ASTM E1996-99,TAS 201-94,TAS 202-94,TAS 203-94,and ASTM E1300-02/03. • All Maxim Skylights are third parry certified to performance compliance and quality assurance by the National Accreditation Management Institute(NAMI). Available in any size or shape up to 25 square feet,the largest impact resistant insulated glass skylight available. Insulated Glass for maximum energy efficiency available as Tempered,Laminated and DuPont—SentryGlas°Plus Impact resistant. Unlimited configurations to meet any conditions. ° Optional curb assembly w/prefinished white interior,solid wood curb and aluminum counterflashing. Insulated glass is tested to-200psf negative pressure for a+1-100psf Design Pressure. All Maxim insulated glass comes with XL Edge'technology providing the lowest failure rate in the industry.Developed in part from our suppliers 45 years of experience in manufacturing dual-seal silicone insulated glass. • Mill Finish,Bronze Anodized,Clear Anodized or an unlimited number of powdercoat colors are also available. -- All insulated glass is covered by the manufacturer for 20 years Curb Mount available up to 36 square feet&Self Flashing up to 32 square feet in any size or shape. Polycarbonate domes are tested to-120psf&+180psf for a+/-60psf Design Pressure. Sheffield Plastics Makrolon SL UV enhanced polycarbonate outer domes for the ultimate in ultraviolet light protection. Virtually unbreakable polycarbonate domes meet large&small missile impact rating. Sealed double,domes prevent moisture from occurring between the domes. Polycarbonate glazing meets UL 972 forced entry protection. ° Stainless steel fasteners eliminate rust and corrosion. 'Any type of cleaning performed on the roof,including removal of mold,mildew,fungus,or dirt,by pressure of any kind with water or chemical means will damage polycarbonare domes and void any warranty.A derailed insulated glass warranty is available upon request.WARNING:SKYLIGHTS MAY NOT SUPPORT LIVE LOADS!While these skylights have passed testing for large and small missile impact resistance,1000 ft/lbs fall protection resistance and up to 200ps£positive pressure testing,they are not intended for any live load!Do not stand,sir,lean,or rest on any part of the skylight. Corporate Florida 1630 Terre Colony Court•Dallas,Texas 75212.6221 1818 7'Avenue North,Suite 2•Lake Worth,Florida 33461 Toll Free 888-222-4898°Fax 214-905-2024 Toll Free 800-367-8168°Fax 561-588-9283 I