HomeMy WebLinkAboutDrawing r--
1
36" X 80"
Ti ERfED
REPLACE DOOR IN 1 OPENING ONLY. ® �y
NEW DOOR TO BE IMPACT RESISTANT- APR 9 q 2 e0l4
69
HURRICANE SHUTTERS NOT REQUIRED. PERVIITTI,"_;
Sit. Lucia CC;aiii , FL
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 36 80 20.00 4 48.2 1 -52.5 FL4904.1 76.0 1 -76.0 SIDE GARAGE-LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 25 FT 2 IN
BROOKS RESIDENCE
132 .PARLIAMENT COURT DOOR REPLACEMENT PLAN
FORT PIERCE, FLORIDA