Loading...
HomeMy WebLinkAboutEngineering FLO A R€- 0 IF—L11EED` ENGINEERING & TESTING, INC. APR 13 2096 Phone: (866) 781-6889*Fax: (866) 784-8550 W197w.floridaengineeringandtesting.com PERMITTING 250 S.W.13"'Avenue ' St. Lucie County, FL Pompano Beach,FL 33069 DATE: 3/30/16 JOB ORDER#: 16-1054 CLIENT: Freedom Roofers, LLC ADDRESS: 5575 US 1 - Suite# 1 & 2 Vero Beach,FL 32967 PROJECT: Toth Residence Flat Non-Insulated Wood Roof Deck ADDRESS: 361 NE Bracken Road Port Saint Lucie,Florida FBC 2014/ASCE 7-10 DESIGN PRESSURE CALCULATIONS Project Information: Height= 8' Exposure: C Basic/Ultimate Wind Speed: V,,It=170 mph Length= 17' Category: II Nominal Wind Speed: Vad=V,,It*40.6 Width= 15' Slope: <7° (asd=allowable strength design) Parapet Wall: <3' Residential KZ=0.85,Kzt= 1.0, Kd=0.85 Design Calculations: Velocity Pressure: q= 0.00256*KZK�tKdV2 Velocity Pressure (,I): q--0.00256(0.85)(1.0)(0.85)(170)2] = 53.45 psf Velocity Pressure (.d): q=0.00256(0.85)(1.0)(0.85)(170* 0.6)2] =32.07 psf Width of Pressure Coefficient: 0.1(15') = 1.5' 0.4(8) = 3.2' ) use: 3'0" Effective Wind Area: <1 Of 2 For parapet height three feet(3') or larger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP1 = -1.0 1) GCPi = 0.18 2) GCP2 = -1.8 3) GCP3 = -2.8 q Q+ 1l Quality���\ L� .�/✓murance 3�� Page 2,3/30/16,Job Order#16-1054 2" Freedom Roofers,LLC-Toth Residence FILO A Flat Non-Insulated Wood Roof Deck 361 NE Bracken Road;Port Saint Lucie,FL: Design Pressures Based on Vasd: 1) Field P1 = 32.07*[(-1.0)—(0.18)] = -37.8 psf 2) Perimeter P2 = 32.07*[(-1.8)—(0.18)] = -63.5 psf 3) Corners P3 = 32.07*[(-2.8)—(0.18)] = -95.6 psf Attachment Requirements Per RAS-117: Based on the requirements of Florida Product Approval FL#9487.1, Appendix 1, System W-12, pg 3 of 3, with a maximum design pressure of -135.0psf, the following are our - -- - --recommended-fastening-patterns-to attach the_proposed_-EasyNailBase_base_sheet to_-the_ min 15/32" plywood at max. 24" spans deck utilizing approved OMG # 12 or # 14HD fasteners with OMG 3 in. Galvalume Steel Plate or Tru-Fast DP or HD with MP-3Plates: Field: 6" o.c. @ 4" laps and 4 staggered rows 6" o.c. Perimeter: 6" o.c. @ 4" laps and 4 staggered rows 6" o.c. Corners: 6" o.c. @ 4" laps and 4 staggered rows 6" o.c. Notes: Corners and perimeter area dimension shall not be less than a=3'0" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty(as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2014 Edition. Wind load calculations based on ASCE 7-10, FBC 2014 and information provided by client. Client is responsible for verifying existing conditions as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely,;, Mark';A.-Me9 an-;.P-.E" F1orida,Erigine'0 g'&. 'estjng; Inc. Cbi f,f ca t&of Au&ki- i:or No. 6923